DBLECTRO HG4138B/006

HG4138B
Miniature PCB / QC Power Relay
FEATURES
30A switching capacity
PCB + QC termination
Meets UL508 and UL873
spacing requirements
TYPICAL APPLICATIONS
Power supply device
Industrial control
Home appliances
Heating, refrigeration, ventilation
CONTACT RATING
Form
1 Form A (1H)
240VAC
28VDC
Max. Switching Current
Max. Switching Voltage
Max. Continuous Current
30A
30A
30A
Rated Load
30A
8.31KVA
900W
Max. Switching Power
1 Form C (1Z)
NO
NC
15A
20A
10A
10A
20A
10A
10A
20A
15A
277VAC/30VDC
15A
20A
10A
4.155KVA
5.54KVA
2.77KVA
450W
600W
300W
1A, 5VDC/12VAC
1 Form B (1D)
Min. Load
UL /CSA RATING
Load Type
Voltage
1 Form A (1H)
1 Form B (1D)
General Purpose
240VAC
240VAC
28VDC
240VAC
120VAC
240VAC
120VAC
120VAC
277VAC
30A
30A
20A
2HP
1HP
80A /30A
98A /22A
TV5
10A
15A
15A
10A
0.5HP
0.25HP
Resistive
Motor
LRA/FLA
Tungsten
Ballast
1 Form C (1Z)
NO
NC
20A
10A
10A
20A
20A
10A
2HP
0.5HP
0.25HP
1HP
30A/10A
50A /20A
20A/7A
TV3
3A
TV5
10A
TV3
3A
CONTACT DATA
AgCdO, AgSnOInO
50 mΩ, max. at 0.1A, 6VDC
Material
Initial Contact Resistance
Service Life
Mechanical
107 ops.
Electrical
105 ops.
COIL DATA
Coil Voltage
Code
Nominal Voltage
(VDC)
Resistance
(Ω) ±10%
Must Operate
Voltage max.
(VDC)
Must Release
Voltage min.
(VDC)
005
006
009
012
024
048
110
5
6
9
12
24
48
110
27
40
97
155
660
2560
10330
3.75
4.50
6.75
9.00
18.00
36.00
82.50
0.5
0.6
0.9
1.2
2.4
4.8
11.0
CHARACTERISTICS
Operate Time
Release Time
Insulation Resistance
Dielectric Strength
Shock Resistance
Vibration Resistance
Power Consumption
Ambient Temperature
Weight
15 ms. typical
10 ms. typical
1000 MΩ, at 500VDC, 50%RH
1500 Vrms, 1 min. between open contacts
2500 Vrms, 1 min. between coil and contacts
10 g, 11ms, functional; 100 g, destructive
DA 1.5mm. 10 - 55 Hz
0.9W, approx.
-55 to 85ºC operating, -40 to 130ºC storage
30 g, approx.
HG4138B
1/2
HG4138B
ORDERING DESIGNATION
Example:
HG4138B /
Model
Coil Voltage Code
Contact Form
1H: 1 Form A; 1D: 1 Form B; 1Z: 1 Form C
Mounting Version
0: PCB Mount
Version
1: Sealed; 2: Dust Cover
012 -
1Z
0
1
F
Thermal Class
Nil: UL Class B; F: UL Class F
REFERENCE CURVES
OVERALL DIMENSIONS, MOUNTING HOLES AND WIRING DIAGRAM (mm)
Overall Dimensions
COM
NO
Mounting Holes (Bottom View)
NC
Wiring Diagram (Top View)
NOTES
1.
2.
3.
4.
5.
All parameters, unless otherwise specified, are measured at ambient temperature 23ºC.
In mounting holes drawing, the * holes is not needed for 1 Form A, the ** hole is not needed for 1 Form B.
To exert optimum electrical life, please remove the tape of sealed version after cleaning process.
Custom-made services available with operational quantity. Please let us know your special requirements.
Specifications subject to change without prior notice.
DB LECTRO INC. 3600 boul. Matte suite I Brossard Qc J4Y-2Z2
TEL:(450)-444-1424 FAX: (450)-444-4714
HG4138B
2/2