MICROCHIP SST89V516RD2

FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
The SST89E516RDx and SST89V516RDx are members of the FlashFlex family
of 8-bit microcontroller products designed and manufactured with SST’s patented
and proprietary SuperFlash CMOS semiconductor process technology. The splitgate cell design and thick-oxide tunneling injector offer significant cost and reliability benefits for SST’s customers. The devices use the 8051 instruction set and
are pin-for-pin compatible with standard 8051 microcontroller devices.
Features
• 8-bit 8051-Compatible Microcontroller (MCU) with
Embedded SuperFlash Memory
– Fully Software Compatible
– Development Toolset Compatible
– Pin-For-Pin Package Compatible
• Second DPTR register
– 0 to 40 MHz at 5V
• Low EMI Mode (Inhibit ALE)
• SST89V516RD2 Operation
– 0 to 33 MHz at 3V
• SPI Serial Interface
• 1 KByte Internal RAM
• Standard 12 Clocks per cycle, the device has an
option to double the speed to 6 clocks per cycle.
• Dual Block SuperFlash EEPROM
– 64 KByte primary block +
8 KByte secondary block
(128-Byte sector size for both blocks)
– Individual Block Security Lock with SoftLock
– Concurrent Operation during
In-Application Programming (IAP)
– Memory Overlay for Interrupt Support during IAP
• Support External Address Range up to 64 KByte
of Program and Data Memory
• Three High-Current Drive Ports (16 mA each)
• Full-Duplex, Enhanced UART
– Framing Error Detection
– Automatic Address Recognition
• Ten Interrupt Sources at 4 Priority Levels
• Programmable Counter Array (PCA)
• Four 8-bit I/O Ports (32 I/O Pins) and
One 4-bit Port
• SST89E516RD2 Operation
• Three 16-bit Timers/Counters
• Programmable Watchdog Timer (WDT)
• TTL- and CMOS-Compatible Logic Levels
• Brown-out Detection
• Low Power Modes
– Power-down Mode with External Interrupt Wake-up
– Idle Mode
• Temperature Ranges:
– Commercial (0°C to +70°C)
– Industrial (-40°C to +85°C)
• Packages Available
– 40-contact WQFN (Port 4 feature not available)
– 44-lead PLCC
– 40-pin PDIP (Port 4 feature not available)
– 44-lead TQFP
• All non-Pb (lead-free) devices are RoHS compliant
– Four External Interrupt Inputs
©2013 Silicon Storage Technology, Inc.
www.microchip.com
DS25093B
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Product Description
The SST89E516RDx and SST89V516RDx are members of the FlashFlex family of 8-bit microcontroller products designed and manufactured with SST’s patented and proprietary SuperFlash CMOS
semiconductor process technology. The split-gate cell design and thick-oxide tunneling injector offer
significant cost and reliability benefits for SST’s customers. The devices use the 8051 instruction set
and are pin-for-pin compatible with standard 8051 microcontroller devices.
The devices come with 72 KByte of on-chip flash EEPROM program memory which is partitioned into
2 independent program memory blocks. The primary Block 0 occupies 64 KByte of internal program
memory space and the secondary Block 1 occupies 8 KByte of internal program memory space.
The 8-KByte secondary block can be mapped to the lowest location of the 64 KByte address space; it
can also be hidden from the program counter and used as an independent EEPROM-like data memory.
In addition to the 72 KByte of EEPROM program memory on-chip and 1024 x8 bits of on-chip RAM,
the devices can address up to 64 KByte of external program memory and up to 64 KByte of external
RAM.
The flash memory blocks can be programmed via a standard 87C5x OTP EPROM programmer fitted
with a special adapter and the firmware for SST’s devices. During power-on reset, the devices can be
configured as either a slave to an external host for source code storage or a master to an external host
for an in-application programming (IAP) operation. The devices are designed to be programmed insystem and in-application on the printed circuit board for maximum flexibility. The devices are pre-programmed with an example of the bootstrap loader in the memory, demonstrating the initial user program code loading or subsequent user code updating via the IAP operation. The sample bootstrap
loader is available for the user’s reference and convenience only; SST does not guarantee its functionality or usefulness. Chip-Erase or Block-Erase operations will erase the pre-programmed sample code.
©2013 Silicon Storage Technology, Inc.
DS25093B
2
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Functional Blocks
8051
CPU Core
ALU,
ACC,
B-Register,
Instruction Register,
Program Counter,
Timing and Control
Interrupt
Control
Oscillator
Flash Control Unit
Watchdog Timer
SuperFlash
EEPROM
Primary
Block
64K x8
RAM
1K x8
8
I/O
I/O Port 0
Secondary
Block
8K x8
10 Interrupts
8
Security
Lock
I/O
I/O Port 1
8
I/O
I/O Port 2
8
Timer 0 (16-bit)
I/O
I/O Port 3
4
Timer 1 (16-bit)
I/O
I/O Port 4
Timer 2 (16-bit)
SPI
PCA
Enhanced
UART
1273 B1.0
Figure 1: Functional Block Diagram
©2013 Silicon Storage Technology, Inc.
DS25093B
3
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
(CEX2 / MOSI) P1.5
1
P0.3 (AD3)
P0.2 (AD2)
P0.1 (AD1)
P0.0 (AD0)
VDD
P1.0 (T2)
P1.1 (T2 EX)
P1.2 (ECI)
P1.3 (CEX0)
P1.4 (CEX1 / SS#)
Pin Assignments
40
P0.4 (AD4)
(CEX3 / MISO) P1.6
P0.5 (AD5)
(CEX4 / SCK) P1.7
P0.6 (AD6)
RST
P0.7 (AD7)
(RXD) P3.0
Top View
(TXD) P3.1
(contacts facing down)
EA#
ALE/PROG#
(A12) P2.4
(A11) P2.3
(A10) P2.2
P2.5 (A13)
(A9) P2.1
(T1) P3.5
(A8) P2.0
P2.6 (A14)
VSS
(T0) P3.4
XTAL1
P2.7 (A15)
XTAL2
(INT1#) P3.3
(RD#) P3.7
PSEN#
(WR#) P3.6
(INT0#) P3.2
1273 40-wqfn QI P1.0
Figure 2: Pin Assignments for 40-Contact WQFN
©2013 Silicon Storage Technology, Inc.
DS25093B
4
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
(T2) P1.0
1
40
VDD
(T2 EX) P1.1
2
39
P0.0 (AD0)
(ECI) P1.2
3
38
P0.1 (AD1)
4
37
P0.2 (AD2)
P0.3 (AD3)
(CEX0) P1.3
(CEX1 / SS#) P1.4
5
36
(CEX2 / MOSI) P1.5
6
35
P0.4 (AD4)
(CEX3 / MISO) P1.6
7
34
P0.5 (AD5)
(CEX4 / SCK) P1.7
8
(RXD) P3.0
40-pin PDIP
Top View 33
32
9
31
10
RST
P0.6 (AD6)
P0.7 (AD7)
EA#
(TXD) P3.1
11
30
ALE/PROG#
(INT0#) P3.2
12
29
PSEN#
(INT1#) P3.3
13
28
P2.7 (A15)
(T0) P3.4
14
27
P2.6 (A14)
(T1) P3.5
15
26
P2.5 (A13)
(WR#) P3.6
16
25
P2.4 (A12)
(RD#) P3.7
17
24
P2.3 (A11)
XTAL2
18
23
P2.2 (A10)
XTAL1
19
22
P2.1 (A9)
20
21
P2.0 (A8)
VSS
1273 40-pdip PI P2.0
Figure 3: Pin Assignments for 40-pin PDIP
©2013 Silicon Storage Technology, Inc.
DS25093B
5
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
P0.3 (AD3)
P0.2 (AD2)
P0.1 (AD1)
P0.0 (AD0)
VDD
P4.2/INT3#
P1.0 (T2)
P1.1 (T2 EX)
P1.2 (ECI)
P1.3 (CEX0)
P1.4 (SS# / CEX1)
Data Sheet
44 43 42 41 40 39 38 37 36 35 34
1
33
P0.4 (AD4)
(CEX3 / MISO) P1.6
2
32
P0.5 (AD5)
(CEX4 / SCK) P1.7
3
31
P0.6 (AD6)
RST
4
30
P0.7 (AD7)
(RXD) P3.0
5
29
EA#
INT2#/P4.3
6
28
P4.1
(TXD) P3.1
7
27
ALE/PROG#
(INT0#) P3.2
8
26
PSEN#
(INT1#) P3.3
9
25
P2.7 (A15)
(T0) P3.4
10
24
P2.6 (A14)
(T1) P3.5
11
23
12 13 14 15 16 17 18 19 20 21 22
P2.5 (A13)
(A11) P2.3
(A10) P2.2
(A9) P2.1
(A8) P2.0
P4.0
VSS
XTAL1
XTAL2
(RD#) P3.7
(WR#) P3.6
44-lead TQFP
Top View
(A12) P2.4
(CEX2 / MOSI) P1.5
1273 44-tqfp TQJ P3.0
Figure 4: Pin Assignments for 44-lead TQFP
©2013 Silicon Storage Technology, Inc.
DS25093B
6
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
2 1 44 43 42 41 40
VDD
P0.3 (AD3)
P1.0 (T2)
3
P0.2 (AD2)
P1.1 (T2 EX)
4
P0.1 (AD1)
P1.2 (ECI)
5
P0.0 (AD0)
P1.3 (CEX0)
6
P4.2/INT3#
P1.4 (SS# / CEX1)
Data Sheet
7
39
P0.4 (AD4)
(CEX3 / MISO) P1.6
8
38
P0.5 (AD5)
(CEX4 / SCK) P1.7
9
37
P0.6 (AD6)
RST
10
36
P0.7 (AD7)
(RXD) P3.0
11
35
EA#
INT2#/P4.3
12
34
P4.1
(TXD) P3.1
13
33
ALE/PROG#
(INT0#) P3.2
14
32
PSEN#
(INT1#) P3.3
15
31
P2.7 (A15)
(T0) P3.4
16
30
P2.6 (A14)
(T1) P3.5
17
29
18 19 20 21 22 23 24 25 26 27 28
P2.5 (A13)
(A11) P2.3
(A10) P2.2
(A9) P2.1
P4.0
(A8) P2.0
VSS
XTAL1
XTAL2
(RD#) P3.7
(WR#) P3.6
44-lead PLCC
Top View
(A12) P2.4
(CEX2 / MOSI) P1.5
1273 44-plcc NJ P4.0
Figure 5: Pin Assignments for 44-lead PLCC
©2013 Silicon Storage Technology, Inc.
DS25093B
7
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Pin Descriptions
Table 1: Pin Descriptions (1 of 3)
Symbol
Type1
P0[7:0]
I/O
Port 0: Port 0 is an 8-bit open drain bi-directional I/O port. As an output port each
pin can sink several LS TTL inputs. Port 0 pins float that have ‘1’s written to them,
and in this state can be used as high-impedance inputs. Port 0 is also the multiplexed low-order address and data bus during accesses to external memory. In
this application, it uses strong internal pull-ups when transitioning to VOH. Port 0
also receives the code bytes during the external host mode programming, and
outputs the code bytes during the external host mode verification. External pullups are required during program verification.
P1[7:0]
I/O with internal pull-ups
Port 1: Port 1 is an 8-bit bi-directional I/O port with internal pull-ups. The Port 1
output buffers can drive LS TTL inputs. Port 1 pins are pulled high by the internal
pull-ups when “1”s are written to them and can be used as inputs in this state. As
inputs, Port 1 pins that are externally pulled low will source current because of the
internal pull-ups. P1[5, 6, 7] have high current drive of 16 mA. Port 1 also receives
the low-order address bytes during the external host mode programming and verification.
P1[0]
I/O
P1[1]
I
T2EX: Timer/Counter 2 capture/reload trigger and direction control
P1[2]
I
ECI: PCA Timer/Counter External Input:
This signal is the external clock input for the PCA timer/counter.
P1[3]
I/O
CEX0: Compare/Capture Module External I/O
Each compare/capture module connects to a Port 1 pin for external I/O. When not
used by the PCA, this pin can handle standard I/O.
P1[4]
I/O
SS#: Master Input or Slave Output for SPI.
OR
CEX1: Compare/Capture Module External I/O
P1[5]
I/O
MOSI: Master Output line, Slave Input line for SPI
OR
CEX2: Compare/Capture Module External I/O
P1[6]
I/O
MISO: Master Input line, Slave Output line for SPI
OR
CEX3: Compare/Capture Module External I/O
P1[7]
I/O
SCK: Master clock output, slave clock input line for SPI
OR
CEX4: Compare/Capture Module External I/O
P2[7:0]
I/O with internal pull-up
Name and Functions
T2: External count input to Timer/Counter 2 or Clock-out from Timer/Counter 2
Port 2: Port 2 is an 8-bit bi-directional I/O port with internal pull-ups. Port 2 pins
are pulled high by the internal pull-ups when “1”s are written to them and can be
used as inputs in this state. As inputs, Port 2 pins that are externally pulled low will
source current because of the internal pull-ups. Port 2 sends the high-order
address byte during fetches from external Program memory and during accesses
to external Data Memory that use 16-bit address (MOVX@DPTR). In this application, it uses strong internal pull-ups when transitioning to VOH. Port 2 also receives
some control signals and high-order address bits during the external host mode
programming and verification.
©2013 Silicon Storage Technology, Inc.
DS25093B
8
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Table 1: Pin Descriptions (Continued) (2 of 3)
Symbol
Type1
P3[7:0]
I/O with internal pull-up
Name and Functions
Port 3: Port 3 is an 8-bit bidirectional I/O port with internal pull-ups. The Port 3
output buffers can drive LS TTL inputs. Port 3 pins are pulled high by the internal
pull-ups when “1”s are written to them and can be used as inputs in this state. As
inputs, Port 3 pins that are externally pulled low will source current because of the
internal pull-ups. Port 3 also receives some control signals and a partial of highorder address bits during the external host mode programming and verification.
P3[0]
I
RXD: Universal Asynchronous Receiver/Transmitter (UART) - Receive input
P3[1]
O
TXD: UART - Transmit output
P3[2]
I
INT0#: External Interrupt 0 Input
P3[3]
I
INT1#: External Interrupt 1 Input
P3[4]
I
T0: External count input to Timer/Counter 0
P3[5]
I
T1: External count input to Timer/Counter 1
P3[6]
O
WR#: External Data Memory Write strobe
P3[7]
O
RD#: External Data Memory Read strobe
PSEN#
I/O
Program Store Enable: PSEN# is the Read strobe to External Program Store.
When the device is executing from Internal Program Memory, PSEN# is inactive
(VOH). When the device is executing code from External Program Memory,
PSEN# is activated twice each machine cycle, except when access to External
Data Memory while one PSEN# activation is skipped in each machine cycle. A
forced high-to-low input transition on the PSEN# pin while the RST input is continually held high for more than ten machine cycles will cause the device to enter
External Host mode for programming.
RST
I
Reset: While the oscillator is running, a high logic state on this pin for two
machine cycles will reset the device. After a reset, if the PSEN# pin is driven by a
high-to-low input transition while the RST input pin is held high, the device will
enter the External Host mode, otherwise the device will enter the Normal operation mode.
EA#
I
External Access Enable: EA# must be driven to VIL in order to enable the device
to fetch code from the External Program Memory. EA# must be driven to VIH for
internal program execution. However, Security lock level 4 will disable EA#, and
program execution is only possible from internal program memory. The EA# pin
can tolerate a high voltage2 of 12V.
ALE/
PROG#
I/O
Address Latch Enable: ALE is the output signal for latching the low byte of the
address during an access to external memory. This pin is also the programming
pulse input (PROG#) for flash programming. Normally the ALE3 is emitted at a
constant rate of 1/6 the crystal frequency4 and can be used for external timing and
clocking. One ALE pulse is skipped during each access to external data memory.
However, if AO is set to 1, ALE is disabled.
P4[3:0]5
I/O with internal pull-ups
Port 4: Port 4 is an 4-bit bi-directional I/O port with internal pull-ups. The port 4
output buffers can drive LS TTL inputs. Port 4 pins are pulled high by the internal
pull-ups when ‘1’s are written to them and can be used as inputs in this state. As
inputs, port 4 pins that are externally pulled low will source current because of the
internal pull-ups.
P4[0]
I/O
Bit 0 of port 4
P4[1]
I/O
Bit 1 of port 4
P4[2] /
INT3#
I/O
Bit 2 of port 4 / INT3# External interrupt 3 input
©2013 Silicon Storage Technology, Inc.
DS25093B
9
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Table 1: Pin Descriptions (Continued) (3 of 3)
Symbol
Type1
P4[3] /
INT2#
I/O
XTAL1
I
Crystal 1: Input to the inverting oscillator amplifier and input to the internal clock
generator circuits.
XTAL2
O
Crystal 2: Output from the inverting oscillator amplifier
VDD
I
Power Supply
VSS
I
Ground
Name and Functions
Bit 3 of port 4 / INT2# External interrupt 2 input
T0-0.0 25093
1. I = Input; O = Output
2. It is not necessary to receive a 12V programming supply voltage during flash programming.
3.ALE loading issue: When ALE pin experiences higher loading (>30pf) during the reset, the MCU may accidentally enter
into modes other than normal working mode. The solution is to add a pull-up resistor of 3-50 KΩ to VDD, e.g. for ALE
pin.
4. For 6 clock mode, ALE is emitted at 1/3 of crystal frequency.
5. Port 4 is not present on the PDIP and WQFN packages.
©2013 Silicon Storage Technology, Inc.
DS25093B
10
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Memory Organization
The device has separate address spaces for program and data memory.
Program Flash Memory
There are two internal flash memory blocks in the device. The primary flash memory block (Block 0)
has 64 KByte. The secondary flash memory block (Block 1) has 8 KByte. Since the total program
address space is limited to 64 KByte, the SFCF[1:0] bit are used to control program bank selection.
Please refer to Figure 6 for the program memory configuration. Program bank selection is described in
the next section.
The 64K x8 primary SuperFlash block is organized as 512 sectors, each sector consists of 128 Bytes.
The 8K x8 secondary SuperFlash block is organized as 64 sectors, each sector consists also of 128
Bytes.
For both blocks, the 7 least significant program address bits select the byte within the sector. The
remainder of the program address bits select the sector within the block.
EA# = 1
SFCF[1:0] = 00
EA# = 0
FFFFH
FFFFH
External
64 KByte
EA# = 1
SFCF[1:0] = 01, 10, 11
FFFFH
56 KByte
Block 0
64 KByte
Block 0
2000H
1FFFH
0000H
0000H
8 KByte
Block 1
0000H
1273 F01.0
Figure 6: Program Memory Organization
©2013 Silicon Storage Technology, Inc.
DS25093B
11
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Program Memory Block Switching
The program memory block switching feature of the device allows either Block 1 or the lowest 8 KByte of
Block 0 to be used for the lowest 8 KByte of the program address space. SFCF[1:0] controls program
memory block switching.
Table 2: SFCF Values for Program Memory Block Switching
SFCF[1:0]
Program Memory Block Switching
01, 10, 11
Block 1 is not visible to the program counter (PC).
Block 1 is reachable only via in-application programming from 0000H - 1FFFH.
00
Block 1 is overlaid onto the low 8K of the program address space; occupying address locations 0000H 1FFFH.
When the PC falls within 0000H - 1FFFH, the instruction will be fetched from Block 1 instead of Block 0.
Outside of 0000H - 1FFFH, Block 0 is used. Locations 0000H - 1FFFH of Block 0 are reachable through
in-application programming.
T0-0.0 25093
Reset Configuration of Program Memory Block Switching
Program memory block switching is initialized after reset according to the state of the Start-up Configuration bit SC0. The SC0 bit is programmed via an external host mode command or an IAP Mode command. See Table 14.
Once out of reset, the SFCF[0] bit can be changed dynamically by the program for desired effects.
Changing SFCF[0] will not change the SC0 bit.
Caution must be taken when dynamically changing the SFCF[0] bit. Since this will cause different
physical memory to be mapped to the logical program address space. The user must avoid executing
block switching instructions within the address range 0000H to 1FFFH.
Table 3: SFCF Values Under Different Reset Conditions
State of SFCF[1:0] after:
Power-on
or
External
Reset
WDT Reset
or
Brown-out
Reset
Software
Reset
U (1)
00
(default)
x0
10
P (0)
01
x1
11
SC01
T0-0.0 25093
1. P = Programmed (Bit logic state = 0),
U = Unprogrammed (Bit logic state = 1)
Data RAM Memory
The data RAM has 1024 bytes of internal memory. The RAM can be addressed up to 64KB for external
data memory.
©2013 Silicon Storage Technology, Inc.
DS25093B
12
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Expanded Data RAM Addressing
The SST89E/V516RDx have the capability of 1 KByte RAM. See Figure 7.
The device has four sections of internal data memory:
1.
The lower 128 Bytes of RAM (00H to 7FH) are directly and indirectly addressable.
2.
The higher 128 Bytes of RAM (80H to FFH) are indirectly addressable.
3.
The special function registers (80H to FFH) are directly addressable only.
4.
The expanded RAM of 768 Bytes (00H to 2FFH) is indirectly addressable by the move
external instruction (MOVX) and clearing the EXTRAM bit. (See “Auxiliary Register
(AUXR)” in Section , “Special Function Registers”)
Since the upper 128 Bytes occupy the same addresses as the SFRs, the RAM must be accessed indirectly. The RAM and SFRs space are physically separate even though they have the same addresses.
When instructions access addresses in the upper 128 Bytes (above 7FH), the MCU determines
whether to access the SFRs or RAM by the type of instruction given. If it is indirect, then RAM is
accessed. If it is direct, then an SFR is accessed. See the examples below.
Indirect Access:
MOV@R0, #data; R0 contains 90H
Register R0 points to 90H which is located in the upper address range. Data in “#data” is written to
RAM location 90H rather than port 1.
Direct Access:
MOV90H, #data; write data to P1
Data in “#data” is written to port 1. Instructions that write directly to the address write to the SFRs.
To access the expanded RAM, the EXTRAM bit must be cleared and MOVX instructions must be used.
The extra 768 bytes of memory is physically located on the chip and logically occupies the first 768
bytes of external memory (addresses 000H to 2FFH).
When EXTRAM = 0, the expanded RAM is indirectly addressed using the MOVX instruction in combination with any of the registers R0, R1 of the selected bank or DPTR. Accessing the expanded RAM
does not affect ports P0, P3.6 (WR#), P3.7 (RD#), or P2. With EXTRAM = 0, the expanded RAM can
be accessed as in the following example.
Expanded RAM Access (Indirect Addressing only):
MOVX@DPTR, A; DPTR contains 0A0H
DPTR points to 0A0H and data in “A” is written to address 0A0H of the expanded RAM rather than
external memory. Access to external memory higher than 2FFH using the MOVX instruction will
access external memory (0300H to FFFFH) and will perform in the same way as the standard 8051,
with P0 and P2 as data/address bus, and P3.6 and P3.7 as write and read timing signals.
When EXTRAM = 1, MOVX @Ri and MOVX @DPTR will be similar to the standard 8051. Using
MOVX @Ri provides an 8-bit address with multiplexed data on Port 0. Other output port pins can be
used to output higher order address bits. This provides external paging capabilities. Using MOVX
@DPTR generates a 16-bit address. This allows external addressing up the 64K. Port 2 provides the
©2013 Silicon Storage Technology, Inc.
DS25093B
13
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
high-order eight address bits (DPH), and Port 0 multiplexes the low order eight address bits (DPL) with
data. Both MOVX @Ri and MOVX @DPTR generates the necessary read and write signals (P3.6 WR# and P3.7 - RD#) for external memory use. Table 4 shows external data memory RD#, WR# operation with EXTRAM bit.
The stack pointer (SP) can be located anywhere within the 256 bytes of internal RAM (lower 128 bytes
and upper 128 bytes). The stack pointer may not be located in any part of the expanded RAM.
Table 4: External Data Memory RD#, WR# with EXTRAM bit
MOVX @DPTR, A or MOVX A, @DPTR
MOVX @Ri, A or MOVX A, @Ri
AUXR
ADDR < 0300H
ADDR >= 0300H
ADDR = Any
EXTRAM = 0
RD# / WR# not asserted
RD# / WR# asserted
RD# / WR# not asserted1
EXTRAM = 1
RD# / WR# asserted
RD# / WR# asserted
RD# / WR# asserted
T0-0.0 25093
1. Access limited to ERAM address within 0 to 0FFH; cannot access 100H to 02FFH.
©2013 Silicon Storage Technology, Inc.
DS25093B
14
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
2FFH
Expanded
RAM
768 Bytes
FFH
80H
7FH
(Indirect Addressing)
00H
000H
FFFFH
(Indirect Addressing)
Upper 128 Bytes
Internal RAM
FFH
(Direct Addressing)
Special
Function
Registers
(SFRs)
80H
Lower 128 Bytes
Internal RAM
(Indirect & Direct
Addressing)
(Indirect Addressing)
FFFFH
(Indirect Addressing)
External
Data
Memory
External
Data
Memory
0300H
2FFH
Expanded RAM
0000H
000H
EXTRAM = 0
EXTRAM = 1
1273 F02.0
Figure 7: Internal and External Data Memory Structure
©2013 Silicon Storage Technology, Inc.
DS25093B
15
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Dual Data Pointers
The device has two 16-bit data pointers. The DPTR Select (DPS) bit in AUXR1 determines which of
the two data pointers is accessed. When DPS=0, DPTR0 is selected; when DPS=1, DPTR1 is
selected. Quickly switching between the two data pointers can be accomplished by a single INC
instruction on AUXR1. (See Figure 8)
AUXR1 / bit0
DPS
DPTR1
DPS = 0 → DPTR0
DPS = 1 → DPTR1
DPTR0
DPL
82H
DPH
83H
External Data Memory
1273 F03.0
Figure 8: Dual Data Pointer Organization
Special Function Registers
Most of the unique features of the FlashFlex microcontroller family are controlled by bits in special
function registers (SFRs) located in the SFR memory map shown in Table 5. Individual descriptions of
each SFR are provided and reset values indicated in Tables 6 to 10.
Table 5: FlashFlex SFR Memory Map
F8H
F0H
E8H
E0H
D8H
D0H
C8H
C0H
B8H
B0H
A8H
A0H
98H
90H
88H
80H
IP11
B1
IEA1
ACC1
CCON1
PSW1
T2CON1
WDTC1
IP1
P31
IE1
P21
SCON1
P11
TCON1
P01
CH
8 BYTES
CCAP0H CCAP1H CCAP2H CCAP3H CCAP4H
CL
CCAP0L
CCAP1L
CCAP2L
CCAP3L
CCAP4L
CMOD
CCAPM0
CCAPM1
CCAPM2
CCAPM4
T2MOD
RCAP2L
RCAP2H
TL2
CCAPM3
SPCR
TH2
SFCM
SPSR
AUXR1
SFAL
SFAH
SFDT
SFST
XICON
TL0
DPL
TL1
DPH
IP1H
SADEN
SFCF
SADDR
IPH
P4
SBUF
TMOD
SP
TH0
TH1
WDTD
AUXR
SPDR
PCON
FFH
F7H
EFH
E7H
DFH
D7H
CFH
C7H
BFH
B7H
AFH
A7H
9FH
97H
8FH
87H
T0-0.0 25093
1. Bit addressable SFRs
©2013 Silicon Storage Technology, Inc.
DS25093B
16
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Table 6: CPU related SFRs
Symbol Description
Direct
Address
Bit Address, Symbol, or Alternative Port Function
MSB
Reset
Value
LSB
ACC1
Accumulator
B1
B Register
F0H
PSW1
Program Status
Word
D0H
SP
Stack Pointer
81H
SP[7:0]
07H
DPL
Data Pointer
Low
82H
DPL[7:0]
00H
DPH
Data Pointer
High
83H
DPH[7:0]
00H
IE1
Interrupt
Enable
A8H
EA
EC
ET2
ES
ET1
EX1
ET0
EX0
00H
IEA1
Interrupt
Enable A
E8H
-
-
-
-
EBO
-
-
-
xxxx0xxx
b
IP1
Interrupt Priority
Reg
B8H
-
PPC
PT2
PS
PT1
PX1
PT0
PX0
x0000000
b
IPH
Interrupt Priority
Reg High
B7H
-
PPCH
PT2
H
PS
H
PT1H
PX1
H
PT0H
PX0
H
x0000000
b
IP11
Interrupt Priority
Reg A
F8H
-
-
-
-
PBO
PX3
PX2
-
xxxx0xxx
b
IP1H
Interrupt Priority
Reg A High
F7H
-
-
-
-
PBO
H
PX3
H
PX2H
-
xxxx0xxx
b
PCON
Power Control
87H
SMOD
1
SMOD
0
BOF
PO
F
GF1
GF0
PD
IDL
00010000
b
AUXR
Auxiliary Reg
8EH
-
-
-
-
-
-
EXTRA
M
AO
xxxxxxx0
0b
AUXR1 Auxiliary Reg
1
A2H
-
-
-
-
GF2
0
-
DPS
xxxx00x0
b
XICON External
Interrupt Control
AEH
-
EX3
IE3
IT3
0
EX2
IE2
IT2
00H
E0H
ACC[7:0]
00H
B[7:0]
CY
AC
F0
RS
1
RS0
00H
OV
F1
P
00H
T0-0.0 25093
1. Bit Addressable SFRs
©2013 Silicon Storage Technology, Inc.
DS25093B
17
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Table 7: Flash Memory Programming SFRs
Symbol Description
Direct
Address MSB
Bit Address, Symbol, or Alternative Port Function
IAPE
N
-
-
-
-
SW
R
LSB
Reset
Value
BSE
L
x0xxxx00
b
SFCF
SuperFlash
Configuration
B1H
-
SFCM
SuperFlash
Command
B2H
FIE
SFAL
SuperFlash
Address Low
B3H
SuperFlash Low Order Byte Address Register - A7 to A0 (SFAL)
00H
SFAH
SuperFlash
Address High
B4H
SuperFlash High Order Byte Address Register - A15 to A8
(SFAH)
00H
SFDT
SuperFlash
Data
B5H
SuperFlash Data Register
00H
SFST
SuperFlash
Status
B6H
FCM[6:0]
SB1
_i
SB2_
i
SB3
_i
-
EDC_i
00H
FLASH_BU
SY
-
-
000x00xx
b
T0-0.0 25093
Table 8: Watchdog Timer SFRs
Symbol Description
WDTC
1
WDTD
Bit Address, Symbol, or Alternative Port Function
Direct
Address MSB
Watchdog
Timer
Control
C0H
Watchdog
Timer
Data/Reload
85H
-
-
-
WDOUT
WDRE
WDTS
LSB
WDT
Reset
Value
SWDT
Watchdog Timer Data/Reload
xxx00x00
b
00H
T0-0.0 25093
1. Bit Addressable SFRs
©2013 Silicon Storage Technology, Inc.
DS25093B
18
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Table 9: Timer/Counters SFRs
Symbol Description
TMOD
Bit Address, Symbol, or Alternative Port Function
Direct
Address MSB
Timer/Counter
Mode Control
89H
TCON1
Timer/Counter
Control
88H
TH0
Timer 0 MSB
8CH
Timer 1
LSB
Reset
Value
Timer 0
00H
GAT
E
C/T#
M1
M0
GATE
C/
T#
M1
M0
TF1
TR1
TF0
TR0
IE1
IT1
IE0
IT0
00H
TH0[7:0]
00H
TL0
Timer 0 LSB
8AH
TL0[7:0]
00H
TH1
Timer 1 MSB
8DH
TH1[7:0]
00H
TL1
Timer 1 LSB
8BH
TL1[7:0]
00H
T2CON Timer / Coun1
ter 2
Control
C8H
TF2
EXF
2
RCL
K
TCL
K
EXEN
2
TR2
C/
T2#
CP/
RL2#
00H
T2MOD Timer2
Mode Control
C9H
-
-
-
-
-
-
T2O
E
DCEN
xxxxxx00
b
TH2
Timer 2 MSB
CDH
TL2
Timer 2 LSB
TH2[7:0]
00H
CCH
TL2[7:0]
00H
RCAP2 Timer 2
H
Capture MSB
CBH
RCAP2H[7:0]
00H
RCAP2 Timer 2
L
Capture LSB
CAH
RCAP2L[7:0]
00H
T0-0.0 25093
1. Bit Addressable SFRs
©2013 Silicon Storage Technology, Inc.
DS25093B
19
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Table 10: Interface SFRs
Symbol Description
SBUF
Bit Address, Symbol, or Alternative Port Function
Direct
Address MSB
LSB
Serial Data Buffer
99H
SCON Serial Port Control
98H
SADD
R
Slave Address
A9H
SADDR[7:0]
00H
SADE
N
Slave Address
Mask
B9H
SADEN[7:0]
00H
SPCR
SPI Control
Register
D5H
SPIE
SPE
SPSR
SPI Status
Register
AAH
SPIF
WCO
L
SPDR
SPI Data Register
86H
P01
Port 0
80H
P11
Port 1
90H
P21
Port 2
A0H
P31
Port 3
P42
Port 4
1
SBUF[7:0]
RESET
Value
SM0/
FE
SM1
SM2
DOR
D
REN
MST
R
TB8
CPO
L
Indeterminate
RB8
CPH
A
TI
SPR
1
RI
SPR
0
00H
04H
00H
SPDR[7:0]
00H
P0[7:0]
-
-
-
B0H
RD#
WR#
T1
A5H
1
1
1
-
FFH
-
-
T2E
X
T2
T0
INT1
#
INT0
#
TXD
RXD
1
P4.3
P4.2
P4.1
P4.0
P2[7:0]
FFH
FFH
FFH
FFH
T0-0.0 25093
1. Bit Addressable SFRs
2. P4 is similar to P1 and P3 ports
©2013 Silicon Storage Technology, Inc.
DS25093B
20
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Table 11: PCA SFRs
Direct
Address MSB
Bit Address, Symbol, or Alternative Port Function
LSB
RESET
Value
Symbol
Description
CH
CL
PCA Timer/Counter
F9H
E9H
CCON1
PCA Timer/Counter
Control Register
D8H
CF
CR
-
CCF4
CCF
3
CCF
2
CCF
1
CCF0
00x0000
0b
CMOD
PCA Timer/Counter
Mode Register
D9H
CID
L
WDTE
-
-
-
CPS
1
CPS
0
ECF
00xxx000
b
CCAP0
H
PCA Module 0
Compare/Capture
Registers
FAH
CCAP0H[7:0]
00H
EAH
CCAP0L[7:0]
00H
FBH
CCAP1H[7:0]
00H
EBH
CCAP1L[7:0]
00H
FCH
CCAP2H[7:0]
00H
ECH
CCAP2L[7:0]
00H
FDH
CCAP3H[7:0]
00H
EDH
CCAP3L[7:0]
00H
FEH
CCAP4H[7:0]
00H
EEH
CCAP4L[7:0]
00H
CCAP0
L
CCAP1
H
CCAP1
L
CCAP2
H
CCAP2
L
CCAP3
H
CCAP3
L
CCAP4
H
CCAP4
L
PCA Module 1
Compare/Capture
Registers
PCA Module 2
Compare/Capture
Registers
PCA Module 3
Compare/Capture
Registers
PCA Module 4
Compare/Capture
Registers
CH[7:0]
CL[7:0]
00H
00H
DAH
-
ECOM
0
CAPP
0
CAPN
0
MAT
0
TOG
0
PWM
0
ECCF
0
x000000
0b
DBH
-
ECOM
1
CAPP
1
CAPN
1
MAT
1
TOG
1
PWM
1
ECCF
1
x000000
0b
DCH
-
ECOM
2
CAPP
2
CAPN
2
MAT
2
TOG
2
PWM
2
ECCF
2
x000000
0b
CCAPM
3
DDH
-
ECOM
3
CAPP
3
CAPN
3
MAT
3
TOG
3
PWM
3
ECCF
3
x000000
0b
CCAPM
4
DEH
-
ECOM
4
CAPP
4
CAPN
4
MAT
4
TOG
4
PWM
4
ECCF
4
x000000
0b
CCAPM PCA
0
Compare/CapCCAPM ture
Module Mode
1
Registers
CCAPM
2
T0-0.0 25093
1. Bit Addressable SFRs
©2013 Silicon Storage Technology, Inc.
DS25093B
21
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
SuperFlash Configuration Register (SFCF)
Location
7
6
5
4
3
2
1
0
Reset Value
B1H
-
IAPEN
-
-
-
-
SWR
BSEL
x0xxxx00b
Symbol Function
IAPEN
Enable IAP operation
0: IAP commands are disabled
1: IAP commands are enabled
SWR
Software Reset
See Section , “Software Reset”
BSEL
Program memory block switching bit
See Figure 6 and Table 3
SuperFlash Command Register (SFCM)
Location
7
6
5
4
3
2
1
0
Reset Value
B2H
FIE
FCM6
FCM5
FCM4
FCM3
FCM2
FCM1
FCM0
00H
Symbol Function
FIE
Flash Interrupt Enable.
0: INT1# is not reassigned.
1: INT1# is re-assigned to signal IAP operation completion.
External INT1# interrupts are ignored.
FCM[6:0] Flash operation command
000_0001b Chip-Erase
000_1011b Sector-Erase
000_1101b Block-Erase
000_1100b Byte-Verify1
000_1110b Byte-Program
000_1111b Prog-SB1
000_0011b Prog-SB2
000_0101b Prog-SB3
000_1001b Prog-SC0
000_1000bEnable-Clock-Double
All other combinations are not implemented, and reserved for future use.
1. Byte-Verify has a single machine cycle latency and will not generate any INT1# interrupt regardless of FIE.
SuperFlash Address Registers (SFAL)
Location
7
B3H
6
5
4
3
2
1
0
Reset Value
SuperFlash Low Order Byte Address Register
00H
Symbol Function
SFAL
Mailbox register for interfacing with flash memory block. (Low order address register).
©2013 Silicon Storage Technology, Inc.
DS25093B
22
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
SuperFlash Address Registers (SFAH)
Location
7
6
B4H
5
4
3
2
1
0
Reset Value
SuperFlash High Order Byte Address Register
00H
Symbol Function
SFAH
Mailbox register for interfacing with flash memory block. (High order address register).
SuperFlash Data Register (SFDT)
Location
7
6
5
B5H
4
3
2
1
0
Reset Value
SuperFlash Data Register
00H
Symbol Function
SFDT
Mailbox register for interfacing with flash memory block. (Data register).
SuperFlash Status Register (SFST) (Read Only Register)
Location
7
6
5
4
3
2
1
0
Reset Value
B6H
SB1_i
SB2_i
SB3_i
-
EDC_i
FLASH_BU
SY
-
-
xxxxx0xxb
Symbol Function
SB1_i
Security Bit 1 status (inverse of SB1 bit)
SB2_i
Security Bit 2 status (inverse of SB2 bit)
SB3_i
Security Bit 3 status (inverse of SB3 bit)
Please refer to Table 25 for security lock options.
EDC_i
Double Clock Status
0: 12 clocks per machine cycle
1: 6 clocks per machine cycle
FLASH_BUSYFlash operation completion polling bit.
0: Device has fully completed the last IAP command.
1: Device is busy with flash operation.
©2013 Silicon Storage Technology, Inc.
DS25093B
23
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Interrupt Enable (IE)
Location
7
6
5
4
3
2
1
0
Reset Value
A8H
EA
EC
ET2
ES
ET1
EX1
ET0
EX0
00H
Symbol Function
EA
Global Interrupt Enable.
0 = Disable
1 = Enable
EC
PCA Interrupt Enable.
ET2
Timer 2 Interrupt Enable.
ES
Serial Interrupt Enable.
ET1
Timer 1 Interrupt Enable.
EX1
External 1 Interrupt Enable.
ET0
Timer 0 Interrupt Enable.
EX0
External 0 Interrupt Enable.
Interrupt Enable A (IEA)
Location
7
6
5
4
3
2
1
0
Reset Value
E8H
-
-
-
-
EBO
-
-
-
xxxx0xxxb
Symbol Function
EBO
Brown-out Interrupt Enable.
1 = Enable the interrupt
0 = Disable the interrupt
©2013 Silicon Storage Technology, Inc.
DS25093B
24
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Interrupt Priority (IP)
Location
7
6
5
4
3
2
1
0
Reset Value
B8H
-
PPC
PT2
PS
PT1
PX1
PT0
PX0
x0000000b
Symbol Function
PPC
PCA interrupt priority bit
PT2
Timer 2 interrupt priority bit
PS
Serial Port interrupt priority bit
PT1
Timer 1 interrupt priority bit
PX1
External interrupt 1 priority bit
PT0
Timer 0 interrupt priority bit
PX0
External interrupt 0 priority bit
Interrupt Priority High (IPH)
Location
7
6
5
4
3
2
1
0
Reset Value
B7H
-
PPCH
PT2H
PSH
PT1H
PX1H
PT0H
PX0H
x0000000b
Symbol Function
PPCH
PCA interrupt priority bit high
PT2H
Timer 2 interrupt priority bit high
PSH
Serial Port interrupt priority bit high
PT1H
Timer 1 interrupt priority bit high
PX1H
External interrupt 1 priority bit high
PT0H
Timer 0 interrupt priority bit high
PX0H
External interrupt 0 priority bit high
Interrupt Priority 1 (IP1)
Location
7
6
5
4
3
2
1
0
Reset Value
F8H
1
-
-
1
PBO
PX3
PX2
1
1xx10001b
Symbol Function
PBO
Brown-out interrupt priority bit
PX2
External Interrupt 2 priority bit
PX3
External Interrupt 3 priority bit
Interrupt Priority 1 High (IP1H)
Location
7
6
5
4
3
2
1
0
Reset Value
F7H
1
-
-
1
PBOH
PX3H
PX2H
1
1xx10001b
Symbol Function
PBOH
Brown-out Interrupt priority bit high
PX2H
External Interrupt 2 priority bit high
PX3H
External Interrupt 3 priority bit high
©2013 Silicon Storage Technology, Inc.
DS25093B
25
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Auxiliary Register (AUXR)
Location
7
6
5
4
3
2
1
0
Reset Value
8EH
-
-
-
-
-
-
EXTRA
M
AO
xxxxxx00b
Symbol Function
EXTRAM Internal/External RAM access
0: Internal Expanded RAM access within range of 00H to 2FFH using MOVX @Ri / @DPTR.
Beyond 300H, the MCU always accesses external data memory.
For details, refer to Section , “Expanded Data RAM Addressing” .
1: External data memory access.
AO
Disable/Enable ALE
0: ALE is emitted at a constant rate of 1/3 the oscillator frequency in 6 clock mode, 1/6 fOSC in 12
clock mode.
1: ALE is active only during a MOVX or MOVC instruction.
Auxiliary Register 1 (AUXR1)
Location
7
6
5
4
3
2
1
0
Reset Value
A2H
-
-
-
-
GF2
0
-
DPS
xxxx00x0b
Symbol Function
GF2
General purpose user-defined flag.
DPS
DPTR registers select bit.
0: DPTR0 is selected.
1: DPTR1 is selected.
Watchdog Timer Control Register (WDTC)
Location
7
6
5
4
3
2
1
0
Reset Value
C0H
-
-
-
WDOUT
WDRE
WDTS
WDT
SWDT
xxx00000b
Symbol Function
WDOUT Watchdog output enable.
0: Watchdog reset will not be exported on Reset pin.
1: Watchdog reset if enabled by WDRE, will assert Reset pin for 32 clocks.
WDRE
Watchdog timer reset enable.
0: Disable watchdog timer reset.
1: Enable watchdog timer reset.
WDTS
Watchdog timer reset flag.
0: External hardware reset or power-on reset clears the flag.
Flag can also be cleared by writing a 1.
Flag survives if chip reset happened because of watchdog timer overflow.
1: Hardware sets the flag on watchdog overflow.
WDT
Watchdog timer refresh.
0: Hardware resets the bit when refresh is done.
1: Software sets the bit to force a watchdog timer refresh.
SWDT
Start watchdog timer.
0: Stop WDT.
1: Start WDT.
©2013 Silicon Storage Technology, Inc.
DS25093B
26
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Watchdog Timer Data/Reload Register (WDTD)
Location
7
6
5
85H
4
3
2
1
0
Reset Value
Watchdog Timer Data/Reload
00H
Symbol Function
WDTD
Initial/Reload value in Watchdog Timer. New value won’t be effective until WDT is set.
PCA Timer/Counter Control Register1 (CCON)
Location
7
6
5
4
3
2
1
0
Reset Value
D8H
CF
CR
-
CCF4
CCF3
CCF2
CCF1
CCF0
00x00000b
1. Bit addressable
Symbol Function
CF
PCA Counter Overflow Flag
Set by hardware when the counter rolls over. CF flags an interrupt if bit ECF in CMOD is set.
CF may be set by either hardware or software, but can only cleared by software.
CR
PCA Counter Run control bit
Set by software to turn the PCA counter on. Must be cleared by software to turn the PCA
counter off.
-
Not implemented, reserved for future use.
Note: User should not write ‘1’s to reserved bits. The value read from a reserved bit is indeterminate.
CCF4
PCA Module 4 interrupt flag. Set by hardware when a match or capture occurs.
Must be cleared by software.
CCF3
PCA Module 3 interrupt flag. Set by hardware when a match or capture occurs.
Must be cleared by software.
CCF2
PCA Module 2 interrupt flag. Set by hardware when a match or capture occurs.
Must be cleared by software.
CCF1
PCA Module 1 interrupt flag. Set by hardware when a match or capture occurs.
Must be cleared by software.
CCF0
PCA Module 0 interrupt flag. Set by hardware when a match or capture occurs.
Must be cleared by software.
©2013 Silicon Storage Technology, Inc.
DS25093B
27
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
PCA Timer/Counter Mode Register1 (CMOD)
Location
D9H
7
6
5
4
3
2
1
0
Reset Value
CIDL
WDTE
-
-
-
CPS1
CPS0
ECF
00xxx000b
1. Not bit addressable
Symbol Function
CIDL
Counter Idle Control:
0: Programs the PCA Counter to continue functioning during idle mode
1: Programs the PCA Counter to be gated off during idle
WDTE
Watchdog Timer Enable:
0: Disables Watchdog Timer function on PCA module 4
1: Enables Watchdog Timer function on PCA module 4
-
Not implemented, reserved for future use.
Note: User should not write ‘1’s to reserved bits. The value read from a reserved bit is indeterminate.
CPS1
PCA Count Pulse Select bit 1
CPS0
PCA Count Pulse Select bit 2
CPS1
CPS0
Selected
PCA Input1
0
0
0
Internal clock, fOSC/6 in 6 clock mode (fOSC/12 in 12 clock mode)
0
1
1
Internal clock, fOSC/2 in 6 clock mode (fOSC/4 in 12 clock mode)
1
0
2
Timer 0 overflow
1
1
3
External clock at ECI/P1.2 pin
(max. rate = fOSC/4 in 6 clock mode, fOSC/8 in 12 clock mode)
1. fOSC = oscillator frequency
ECF
PCA Enable Counter Overflow interrupt:
0: Disables the CF bit in CCON
1: Enables CF bit in CCON to generate an interrupt
©2013 Silicon Storage Technology, Inc.
DS25093B
28
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
PCA Compare/Capture Module Mode Register1 (CCAPMn)
Location
7
6
5
4
3
2
1
0
Reset Value
DAH
-
ECOM0
CAPP0
CAPN0
MAT0
TOG0
PWM0
ECCF0
00xxx000b
DBH
-
ECOM1
CAPP1
CAPN1
MAT1
TOG1
PWM1
ECCF1
00xxx000b
DCH
-
ECOM2
CAPP2
CAPN2
MAT2
TOG2
PWM2
ECCF2
00xxx000b
DDH
-
ECOM3
CAPP3
CAPN3
MAT3
TOG3
PWM3
ECCF3
00xxx000b
-
ECOM4
CAPP4
CAPN4
MAT4
TOG4
PWM4
ECCF4
00xxx000b
DEH
1. Not bit addressable
Symbol Function
-
Not implemented, reserved for future use.
Note: User should not write ‘1’s to reserved bits. The value read from a reserved bit is indeterminate.
ECOMn Enable Comparator
0: Disables the comparator function
1: Enables the comparator function
CAPPn
Capture Positive
0: Disables positive edge capture on CEX[4:0]
1: Enables positive edge capture on CEX[4:0]
CAPNn Capture Negative
0: Disables negative edge capture on CEX[4:0]
1: Enables negative edge capture on CEX[4:0]
MATn
Match: Set ECOM[4:0] and MAT[4:0] to implement the software timer mode
0: Disables software timer mode
1: A match of the PCA counter with this module’s compare/capture register causes the
CCFn bit in CCON to be set, flagging an interrupt.
TOGn
Toggle
0: Disables toggle function
1: A match of the PCA counter with this module’s compare/capture register causes the
CEXn pin to toggle.
PWMn
Pulse Width Modulation mode
0: Disables PWM mode
1: Enables CEXn pin to be used as a pulse width modulated output
ECCFn
Enable CCF Interrupt
0: Disables compare/capture flag CCF[4:0] in the CCON register to generate an interrupt
request.
1: Enables compare/capture flag CCF[4:0] in the CCON register to generate an interrupt
request.
©2013 Silicon Storage Technology, Inc.
DS25093B
29
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
SPI Control Register (SPCR)
Location
7
6
5
4
3
2
1
0
Reset Value
D5H
SPIE
SPE
DORD
MSTR
CPOL
CPHA
SPR1
SPR0
00H
Symbol Function
SPIE
If both SPIE and ES are set to one, SPI interrupts are enabled.
SPE
SPI enable bit.
0: Disables SPI.
1: Enables SPI and connects SS#, MOSI, MISO, and SCK to pins P1.4, P1.5, P1.6, P1.7.
DORD
Data Transmission Order.
0: MSB first in data transmission.
1: LSB first in data transmission.
MSTR
Master/Slave select.
0: Selects Slave mode.
1: Selects Master mode.
CPOL
Clock Polarity
0: SCK is low when idle (Active High).
1: SCK is high when idle (Active Low).
CPHA
Clock Phase control bit. The CPHA bit with the CPOL bit control the clock and data
relationship between master and slave. See Figures 21 and 22.
0: Shift triggered on the leading edge of the clock.
1: Shift triggered on the trailing edge of the clock.
SPR1, SPR0SPI Clock Rate Select bits. These two bits control the SCK rate of the device configured
as master. SPR1 and SPR0 have no effect on the slave. The relationship between SCK and
the oscillator frequency, fOSC, is as follows:
SPR1
SPR0
SCK = fOSC divided by
0
0
1
1
0
1
0
1
4
16
64
128
SPI Status Register (SPSR)
Location
7
6
5
4
3
2
1
0
Reset Value
AAH
SPIF
WCOL
-
-
-
-
-
-
00xxxxxxb
Symbol Function
SPIF
SPI Interrupt Flag.
Upon completion of data transfer, this bit is set to 1.
If SPIE =1 and ES =1, an interrupt is then generated.
This bit is cleared by software.
WCOL
Write Collision Flag.
Set if the SPI data register is written to during data transfer.
This bit is cleared by software.
©2013 Silicon Storage Technology, Inc.
DS25093B
30
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
SPI Data Register (SPDR)
Location
7
6
5
4
86H
3
2
1
0
Reset Value
SPDR[7:0]
00H
Power Control Register (PCON)
Location
7
6
5
4
3
2
1
0
Reset Value
87H
SMOD1
SMOD0
BOF
POF
GF1
GF0
PD
IDL
00010000b
Symbol Function
SMOD1 Double Baud rate bit. If SMOD1 = 1, Timer 1 is used to generate the baud rate, and the serial
port is used in modes 1, 2, and 3.
SMOD0 FE/SM0 Selection bit.
0: SCON[7] = SM0
1: SCON[7] = FE,
BOF
Brown-out detection status bit, this bit will not be affected by any other reset. BOF should be
cleared by software. Power-on reset will also clear the BOF bit.
0: No brown-out.
1: Brown-out occurred
POF
Power-on reset status bit, this bit will not be affected by any other reset. POF should be
cleared by software.
0: No Power-on reset.
1: Power-on reset occurred
GF1
General-purpose flag bit.
GF0
General-purpose flag bit.
PD
Power-down bit, this bit is cleared by hardware after exiting from power-down mode.
0: Power-down mode is not activated.
1: Activates Power-down mode.
IDL
Idle mode bit, this bit is cleared by hardware after exiting from idle mode.
0: Idle mode is not activated.
1: Activates idle mode.
©2013 Silicon Storage Technology, Inc.
DS25093B
31
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Serial Port Control Register (SCON)
Location
7
6
5
4
3
2
1
0
Reset Value
98H
SM0/FE
SM1
SM2
REN
TB8
RB8
TI
RI
00000000b
Symbol Function
FE
Set SMOD0 = 1 to access FE bit.
0: No framing error
1: Framing Error. Set by receiver when an invalid stop bit is detected. This bit needs to be
cleared by software.
SM0
SMOD0 = 0 to access SM0 bit.
Serial Port Mode Bit 0
SM1
Serial Port Mode Bit 1
SM0
0
SM1
0
Mode
0
Description
Shift Register
0
1
1
0
1
2
8-bit UART
9-bit UART
1
1
3
9-bit UART
Baud Rate1
fOSC/6 (6 clock mode) or
fOSC/12 (12 clock mode)
Variable
fOSC/32 or fOSC/16 (6 clock mode) or
fOSC/64 or fOSC/32 (12 clock mode)
Variable
1. fOSC = oscillator frequency
SM2
Enables the Automatic Address Recognition feature in Modes 2 or 3. If SM2 = 1 then RI will
not be set unless the received 9th data bit (RB8) is 1, indicating an address, and the received
byte is a given or broadcast address. In Mode 1, if SM2 = 1 then RI will not be activated
unless a valid stop bit was received. In Mode 0, SM2 should be 0.
REN
Enables serial reception.
0: to disable reception.
1: to enable reception.
TB8
The 9th data bit that will be transmitted in Modes 2 and 3. Set or clear by software as
desired.
RB8
In Modes 2 and 3, the 9th data bit that was received. In Mode 1, if SM2 = 0, RB8 is the stop
bit that was received. In Mode 0, RB8 is not used.
TI
Transmit interrupt flag. Set by hardware at the end of the 8th bit time in Mode 0, or at the
beginning of the stop bit in the other modes, in any serial transmission, Must be cleared by
software.
RI
Receive interrupt flag. Set by hardware at the end of the8th bit time in Mode 0, or halfway
through the stop bit time in the other modes, in any serial reception (except see SM2). Must
be cleared by software.
©2013 Silicon Storage Technology, Inc.
DS25093B
32
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Timer/Counter 2 Control Register (T2CON)
Location
7
6
5
4
3
2
1
0
Reset Value
C8H
TF2
EXF2
RCLK
TCLK
EXEN2
TR2
C/T2#
CP/
RL2#
00H
Symbol Function
TF2
Timer 2 overflow flag set by a Timer 2 overflow and must be cleared by software. TF2 will not
be set when either RCLK or TCLK = 1.
EXF2
Timer 2 external flag set when either a capture or reload is caused by a negative transition
on T2EX and EXEN2 = 1. When Timer 2 interrupt is enabled, EXF2 = 1 will cause the CPU
to vector to the Timer 2 interrupt routine. EXF2 must be cleared by software. EXF2 does not
cause an interrupt in up/down counter mode (DCEN = 1).
RCLK
Receive clock flag. When set, causes the serial port to use Timer 2 overflow pulses for its
receive clock in modes 1 and 3. RCLK = 0 causes Timer 1 overflow to be used for the receive
clock.
TCLK
Transmit clock flag. When set, causes the serial port to use Timer 2 overflow pulses for its
transmit clock in modes 1 and 3. TCLK = 0 causes Timer 1 overflow to be used for the
transmit clock.
EXEN2
Timer 2 external enable flag. When set, allows a capture or reload to occur as a result of a
negative transition on T2EX if Timer 2 is not being used to clock the serial port. EXEN2 = 0
causes Timer 2 to ignore events at T2EX.
TR2
Start/stop control for Timer 2. A logic 1 starts the timer.
C/T2#
Timer or counter select (Timer 2)
0: Internal timer (OSC/6 in 6 clock mode, OSC/12 in 12 clock mode)
1: External event counter (falling edge triggered)
CP/RL2# Capture/Reload flag. When set, captures will occur on negative transitions at T2EX if EXEN2
= 1. When cleared, auto-reloads will occur either with Timer 2 overflows or negative
transitions at T2EX when EXEN2 = 1. When either RCLK = 1 or TCLK = 1, this bit is ignored
and the timer is forced to auto-reload on Timer 2 overflow.
Timer/Counter 2 Mode Control (T2MOD)
Location
7
6
5
4
3
2
1
0
Reset Value
C9H
-
-
-
-
-
-
T2OE
DCEN
xxxxxx00b
Symbol Function
-
Not implemented, reserved for future use.
Note: User should not write ‘1’s to reserved bits. The value read from a reserved bit is indeterminate.
T2OE
Timer 2 Output Enable bit.
DCEN
Down Count Enable bit. When set, this allows Timer 2 to be configured as an up/down
counter.
©2013 Silicon Storage Technology, Inc.
DS25093B
33
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
External Interrupt Control (XICON)
Location
7
6
5
4
3
2
1
0
Reset Value
AEH
-
EX3
IE3
IT3
0
EX2
IE2
IT2
00H
Symbol Function
EX2
External Interrupt 2
Enable bit if set
IE2
Interrupt Enable
If IT2=1, IE2 is set/cleared automatically by hardware when interrupt is detected/serviced.
IT2
External Interrupt 2 is falling-edge/low-level triggered when this bit is cleared by software.
EX3
External Interrupt 3
Enable bit if set
IE3
Interrupt Enable
If IT3=1, IE3 is set/cleared automatically by hardware when interrupt is detected/serviced.
IT3
External Interrupt3 is falling-edge/low-level triggered when this bit is cleared by software.
©2013 Silicon Storage Technology, Inc.
DS25093B
34
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Flash Memory Programming
The device internal flash memory can be programmed or erased using In-Application Programming
(IAP) mode
Product Identification
The Read-ID command accesses the Signature Bytes that identify the device and the manufacturer as
SST. External programmers primarily use these Signature Bytes in the selection of programming algorithms.
Table 12: Product Identification
Address
Data
30H
BFH
SST89E516RD2/RD
31H
93H
SST89V516RD2/RD
31H
92H
Manufacturer’s ID
Device ID
T0-0.0 25093
In-Application Programming Mode
The device offers either 72 KByte of in-application programmable flash memory. During in-application
programming, the CPU of the microcontroller enters IAP mode. The two blocks of flash memory allow
the CPU to execute user code from one block, while the other is being erased or reprogrammed concurrently. The CPU may also fetch code from an external memory while all internal flash is being reprogrammed. The mailbox registers (SFST, SFCM, SFAL, SFAH, SFDT and SFCF) located in the special
function register (SFR), control and monitor the device’s erase and program process.
Table 14 outline the commands and their associated mailbox register settings.
In-Application Programming Mode Clock Source
During IAP mode, both the CPU core and the flash controller unit are driven off the external clock.
However, an internal oscillator will provide timing references for Program and Erase operations. The
internal oscillator is only turned on when required, and is turned off as soon as the flash operation is
completed.
Memory Bank Selection for In-Application Programming Mode
With the addressing range limited to 16 bit, only 64 KByte of program address space is “visible” at any
one time. As shown in Table 13, the bank selection (the configuration of EA# and SFCF[1:0]), allows
Block 1 memory to be overlaid on the lowest 8 KByte of Block 0 memory, making Block 1 reachable.
The same concept is employed to allow both Block 0 and Block 1 flash to be accessible to IAP operations. Code from a block that is not visible may not be used as a source to program another address.
However, a block that is not “visible” may be programmed by code from the other block through mailbox
registers.
The device allows IAP code in one block of memory to program the other block of memory, but may not
program any location in the same block. If an IAP operation originates physically from Block 0, the target of this operation is implicitly defined to be in Block 1. If the IAP operation originates physically from
©2013 Silicon Storage Technology, Inc.
DS25093B
35
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Block 1, then the target address is implicitly defined to be in Block 0. If the IAP operation originates
from external program space, then, the target will depend on the address and the state of bank selection.
IAP Enable Bit
The IAP enable bit, SFCF[6], enables in-application programming mode. Until this bit is set, all flash
programming IAP commands will be ignored.
Table 13: IAP Address Resolution
EA#
SFCF[1:0]
Address of IAP Inst.
Target Address
Block Being
Programmed
1
00
>= 2000H (Block 0)
>= 2000H (Block 0)
None1
1
00
>= 2000H (Block 0)
< 2000H (Block 1)
Block 1
1
00
< 2000H (Block 1)
Any (Block 0)
Block 0
1
01, 10, 11
Any (Block 0)
>= 2000H (Block 0)
None1
1
01, 10, 11
Any (Block 0)
< 2000H (Block 1)
Block 1
0
00
From external
>= 2000H (Block 0)
Block 0
0
00
From external
< 2000H (Block 1)
Block 1
0
01, 10, 11
From external
Any (Block 0)
Block 0
T0-0.0 25093
1. No operation is performed because code from one block may not program the same originating block
In-Application Programming Mode Commands
All of the following commands can only be initiated in the IAP mode. In all situations, writing the control
byte to the SFCM register will initiate all of the operations. All commands will not be enabled if the
security locks are enabled on the selected memory block.
The Program command is for programming new data into the memory array. The portion of the memory array to be programmed should be in the erased state, FFH. If the memory is not erased, it should
first be erased with an appropriate Erase command. Warning: Do not attempt to write (program or
erase) to a block that the code is currently fetching from. This will cause unpredictable program
behavior and may corrupt program data.
©2013 Silicon Storage Technology, Inc.
DS25093B
36
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Chip-Erase
The Chip-Erase command erases all bytes in both memory blocks. This command is only allowed
when EA#=0 (external memory execution). Additionally this command is not permitted when the
device is in level 4 locking. In all other instances, this command ignores the Security Lock status and
will erase the security lock bits and re-map bits.
IAP Enable
ORL SFCF, #40H
Set-Up
MOV SFDT, #55H
Polling scheme
MOV SFCM, #01H
Interrupt scheme
MOV SFCM, #81H
SFST[2] indicates
operation completion
INT1 interrupt
indicates completion
1273 F05.0
Figure 9: Chip Erase
Block-Erase
The Block-Erase command erases all bytes in one of two memory blocks (Block 0 or Block 1). The
selection of the memory block to be erased is determined by the SFCF[1:0]. The Block-Erase command sequence for SST89x516RDx is as follows:
IAP Enable
ORL SFCF, #40H
Select Block
*
Configure SFCF[1:0]
Set-Up
MOV SFDT, #55H
Polling scheme
MOV SFCM, #0DH
Interrupt scheme
MOV SFCM, #8DH
SFST[2] indicates
operation completion
INT1 interrupt
indicates completion
1273 F06.0
Note: * see Table 13
Figure 10:Block Erase
©2013 Silicon Storage Technology, Inc.
DS25093B
37
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Sector-Erase
The Sector-Erase command erases all of the bytes in a sector. The sector size for the flash memory blocks is
128 Bytes. The selection of the sector to be erased is determined by the contents of SFAH and SFAL.
IAP Enable
ORL SFCF, #40H
Program sector address
MOV SFAH, #sector_addressH
MOV SFAL, #sector_addressL
Polling scheme
MOV SFCM, #0BH
Interrupt scheme
MOV SFCM, #8BH
SFST[2] indicates
operation completion
INT1 interrupt
indicates completion
1273 F07.0
Figure 11:Sector Erase
Byte-Program
The Byte-Program command programs data into a single byte. The address is determined by the contents of SFAH and SFAL. The data byte is in SFDT.
IAP Enable
ORL SFCF, #40H
Program byte address
MOV SFAH, #byte_addressH
MOV SFAL, #byte_addressL
Move data to SFDT
MOV SFDT, #data
Polling scheme
MOV SFCM, #0EH
Interrupt scheme
MOV SFCM, #8EH
SFST[2] indicates
operation completion
INT1 interrupt
indicates completion
1273 F08.0
Figure 12:Byte Program
©2013 Silicon Storage Technology, Inc.
DS25093B
38
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Byte-Verify
The Byte-Verify command allows the user to verify that the device has correctly performed an Erase or
Program command. Byte-Verify command returns the data byte in SFDT if the command is successful.
The user is required to check that the previous flash operation has fully completed before issuing a
Byte-Verify. Byte-Verify command execution time is short enough that there is no need to poll for command completion and no interrupt is generated.
IAP Enable
ORL SFCF, #40H
Program byte address
MOV SFAH, #byte_addressH
MOV SFAL, #byte_addressL
MOV SFCM, #0CH
SFDT register
contains data
1273 F09.0
Figure 13:Byte Verify
Prog-SB3, Prog-SB2, Prog-SB1
Prog-SB3, Prog-SB2, Prog-SB1 commands are used to program the security bits (see Table 25). Completion of any of these commands, the security options will be updated immediately.
Security bits previously in un-programmed state can be programmed by these commands. Prog-SB3,
Prog-SB2 and Prog-SB1 commands should only reside in Block 1 or external code memory.
IAP Enable
ORL SFCF, #40H
Set-Up
MOV SFDT, #0AAH
Program SB1
MOV SFCM, #0FH
or
MOV SFCM, #8FH
Program SB2
OR
MOV SFCM, #03H
or
MOV SFCM, #83H
Polling SFST[2]
indicates completion
OR
Program SB3
MOV SFCM, #05H
or
MOV SFCM, #85H
INT1# Interrupt
indicates completion
1273 F10.0
Figure 14:Prog-SB3, Prog-SB2, Prog-SB1
©2013 Silicon Storage Technology, Inc.
DS25093B
39
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Prog-SC0
Prog-SC0 command is used to program the SC0 bit. This command only changes the SC0 bit and has
no effect on BSEL bit until after a reset cycle.
SC0 bit previously in un-programmed state can be programmed by this command. The Prog-SC0 command should reside only in Block 1 or external code memory.
IAP Enable
ORL SFCF, #40H
Set-up Program SC0
MOV SFAH, #5AH
MOV SFDT, #0AAH
Program SC0
Polling scheme
MOV SFCM, #09H
Program SC0
Interrupt scheme
MOV SFCM, #89H
Polling SFST[2]
indicates completion
INT1# Interrupt
indicates completion
1273 F11.0
Figure 15:Prog-SC0
Enable-Clock-Double
Enable-Clock-Double command is used to make the MCU run at 6 clocks per machine cycle. The standard (default) is 12 clocks per machine cycle (i.e. clock double command disabled).
IAP Enable
ORL SFCF, #40H
Set-up Enable-Clock-Double
MOV SFAH, #55H
MOV SFDT, #0AAH
Program Enable-Clock-Double
Polling scheme
MOV SFCM, #08H
Polling SFST[2]
indicates completion
Program Enable-Clock-Double
Interrupt scheme
MOV SFCM, #88H
INT1# Interrupt
indicates completion
1273 F12.0
Figure 16:Enable-Clock-Double
There are no IAP counterparts for the external host commands Select-Block0 and Select-Block1.
©2013 Silicon Storage Technology, Inc.
DS25093B
40
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Polling
A command that uses the polling method to detect flash operation completion should poll on the
FLASH_BUSY bit (SFST[2]). When FLASH_BUSY de-asserts (logic 0), the device is ready for the next
operation.
MOVC instruction may also be used for verification of the Programming and Erase operation of the
flash memory. MOVC instruction will fail if it is directed at a flash block that is still busy.
Interrupt Termination
If interrupt termination is selected, (SFCM[7] is set), then an interrupt (INT1) will be generated to indicate flash operation completion. Under this condition, the INT1 becomes an internal interrupt source.
The INT1# pin can now be used as a general purpose port pin and it cannot be the source of External
Interrupt 1 during in-application programming.
In order to use an interrupt to signal flash operation termination. EX1 and EA bits of IE register must be
set. The IT1 bit of TCON register must also be set for edge trigger detection.
.
Table 14: IAP Commands1
SFCM [6:0]2
Operation
Chip-Erase3
Block-Erase5
SFDT [7:0]
SFAH [7:0]
SFAL [7:0]
01H
55H
X4
X
0DH
55H
AH
X
AL7
Sector-Erase5
0BH
X
AH6
Byte-Program5
0EH
DI8
AH
AL
0CH
DO8
AH
AL
Prog-SB19
0FH
AAH
X
X
Prog-SB29
03H
AAH
X
X
Prog-SB39
05H
AAH
X
X
Prog-SC09
09H
AAH
5AH
X
Enable-Clock-Double9
08H
AAH
55H
X
Byte-Verify
(Read)5
T0-0.0 25093
1. SFCF[6]=1 enables IAP commands; SFCF[6]=0 disables IAP commands.
2. Interrupt/Polling enable for flash operation completion
SFCM[7] =1: Interrupt enable for flash operation completion
0: polling enable for flash operation completion
3. Chip-Erase only functions in IAP mode when EA#=0 (external memory execution) and device is not in level 4 locking.
4. X can be VIL or VIH, but no other value.
5. Refer to Table 13 for address resolution
6. AH = Address high order byte
7. AL = Address low order byte
8. DI = Data Input, DO = Data Output, all other values are in hex.
9. Instruction must be located in Block 1 or external code memory.
Note: DISIAPL pin in PLCC or TQFP will also disable IAP commands if it is externally pulled low when reset.
©2013 Silicon Storage Technology, Inc.
DS25093B
41
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Timers/Counters
Timers
The device has three 16-bit registers that can be used as either timers or event counters. The three
timers/counters are denoted Timer 0 (T0), Timer 1 (T1), and Timer 2 (T2). Each is designated a pair of
8-bit registers in the SFRs. The pair consists of a most significant (high) byte and least significant (low)
byte. The respective registers are TL0, TH0, TL1, TH1, TL2, and TH2.
Timer Set-up
Refer to Table 9 for TMOD, TCON, and T2CON registers regarding timers T0, T1, and T2. The following tables provide TMOD values to be used to set up Timers T0, T1, and T2.
Except for the baud rate generator mode, the values given for T2CON do not include the setting of the
TR2 bit. Therefore, bit TR2 must be set separately to turn the timer on.
Table 15: Timer/Counter 0
TMOD
Used as Timer
Used as
Counter
Mode
Function
Internal Control1
External Control2
0
13-bit Timer
00H
08H
1
16-bit Timer
01H
09H
2
8-bit Auto-Reload
02H
0AH
3
Two 8-bit Timers
03H
0BH
0
13-bit Timer
04H
0CH
1
16-bit Timer
05H
0DH
2
8-bit Auto-Reload
06H
0EH
3
Two 8-bit Timers
07H
0FH
T0-0.0 25093
1. The Timer is turned ON/OFF by setting/clearing bit TR0 in the software.
2. The Timer is turned ON/OFF by the 1 to 0 transition on INT0# (P3.2) when TR0 = 1 (hardware control).
Table 16: Timer/Counter 1
TMOD
Used as Timer
Used as
Counter
Mode
Function
Internal Control1
External Control2
0
13-bit Timer
00H
80H
1
16-bit Timer
10H
90H
2
8-bit Auto-Reload
20H
A0H
3
Does not run
30H
B0H
0
13-bit Timer
40H
C0H
1
16-bit Timer
50H
D0H
2
8-bit Auto-Reload
60H
E0H
3
Not available
-
T0-0.0 25093
1. The Timer is turned ON/OFF by setting/clearing bit TR1 in the software.
2. The Timer is turned ON/OFF by the 1 to 0 transition on INT1# (P3.3) when TR1 = 1 (hardware control).
©2013 Silicon Storage Technology, Inc.
DS25093B
42
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Table 17: Timer/Counter 2
T2CON
Mode
Used as Timer
Internal
Control1
External Control2
16-bit Auto-Reload
00H
08H
16-bit Capture
01H
09H
Baud rate generator receive and transmit
same baud rate
34H
36H
Receive only
24H
26H
Used as Counter
Transmit only
14H
16H
16-bit Auto-Reload
02H
0AH
16-bit Capture
03H
0BH
T0-0.0 25093
1. Capture/Reload occurs only on timer/counter overflow.
2. Capture/Reload occurs on timer/counter overflow and a 1 to 0 transition on T2EX (P1.1) pin except when Timer 2 is
used in the baud rate generating mode.
Programmable Clock-Out
A 50% duty cycle clock can be programmed to come out on P1.0. This pin, besides being a regular I/O
pin, has two alternate functions. It can be programmed:
1.
to input the external clock for Timer/Counter 2, or
2.
to output a 50% duty cycle clock ranging from 122 Hz to 8 MHz at a 16 MHz operating frequency (61 Hz to 4 MHz in 12 clock mode).
To configure Timer/Counter 2 as a clock generator, bit
C/#T2 (in T2CON) must be cleared and bit T20E in T2MOD must be set. Bit TR2 (T2CON.2) also must
be set to start the timer.
The Clock-Out frequency depends on the oscillator frequency and the reload value of Timer 2 capture
registers (RCAP2H, RCAP2L) as shown in this equation:
Oscillator Frequency
n x (65536 - RCAP2H, RCAP2L)
n =2 (in 6 clock mode)
4 (in 12 clock mode)
Where (RCAP2H, RCAP2L) = the contents of RCAP2H and RCAP2L taken as a 16-bit unsigned integer.
In the Clock-Out mode, Timer 2 roll-overs will not generate an interrupt. This is similar to when it is
used as a baud-rate generator. It is possible to use Timer 2 as a baud-rate generator and a clock generator simultaneously. Note, however, that the baud-rate and the Clock-Out frequency will not be the
same.
©2013 Silicon Storage Technology, Inc.
DS25093B
43
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Serial I/O
Full-Duplex, Enhanced UART
The device serial I/O port is a full-duplex port that allows data to be transmitted and received simultaneously in hardware by the transmit and receive registers, respectively, while the software is performing other tasks. The transmit and receive registers are both located in the Serial Data Buffer (SBUF)
special function register. Writing to the SBUF register loads the transmit register, and reading from the
SBUF register obtains the contents of the receive register.
The UART has four modes of operation which are selected by the Serial Port Mode Specifier (SM0 and
SM1) bits of the Serial Port Control (SCON) special function register. In all four modes, transmission is
initiated by any instruction that uses the SBUF register as a destination register. Reception is initiated
in mode 0 when the Receive Interrupt (RI) flag bit of the Serial Port Control (SCON) SFR is cleared
and the Reception Enable/ Disable (REN) bit of the SCON register is set. Reception is initiated in the
other modes by the incoming start bit if the REN bit of the SCON register is set.
Framing Error Detection
Framing Error Detection is a feature, which allows the receiving controller to check for valid stop bits in
modes 1, 2, or 3. Missing stops bits can be caused by noise in serial lines or from simultaneous transmission by two CPUs.
Framing Error Detection is selected by going to the PCON register and changing SMOD0 = 1 (see Figure 17). If a stop bit is missing, the Framing Error bit (FE) will be set. Software may examine the FE bit
after each reception to check for data errors. After the FE bit has been set, it can only be cleared by
software. Valid stop bits do not clear FE. When FE is enabled, RI rises on the stop bit, instead of the
last data bit (see Figure 18 and Figure 19).
SM0/FE
SM1
SM2
REN
TB8
RB8
TI
RI
SCON
(98H)
Set FE bit if stop bit is 0 (framing error) (SMOD0 = 1)
SM0 to UART mode control (SMOD0 = 0)
SMOD1 SMOD0
BOF
POF
GF1
GF0
PD
IDL
PCON
(87H)
To UART framing error control
1273 F13.0
Figure 17:Framing Error Block Diagram
©2013 Silicon Storage Technology, Inc.
DS25093B
44
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
RXD
D0
D1
D2
Start
bit
D3
D4
D5
D6
D7
Data byte
Stop
bit
RI
SMOD0=X
FE
SMOD0=1
1273 F14.0
Figure 18:UART Timings in Mode 1
RXD
D0
D1
D2
Start
bit
D3
D4
Data byte
D5
D6
D7
D8
Ninth
bit
Stop
bit
RI
SMOD0=0
RI
SMOD0=1
FE
SMOD0=1
1273 F15.0
Figure 19:UART Timings in Modes 2 and 3
Automatic Address Recognition
Automatic Address Recognition helps to reduce the MCU time and power required to talk to multiple
serial devices. Each device is hooked together sharing the same serial link with its own address. In this
configuration, a device is only interrupted when it receives its own address, thus eliminating the software overhead to compare addresses.
This same feature helps to save power because it can be used in conjunction with idle mode to reduce
the system’s overall power consumption. Since there may be multiple slaves hooked up serial to one
master, only one slave would have to be interrupted from idle mode to respond to the master’s transmission. Automatic Address Recognition (AAR) allows the other slaves to remain in idle mode while
only one is interrupted. By limiting the number of interruptions, the total current draw on the system is
reduced.
There are two ways to communicate with slaves: a group of them at once, or all of them at once. To
communicate with a group of slaves, the master sends out an address called the given address. To
communicate with all the slaves, the master sends out an address called the “broadcast” address.
AAR can be configured as mode 2 or 3 (9-bit modes) and setting the SM2 bit in SCON. Each slave has
its own SM2 bit set waiting for an address byte (9th bit = 1). The Receive Interrupt (RI) flag will only be
set when the received byte matches either the given address or the broadcast address. Next, the slave
then clears its SM2 bit to enable reception of the data bytes (9th bit = 0) from the master. When the 9th
bit = 1, the master is sending an address. When the 9th bit = 0, the master is sending actual data.
©2013 Silicon Storage Technology, Inc.
DS25093B
45
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
If mode 1 is used, the stop bit takes the place of the 9th bit. Bit RI is set only when the received command frame address matches the device’s address and is terminated by a valid stop bit. Note that
mode 0 cannot be used. Setting SM2 bit in the SCON register in mode 0 will have no effect.
Each slave’s individual address is specified by SFR SADDR. SFR SADEN is a mask byte that defines
“don’t care” bits to form the given address when combined with SADDR. See the example below:
Slave 1
SADDR =
1111 0001
SADEN =
1111 1010
GIVEN
= 1111 0X0X
Slave 2
SADDR =
1111 0011
SADEN =
1111 1001
GIVEN
= 1111 0XX1
Using the Given Address to Select Slaves
Any bits masked off by a 0 from SADEN become a “don’t care” bit for the given address. Any bit
masked off by a 1, becomes ANDED with SADDR. The “don’t cares” provide flexibility in the userdefined addresses to address more slaves when using the given address.
Shown in the example above, Slave 1 has been given an address of 1111 0001 (SADDR). The SADEN
byte has been used to mask off bits to a given address to allow more combinations of selecting Slave 1
and Slave 2. In this case for the given addresses, the last bit (LSB) of Slave 1 is a “don’t care” and the
last bit of Slave 2 is a 1. To communicate with Slave 1 and Slave 2, the master would need to send an
address with the last bit equal to 1 (e.g. 1111 0001) since Slave 1’s last bit is a don’t care and Slave 2’s
last bit has to be a 1. To communicate with Slave 1 alone, the master would send an address with the
last bit equal to 0 (e.g. 1111 0000), since Slave 2’s last bit is a 1. See the table below for other possible
combinations.
Select Slave 1 Only
Slave 1
Given Address
Possible Addresses
1111 0X0X
1111 0000
1111 0100
Select Slave 2 Only
Slave 2
Given Address
Possible Addresses
1111 0XX1
1111 0111
1111 0011
Select Slaves 1 & 2
Slaves 1 & 2
Possible Addresses
1111 0001
1111 0101
©2013 Silicon Storage Technology, Inc.
DS25093B
46
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
If the user added a third slave such as the example below:
Slave 3
SADDR = 1111 1001
SADEN = 1111 0101
GIVEN
= 1111 X0X1
Select Slave 3 Only
Slave 2
Given Address
Possible Addresses
1111 X0X1
1111 1011
1111 1001
The user could use the possible addresses above to select slave 3 only. Another combination could be
to select slave 2 and 3 only as shown below.
Select Slaves 2 & 3 Only
Slaves 2 & 3
Possible Addresses
1111 0011
More than one slave may have the same SADDR address as well, and a given address could be used
to modify the address so that it is unique.
Using the Broadcast Address to Select Slaves
Using the broadcast address, the master can communicate with all the slaves at once. It is formed by
performing a logical OR of SADDR and SADEN with ‘0’s in the result treated as “don’t cares”.
Slave 1
1111 0001 = SADDR
+1111 1010 = SADEN
1111 1X11 = Broadcast
“Don’t cares” allow for a wider range in defining the broadcast address, but in most cases, the broadcast address will be FFH.
On reset, SADDR and SADEN are “0”. This produces an given address of all “don’t cares” as well as a
broadcast address of all “don’t cares.” This effectively disables Automatic Addressing mode and allows
the microcontroller to function as a standard 8051, which does not make use of this feature.
©2013 Silicon Storage Technology, Inc.
DS25093B
47
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Serial Peripheral Interface
SPI Features
•
•
•
•
•
•
•
Master or slave operation
10 MHz bit frequency (max)
LSB first or MSB first data transfer
Four programmable bit rates
End of transmission (SPIF)
Write collision flag protection (WCOL)
Wake up from idle mode (slave mode only)
SPI Description
The serial peripheral interface (SPI) allows high-speed synchronous data transfer between the
SST89E/V516RDx and peripheral devices or between several SST89E/V516RDx devices.
Figure 20 shows the correspondence between master and slave SPI devices. The SCK pin is the clock
output and input for the master and slave modes, respectively. The SPI clock generator will start following a write to the master devices SPI data register. The written data is then shifted out of the MOSI pin
on the master device into the MOSI pin of the slave device. Following a complete transmission of one
byte of data, the SPI clock generator is stopped and the SPIF flag is set. An SPI interrupt request will
be generated if the SPI Interrupt Enable bit (SPIE) and the Serial Port Interrupt Enable bit (ES) are
both set.
An external master drives the Slave Select input pin, SS#/P1[4], low to select the SPI module as a
slave. If SS#/P1[4] has not been driven low, then the slave SPI unit is not active and the MOSI/P1[5]
port can also be used as an input port pin.
CPHA and CPOL control the phase and polarity of the SPI clock. Figures 21 and 22 show the four possible combinations of these two bits.
MSB Master LSB
MISO MISO
8-bit Shift Register
MSB Slave LSB
8-bit Shift Register
MOSI MOSI
SPI
Clock Generator
SCK
SCK
SS#
SS#
VDD VSS
1273 F16.0
Figure 20:SPI Master-slave Interconnection
©2013 Silicon Storage Technology, Inc.
DS25093B
48
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
SPI Transfer Formats
SCK Cycle #
(for reference)
1
2
3
4
5
6
7
8
SCK (CPOL=0)
SCK (CPOL=1)
MOSI
(from Master)
MISO
(from Slave)
MSB
MSB
6
5
4
3
2
1
LSB
6
5
4
3
2
1
LSB
SS# (to Slave)
1273 F17.0
Figure 21:SPI Transfer Format with CPHA = 0
SCK Cycle #
(for reference)
1
2
3
4
5
6
7
8
SCK (CPOL=0)
SCK (CPOL=1)
MOSI
(from Master)
MSB
6
5
4
3
2
1
MISO
(from Slave)
MSB
6
5
4
3
2
1
LSB
LSB
SS# (to Slave)
1273 F18.0
Figure 22:SPI Transfer Format with CPHA = 1
©2013 Silicon Storage Technology, Inc.
DS25093B
49
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Watchdog Timer
The device offers a programmable Watchdog Timer (WDT) for fail safe protection against software
deadlock and automatic recovery.
To protect the system against software deadlock, the user software must refresh the WDT within a
user-defined time period. If the software fails to do this periodical refresh, an internal hardware reset
will be initiated if enabled (WDRE= 1). The software can be designed such that the WDT times out if
the program does not work properly.
The WDT in the device uses the system clock (XTAL1) as its time base. So strictly speaking, it is a
watchdog counter rather than a watchdog timer. The WDT register will increment every 344,064 crystal
clocks. The upper 8-bits of the time base register (WDTD) are used as the reload register of the WDT.
The WDTS flag bit is set by WDT overflow and is not changed by WDT reset. User software can clear
WDTS by writing “1” to it.
Figure 23 provides a block diagram of the WDT. Two SFRs (WDTC and WDTD) control watchdog timer
operation. During idle mode, WDT operation is temporarily suspended, and resumes upon an interrupt
exit from idle.
The time-out period of the WDT is calculated as follows:
Period = (255 - WDTD) * 344064 * 1/fCLK (XTAL1)
where WDTD is the value loaded into the WDTD register and fOSC is the oscillator frequency.
CLK (XTAL1)
Counter
344064
clks
WDT Reset
WDT Upper Byte
Internal Reset
Ext. RST
WDTC
WDTD
1273 F19.0
Figure 23:Block Diagram of Programmable Watchdog Timer
©2013 Silicon Storage Technology, Inc.
DS25093B
50
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Programmable Counter Array
The Programmable Counter Array (PCA) present on the SST89E/V516RDx is a special 16-bit timer
that has five 16-bit capture/compare modules. Each of the modules can be programmed to operate in
one of four modes: rising and/or falling edge capture, software timer, high-speed output, or pulse width
modulator. The 5th module can be programmed as a Watchdog Timer in addition to the other four
modes. Each module has a pin associated with it in port 1. Module 0 is connected to P1.3 (CEX0),
module 1 to P1[4] (CEX1), module 2 to P1[5] (CEX2), module 3 to P1[6] (CEX3), and module 4 to
P1[7] (CEX4). PCA configuration is shown in Figure 24.
PCA Overview
PCA provides more timing capabilities with less CPU intervention than the standard timer/counter. Its
advantages include reduced software overhead and improved accuracy.
The PCA consists of a dedicated timer/counter which serves as the time base for an array of five compare/capture modules. Figure 24 shows a block diagram of the PCA. External events associated with
modules are shared with corresponding Port 1 pins. Modules not using the port pins can still be used
for standard I/O.
Each of the five modules can be programmed in any of the following modes:
•
•
•
•
•
Rising and/or falling edge capture
Software timer
High speed output
Watchdog Timer (Module 4 only)
Pulse Width Modulator (PWM)
PCA Timer/Counter
The PCA timer is a free-running 16-bit timer consisting of registers CH and CL (the high and low bytes
of the count values). The PCA timer is common time base for all five modules and can be programmed
to run at: 1/6 the oscillator frequency, 1/2 the oscillator frequency, Timer 0 overflow, or the input on the
ECI pin (P1.2). The timer/counter source is determined from the CPS1 and CPS0 bits in the CMOD
SFR as follows (see “PCA Timer/Counter Mode Register (CMOD)” on page 28):
Table 18: PCA Timer/Counter Source
CPS1
CPS0
12 Clock Mode
6 Clock Mode
0
0
fOSC /12
fOSC /6
0
1
fOSC /4
fOSC /2
1
0
Timer 0 overflow
Timer 0 overflow
1
1
External clock at ECI pin
(maximum rate = fOSC /8)
External clock at ECI pin
(maximum rate = fOSC /4)
T0-0.0 25093
©2013 Silicon Storage Technology, Inc.
DS25093B
51
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
16 Bits Each
Module 0
P1.3/CEX0
Module 1
P1.4/CEX1
Module 2
P1.5/CEX2
Module 3
P1.6/CEX3
Module 4
P1.7/CEX4
16 Bits
PCA Timer/Counter
1273 F20.0
Figure 24:PCA Timer/Counter and Compare/Capture Modules
The table below summarizes various clock inputs at two common frequencies.
Table 19: PCA Timer/Counter Inputs
Clock Increments
PCA Timer/Counter Mode
Mode 0: fOSC/12
12 MHz
16 MHz
1 µsec
0.75 µsec
330 nsec
250 nsec
8-bit mode
256 µsec
192 µsec
16-bit mode
65 msec
49 µsec
1 to 255 µsec
0.75 to 191 µsec
0.66 µsec
0.50 µsec
Mode 1:
Mode 2: Timer 0
Overflows1
Timer 0 programmed in:
8-bit auto-reload
Mode 3: External Input MAX
T0-0.0 25093
1. In Mode 2, the overflow interrupt for Timer 0 does not need to be enabled.
The four possible CMOD timer modes with and without the overflow interrupt enabled are shown
below. This list assumes that PCA will be left running during idle mode.
Table 20: CMOD Values
CMOD Value
PCA Count Pulse Selected
Without Interrupt Enabled
With Interrupt Enabled
Internal clock, fOSC/12
00H
01H
Internal clock, fOSC/4
02H
03H
Timer 0 overflow
04H
05H
External clock at P1.2
06H
07H
T0-0.0 25093
The CCON register is associated with all PCA timer functions. It contains run control bits and flags for
the PCA timer (CF) and all modules. To run the PCA the CR bit (CCON.6) must be set by software.
Clearing the bit, will turn off PCA. When the PCA counter overflows, the CF (CCON.7) will be set, and
©2013 Silicon Storage Technology, Inc.
DS25093B
52
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
an interrupt will be generated if the ECF bit in the CMOD register is set. The CF bit can only be cleared
by software. Each module has its own timer interrupt or capture interrupt flag (CCF0 for module 0,
CCF4 for module 4, etc.). They are set when either a match or capture occurs. These flags can only be
cleared by software. (See “PCA Timer/Counter Control Register (CCON)” on page 27.)
Compare/Capture Modules
Each PCA module has an associated SFR with it. These registers are: CCAPM0 for module 0, CCAPM1 for
module 1, etc. Refer to “PCA Compare/Capture Module Mode Register (CCAPMn)” on page 29 for details.
The registers each contain 7 bits which are used to control the mode each module will operate in. The ECCF
bit (CCAPMn.0 where n = 0, 1, 2, 3, or 4 depending on module) will enable the CCF flag in the CCON SFR to
generate an interrupt when a match or compare occurs. PWM (CCAPMn.1) enables the pulse width modulation mode. The TOG bit (CCAPMn.2) when set, causes the CEX output associated with the module to toggle
when there is a match between the PCA counter and the module’s capture/compare register. When there is a
match between the PCA counter and the module’s capture/compare register, the MATn (CCAPMn.3) and the
CCFn bit in the CCON register to be set.
Bits CAPN (CCAPMn.4) and CAPP (CCAPMn.5) determine whether the capture input will be active on a positive edge or negative edge. The CAPN bit enables the negative edge that a capture input will be active on,
and the CAPP bit enables the positive edge. When both bits are set, both edges will be enabled and a capture
will occur for either transition. The last bit in the register ECOM (CCAPMn.6) when set, enables the comparator function. Table 22 shows the CCAPMn settings for the various PCA functions.
There are two additional register associated with each of the PCA modules: CCAPnH and CCAPnL. They are
registers that hold the 16-bit count value when a capture occurs or a compare occurs. When a module is used
in PWM mode, these registers are used to control the duty cycle of the output. See Figure 24.
Table 21: PCA High and Low Register Compare/Capture Modules
Symbol Description
CCAP0H PCA Module 0
CCAP0L Compare/Capture Registers
CCAP1H PCA Module 1
CCAP1L Compare/Capture Registers
CCAP2H PCA Module 2
CCAP2L Compare/Capture Registers
CCAP3H PCA Module 3
CCAP3L Compare/Capture Registers
CCAP4H PCA Module 4
CCAP4L Compare/Capture Registers
Direct
Address
Bit Address, Symbol, or Alternative Port Function
MSB
FAH
LSB
RESET
Value
CCAP0H[7:0]
00H
EAH
CCAP0L[7:0]
00H
FBH
CCAP1H[7:0]
00H
EBH
CCAP1L[7:0]
00H
FCH
CCAP2H[7:0]
00H
ECH
CCAP2L[7:0]
00H
FDH
CCAP3H[7:0]
00H
EDH
CCAP3L[7:0]
00H
FEH
CCAP4H[7:0]
00H
EEH
CCAP4L[7:0]
00H
T0-0.0 25093
©2013 Silicon Storage Technology, Inc.
DS25093B
53
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Table 22: PCA Module Modes
Without Interrupt enabled
-1 ECOMy2 CAPPy2 CAPNy2 MATy2 TOGy2 PWMy2 ECCFy2 Module Code
-
0
0
0
0
0
0
0
No Operation
-
0
1
0
0
0
0
0
16-bit capture on positive-edge trigger at
CEX[4:0]
-
0
0
1
0
0
0
0
16-bit capture on negative-edge trigger at
CEX[4:0]
-
0
1
1
0
0
0
0
16-bit capture on positive/negative-edge
trigger at CEX[4:0]
-
1
0
0
1
0
0
0
Compare: software timer
-
1
0
0
1
1
0
0
Compare: high-speed output
-
1
0
0
0
0
1
0
Compare: 8-bit PWM
-
1
0
0
1
0 or
13
0
0
Compare: PCA WDT (CCAPM4 only)4
T0-0.0 25093
1.
2.
3.
4.
User should not write ‘1’s to reserved bits. The value read from a reserved bit is indeterminate.
y = 0, 1, 2, 3, 4
A 0 disables toggle function. A 1 enables toggle function on CEX[4:0] pin.
For PCA WDT mode, also set the WDTE bit in the CMOD register to enable the reset output signal.
Table 23: PCA Module Modes
With Interrupt enabled
-1 ECOMy2 CAPPy2 CAPNy2 MATy2 TOGy2 PWMy2 ECCFy2 Module Code
-
0
1
0
0
0
0
1
16-bit capture on positive-edge trigger at CEX[4:0]
-
0
0
1
0
0
0
1
16-bit capture on negative-edge trigger at CEX[4:0]
-
0
1
1
0
0
0
1
16-bit capture on positive/negativeedge
trigger at CEX[4:0]
-
1
0
0
1
0
0
1
Compare: software timer
-
1
0
0
1
1
0
1
Compare: high-speed output
-
1
0
0
0
0
1
X3
Compare: 8-bit PWM
-
1
0
0
1
0 or 14
0
X5
Compare: PCA WDT (CCAPM4
only)6
T0-0.0 25093
1.
2.
3.
4.
5.
6.
User should not write ‘1’s to reserved bits. The value read from a reserved bit is indeterminate.
y = 0, 1, 2, 3, 4
No PCA interrupt is needed to generate the PWM.
A 0 disables toggle function. A 1 enables toggle function on CEX[4:0] pin.
Enabling an interrupt for the Watchdog Timer would defeat the purpose of the Watchdog Timer.
For PCA WDT mode, also set the WDTE bit in the CMOD register to enable the reset output signal.
©2013 Silicon Storage Technology, Inc.
DS25093B
54
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Capture Mode
Capture mode is used to capture the PCA timer/counter value into a module’s capture registers
(CCAPnH and CCAPnL). The capture will occur on a positive edge, negative edge, or both on the corresponding module’s pin. To use one of the PCA modules in the capture mode, either one or both the
CCAPM bits CAPN and CAPP for that module must be set. When a valid transition occurs on the CEX
pin corresponding to the module used, the PCA hardware loads the 16-bit value of the PCA counter
register (CH and CL) into the module’s capture registers (CCAPnL and CCAPnH). If the CCFn bit for
the module in the CCON SFR and the ECCFn bit in the CCAPMn SFR are set, then an interrupt will be
generated. In the interrupt service routine, the 16-bit capture value must be saved in RAM before the
next event capture occurs. If a subsequent capture occurred, the original capture values would be lost.
After flag event flag has been set by hardware, the user must clear the flag in software. (See Figure 25)
CCON
CF
CR
CCF4
CCF3
CCF2
CCF1
CCF0
PCA Interrupt
PCA Timer/Counter
CH
CL
CCAPnH
CCAPnL
Capture
CEXn
CCAPMn
n=0 to 4
ECOMn CAPPn CAPNn MATn
0
0
TOGn
0
PWMn ECCFn
1273 F21.0
0
Figure 25:PCA Capture Mode
©2013 Silicon Storage Technology, Inc.
DS25093B
55
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
16-Bit Software Timer Mode
The 16-bit software timer mode is used to trigger interrupt routines, which must occur at periodic intervals. It is setup by setting both the ECOM and MAT bits in the module’s CCAPMn register. The PCA
timer will be compared to the module’s capture registers (CCAPnL and CCAPnH) and when a match
occurs, an interrupt will occur, if the CCFn (CCON SFR) and the ECCFn (CCAPMn SFR) bits for the
module are both set.
If necessary, a new 16-bit compare value can be loaded into CCAPnH and CCAPnL during the interrupt routine. The user should be aware that the hardware temporarily disables the comparator function
while these registers are being updated so that an invalid match will not occur. Thus, it is recommended that the user write to the low byte first (CCAPnL) to disable the comparator, then write to the
high byte (CCAPnH) to re-enable it. If any updates to the registers are done, the user may want to hold
off any interrupts from occurring by clearing the EA bit. (See Figure 26)
CF
Write to
CCAPnL
CCF4
CCF3
CCF2
CCF1
CCF0
CCON
Reset
Write to
CCAPnH
1
CR
CCAPnH
PCA Interrupt
CCAPnL
0
Enable
Match
16-bit Comparator
CH
CL
PCA Timer/Counter
ECOMn CAPPn CAPNn
0
0
MATn
TOGn
0
PWMn ECCFn
CCAPMn
n=0 to 4
0
1273 F22.0
Figure 26:PCA Compare Mode (Software Timer)
High Speed Output Mode
The high speed output mode is used to toggle a port pin when a match occurs between the PCA timer
and the preloaded value in the compare registers. In this mode, the CEX output pin (on port 1) associated with the PCA module will toggle every time there is a match between the PCA counter (CH and
CL) and the capture registers (CCAPnH and CCAPnL). To activate this mode, the user must set TOG,
MAT, and ECOM bits in the module’s CCAPMn SFR.
High speed output mode is much more accurate than toggling pins since the toggle occurs before
branching to an interrupt. In this case, interrupt latency will not affect the accuracy of the output. When
using high speed output, using an interrupt is optional. Only if the user wishes to change the time for
the next toggle is it necessary to update the compare registers. Otherwise, the next toggle will occur
when the PCA timer rolls over and matches the last compare value. (See Figure 27)
©2013 Silicon Storage Technology, Inc.
DS25093B
56
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
CF
Write to
CCAPnL
CCF4
CCF3
CCF2
CCF1
CCF0
CCON
Reset
Write to
CCAPnH
1
CR
CCAPnH
PCA Interrupt
CCAPnL
0
Enable
Match
16-bit Comparator
Toggle
CH
CEXn
CL
PCA Timer/Counter
ECOMn CAPPn CAPNn
0
MATn
0
TOGn
PWMn ECCFn
CCAPMn
n=0 to 4
0
1273 F23.0
Figure 27:PCA High Speed Output Mode
Pulse Width Modulator
The Pulse Width Modulator (PWM) mode is used to generate 8-bit PWMs by comparing the low byte of
the PCA timer (CL) with the low byte of the compare register (CCAPnL). When CL < CCAPnL the output is low. When CL ≥ CCAPnL the output is high. To activate this mode, the user must set the PWM
and ECOM bits in the module’s CCAPMn SFR. (See Figure 28 and Table 24)
In PWM mode, the frequency of the output depends on the source for the PCA timer. Since there is
only one set of CH and CL registers, all modules share the PCA timer and frequency. Duty cycle of the
output is controlled by the value loaded into the high byte (CCAPnH). Since writes to the CCAPnH register are asynchronous, a new value written to the high byte will not be shifted into CCAPnL for comparison until the next period of the output (when CL rolls over from 255 to 00).
To calculate values for CCAPnH for any duty cycle, use the following equation:
CCAPnH = 256(1 - Duty Cycle)
where CCAPnH is an 8-bit integer and Duty Cycle is a fraction.
©2013 Silicon Storage Technology, Inc.
DS25093B
57
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
CCAPnH
CCAPnL
0
CL < CCAPnL
Enable
8-bit Comparator
CEXn
CL >= CCAPnL
1
CL
Overflow
PCA Timer/Counter
ECOMn CAPPn CAPNn
MATn
TOGn
0
0
0
0
PWMn ECCFn
CCAPMn
n=0 to 4
0
1273 F24.0
Figure 28:PCA Pulse Width Modulator Mode
Table 24: Pulse Width Modulator Frequencies
PWM Frequency
PCA Timer Mode
12 MHz
16 MHz
1/12 Oscillator Frequency
3.9 KHz
5.2 KHz
1/4 Oscillator Frequency
11.8 KHz
15.6 KHz
8-bit
15.5 Hz
20.3 Hz
16-bit
0.06 Hz
0.08 Hz
3.9 KHz to 15.3 Hz
5.2 KHz to 20.3 Hz
5.9 KHz
7.8 KHz
Timer 0 Overflow:
8-bit Auto-Reload
External Input (Max)
T0-0.0 25093
©2013 Silicon Storage Technology, Inc.
DS25093B
58
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Watchdog Timer
The Watchdog Timer mode is used to improve reliability in the system without increasing chip count
(See Figure 29). Watchdog Timers are useful for systems that are susceptible to noise, power glitches,
or electrostatic discharge. It can also be used to prevent a software deadlock. If during the execution of
the user’s code, there is a deadlock, the Watchdog Timer will time out and an internal reset will occur.
Only module 4 can be programmed as a Watchdog Timer (but still can be programmed to other modes
if the Watchdog Timer is not used).
To use the Watchdog Timer, the user pre-loads a 16-bit value in the compare register. Just like the
other compare modes, this 16-bit value is compared to the PCA timer value. If a match is allowed to
occur, an internal reset will be generated. This will not cause the RST pin to be driven high.
In order to hold off the reset, the user has three options:
1.
periodically change the compare value so it will never match the PCA timer,
2.
periodically change the PCA timer value so it will never match the compare values, or
3.
disable the watchdog timer by clearing the WDTE bit before a match occurs and then reenable it.
The first two options are more reliable because the Watchdog Timer is never disabled as in option #3.
If the program counter ever goes astray, a match will eventually occur and cause an internal reset. The
second option is also not recommended if other PCA modules are being used. Remember, the PCA
timer is the time base for all modules; changing the time base for other modules would not be a good
idea. Thus, in most application the first solution is the best option.
Use the code below to initialize the Watchdog Timer. Module 4 can be configured in either compare
mode, and the WDTE bit in CMOD must also be set. The user’s software then must periodically
change (CCAP4H, CCAP4L) to keep a match from occurring with the PCA timer (CH, CL). This code is
given in the Watchdog routine below.
;==============================================
Init_Watchdog:
MOVCCAPM4, #4CH; Module 4 in compare mode
MOVCCAP4L, #0FFH; Write to low byte first
MOVCCAP4H, #0FFH; Before PCA timer counts up
; to FFFF Hex, these compare
; values must be changed.
ORLCMOD, #40H; Set the WDTE bit to enable the
; watchdog timer without
; changing the other bits in
; CMOD
;==============================================
;Main program goes here, but call WATCHDOG periodically.
;==============================================
WATCHDOG:
©2013 Silicon Storage Technology, Inc.
DS25093B
59
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
CLR EA; Hold off interrupts
MOVCCAP4L, #00; Next compare value is within
MOVCCAP4H, CH; 65,535 counts of the
; current PCA
SETBEA; timer value
RET
;==============================================
This routine should not be part of an interrupt service routine. If the program counter goes astray and
gets stuck in an infinite loop, interrupts will still be serviced and the watchdog will keep getting reset.
Thus, the purpose of the watchdog would be defeated. Instead, call this subroutine from the main program of the PCA timer.
CIDL
Write to
CCAP4L
CPS1
CPS0
ECF
CMOD
Reset
Write to
CCAP4H
1
WDTE
CCAP4H
CCAP4L
Module 4
0
Enable
Match
16-bit Comparator
CH
Reset
CL
PCA Timer/Counter
ECOMn CAPPn CAPNn
MATn
TOGn
0
1
X
0
PWMn ECCFn
0
CCAPM4
X
1273 F25.0
Figure 29:PCA Watchdog Timer (Module 4 only)
©2013 Silicon Storage Technology, Inc.
DS25093B
60
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Security Lock
The security lock protects against software piracy and prevents the contents of the flash from being
read by unauthorized parties. It also protects against code corruption resulting from accidental erasing
and programming to the internal flash memory. There are two different types of security locks in the
device security lock system: hard lock and SoftLock.
Hard Lock
When hard lock is activated, MOVC or IAP instructions executed from an unlocked or soft locked program address space, are disabled from reading code bytes in hard locked memory blocks (See Table
26). Hard lock can either lock both flash memory blocks or just lock the 8 KByte flash memory block
(Block 1). All external host and IAP commands except for Chip-Erase are ignored for memory blocks
that are hard locked.
SoftLock
SoftLock allows flash contents to be altered under a secure environment. This lock option allows the
user to update program code in the soft locked memory block through in-application programming
mode under a predetermined secure environment. For example, if Block 1 (8K) memory block is locked
(hard locked or soft locked), and Block 0 memory block is soft locked, code residing in Block 1 can program Block 0. The following IAP mode commands issued through the command mailbox register,
SFCM, executed from a Locked (hard locked or soft locked) block, can be operated on a soft locked
block: Block-Erase, Sector-Erase, Byte-Program and Byte-Verify.
In external host mode, SoftLock behaves the same as a hard lock.
Security Lock Status
The three bits that indicate the device security lock status are located in SFST[7:5]. As shown in Figure
30 and Table 25, the three security lock bits control the lock status of the primary and secondary blocks
of memory. There are four distinct levels of security lock status. In the first level, none of the security
lock bits are programmed and both blocks are unlocked. In the second level, although both blocks are
now locked and cannot be programmed, they are available for read operation via Byte-Verify. In the
third level, three different options are available: Block 1 hard lock / Block 0 SoftLock, SoftLock on both
blocks, and hard lock on both blocks. Locking both blocks is the same as Level 2, Block 1 except read
operation isn’t available. The fourth level of security is the most secure level. It doesn’t allow read/program of internal memory or boot from external memory. For details on how to program the security lock
bits refer to the external host mode and in-application programming sections.
©2013 Silicon Storage Technology, Inc.
DS25093B
61
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
UUU/NN
Level 1
PUU/SS
Level 2
UPU/SS
UUP/LS
Level 3
UPP/LL
PPU/LS
PUP/LL
UPP/LL
Level 4
PPP/LL
1273 F26.0
Figure 30:Security Lock Levels
Note:
P = Programmed (Bit logic state = 0), U = Unprogrammed (Bit logic state = 1), N = Not Locked, L = Hard locked, S = Soft
locked
Table 25: Security Lock Options
Security Lock Bits1,2
Security Status of:
Level
SFST[7:5]
SB1
SB21
1
000
U
U
U
Unlock
Unlock
No Security Features are
Enabled.
2
100
P
U
U
SoftLock
SoftLock
MOVC instructions executed from
external program memory are
disabled from fetching code bytes
from internal memory, EA# is
sampled and latched on Reset,
and further programming of the
flash is disabled.
3
011
101
U
P
P
U
P
P
Hard Lock
Hard Lock
Level 2 plus Verify disabled, both
blocks locked.
010
U
P
U
SoftLock
SoftLock
Level 2 plus Verify disabled. Code
in Block 1 may program Block 0
and vice versa.
110
001
P
U
P
U
U
P
Hard Lock
SoftLock
Level 2 plus Verify disabled. Code
in Block 1 may program Block 0.
111
P
P
P
Hard Lock
Hard Lock
Same as Level 3 hard lock/hard
lock, but MCU will start code execution from the internal memory
regardless of EA#.
4
SB31
Block 1
Block 0
Security Type
T0-0.0 25093
1. P = Programmed (Bit logic state = 0), U = Unprogrammed (Bit logic state = 1).
2. SFST[7:5] = Security Lock Status Bits (SB1_i, SB2_i, SB3_i)
©2013 Silicon Storage Technology, Inc.
DS25093B
62
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Read Operation Under Lock Condition
The status of security bits SB1, SB2, and SB3 can be read when the read command is disabled by
security lock. There are three ways to read the status.
1.
External host mode: Read-back = 00H (locked)
2.
IAP command: Read-back = previous SFDT data
3.
MOVC: Read-back = FFH (blank)
Table 26: Security Lock Access Table
Level
SFST[7:5]
Source
Address1
Block 0/1
4
111b
(hard lock on both blocks)
External
Block 0/1
011b/101b
(hard lock on both blocks)
External
Block 0
001b/110b
(Block 0 = SoftLock,
Block 1 = hard lock)
Block 1
3
External
Block 0
010b
(SoftLock on both blocks)
Block 1
External
Block 0
2
100b
(SoftLock on both blocks)
Block 1
External
©2013 Silicon Storage Technology, Inc.
Target
Address2
Byte-Verify Allowed
External
Host3
IAP
MOVC Allowed
516RDx
Block 0/1
N
N
Y
External
N/A
N/A
N
Block 0/1
N
N
N
External
N/A
N/A
N
Block 0/1
N
N
Y
External
N/A
N/A
N
Block 0/1
N
N
N
External
N/A
N/A
Y
Block 0
N
N
Y
Block 1
N
N
N
External
N/A
N/A
N
Block 0
N
Y
Y
Block 1
N
N
Y
External
N/A
N/A
N
Block 0/1
N
N
N
External
N/A
N/A
Y
Block 0
N
N
Y
Block 1
N
Y
Y
External
N/A
N/A
N
Block 0
N
Y
Y
Block 1
N
N
Y
External
N/A
N/A
N
Block 0/1
N
N
N
External
N/A
N/A
Y
Block 0
Y
N
Y
Block 1
Y
Y
Y
External
N/A
N/A
N
Block 0
Y
Y
Y
Block 1
Y
N
Y
External
N/A
N/A
N
Block 0/1
Y
N
N
External
N/A
N/A
Y
DS25093B
63
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Table 26: Security Lock Access Table
Level
SFST[7:5]
Source
Address1
Target
Address2
Byte-Verify Allowed
External
Block 0
Block 0
1
000b
(unlock)
Block 1
External
Host3
Y
MOVC Allowed
IAP
516RDx
N
Y
Block 1
Y
Y
Y
External
N/A
N/A
N
Block 0
Y
Y
Y
Block 1
Y
N
Y
External
N/A
N/A
N
Block 0/1
Y
Y
N
External
N/A
N/A
Y
T0-0.0 25093
1. Location of MOVC or IAP instruction
2. Target address is the location of the byte being read
3. External host Byte-Verify access does not depend on a source address.
©2013 Silicon Storage Technology, Inc.
DS25093B
64
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Reset
A system reset initializes the MCU and begins program execution at program memory location 0000H.
The reset input for the device is the RST pin. In order to reset the device, a logic level high must be
applied to the RST pin for at least two machine cycles (24 clocks), after the oscillator becomes stable.
ALE, PSEN# are weakly pulled high during reset. During reset, ALE and PSEN# output a high level in
order to perform a proper reset. This level must not be affected by external element. A system reset will
not affect the 1 KByte of on-chip RAM while the device is running, however, the contents of the on-chip
RAM during power up are indeterminate. Following reset, all Special Function Registers (SFR) return
to their reset values outlined in Tables 6 to 10.
Power-on Reset
At initial power up, the port pins will be in a random state until the oscillator has started and the internal
reset algorithm has weakly pulled all pins high. Powering up the device without a valid reset could
cause the MCU to start executing instructions from an indeterminate location. Such undefined
states may inadvertently corrupt the code in the flash.
When power is applied to the device, the RST pin must be held high long enough for the oscillator to start up (usually several milliseconds for a low frequency crystal), in addition to two machine cycles for a valid power-on reset. An
example of a method to extend the RST signal is to implement a RC circuit by connecting the RST pin to VDD
through a 10 µF capacitor and to VSS through an 8.2KΩ resistor as shown in Figure 31. Note that if an RC circuit is
being used, provisions should be made to ensure the VDD rise time does not exceed 1 millisecond and the oscillator
start-up time does not exceed 10 milliseconds.
For a low frequency oscillator with slow start-up time the reset signal must be extended in order to
account for the slow start-up time. This method maintains the necessary relationship between VDD and
RST to avoid programming at an indeterminate location, which may cause corruption in the code of the
flash. The power-on detection is designed to work as power up initially, before the voltage reaches the
brown-out detection level. The POF flag in the PCON register is set to indicate an initial power up condition. The POF flag will remain active until cleared by software. Please see Section , “Power Control
Register (PCON)” on page 31 for detailed information.
For more information on system level design techniques, please review the FlashFlex MCU: Oscillator Circuit Design Considerations application note.
VDD
+
10µF
VDD
RST
8.2K
SST89E/V516RDx
C2
XTAL2
XTAL1
C1
1273 F27.0
Figure 31:Power-on Reset Circuit
©2013 Silicon Storage Technology, Inc.
DS25093B
65
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Software Reset
The software reset is executed by changing SFCF[1] (SWR) from “0” to “1”. A software reset will reset
the program counter to address 0000H. All SFR registers will be set to their reset values, except
SFCF[1] (SWR), WDTC[2] (WDTS), and RAM data will not be altered.
Brown-out Detection Reset
The device includes a brown-out detection circuit to protect the system from severed supplied voltage
VDD fluctuations. SST89E516RDx internal brown-out detection threshold is 3.85V, SST89V516RDx
brown-out detection threshold is 2.35V. For brown-out voltage parameters, please refer to Table 36.
When VDD drops below this voltage threshold, the brown-out detector triggers the circuit to generate a
brown-out interrupt but the CPU still runs until the supplied voltage returns to the brown-out detection
voltage VBOD. The default operation for a brown-out detection is to cause a processor reset.
VDD must stay below VBOD at least four oscillator clock periods before the brown-out detection circuit
will respond.
Brown-out interrupt can be enabled by setting the EBO bit in IEA register (address E8H, bit 3). If EBO
bit is set and a brown-out condition occurs, a brown-out interrupt will be generated to execute the program at location 004BH. It is required that the EBO bit be cleared by software after the brown-out interrupt is serviced. Clearing EBO bit when the brown-out condition is active will properly reset the device.
If brown-out interrupt is not enabled, a brown-out condition will reset the program to resume execution
at location 0000H.
©2013 Silicon Storage Technology, Inc.
DS25093B
66
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Interrupts
Interrupt Priority and Polling Sequence
The device supports eight interrupt sources under a four level priority scheme. Table 27 summarizes
the polling sequence of the supported interrupts. Note that the SPI serial interface and the UART share
the same interrupt vector. (See Figure 32)
Table 27: Interrupt Polling Sequence
Description
Ext. Int0
Brown-out
T0
Interrupt
Flag
Vector
Address
Interrupt
Enable
Interrupt
Priority
Service
Priority
Wake-Up
Power-down
IE0
0003H
EX0
PX0/H
1(highest)
yes
-
004BH
EBO
PBO/H
2
no
TF0
000BH
ET0
PT0/H
3
no
Ext. Int1
IE1
0013H
EX1
PX1/H
4
yes
T1
TF1
001BH
ET1
PT1/H
5
no
PCA
Ext. Int. 2
CF/CCFn
0033H
EC
PPCH
6
no
IE2
003BH
EX2
PX2/H
7
no
Ext. Int. 3
IE3
0043H
EX3
PX3/H
8
no
UART/SPI
TI/RI/SPIF
0023H
ES
PS/H
9
no
T2
TF2, EXF2
002BH
ET2
PT2/H
10
no
T0-0.0 25093
©2013 Silicon Storage Technology, Inc.
DS25093B
67
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
IE & IEA
REGISTERS
IP/IPH/IPA/IPAH
REGISTERS
HIGHEST PRIORITY
INTERRUPT
0
INT0#
IT0
IE0
1
INTERRUPT
POLLING
SEQUENCE
BOF
TF0
0
INT1#
IT1
IE1
IT2
IE2
IT3
IE3
1
TF1
ECF
CF
CCFn
ECCFn
0
INT2#
1
0
INT3#
1
RI
TI
SPIF
SPIE
TF2
EXF2
GLOBAL
DISABLE
INDIVIDUAL
ENABLES
LOWEST PRIORITY
INTERRUPT
1273 F28.0
Figure 32:Interrupt Structure
©2013 Silicon Storage Technology, Inc.
DS25093B
68
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Power-Saving Modes
The device provides two power saving modes of operation for applications where power consumption
is critical. The two modes are idle and power-down, see Table 28.
Idle Mode
Idle mode is entered setting the IDL bit in the PCON register. In idle mode, the program counter (PC) is
stopped. The system clock continues to run and all interrupts and peripherals remain active. The onchip RAM and the special function registers hold their data during this mode.
The device exits idle mode through either a system interrupt or a hardware reset. Exiting idle mode via
system interrupt, the start of the interrupt clears the IDL bit and exits idle mode. After exit the Interrupt
Service Routine, the interrupted program resumes execution beginning at the instruction immediately
following the instruction which invoked the idle mode. A hardware reset starts the device similar to a
power-on reset.
Power-down Mode
The power-down mode is entered by setting the PD bit in the PCON register. In the power-down mode,
the clock is stopped and external interrupts are active for level sensitive interrupts only. SRAM contents
are retained during power-down, the minimum VDD level is 2.0V.
The device exits power-down mode through either an enabled external level sensitive interrupt or a
hardware reset. The start of the interrupt clears the PD bit and exits power-down. Holding the external
interrupt pin low restarts the oscillator, the signal must hold low at least 1024 clock cycles before bringing back high to complete the exit. Upon interrupt signal being restored to logic VIH, the first instruction
of the interrupt service routine will execute. A hardware reset starts the device similar to power-on
reset.
To exit properly out of power-down, the reset or external interrupt should not be executed before the
VDD line is restored to its normal operating voltage. Be sure to hold VDD voltage long enough at its normal operating level for the oscillator to restart and stabilize (normally less than 10 ms).
©2013 Silicon Storage Technology, Inc.
DS25093B
69
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Table 28: Power Saving Modes
Mode
Initiated by
State of MCU
Exited by
Idle Mode
Software
(Set IDL bit in PCON)
MOV PCON, #01H;
CLK is running.
Interrupts, serial port and
timers/counters are active.
Program Counter is
stopped. ALE and PSEN#
signals at a HIGH level
during Idle. All registers
remain unchanged.
Enabled interrupt or hardware
reset. Start of interrupt clears IDL
bit and exits idle mode, after the
ISR RETI instruction, program
resumes execution beginning at
the instruction following the one
that invoked idle mode. A user
could consider placing two or three
NOP instructions after the instruction that invokes idle mode to eliminate any problems. A hardware
reset restarts the device similar to
a power-on reset.
Power-down
Mode
Software
(Set PD bit in PCON)
MOV PCON, #02H;
CLK is stopped. On-chip
SRAM and SFR data is
maintained. ALE and
PSEN# signals at a LOW
level during power -down.
External Interrupts are
only active for level sensitive interrupts, if enabled.
Enabled external level sensitive
interrupt or hardware reset. Start
of interrupt clears PD bit and exits
power-down mode, after the ISR
RETI instruction program resumes
execution beginning at the instruction following the one that invoked
power-down mode. A user could
consider placing two or three NOP
instructions after the instruction
that invokes power-down mode to
eliminate any problems. A hardware reset restarts the device similar to a power-on reset.
T0-0.0 25093
©2013 Silicon Storage Technology, Inc.
DS25093B
70
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
System Clock and Clock Options
Clock Input Options and Recommended Capacitor Values for Oscillator
Shown in Figure 33 are the input and output of an internal inverting amplifier (XTAL1, XTAL2), which
can be configured for use as an on-chip oscillator.
When driving the device from an external clock source, XTAL2 should be left disconnected and XTAL1
should be driven.
At start-up, the external oscillator may encounter a higher capacitive load at XTAL1 due to interaction
between the amplifier and its feedback capacitance. However, the capacitance will not exceed 15 pF
once the external signal meets the VIL and VIH specifications.
Crystal manufacturer, supply voltage, and other factors may cause circuit performance to differ from
one application to another. C1 and C2 should be adjusted appropriately for each design. Table 29,
shows the typical values for C1 and C2 vs. crystal type for various frequencies
Table 29: Recommended Values for C1 and C2 by Crystal Type
Crystal
C1 = C2
Quartz
20-30pF
Ceramic
40-50pF
T0-0.0 25093
More specific information about on-chip oscillator design can be found in the FlashFlex Oscillator
Circuit Design Considerations application note.
Clock Doubling Option
By default, the device runs at 12 clocks per machine cycle (x1 mode). The device has a clock doubling
option to speed up to 6 clocks per machine cycle. Please refer to Table 30 for detail.
Clock double mode can be enabled either via the external host mode or the IAP mode. Please refer to
Table 14 for the IAP mode enabling commands (When set, the EDC# bit in SFST register will indicate
6 clock mode.).
The clock double mode is only for doubling the internal system clock and the internal flash
memory, i.e. EA#=1. To access the external memory and the peripheral devices, careful consideration
must be taken. Also note that the crystal output (XTAL2) will not be doubled.
©2013 Silicon Storage Technology, Inc.
DS25093B
71
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
XTAL2
NC
C2
External
Oscillator
Signal
C1
XTAL1
XTAL2
XTAL1
VSS
VSS
External Clock Drive
Using the On-Chip Oscillator
1273 F29.0
Figure 33:Oscillator Characteristics
Table 30: Clock Doubling Features
Device
Standard Mode (x1)
Clock Double Mode (x2)
Clocks per
Machine
Cycle
Max. External Clock
Frequency
(MHz)
Clocks per
Machine
Cycle
Max. External Clock
Frequency
(MHz)
SST89E516RDx
12
40
6
20
SST89V516RDx
12
33
6
16
T0-0.0 25093
©2013 Silicon Storage Technology, Inc.
DS25093B
72
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Electrical Specification
Absolute Maximum Stress Ratings (Applied conditions greater than those listed under “Absolute
Maximum Stress Ratings” may cause permanent damage to the device. This is a stress rating only and
functional operation of the device at these conditions or conditions greater than those defined in the
operational sections of this data sheet is not implied. Exposure to absolute maximum stress rating conditions may affect device reliability.)
Ambient Temperature Under Bias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55°C to +125°C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -65°C to +150°C
Voltage on EA# Pin to VSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to +14.0V
D.C. Voltage on Any Pin to Ground Potential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to VDD+0.5V
Transient Voltage (<20ns) on Any Other Pin to VSS . . . . . . . . . . . . . . . . . . . . . . . . . -1.0V to VDD+1.0V
Maximum IOL per I/O Pins P1.5, P1.6, P1.7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20mA
Maximum IOL per I/O for All Other Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15mA
Package Power Dissipation Capability (TA = 25°C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5W
Through Hole Lead Soldering Temperature (10 Seconds) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .300°C
Surface Mount Solder Reflow Temperature1 . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C for 10 seconds
Output Short Circuit Current2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA
1. Excluding certain with-Pb 32-PLCC units, all packages are 260°C capable in both non-Pb and with-Pb solder versions.
Certain with-Pb 32-PLCC package types are capable of 240°C for 10 seconds; please consult the factory for the latest
information.
2. Outputs shorted for no more than one second. No more than one output shorted at a time.
(Based on package heat transfer limitations, not device power consumption.
Note: This specification contains preliminary information on new products in production.
The specifications are subject to change without notice.
Table 31: Operating Range
Symbol
Description
TA
Ambient Temperature Under Bias
VDD
fOSC
Min.
Max
Unit
Standard
0
+70
Industrial
-40
+85
°C
°C
SST89E516RDx
4.5
5.5
V
SST89V516RDx
2.7
3.6
V
SST89E516RDx
0
40
MHz
SST89V516RDx
0
33
MHz
SST89E516RDx
.25
40
MHz
SST89V516RDx
.25
33
MHz
Supply Voltage
Oscillator Frequency
Oscillator Frequency for IAP
T0-0.0 25093
©2013 Silicon Storage Technology, Inc.
DS25093B
73
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Table 32: Reliability Characteristics
Symbol
Parameter
Minimum Specification
Units
Test Method
NEND1
Endurance
10,000
Cycles
JEDEC Standard A117
100
Years
100 + IDD
mA
TDR
1
Data Retention
ILTH1
Latch Up
JEDEC Standard A103
JEDEC Standard 78
T0-0.0 25093
1. This parameter is measured only for initial qualification and after a design or process change that could affect this
parameter.
Table 33: AC Conditions of Test1
Input Rise/Fall Time
Output Load
10 ns
CL = 100 pF
T33.1 25093
1. See Figures 41 and 43
Table 34: Recommended System Power-up Timings
Symbol
Parameter
Minimum
Units
TPU-READ1
Power-up to Read Operation
100
µs
Power-up to Write Operation
100
µs
TPU-WRITE
1
T0-0.0 25093
1. This parameter is measured only for initial qualification and after a design or process change that could affect this
parameter
Table 35: Pin Impedance (VDD=3.3V, TA=25°C, f=1 Mhz, other pins open)
Parameter
Description
CI/O1
CIN1
LPIN2
Test Condition
Maximum
I/O Pin Capacitance
VI/O = 0V
15 pF
Input Capacitance
VIN = 0V
12 pF
Pin Inductance
20 nH
T0-0.0 25093
1. This parameter is measured only for initial qualification and after a design or process change that could affect this
parameter.
2. Refer to PCI spec.
©2013 Silicon Storage Technology, Inc.
DS25093B
74
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
DC Electrical Characteristics
Table 36: DC Electrical Characteristics for SST89E516RDx
TA = -40°C to +85°C; VDD = 4.5-5.5V; VSS = 0V
Symbol Parameter
Test Conditions
Min
Max
Units
VIL
Input Low Voltage
4.5 < VDD < 5.5
-0.5
0.2VDD 0.1
V
VIH
Input High Voltage
4.5 < VDD < 5.5
0.2VDD +
0.9
VDD + 0.5
V
VIH1
Input High Voltage (XTAL1, RST)
4.5 < VDD < 5.5
0.7VDD
VDD + 0.5
V
VOL
Output Low Voltage (Ports 1.5, 1.6, 1.7)
1.0
V
IOL = 100µA2
0.3
V
1.6mA2
0.45
V
IOL = 3.5mA2
1.0
V
IOL = 200µA2
0.3
V
3.2mA2
0.45
V
VDD = 4.5V
IOL = 16mA
VOL
Output Low Voltage (Ports 1, 2,
3)1
VDD = 4.5V
IOL =
VOL1
Output Low Voltage (Port 0, ALE,
PSEN#)1,3
VDD = 4.5V
IOL =
VOH
VOH1
Output High Voltage (Ports 1, 2, 3, ALE,
PSEN#)4
Output High Voltage (Port 0 in External
Bus Mode)4
VBOD
Brown-out Detection Voltage
IIL
Logical 0 Input Current (Ports 1, 2, 3)
ITL
Logical 1-to-0 Transition Current (Ports 1,
2, 3)5
ILI
Input Leakage Current (Port 0)
RRST
RST Pull-down Resistor
CIO
Pin Capacitance6
IDD
Power Supply Current
VDD = 4.5V
IOH = -10µA
VDD - 0.3
V
IOH = -30µA
VDD - 0.7
V
IOH = -60µA
VDD - 1.5
V
IOH = -200µA
VDD - 0.3
V
IOH = -3.2mA
VDD - 0.7
V
VDD = 4.5V
4.15
V
VIN = 0.4V
3.85
-75
µA
VIN = 2V
-650
µA
0.45 < VIN < VDD-0.3
40
@ 1 MHz, 25°C
±10
µA
225
KΩ
15
pF
88
mA
50
mA
42
mA
IAP Mode
@ 40 MHz
Active Mode
@ 40 MHz
Idle Mode
@ 40 MHz
Power-down Mode (min. VDD = 2V)
TA = 0°C to +70°C
80
µA
TA = -40°C to +85°C
90
µA
T0-0.1 25093
©2013 Silicon Storage Technology, Inc.
DS25093B
75
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
1. Under steady state (non-transient) conditions, IOL must be externally limited as follows:
Maximum IOL per port pin:
15mA
26mA
Maximum IOL per 8-bit port:
Maximum IOL total for all outputs:71mA
If IOL exceeds the test condition, VOL may exceed the related specification.
Pins are not guaranteed to sink current greater than the listed test conditions.
2. Capacitive loading on Ports 0 and 2 may cause spurious noise to be superimposed on the VOLs of ALE and Ports 1 & 3.
The noise due to external bus capacitance discharging into the Port 0 & 2 pins when the pins make 1-to-0 transitions
during bus operations. In the worst cases (capacitive loading > 100pF), the noise pulse on the ALE pin may exceed
0.8V. In such cases, it may be desirable to qualify ALE with a Schmitt Trigger, or use an address latch with a Schmitt
Trigger STROBE input.
3. Load capacitance for Port 0, ALE & PSEN#= 100pF, load capacitance for all other outputs = 80pF.
4. Capacitive loading on Ports 0 and 2 may cause the VOH on ALE and PSEN# to momentarily fall below the VDD - 0.7
specification when the address bits are stabilizing.
5. Pins of Ports 1, 2, and 3 source a transition current when they are being externally driven from 1 to 0. The transition current reaches its maximum value when VIN is approximately 2V.
6. Pin capacitance is characterized but not tested. EA# is 25pF (max).
©2013 Silicon Storage Technology, Inc.
DS25093B
76
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Table 37: DC Electrical Characteristics for SST89V516RDx
TA = -40°C to +85°C; VDD = 2.7-3.6V; VSS = 0V
Symbo
l
Parameter
Test Conditions
Min
Max
Unit
s
VIL
Input Low Voltage
2.7 < VDD < 3.6
-0.5
0.7
V
VIH
Input High Voltage
2.7 < VDD < 3.6
0.2VDD +
0.9
VDD +
0.5
V
VIH1
Input High Voltage (XTAL1, RST)
2.7 < VDD < 3.6
0.7VDD
VDD +
0.5
V
VOL
Output Low Voltage (Ports 1.5, 1.6, 1.7)
1.0
V
VOL
Output Low Voltage (Ports 1, 2, 3)1
VDD = 2.7V
IOL = 16mA
VOL1
VOH
VOH1
Output Low Voltage (Port 0, ALE, PSEN#)1,3
Output High Voltage (Ports 1, 2, 3, ALE,
PSEN#)4
Output High Voltage (Port 0 in External Bus
Mode)4
VBOD
Brown-out Detection Voltage
IIL
Logical 0 Input Current (Ports 1, 2, 3)
Logical 1-to-0 Transition Current (Ports 1, 2, 3)5
ILI
Input Leakage Current (Port 0)
RST Pull-down Resistor
CIO
Pin Capacitance6
IDD
Power Supply Current
IOL = 100µA2
0.3
V
IOL = 1.6mA2
0.45
V
IOL = 3.5mA2
1.0
V
VDD = 2.7V
IOL = 200µA2
0.3
V
IOL = 3.2mA2
0.45
V
VDD = 2.7V
IOH = -10µA
VDD - 0.3
V
IOH = -30µA
VDD - 0.7
V
IOH = -60µA
VDD - 1.5
V
IOH = -200µA
VDD - 0.3
V
IOH = -3.2mA
VDD - 0.7
VDD = 2.7V
2.35
ITL
RRST
VDD = 2.7V
V
2.55
V
VIN = 0.4V
-75
µA
VIN = 2V
-650
µA
0.45 < VIN < VDD-0.3
±10
µA
225
KΩ
15
pF
47
mA
30
mA
21
mA
TA = 0°C to +70°C
45
µA
TA = -40°C to +85°C
55
@ 1 MHz, 25°C
IAP Mode
@ 33 MHz
Active Mode
@ 33 MHz
Idle Mode
@ 33 MHz
Power-down Mode (min. VDD = 2V)
µA
T0-0.1 25093
©2013 Silicon Storage Technology, Inc.
DS25093B
77
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
1. Under steady state (non-transient) conditions, IOL must be externally limited as follows:
Maximum IOL per port pin:
15mA
26mA
Maximum IOL per 8-bit port:
Maximum IOL total for all outputs: 71mA
If IOL exceeds the test condition, VOL may exceed the related specification. Pins are not guaranteed to sink current
greater than the listed test conditions.
2. Capacitive loading on Ports 0 and 2 may cause spurious noise to be superimposed on the VOLs of ALE and Ports 1 & 3.
The noise due to external bus capacitance discharging into the Port 0 & 2 pins when the pins make 1-to-0 transitions
during bus operations. In the worst cases (capacitive loading > 100pF), the noise pulse on the ALE pin may exceed
0.8V. In such cases, it may be desirable to qualify ALE with a Schmitt Trigger, or use an address latch with a Schmitt
Trigger STROBE input.
3. Load capacitance for Port 0, ALE & PSEN#= 100pF, load capacitance for all other outputs = 80pF.
4. Capacitive loading on Ports 0 & 2 may cause the VOH on ALE and PSEN# to momentarily fall below the VDD - 0.7 specification when the address bits are stabilizing.
5. Pins of Ports 1, 2, and 3 source a transition current when they are being externally driven from 1 to 0. The transition current reaches its maximum value when VIN is approximately 2V.
6. Pin capacitance is characterized but not tested. EA# is 25pF (max).
©2013 Silicon Storage Technology, Inc.
DS25093B
78
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
30
Maximum Active IDD
25
Maximum Idle IDD
IDD (mA)
20
15
1273 F30.0
10
Typical Active IDD
5
Typical Idle IDD
0
5
10
15
20
25
Internal Clock Frequency (MHz)
30
35
Figure 34:IDD vs. Frequency for 3V SST89V516RDx
50
Maximum Active IDD
Maximum Idle IDD
30
20
1273 F31.0
IDD (mA)
40
Typical Active IDD
10
Typical Idle IDD
0
5
10
15
20
25
30
35
40
Internal Clock Frequency (MHz)
Figure 35:IDD vs. Frequency for 5V SST89E516RDx
©2013 Silicon Storage Technology, Inc.
DS25093B
79
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
AC Electrical Characteristics
AC Characteristics:
(Over Operating Conditions: Load Capacitance for Port 0, ALE#, and PSEN# = 100pF;
Load Capacitance for All Other Outputs = 80pF)
Table 38: AC Electrical Characteristics (1 of 2)
TA = -40°C to +85°C, VDD = 2.7-3.6V@33MHz, 4.5-5.5V@40MHz, VSS = 0V
Oscillator
33 MHz (x1
Mode)
16 MHz (x2
Mode)1
Symbol
Parameter
1/TCLCL
x1 Mode Oscillator Frequency
x2 Mode Oscillator Frequency
ALE Pulse Width
Address Valid to ALE Low
1/2TCLCL
TLHLL
TAVLL
40 MHz (x1
Mode)
20 MHz (x2
Mode)1
Min
Max
Min
Max
Min
Max
Units
0
33
0
40
0
40
MHz
0
16
0
20
0
20
MHz
46
35
5
10
TLLAX
Address Hold After ALE
Low
5
10
TLLIV
Variable
ALE Low to Valid Instr In
2TCLCL - 15
ns
TCLCL - 25 (3V)
ns
TCLCL - 15 (5V)
ns
TCLCL - 25 (3V)
ns
TCLCL - 15 (5V)
ns
56
55
TLLPL
ALE Low to PSEN# Low
5
10
TPLPH
PSEN# Pulse Width
TPLIV
PSEN# Low to Valid Instr
In
66
60
TPXIZ
ns
ns
3TCLCL - 25
(3V)
3TCLCL - 15
(5V)
ns
TPLAZ
PSEN# to Address valid
Address to Valid Instr In
TRLRH
PSEN# Low to Address
Float
RD# Pulse Width
TWLWH
Write Pulse Width (WE#)
TRLDV
RD# Low to Valid Data In
3TCLCL - 55 (3V)
ns
3TCLCL - 50 (5V)
ns
0
25
22
17
TCLCL - 15 (5V)
TCLCL - 8
72
10
5TCLCL - 80 (3V)
ns
65
5TCLCL - 60 (5V)
ns
10
10
ns
ns
6TCLCL - 40 (3V)
6TCLCL - 30 (5V)
ns
120
5TCLCL - 90 (3V)
DS25093B
80
ns
ns
6TCLCL - 40 (3V)
6TCLCL - 30 (5V)
142
©2013 Silicon Storage Technology, Inc.
ns
120
142
62
ns
TCLCL - 5 (3V)
10
TPXAV
TAVIV
ns
TCLCL - 15 (5V)
35
Input Instr Hold After
PSEN#
Input Instr Float After
PSEN#
ns
TCLCL - 25 (3V)
25
TPXIX
4TCLCL - 65 (3V)
4TCLCL - 45 (5V)
ns
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Table 38: AC Electrical Characteristics (Continued) (2 of 2)
TA = -40°C to +85°C, VDD = 2.7-3.6V@33MHz, 4.5-5.5V@40MHz, VSS = 0V
Oscillator
33 MHz (x1
Mode)
16 MHz (x2
Mode)1
Symbol
Parameter
Min
Max
40 MHz (x1
Mode)
20 MHz (x2
Mode)1
Min
Max
Variable
Min
75
TRHDX
TRHDZ
Data Hold After RD#
Data Float After RD#
TLLDV
ALE Low to Valid Data In
0
0
38
152
150
Address to Valid Data In
TLLWL
ALE Low to RD# or WR#
Low
Address to RD# or WR#
Low
66
Data Hold After WR#
3
183
150
TAVWL
116
60
90
46
5
TQVWH
Data Valid to WR# High
TQVWX
Data Valid to WR# High to
Low
Transition
TRLAZ
TWHLH
RD# Low to Address Float
142
RD# to WR# High to ALE
High
ns
2TCLCL - 25 (3V)
ns
2TCLCL - 12 (5V)
ns
8TCLCL - 90 (3V)
ns
8TCLCL - 50 (5V)
ns
9TCLCL - 90 (3V)
ns
3TCLCL - 25 (3V)
3TCLCL - 15 (5V)
9TCLCL - 75 (5V)
ns
3TCLCL + 25 (3V)
3TCLCL + 15 (5V)
ns
ns
4TCLCL - 75 (3V)
70
TWHQX
Units
0
36
TAVDV
Max
5TCLCL - 50 (5V)
10
4TCLCL - 30 (5V)
ns
TCLCL - 27 (3V)
ns
TCLCL - 20 (5V)
ns
7TCLCL - 70 (3V)
ns
125
7TCLCL - 50 (5V)
ns
5
TCLCL - 20
ns
0
5
ns
0
55
10
40
0
ns
TCLCL - 25 (3V)
TCLCL + 25 (3V)
ns
TCLCL - 15 (5V)
TCLCL + 15 (5V)
ns
T0-0.0 25093
1. Calculated values are for x1 Mode only
©2013 Silicon Storage Technology, Inc.
DS25093B
81
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Explanation of Symbols
Each timing symbol has 5 characters. The first character is always a ‘T’ (stands for time). The other
characters, depending on their positions, stand for the name of a signal or the logical status of that signal. The following is a list of all the characters and what they stand for.
A:
C:
D:
H:
I:
L:
P:
Address
Clock
Input data
Logic level HIGH
Instruction (program memory contents)
Logic level LOW or ALE
PSEN#
Q:
R:
T:
V:
W:
X:
Z:
Output data
RD# signal
Time
Valid
WR# signal
No longer a valid logic level
High Impedance (Float)
For example:
TAVLL = Time from Address Valid to ALE Low
TLLPL = Time from ALE Low to PSEN# Low
©2013 Silicon Storage Technology, Inc.
DS25093B
82
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
TLHLL
ALE
TAVLL
TLLIV
TLLPL
TPLPH
TPLIV
PSEN#
TPXAV
TPLAZ
TLLAX
PORT 0
TPXIZ
TPXIX
A0 - A7
A0 - A7
INSTR IN
TAVIV
PORT 2
A8 - A15
A8 - A15
1273 F32.0
Figure 36:External Program Memory Read Cycle
TLHLL
ALE
TWHLH
PSEN#
TLLDV
TRLRH
TLLWL
RD#
TLLAX
TAVLL
PORT 0
TRLAZ
A0-A7 FROM RI or DPL
TRLDV
TRHDZ
TRHDX
DATA IN
A0-A7 FROM PCL
INSTR IN
TAVWL
TAVDV
PORT 2
P2[7:0] or A8-A15 FROM DPH
A8-A15 FROM PCH
1273 F33.0
Figure 37:External Data Memory Read Cycle
©2013 Silicon Storage Technology, Inc.
DS25093B
83
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
TLHLL
ALE
TWHLH
PSEN#
TWLWH
TLLWL
WR#
TLLAX
TAVLL
TWHQX
TQVWX
TQVWH
PORT 0
A0-A7 FROM RI or DPL
DATA OUT
A0-A7 FROM PCL
INSTR IN
TAVWL
PORT 2
P2[7:0] or A8-A15 FROM DPH
A8-A15 FROM PCH
1273 F34.0
Figure 38:External Data Memory Write Cycle
Table 39: External Clock Drive
Oscillator
12MHz
Symbol
1/TCLCL
TCLCL
TCHCX
TCLCX
TCLCH
TCHCL
Parameter
Oscillator Frequency
Min
Max
83
40MHz
Min
Max
25
8.75
8.75
High Time
Low Time
Rise Time
Fall Time
Variable
20
20
Min
0
Max
40
0.35TCLCL
0.35TCLCL
0.65TCLCL
0.65TCLCL
10
10
Units
MHz
ns
ns
ns
ns
ns
T0-0.0 25093
VDD - 0.5
0.45 V
0.7VDD
TCHCX
0.2 VDD - 0.1
TCHCL
TCLCX
TCLCH
TCLCL
1273 F35.0
Figure 39:External Clock Drive Waveform
©2013 Silicon Storage Technology, Inc.
DS25093B
84
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Table 40: Serial Port Timing
Oscillator
12MHz
Symbol
Parameter
Min Max
40MHz
Min
Variable
Max
Min
Max
Units
TXLXL
Serial Port Clock Cycle Time
1.0
0.3
12TCLCL
µs
TQVXH
Output Data Setup to Clock Rising
Edge
700
117
10TCLCL - 133
ns
TXHQX
Output Data Hold After Clock Rising Edge
50
TXHDX
Input Data Hold After Clock Rising
Edge
0
TXHDV
Clock Rising Edge to Input Data
Valid
2TCLCL - 117
ns
0
2TCLCL - 50
ns
0
0
ns
700
117
10TCLCL - 133
ns
T0-0.0 25093
INSTRUCTION
0
1
2
3
4
5
6
7
8
ALE
TXLXL
CLOCK
TXHQX
TQVXH
OUTPUT DATA
0
WRITE TO SBUF
1
2
TXHDV
INPUT DATA
VALID
3
4
5
6
7
TXHDX
VALID
SET TI
VALID
VALID
VALID
VALID
VALID
VALID
SET R I
CLEAR RI
1273 F36.0
Figure 40:Shift Register Mode Timing Waveforms
VIHT
VHT
VLT
VILT
1273 F37.0
AC Inputs during testing are driven at VIHT (VDD -0.5V) for Logic "1" and
VILT (0.45V) for a Logic "0". Measurement reference points for inputs and
outputs are at VHT (0.2VDD + 0.9) and VLT (0.2VDD - 0.1)
Note: VHT- VHIGH Test
VLT- VLOW Test
VIHT-VINPUT HIGH Test
VILT- VINPUT LOW Test
Figure 41:AC Testing Input/Output Test Waveform
©2013 Silicon Storage Technology, Inc.
DS25093B
85
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
VLOAD +0.1V
VOH -0.1V
Timing Reference
Points
VLOAD
VOL +0.1V
VLOAD -0.1V
1273 F38.0
For timing purposes, a port pin is no longer floating when a 100 mV
change from load voltage occurs, and begins to float when a 100 mV
change from the loaded VOH/VOL level occurs. IOL/IOH = ± 20mA.
Figure 42:Float Waveform
TO TESTER
TO DUT
CL
1273 F39.0
Figure 43:A Test Load Example
VDD
VDD
IDD
VDD
P0
VDD
RST
EA#
SST89x516RDx
CLOCK
SIGNAL
XTAL2
XTAL1
VSS
(NC)
1273 F40.0
All other pins disconnected
Figure 44:IDD Test Condition, Active Mode
©2013 Silicon Storage Technology, Inc.
DS25093B
86
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
VDD
VDD
IDD
VDD
P0
RST
EA#
SST89x516RDx
CLOCK
SIGNAL
(NC)
XTAL2
XTAL1
VSS
1273 F41.0
All other pins disconnected
Figure 45:IDD Test Condition, Idle Mode
VDD
VDD
IDD
VDD
P0
RST
EA#
SST89x5xxRDx
(NC)
XTAL2
XTAL1
VSS
1273 F42.0
All other pins disconnected
Figure 46:IDD Test Condition, Power-down Mode
Table 41: Flash Memory Programming/Verification Parameters1
Parameter2
Max
Chip-Erase Time
150
ms
Block-Erase Time
100
ms
Units
Sector-Erase Time
30
ms
Byte-Program Time3
50
µs
Select-Block Program Time
500
ns
Re-map or Security bit Program Time
80
µs
T0-0.1 25093
1. For IAP operations, the program execution overhead must be added to the above timing parameters.
2. Program and Erase times will scale inversely proportional to programming clock frequency.
3. Each byte must be erased before programming.
©2013 Silicon Storage Technology, Inc.
DS25093B
87
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Product Ordering Information
SST
89
E
XX XX
516RD2
-
33
-
C
-
TQJE
XXXXXX
-
XX -
X
-
XXXX
Environmental Attribute
E1 = non-Pb
F1 = non-Pb / non-Sn contact finish
Package Modifier
I = 40 pins
J = 44 pins
Package Type
P = PDIP
N = PLCC
Q = WQFN
TQ = TQFP
Operation Temperature
C = Commercial = 0°C to +70°C
I = Industrial = -40°C to +85°C
Operating Frequency
33 = 0-33MHz
40 = 0-40MHz
Feature Attribute
2 = Port 4 present
Feature Set and Flash Memory Size
516RD = C52 feature set + 64(72)
KByte
Note: Number in parenthesis includes an additional 8 KByte flash which can be enabled.
Voltage Range
E = 4.5-5.5V
V = 2.7-3.6V
Product Series
89 = C51 Core
1. Environmental suffix “E” denotes non-Pb solder. Environmental suffix “F” denote non-Pb
/non-Sn solder. SST non-Pb / non-Sn solder
devices are “RoHS Compliant”.
©2013 Silicon Storage Technology, Inc.
DS25093B
88
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Valid Combinations
Valid combinations for SST89E516RD2
SST89E516RD2-40-C-NJE
SST89E516RD2-40-C-TQJE
SST89E516RD2-40-I-NJE
SST89E516RD2-40-I-TQJE
Valid combinations for SST89V516RD2
SST89V516RD2-33-C-NJE
SST89V516RD2-33-C-TQJE
SST89V516RD2-33-I-NJE
SST89V516RD2-33-I-TQJE
Valid combinations for SST89E516RD
SST89E516RD-40-C-PIE
SST89E516RD-40-C-QIF
SST89E516RD-40-I-QIF
Valid combinations for SST89V516RD
SST89V516RD-33-C-PIE
SST89V516RD-33-C-QIF
SST89V516RD-33-I-QIF
Note:Valid combinations are those products in mass production or will be in mass production. Consult your SST
sales representative to confirm availability of valid combinations and to determine availability of new combinations.
©2013 Silicon Storage Technology, Inc.
DS25093B
89
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Packaging Diagrams
TOP VIEW
SIDE VIEW
BOTTOM VIEW
See notes
2 and 3
0.2
Pin #1
Pin #1
0.5 BSC
6.00 ± 0.10
4.1
0.075
0.30
0.18
4.1
0.45
0.35
0.05 Max
6.00 ± 0.10
0.80
0.70
Note: 1. Complies with JEDEC JEP95 MO-220I, variant WJJD-5 except external paddle nominal dimensions.
2. From the bottom view, the pin #1 indicator may be either a 45-degree chamfer or a half-circle notch.
3. The external paddle is electrically connected to the die back-side and possibly to certain VSS leads.
This paddle should be soldered to the PC board; it is suggested to connect this paddle to the VSS of the unit.
Connection of this paddle to any other voltage potential will result in shorts and/or electrical malfunction of the device.
4. Untoleranced dimensions are nominal target dimensions.
5. All linear dimensions are in millimeters (max/min).
1mm
40-wqfn-6x6-QI-1
Figure 47:40-contact Very-very-thin Quad Flat No-lead (WQFN)
SST Package Code: QI
©2013 Silicon Storage Technology, Inc.
DS25093B
90
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
40
CL
.600
.625
1
Pin #1 Identifier
.530
.557
2.020
2.070
.065
.075
12°
4 places
Base
Plane
Seating
Plane
.220 Max.
.015 Min.
.063
.090
Note:
.045
.055
.015
.022
.100 BSC
.100 †
.200
0°
15°
.008
.012
.600 BSC
1. Complies with JEDEC publication 95 MS-011 AC dimensions (except as noted), although some dimensions may be more stringent.
† = JEDEC min is .115; SST min is lessstringent
40-pdip-PI-7
2. All linear dimensions are in inches (min/max).
3. Dimensions do not include mold flash. Maximum allowable mold flash is .010 inches.
Figure 48:40-pin Plastic Dual In-line Pins (PDIP)
SST Package Code: PI
©2013 Silicon Storage Technology, Inc.
DS25093B
91
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
TOP VIEW
SIDE VIEW
.685
.695
.646 †
.656
Optional
Pin #1 Identifier
.042
.048
1
.020 R.
MAX.
.042 x45°
.056
44
.147
.158
.025 R.
.045
.042
.048
.685
.695
BOTTOM VIEW
.013
.021
.646 †
.656
.500
REF.
.026
.032
.590
.630
.050
BSC.
.100
.112
.050
BSC.
.165
.180
.020 Min.
.026
.032
44.PLCC.NJ-ILL.6
Note:
1. Complies with JEDEC publication 95 MS-018 AC dimensions (except as noted), although some dimensions may be more stringent.
† = JEDEC min is .650; SST min is lessstringent
2. All linear dimensions are in inches (min/max).
3. Dimensions do not include mold flash. Maximum allowable mold flash is .008 inches.
4. Coplanarity: ± 4 mils.
Figure 49:44-lead Plastic Lead Chip Carrier (PLCC)
SST Package Code: NJ
©2013 Silicon Storage Technology, Inc.
DS25093B
92
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Pin #1
Identifier
44
34
1
33
.30
.45
10.00 ± 0.10
.80 BSC
12.00 ± 0.25
11
23
12
.09
.20
22
10.00 ± 0.10
12.00 ± 0.25
.95
1.05
1.2
max.
.05
.15
.45
.75
0°- 7°
1.00 ref
Note:
1. Complies with JEDEC publication 95 MS-026 ACB dimensions, although some dimensions may be more stringent.
2. All linear dimensions are in millimeters (min/max).
44-tqfp-TQJ-7
3. Coplanarity: 0.1 (±0.05) mm.
4. Package body dimensions do not include mold flash. Maximum allowable mold flash is .25mm.
1mm
Figure 50:44-lead Thin Quad Flat Pack (TQFP)
SST Package Code: TQJ
©2013 Silicon Storage Technology, Inc.
DS25093B
93
02/13
FlashFlex MCU
SST89E516RD2 / SST89E516RD
SST89V516RD2 / SST89V516RD
Data Sheet
Table 42: Revision History
Revision
Description
•
Date
•
•
•
Initial Release of S71273 data sheet.
SST89E/V516RD2 devices were previously released in S71255-00000
S71273 and
S71273(01): Added 40-WQFN (QI) package and associated MPNs
Added SST89E/V516RD PDIP devices and associated MPNs
Clarified the solder temperature profile under “Absolute Maximum
Stress Ratings” on page 73
Added RoHS compliance information on page 1 and in the “Product
Ordering Information” on page 88
Removed references to External Host Mode programming
Corrected MPN breakdown definition for “2” to read “Port 4 present”
Corrected the SPI control Register definition for CPHA on page 30
Mar 2005
01
•
Status change from Preliminary Specifications to Data sheet
Mar 2005
02
•
•
Removed NJ, TQJ, and PI from Valid Combinations on page 78
Removed valid combination SST89E516RD-40-I-PIE and
SST89V516RD-33-I-PIE on page 78
Oct 2006
03
•
Replaced FlashFlex51 with FlashFlex globally
Jan 2007
A
•
•
•
Applied new document format
Released document under letter revision system
Updated spec number from S71273 to DS25093
Nov 2011
B
•
Removed “Not recommended for new designs” statement on page 1.
Feb 2013
00
•
•
•
•
ISBN: 978-1-62076-989-8
© 2013 Silicon Storage Technology, Inc–a Microchip Technology Company. All rights reserved.
SST, Silicon Storage Technology, the SST logo, SuperFlash, MTP, and FlashFlex are registered trademarks of Silicon Storage Technology, Inc. MPF, SQI, Serial Quad I/O, and Z-Scale are trademarks of Silicon Storage Technology, Inc. All other trademarks and
registered trademarks mentioned herein are the property of their respective owners.
Specifications are subject to change without notice. Refer to www.microchip.com for the most recent documentation. For the most current
package drawings, please see the Packaging Specification located at http://www.microchip.com/packaging.
Memory sizes denote raw storage capacity; actual usable capacity may be less.
SST makes no warranty for the use of its products other than those expressly contained in the Standard Terms and Conditions of
Sale.
For sales office locations and information, please see www.microchip.com.
Silicon Storage Technology, Inc.
A Microchip Technology Company
www.microchip.com
©2013 Silicon Storage Technology, Inc.
DS25093B
94
02/13