VISHAY RG1B

RG1A THRU RG1M
GLASS PASSIVATED FAST SWITCHING RECTIFIER
Reverse Voltage - 50 to 1000 Volts
Forward Current - 1.0 Ampere
*
FEATURES
♦ High temperature metallurgically bonded
construction
♦ Hermetically sealed package
♦ Glass passivated cavity-free junction
♦ 1.0 Ampere operation
at TA=55°C with no
thermal runaway
♦ Typical IR less than 0.1µA
♦ Capable of meeting environmental standards of
MIL-S-19500
♦ Fast switching for high efficiency
♦ High temperature soldering guaranteed:
350°C/10 seconds, 0.375" (9.5mm) lead length,
5 lbs. (2.3kg) tension
P
A
T
E
N
T
E
D
DO-204AP
0.034 (0.86)
0.028 (0.71)
DIA.
1.0 (25.4)
MIN.
0.240 (6.1)
MAX.
0.150 (3.8)
0.100 (2.5)
DIA.
1.0 (25.4)
MIN.
MECHANICAL DATA
Case: JEDEC DO204AP solid glass body
Terminals: Solder plated axial leads, solderable per
MIL-STD-750, Method 2026
Polarity: Color band denotes cathode end
Mounting Position: Any
Weight: 0.02 ounce, 0.56 gram
Dimensions in inches and (millimeters)
*Brazed-lead assembly is covered by Patent No. 3,930,306
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
SYMBOLS
RG1A
RG1B
RG1D
RG1G
RG1J
RG1K
RG1M
UNITS
Maximum repetitive peak reverse voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS voltage
VRMS
35
70
140
280
420
560
700
Volts
Maximum DC blocking voltage
VDC
50
100
200
400
600
800
1000
Volts
Maximum average forward rectified current
0.375” (9.5mm) lead length at TA=55°C
I(AV)
1.0
Amp
Peak forward surge current
8.3ms single half sine-wave superimposed
on rated load (JEDEC Method)
IFSM
30.0
Amps
VF
1.3
Volts
IR(AV)
1.0
100.0
µA
Maximum DC reverse current
at rated DC blocking voltage
IR
2.0
µA
Maximum reverse recovery time (NOTE 1)
trr
Typical junction capacitance (NOTE 2)
CJ
15.0
pF
RΘJA
55.0
°C/W
TJ, TSTG
-65 to +175
°C
Maximum instantaneous forward voltage at 1.0A
Maximum full load reverse current,
full cycle average 0.375” (9.5mm)
lead length at
TA=25°C
TA=100°C
Typical thermal resistance (NOTE 3)
Operating junction and storage temperature range
NOTES:
(1) Reverse recovery test conditions: IF=0.5A, IR=1.0A, Irr=0.25A
(2) Measured at 1.0 MHZ and applied reverse voltage of 4.0 Volts
(3) Thermal resistance from junction to ambient at 0.375” (9.5mm) lead length, P.C.B. mounted
4/98
150
200
250
500
ns
RATINGS AND CHARACTERISTIC CURVES RG1A AND RG1M
FIG. 2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
PEAK FORWARD SURGE CURRENT,
AMPERES
AVERAGE FORWARD RECTIFIED CURRENT,
AMPERES
30
FIG. 1 - FORWARD CURRENT DERATING CURVE
1.0
RESISTIVE OR
INDUCTIVE LOAD
0.8
Ipk/IAV=π
0.6
CAPACITANCE
LOAD
5.0
Ipk/IAV=
10
20
0.4
TA=25°C
8.3ms SINGLE HALF
SINE-WAVE(JEDEC Method)
20
10
0.2
0
0.375" (9.5mm) LEAD LENGTH
0
0
25
50
75
125
175
150
100
10
1
100
NUMBER OF CYCLES AT 60 HZ
AMBIENT TEMPERATURE, °C
FIG. 4 - TYPICAL REVERSE CHARACTERISTICS
20
FIG. 3 - TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
10
INSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
20
TJ=25°C
PULSE WIDTH=300µs
1% DUTY CYCLE
1
0.1
TJ=125°C
1
TJ=75°C
0.1
TJ=25°C
0.01
0.4
0.6
0.8
1.0
1.2
1.4
1.6
0.01
0
1.8
20
FIG. 5 - TYPICAL JUNCTION CAPACITANCE
30
TJ=25°C
f=1.0 MHz
Vsig, 50mVp-p max.
10
1
1
40
60
80
100
PERCENTAGE OF RATED PEAK REVERSE
VOLTAGE, %
INSTANTANEOUS FORWARD VOLTAGE, VOLTS
JUNCTION CAPACITANCE, pF
INSTANTANEOUS FORWARD CURRENT,
AMPERES
10
10
REVERSE VOLTAGE, VOLTS
100