OMRON G3VM

G3VM-61PR1
MOS FET Relays
Smallest Class in market, USOP
Package MOS FET Relays with
Low Output Capacitance and ON
Resistance (CxR=7pF·Ω)
• Dielectric strength of 500Vrms between I/O.
Note: The actual product is marked differently from the
image shown here.
RoHS Compliant
Refer to "Common Precautions".
■Application Examples
■Terminal Arrangement/Internal Connections
• Communication
• Semiconductor test
OMRON mark
• Data loggers
• Test & measurement
Model name
6P1
equipment
equipment
LOT No.
103
equipment
Note: The actual product is marked differently from the image shown here.
■List of Models
Package type
USOP4
Contact form
1a
(SPST-NO)
Load voltage (peak value)
(See note.)
Terminals
Minimum package quantity
Model
Number per tape & reel
−
G3VM-61PR1
Surface-mounting terminals
60V
G3VM-61PR1(TR05)
500
G3VM-61PR1(TR)
1,500
Note 1. Ask you OMRON representative for orders under 1,500 pcs or 500 pcs.
2. Tape-cut USOPs are packaged without humidity resistance. Use manual soldering to mount them. Refer to common precautions.
3. The AC peak and DC value is given for the load voltages.
■Absolute Maximum Ratings (Ta = 25°C)
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Output
G
3
V
M
I
6
1
P
R
1
Item
LED forward current
Input
U
S
O
P
Continuous load current (AC peak/DC)
Symbol
Rating
Unit
IF
50
mA
ΔIF/°C
−0.5
mA/°C
VR
5
V
°C
TJ
125
VOFF
60
V
IO
120
mA
ΔIO/°C
−1.2
mA/°C
Pulse ON current
lop
360
mA
Connection temperature
TJ
125
°C
ON current reduction rate
Measurement conditions
Ta≥25°C
Ta≥25°C
t=100ms, Duty=1/10
Dielectric strength between I/O (See note 1.)
VI-O
500
Vrms
Ambient operating temperature
Ta
−40~+85
°C
Tstg
−40~+125
°C
With no icing or condensation
−
260
°C
10s
Ambient storage temperature
Soldering temperature
AC for 1 min
With no icing or condensation
Note: 1.The dielectric strength
between the input and output
was checked by applying
voltage between all pins as a
group on the LED side and all
pins as a group on the lightreceiving side.
■Electrical Characteristics (Ta = 25°C)
Item
Symbol Minimum Typical Maximum Unit
Measurement conditions
Input
Output
LED forward voltage
VF
1.0
1.15
1.3
V
IF=10mA
Reverse current
IR
−
−
10
μA
VR=5V
Capacity between terminals
CT
−
15
−
pF
V=0, f=1MHz
Trigger LED forward current
IFT
−
1.0
3
mA
IO=100mA
Maximum resistance with output ON
RON
−
10
15
Ω
IF=5mA, IO=120mA, t<1s
Current leakage when the relay is open
ILEAK
−
−
1
nA
VOFF=60V
Capacity between terminals
V=0, f=100MHz, t<1s
COFF
−
0.7
1.3
pF
Capacity between I/O terminals
CI-O
−
0.4
−
pF
f=1MHz, VS=0V
Insulation resistance between I/O terminals
RI-O
1000
−
−
MΩ
VI-O=500VDC, ROH≤60%
Turn-ON time
tON
−
0.04
0.2
ms
Turn-OFF time
tOFF
−
0.12
0.2
ms
IF=5mA, RL=200Ω,
VDD=20V (See note 2.)
1
Note: 2.Turn-ON and Turn-OFF
Times
IF
1
4
2
3
RL
VDD
VOUT
IF
VOUT
10%
t ON
90%
t OFF
G3VM-61PR1
MOS FET Relays
■Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly
Item
Symbol
Minimum
Typical
Maximum
VDD
−
−
48
V
IF
5
7.5
20
mA
Load voltage (AC peak/DC)
Operating LED forward current
Unit
Continuous load current (AC peak/DC)
IO
−
−
120
mA
Ambient operating temperature
Ta
−20
−
65
°C
■Engineering Data
Continuous load current vs.
Ambient temperature
LED forward current vs.
Ambient temperature
IO - Ta
60
50
40
30
20
IF - VF
150
LED forward current IF (mA)
Continuous load current IO (mA)
IF - Ta
LED forward current IF (mA)
LED forward current vs.
LED forward voltage
100
50
100
Ta = 25°C
10
1
10
0
-40
-20
0
20
40
60
80
Continuous load current vs.
On-state voltage
-40
-20
0
20
IO - VON
60
80
100
IF=5mA
t<1s
50
0
-50
Io=120mA
IF=5mA
t<1s
10
5
0.5
1
1.5
-40
-20
0
20
On-state voltage VON (V)
Turn ON, Turn OFF time vs.
LED forward current
1
100
-20
0
t OFF
100
10
t ON
RL=200Ω
Ta=25°C
1
10
100
20
40
60
80
100
Ambient temperature Ta (°C)
U
S
O
P
Current leakage vs. Load voltage
tON, tOFF - Ta
Turn ON, Turn OFF time tON, tOFF (μs)
Turn ON, Turn OFF time tON, tOFF (μs)
80
Io=100mA
t<1s
Ambient temperature Ta (°C)
tON, tOFF - IF
1
60
Turn ON, Turn OFF time vs.
Ambient temperature
1000
VDD=20V
40
ILEAK - VOFF
Current leakage ILEAK (pA)
0
2
0
-40
0
-0.5
1.6
IFT - Ta
20
15
1.4
Trigger LED forward current vs.
Ambient temperature
-100
-1
1.2
LED forward voltage VF (V)
Trigger LED forward current IFT (mA)
Ta = 25°C
-150
-1.5
1
RON - Ta
On-state resistance RON (Ω)
Continuous load current IO (mA)
40
Ambient temperature Ta (°C)
On-state resistance vs.
Ambient temperature
150
100
0.1
0.8
0
100
Ambient temperature Ta (°C)
1000
t OFF
100
t ON
10
100
Ta = 25°C
80
G
3
V
M
I
6
1
P
R
1
60
40
VDD=20V
20
RL = 200Ω
IF=5mA
1
-40
-20
LED forward current IF (mA)
0
20
40
60
80
100
Ambient temperature Ta (°C)
0
0
10
20
30
40
50
60
Load voltage VOFF(v)
Output terminal capacitance
COFF/COFF(ov) vs. Load voltage
Output terminal capacitance COFF/COFF(ov)
COFF - VOFF
1
Ta = 25°C
0.8
0.6
0.4
0.2
0
0
10
20
30
40
Load voltage VOFF(v)
■Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Apperance/Dimensions
USOP4
■Appearance
USOP (Ultra Small Outline Package)
USOP4
6P1
Model name
OMRON mark
103
LOT No.
Note: The actual product is marked differently from the image shown here.
■Dimensions
6P1
(Unit: mm)
Surface-mounting Terminals
103
Actual Mounting Pad Dimensions
Weight: 0.03g
(Recommended Value, Top View)
3.25
2.05
0.85
2.9
0.15 1.65
(0.4)
1.27
2.2
0.8
0.2
2.85
1.27
(0.35)
Note: The actual product is marked differently from the image shown here.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K212-E1-02
1112(0912)(O)