OMRON Z01HB

GENERAL PURPOSE
Basic Switch
Z
General Purpose Basic Switch
High precision basic switch in a variety
of styles
■ Wide margins of operating conditions
increase the operating speed range
■ Available in general purpose and dripproof types
■
Ordering Information
Pin plunger
Slim spring
plunger
Short spring
plunger
Spring
plunger
Panel mount
plunger
Panel mount
roller plunger
Hinge lever
Low-force
hinge lever
Low-force wire
hinge lever
Short hinge
roller lever
Hinge roller
lever
Unidirectional
short hinge
roller lever
Panel mount
cross roller plunger
Flexible rod
GENERAL PURPOSE TYPE
Standard
Actuator
Pin plunger
Slim spring plunger
Short spring plunger
Panel mount plunger
Panel mount roller plunger
Panel mount cross roller plunger
Hinge lever
Low-force hinge lever
Short hinge roller lever
Hinge roller lever
Unidirectional short hinge roller lever
Operating
Characteristics
Low OP
Middle OP
Low OF
Parallel
Low OF
Rated Current
15 A
15 A
15 A
15 A
15 A
15 A
15 A
15 A
15 A
15 A
15 A
Part Number
Solder Terminal
Z-15G
Z-15GS
Z-15GD
Z-15GQ
Z-15GQ22
Z-15GQ21
Z-15GW
Z-15GW4
Z-15GW22
Z-15GW2
Z-15GW2277
Screw Terminal
Z-15G-B
Z-15GS-B
Z-15GD-B
Z-15GQ-B
Z-15GQ22-B
Z-15GQ21-B
Z-15GW-B
Z-15GW4-B
Z-15GW22-B
Z-15GW2-B
Z-15GW2277-B
Z
Z
GENERAL PURPOSE TYPE
High-sensitivity
Actuator
Pin plunger
Low-force hinge lever
Low-force, wire hinge lever
Short hinge roller lever
Operating
Characteristics
Rated Current
15 A
15 A
15 A
15 A
Part Number
Solder Terminal
—
—
Z-15HW78
—
Screw Terminal
Z-15H-B
Z-15HW24-B
Z-15HW78-B
Z-15HW22-B
Parallel
High OF
Rated
Current
15 A
15 A
15 A
15 A
15 A
15 A
15 A
15 A
15 A
15 A
15 A
Contact
Gap
0.5 mm
0.5 mm
0.5 mm
0.5 mm
0.5 mm
0.5 mm
0.5 mm
0.5 mm
0.5 mm
0.5 mm
0.5 mm
Part Number
Solder Terminal
Z-15GS55
Z-15GD55
Z-15GK55
Z-15GK355
Z-15GQ55
—
—
Z-15GW55
Z-15GW2255
Z-15GW255
Z-15GNJ55
Screw Terminal
Z-15GS55-B
Z-15GD55-B
Z-15GK55-B
Z-15GK355-B
Z-15GQ55-B
Z-15GQ2255-B
Z-15GQ2155-B
Z-15GW55-B
Z-15GW2255-B
Z-15GW255-B
Z-15GNJ55-B
Operating
Characteristics
Middle OP
High OF
Rated
Current
15 A
15 A
Contact
Gap
0.25 mm
0.25 mm
Part Number
Solder Terminal
—
—
Screw Terminal
Z-15HQ55-B
Z-15HNJS55-B
Low OF
DRIP-PROOF TYPE
Standard
Operating
Characteristics
Actuator
Slim spring plunger
Short spring plunger
Spring plunger
Panel mount plunger
Panel mount roller plunger
Panel mount cross roller plunger
Hinge lever
Short hinge roller lever
Hinge roller lever
Flexible rod
Middle OP
High OP
Middle OP
Low OF
DRIP-PROOF TYPE
High-sensitivity
Actuator
Panel mount plunger
Flexible rod
Note: For smaller mounting hole types, please consult OMRON.
■ BASIC CONTACT FORM
Type
General purpose
Drip-proof
Contact gap
H: 0.25 mm
(high sensitivity)
G: 0.5 mm (standard)
H: 0.25 mm
(high sensitivity)
G: 0.5 mm (standard)
Features
Pin plunger and lever types available.
Drip-proof and flexible rod types are also available.
The pin plunger is sealed from the other switch mechanisms by a resilient rubber,
and the case and cover are sealed by adhesive so that the switch is resistant to
humidity, oil and dust. The degree of protection conforms to IEC IP63.
Basic Contact form
2
Z
Z
Specifications
Standard type (except flexible rod types)
Contact
gap
Rated
voltage
G,H
125 VAC
250 VAC
500 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
G
H
Non-inductive load (A)
Resistive load
Lamp load
NC
NO
NC
NO
15 (10) —
3
1.5
15 (10) —
2.5
1.25
10
—
1.5
0.75
15
—
3
1.5
15
—
3
1.5
6
—
3
1.5
0.5
—
0.5
0.5
0.25
—
0.25
0.25
15
—
3
1.5
15
—
3
1.5
2
—
2
1.4
0.4
—
0.4
0.4
0.2
—
0.2
0.2
Inductive load (A)
Inductive load
NC
NO
15 (10) —
15 (10) —
6
—
15
—
10
—
5
—
0.05
—
0.03
—
15
—
10
—
1
—
0.03
—
0.02
—
Motor load
NC
NO
5
2.5
3
1.5
1.5
0.75
5
2.5
5
2.5
5
2.5
0.05
0.05
0.03
0.03
5
2.5
5
2.5
1
1
0.03
0.03
0.02
0.02
Inrush current (A)
NC
NO
30 max.
15 max.
Inductive load (A)
Inductive load
NC
NO
7
—
5
—
7
—
7
—
1
—
0.03
—
0.02
—
Motor load
NC
NO
2.5
2
1.5
1
3
1.5
3
1.5
1
0.5
0.03
0.03
0.02
0.02
Inrush current (A)
NC
NO
30 max.
15 max.
Standard flexible rod types
Non-inductive load (A)
Resistive load
Lamp load
NC
NO
NC
NO
15
—
2
1
15
—
1
0.5
15
—
2
1
15
—
2
1
2
—
2
1
0.4
—
0.4
0.4
0.2
—
0.2
0.2
Rated
voltage
125 VAC
250 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
■ CONSTRUCTION
Drip-proof type
Rubber cap protects the built-in switch from
water and dust
Fixed contact (NC)
Glued surface (adhesive is filled between
case and cover)
Movable contact
Spring pivot
Fixed contact (NC)
Movable spring
3
Z
Z
Characteristics
Operating speed
Operating frequency
Mechanical
Electrical
Insulation resistance
Contact resistance
Dielectric strength (VAC)
G contact gap model
H contact gap model
Vibration
Malfunction
Shock
Mechanical durability
Malfunction
Standard types
Drip-proof types
Standard types
Drip-proof types
Mechanical
Ambient temperature
Humidity
Service life
Electrical
Weight
Note: 1.
2.
3.
4.
Standard
Standard flexible rod types
(except flexible rod types)
(coil spring and steel wire type)
0.01 mm to 1 m/second (see note 2)
1 mm to 1 m/second
240 operations/min.
120 operations/min.
20 operations/min.
20 operations/min.
100 MΩ min. (at 500 VDC)
50 mΩ max. (initial)
15 mΩ max. (initial)
1,000 VAC, 50/60 Hz for 1 minute between terminals of same polarity
600 VAC, 50/60 Hz for 1 minute
2,000 VAC, 50/60 Hz for 1 minute between current carrying metal parts and
ground and between each terminal and non-current carrying metal parts
10 to 55 Hz, 1.5 mm
10 to 20 Hz, 1.5 mm
double amplitude (see note 4)
double amplitude
1,000 m/s2 min. (approx. 100 g)
300 m/s2 min. (approx. 30 g) (see note 3)
50 m/s2 min. (approx. 5 g)
-25° to 80°C (with no icing)
-15° to 80°C (with no icing)
35% to 85% RH
35% to 95% RH
G, H contact gap models
1,000,000 operations min.
20,000,000 operations min. (see note 4)
G, H contact gap models
100,000 operations min.
500,000 operations min. (see note 2)
Approx. 22 to 58 g
Approx. 42 to 48 g
Data shown are of initial value.
Apply to the pin plunger models or the pin plunger of the lever models.
Apply to Z-15G.
Apply to the pin plunger models.
■ ACCESSORIES (order separately)
Operating Characteristics (when used with Z-15)
Characteristics
OF max.
RF min.
PT max.
OT min.
MD max.
FP max.
OP
ZAA-1
w/Z-15G-B
500 g
170 g
—
12.7 mm
2.2 mm
34.5 mm
28.9±1.6 mm
ZAA-2
w/Z-15G-B
500 g
170 g
—
12.7 mm
2.2 mm
46.1 mm
40.4±1.6 mm
Terminal enclosures - Standard models
Material
Phenolic resin
Metal
Polyvinyl chloride
4
Mounting method
Side mounting
Side mounting
Side mounting
For solder terminal
AP-A
AP1-A
AP-Z
For screw terminal
AP-B
AP1-B
AP-Z
Remarks
—
Use in conjunction with AP-A and AP-B
Excels in safety and dust-proofing property
Z
Z
Mechanical service life
Z-15G
Electrical service life
Z-15G
Number of operations (x106)
Number of operations (x104)
■ CHARACTERISTIC DATA
Overtravel (mm)
Switching current (A)
5
Z
Z
Dimensions
Unit: mm (inch)
Z-15G-B, Z-15H-B
Operating
characteristics
OF
RF min.
PT max.
OT min.
MD max.
OP
Z-15G-B
250 to 350 g
114 g
.4 mm (0.02)
.13 mm (0.01)
.05 mm (0.002)
15.9 ± 0.4 mm
(0.63 ± 0.02)
Z-15H-B
200 to 280 g
114 g
.3 mm (0.01)
.13 mm (0.01)
.025 mm (0.001)
15.9 ± 0.4 mm
(0.63 ± 0.02)
Z-15GS-B
Operating
characteristics
OF
RF min.
PT max.
OT min.
MD max.
OP
Z-15GS-B
250 to 350 g
114 g
0.4 mm (0.02)
1.6 mm (0.06)
0.05 mm (0.002)
28.2 ± 0.5 mm
(1.1 ± 0.02)
Z-15GD-B
Operating
characteristics
OF
RF min.
PT max.
OT min.
MD max.
OP
Z-15GD-B
250 to 350 g
114 g
0.4 mm (0.02)
1.6 mm (0.06)
0.05 mm (0.002)
21.5 ± 0.5 mm
(0.85 ± 0.02)
Note: 1. Unless otherwise specified, a tolerance of ± 0.4 mm applies to all dimensions.
2. For smaller diameter mounting holes, please consult OMRON.
3. All drawings show the switches with screw terminals. For solder terminals, remove the “-B” from the end of the part number.
6
Z
Z
Z-15GQ-B
Operating
characteristics
OF
RF min.
PT max.
OT min.
MD max.
OP
Z-15GQ-B
250 to 350 g
114 g
0.4 mm (0.02)
5.5 mm (0.22)
0.05 mm (0.002)
21.8 ± 0.8 mm
(0.86 ± 0.03)
Z-15GQ22-B
Operating
characteristics
OF
RF min.
PT max.
OT min.
MD max.
OP
Z-15GQ22-B
250 to 350 g
114 g
0.4 mm (0.02)
3.58 mm (0.14)
0.05 mm (0.002)
33.4 ± 1.2 mm
(1.31 ± 0.05)
Z-15GQ21-B
Operating
characteristics
OF
RF min.
PT max.
OT min.
MD max.
OP
Z-15GQ21-B
250 to 350 g
114 g
0.4 mm (0.02)
3.58 mm (0.14)
0.05 mm (0.002)
33.4 ± 1.2 mm
(1.31 ± 0.05)
Note: 1. Unless otherwise specified, a tolerance of ± 0.4 mm applies to all dimensions.
2. For smaller diameter mounting holes, please consult OMRON.
3. All drawings show the switches with screw terminals. For solder terminals, remove the “-B” from the end of the part number.
7
Z
Z
Unit: mm (inch)
Z-15GW-B
Operating
characteristics
OF max.
RF min.
OT min.
MD max.
FP max.
OP
Z-15GW-B
70 g
14 g
5.6 mm (0.22)
1.27 mm (0.05)
28.2 mm (1.11)
19 ± 0.8 mm
(0.75 ± 0.03)
Z-15GW4-B
Operating
characteristics
OF max.
RF min.
PT max.
OT min.
MD max.
OP
Z-15GW4-B
28 g
3.5 g
10 mm (0.39)
5.6 mm (0.22)
1.27 mm (0.05)
19 ± 0.8 mm
(0.75 ± 0.03)
Z-15HW24-B
Operating
characteristics
OF max.
RF min.
PT max.
OT min.
MD max.
OP
Z-15HW24-B
6g
0.5 g
19.8 mm (0.78)
10 mm (0.39)
2 mm (0.08)
19.8 ± 1.6 mm
(0.75 ± 0.03)
Z-15HW78-B
Operating
characteristics
OF max.
RF min.
PT max.
OT min.
MD max.
OP
Z-15HW78-B
4g
0.3 g
10 mm (0.39)
6 mm (0.24)
3 mm (0.12)
20 ± 1 mm
(0.79 ± 0.04)
Note: 1. Unless otherwise specified, a tolerance of ± 0.4 mm applies to all dimensions.
2. For smaller diameter mounting holes, please consult OMRON.
3. All drawings show the switches with screw terminals. For solder terminals, remove the “-B” from the end of the part number.
8
Z
Z
Z-15GW22-B, Z-15HW22-B
Operating
characteristics
OF max.
RF min.
OT min.
MD max.
FP max.
OP
Z-15GW22-B
160 g
42 g
2.4 mm (0.09)
0.5 mm (0.02)
32.5 mm (1.28)
30.2 ± 0.4 mm
(1.19 ± 0.02)
Z-15HW22-B
150 g
42 g
2.4 mm (0.09)
0.45 mm (0.02)
32.5 mm (1.28)
30.2 ± 0.4 mm
(1.19 ± 0.02)
Z-15GW2-B
Operating
characteristics
OF max.
RF min.
OT min.
MD max.
FP max.
OP
Z-15GW2-B
100 g
22 g
4 mm (0.16)
1.02 mm (0.04)
36.5 mm (1.44)
30.2 ± 0.8 mm
(1.19 ± 0.03)
Z-15GW2277-B
Operating
characteristics
OF max.
RF min.
OT min.
MD max.
FP max.
OP
Z-15GW2277-B
170 g
42 g
2.4 mm (0.09)
0.51 mm (0.02)
43.6 mm (1.72)
41.3 ± 0.8 mm
(1.63 ± 0.03)
Note: 1. Unless otherwise specified, a tolerance of ± 0.4 mm applies to all dimensions.
2. For smaller diameter mounting holes, please consult OMRON.
3. All drawings show the switches with screw terminals. For solder terminals, remove the “-B” from the end of the part number.
9
Z
Z
Operating
characteristics
OF max.
RF min.
PT max.
OT min.
MD max.
OP
Z-15GS55-B
540 g
114 g
1.9 mm (0.07)
1.6 mm (0.06)
0.06 mm (0.002)
28.2 ± 0.5 mm
(1.11 ± 0.02)
Z-15GD55-B
Operating
characteristics
OF max.
RF min.
PT max.
OT min.
MD max.
OP
Z-15GD55-B
540 g
114 g
1.8 mm (0.07)
1.6 mm (0.06)
0.06 mm (0.002)
21.5 ± 0.5 mm
(.85 ± 0.02)
Z-15GK55-B
Operating
characteristics
OF max.
RF min.
PT max.
OT min.
MD max.
OP
Z-15GK55-B
540 g
114 g
2.3 mm (0.09)
1.6 mm (0.06)
0.06 mm (0.002)
28.2 ± 0.5 mm
(1.11 ± 0.02)
Note: 1. Unless otherwise specified, a tolerance of ± 0.4 mm applies to all dimensions.
2. For smaller diameter mounting holes, please consult OMRON.
3. All drawings show the switches with screw terminals. For solder terminals, remove the “-B” from the end of the part number.
10
Z
Z
Z-15GK355-B
Operating
characteristics
OF max.
RF min.
PT max.
OT min.
MD max.
OP
Z-15GK355-B
540 g
114 g
2.4 mm (0.09)
3.5 mm (0.14)
0.06 mm (0.002)
37.8 ± 1.2 mm
(1.49 ± 0.05)
Z-15GQ55-B, Z-15HQ55-B
Operating
characteristics
OF max.
RF min.
PT min.
OT min.
MD max.
OP
Z-15GQ55-B
540 g
114 g
1.8 mm (0.07)
5.5 mm (0.22)
0.06 mm (0.002)
21.8 ± 0.8 mm
(0.86 ± 0.03)
Z-15GH55-B
400 g
114 g
1.7 mm (0.07)
5.5 mm (0.22)
0.04 mm (0.002)
21.8 ± 0.8 mm
(0.86 ± 0.03)
Z-15GQ2255-B
Operating
characteristics
OF max.
RF min.
PT max.
OT min.
MD max.
OP
Z-15GQ2255-B
540 g
114 g
1.8 mm (0.07)
3.58 mm (0.14)
0.06 mm (0.002)
33.4 ± 1.2 mm
(1.31 ± 0.05)
Note: 1. Unless otherwise specified, a tolerance of ± 0.4 mm applies to all dimensions.
2. For smaller diameter mounting holes, please consult OMRON.
3. All drawings show the switches with screw terminals. For solder terminals, remove the “-B” from the end of the part number.
11
Z
Z
Unit: mm (inch)
Z-15GQ2155-B
Operating
characteristics
OF max.
RF min.
PT max.
OT min.
MD max.
OP
Z-15GQ2155-B
540 g
114 g
1.8 mm (0.07)
3.58 mm (0.14)
0.06 mm (0.002)
33.4 ± 1.2 mm
(1.31 ± 0.05)
Z-15GW55-B
Operating
characteristics
OF max.
RF min.
OT min.
MD max.
FP max.
OP
Z-15GW55-B
100 g
14 g
5.6 mm (0.22)
2 mm (0.08)
28.2 mm (1.11)
19 ± 0.8 mm
(0.75 ± 0.03)
Z-15GW2255-B
Operating
characteristics
OF max.
RF min.
OT min.
MD max.
FP max.
OP
Z-15GW2255-B
200 g
42 g
2.44 mm (0.10)
0.8 mm (0.03)
32.9 mm (1.30)
30.2 ± 0.4 mm
(1.19 ± 0.02)
Z-15GW255-B
Operating
characteristics
OF max.
RF min.
OT min.
MD max.
FP max.
OP
Z-15GW255-B
130 g
21 g
4 mm (0.16)
1.6 mm (0.06)
36.5 mm (1.44)
30.2 ± 0.8 mm
(1.19 ± 0.03)
Note: 1. Unless otherwise specified, a tolerance of ± 0.4 mm applies to all dimensions.
2. For smaller diameter mounting holes, please consult OMRON.
3. All drawings show the switches with screw terminals. For solder terminals, remove the “-B” from the end of the part number.
12
Z
Z
Z-15GNJ55-B
Operating
characteristics
OF max.
PT max.
Z-15GNJ55-B
50 g
20 mm* (0.79)
* Reference value
Z-15HNJS55-B
Operating
characteristics
OF max.
PT max.
Z-15HNJ55-B
15 g
25 mm* (0.98)
* Reference value
Note: 1. Unless otherwise specified, a tolerance of ± 0.4 mm applies to all dimensions.
2. For smaller diameter mounting holes, please consult OMRON.
3. All drawings show the switches with screw terminals. For solder terminals, remove the “-B” from the end of the part number.
13
Z
Z
Unit: mm (inch)
■ MOUNTING HOLES
Side mounting
Panel mounting plunger type
Roller plunger type
■ TERMINALS
Solder terminal (blank)
Screw terminal (B)
Three M4 x 5.5 dia.
Terminal screws
(with tooth washers)
■ MOLDED TERMINAL TYPE
ORDERING INFORMATION
-M■
■■
Lead outlet directions
(L, R, D, F, H)
The solder terminal type can be supplied with
molded terminals with a choice of five different lead
outlet directions. When placing your order for the
molded terminal type, add the following code to the
model number.
Note: 1.
2.
3.
4.
5.
Mold thickness
(No symbol)…a = 12 mm
with VSF
19…a = 19 mm with VCT
Standard leads are single-core vinyl cords (VSF) with a nominal cross sectional area of 1.25 mm2.
Standard vinyl cord lengths are 1 m, 3 m, and 5 m.
Mold thickness will be 19 mm when using VCT cords.
Standard unit has three lead outlets in the same direction.
Connect the black lead to the COM terminal, white lead to the NO terminal, and red lead to the NC terminal, respectively.
■ DIRECTIONS OF LEAD OUTLETS
The following diagrams show the molded terminal version of sealed type Z-15GW2255, with a mold thickness of 12 mm.
Z-15GW2255-ML
(left-hand)
Z-15GW2255-MF
(forward)
Z-15GW2255-MR
(right-hand)
Z-15GW2255-MH
(rearward)
Z-15GW2255-MD
(underside)
Note: Respective directions of lead outlets are determined with the plunger viewed on your left.
■ LEAD WIRE SPECIFICATIONS
Type
VSF (single-core, vinyl cord)
VCT (vinyl-insulated cable)
14
Nominal crosssectional area (mm2)
1.25
Finished outer
diameter (mm)
Approx. 3.1
Approx. 9.6 (2-core)
Approx. 10.5 (3-core)
Connection to
terminal
Black-COM
White-NO
Red-NC
Length (m)
0.5, 1, 2, 3, 5
(standard)
Z
Z
■ ACCESSORIES, order separately
Hinge lever
ZAA-1
Hinge roller lever
ZAA-2
Panel mount plunger
ZAQ-3
Operating
characteristics
OF max.
RF min.
RT max.
OT min.
MD max.
OP
ZAQ-3 with Z-15G
550 g
144 g
1 mm (0.04 in)
4.5 mm (0.18 in)
0.2 mm (0.01 in)
27.8±1.5 mm
(1.09±0.06 in)
Panel mount plunger
ZAQ-2
Operating
characteristics
OF max.
RF min.
RT max.
OT min.
MD max.
OP
ZAQ-2 with Z-15G
550 g
144 g
1 mm (0.04 in)
4.5 mm (0.18 in)
0.2 mm (0.01 in)
53.2±1.5 mm
(2.09±0.06 in)
Note: Unless otherwise specified, a tolerance of ± 0.8 mm applies to all dimensions.
15
Z
Z
Panel mount plunger
ZAQ-1
Operating
characteristics
OF max.
RF min.
RT max.
OT min.
MD max.
OP
ZAQ-1 with Z-15G
550 g
144 g
1 mm (0.04 in)
20.4 mm (0.80 in)
0.2 mm (0.01 in)
69.1±1.5 mm
(2.72±0.06 in)
Note: Unless otherwise specified, a tolerance of ± 0.8 mm applies to all dimensions.
AP-A (for solder terminal)
AP1-A (for solder terminal)
AP1-B
AP-Z
Note: Unless otherwise specified, a tolerance of ± 0.4 mm applies to all dimensions.
16
AP-B (for screw terminal)
Z
Z
■ CABLE OUTLET DIMENSIONS
A-A section
B-B section
Note: The cable outlet is provided with two stepped openings (6 dia. and 8 dia.) to permit the use of either opening according to the
finished OD of the cable to be connected.
■ APPROVALS
UL (File No. E41515)/CSA (File No. LR21642)/SEV (File No. S20/163)
Type
Z-15 Series
Rating
15 A 125, 250 or 480 VAC
1/2 A 125 VDC, 1/4 A 250 VDC
1/8 HP 125 VAC, 1/4 A 250 VAC
Note: The rated values approved by each of the safety standards (e.g. UL/CSA) may be different from the performance characteristics
individually defined in this catalog.
Precautions
■ OPERATION
High sensitivity switch (Z-15H)
When using the switch in a DC circuit, be sure to provide an arc
suppressor as well because the small contact gap of the switch
may result in contact troubles.
In an application where a high repeat accuracy is required, limit
17
Z
OMRON ELECTRONICS, INC.
OMRON CANADA, INC.
One East Commerce Drive
Schaumburg, IL 60173
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. GC SW5
18
Z
4/98
Specifications subject to change without notice.
Printed in the U.S.A.