Solid State Sensors
Linear Current Sensors
CS Series
FEATURES
1 Linear output
1 AC or DC current sensing
1 Through-hole design
1 Fast response time
1 Output voltage isolation from input
1 Minimum energy dissipation
1 Maximum current limited only by
conductor size
1 Adjustable performance and built-in
temperature compensation assures
reliable operation
1 Accurate, low cost sensing
1 Operating temperature range – 25 to
85°C
1 Housing: PET polyester
LINEAR CURRENT SENSORS
MICRO SWITCH CS series linear current
sensors incorporate our 91SS12-2 and
SS94A1 linear output Hall effect transducer (LOHETTM). The sensing element is assembled in a printed circuit board mountable housing. This housing is available in
four configuration as shown in mounting
dimension figures 1, 1a, 2 and 2a. Normal
mounting is with 0.375 inch long 4-40
screw and square nut (not provided) inserted in the housing or a 6-20 self-tapping screw. The combination of the sensor, flux collector, and housing comprises the holder assembly. These sensors
are ratiometric.
ORDER GUIDE — BOTTOM MOUNT WITH 9SS SENSOR, SOURCE OUTPUT
Catalog
Listing
Mtg.
Dim.
Fig.
Supply
Volt.
(Volts DC)
Supply
Current
(mA Max.)
Sensed
Current
(Amps
Peak)
Offset
Volt.
(Volts±10%)
Sensitivity
mV&N*
At 12 VDC
Nominal
± TOL
Offset
Shift
(%/°C)
Response
Time
(µ Sec.)
CSLA1CD
1
8 to 16
19
57
Vcc/2
49.6
5.8
±.05
3
CSLA1CE
1
8 to 16
19
75
Vcc/2
39.4
4.4
±.05
3
CSLA1DE
2
8 to 16
19
75
Vcc/2
39.1
4.8
±.05
3
CSLA1CF
1
8 to 16
19
100
Vcc/2
29.7
2.7
±.05
3
CSLA1DG
2
8 to 16
19
120
Vcc/2
24.6
2.1
±.05
3
CSLA1CH
1
8 to 16
19
150
Vcc/2
19.6
1.8
±.05
3
CSLA1DJ
2
8 to 16
19
225
Vcc/2
13.2
1.2
±.05
3
CSLA1EJ
1a
8 to 16
19
225
Vcc/2
13.2
1.5
±.05
3
CSLA1DK
2
8 to 16
19
325
Vcc/2
9.1
1.7
±.05
3
CSLA1EK
1a
8 to 16
19
325
Vcc/2
9.4
1.3
±.05
3
CSLA1EL
1a
8 to 16
19
625
Vcc/2
5.6
1.3
±.05
3
BOTTOM MOUNT WITH SS9 SENSOR, SINK/SOURCE OUTPUT
Catalog
Listing
Mtg.
Dim.
Fig.
Supply
Volt.
(Volts DC)
Supply
Current
(mA Max.)
Sensed
Current
(Amps
Peak)
Offset
Volt.
(Volts±2%)
Sensitivity
mV&N*
At 8 VDC
Nominal
± TOL
Offset
Shift
(%/°C)
Response
Time
(µ Sec.)
CSLA2CD
1
6 to 12
20
72
Vcc/2
32.7
3.0
±.02
3
CSLA2CE
1
6 to 12
20
92
Vcc/2
26.1
2.1
±.02
3
CSLA2DE
2
6 to 12
20
92
Vcc/2
25.6
2.2
±.02
3
CSLA2CF
1
6 to 12
20
125
Vcc/2
19.6
1.3
±.02
3
CSLA2DG
2
6 to 12
20
150
Vcc/2
16.2
1.1
±.02
3
CSLA2DJ
2
6 to 12
20
225
Vcc/2
8.7
0.6
±.020
3
CSLA2DH
2
6 to 12
20
235
Vcc/2
9.8
1.1
±.0125
3
CSLA2EJ
1a
6 to 12
20
310
Vcc/2
7.6
0.7
±.0125
3
CSLA2DK
2
6 to 12
20
400
Vcc/2
5.8
0.5
±.0125
3
CSLA2EL
1a
6 to 12
20
550
Vcc/2
4.3
0.4
±.0125
3
CSLA2EM
1a
6 to 12
20
765
Vcc/2
3.1
0.3
±.007
3
CSLA2EN
1a
6 to 12
20
950
Vcc/2
2.3
0.2
±.007
3
NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sensor. The capacitor will block
out the effect of the temperature variation of the offset voltage which increases the accuracy of the device.
* N = number of turns
PDFINFO
p a g e - 0 5 8
58
Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
Solid State Sensors
Linear Current Sensors
CS Series
SIDE MOUNT WITH 9SS SENSOR, SOURCE OUTPUT
Sensitivity
Catalog
Listing
Mtg.
Dim.
Fig.
Supply
Volt.
(Volts DC)
Supply
Current
(mA Max.)
Current
(Amps
Peak)
Sensed
Offset
Volt.
(Volts±10%)
Nominal
CSLA1GD
2a
8 to 16
19
57
Vcc/2
49.6
CSLA1GE
2a
8 to 16
19
75
Vcc/2
CSLA1GF
2a
8 to 16
19
100
Vcc/2
mV&N*
At 12 VDC
± TOL
Offset
Shift
(%/°C)
Response
Time
(µ Sec.)
5.8
±.05
3
39.4
4.4
±.05
3
29.7
2.7
±.05
3
Response
Time
(µ Sec.)
SIDE MOUNT WITH SS9 SENSOR, SINK/SOURCE OUTPUT
Sensitivity
mV&N*
At 8 VDC
Catalog
Listing
Mtg.
Dim.
Fig.
Supply
Volt.
(Volts DC)
Supply
Current
(mA Max.)
Sensed
Current
(Amps
Peak)
Offset
Volt.
(Volts±2%)
Nominal
± TOL
Offset
Shift
(%/°C)
CSLA2GD
2a
6 to 12
20
72
Vcc/2
32.7
3.0
±.02
8
CSLA2GE
2a
6 to 12
20
92
Vcc/2
26.1
2.1
±.02
8
CSLA2GF
2a
6 to 12
20
125
Vcc/2
19.6
1.3
±.02
8
CSLA2GG
2a
6 to 12
20
150
Vcc/2
12.7
0.6
±.02
8
NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sensor. The capacitor will block
out the effect of the temperature variation of the offset voltage which increases the accuracy of the device.
*N = number of turns.
MOUNTING DIMENSIONS (for reference only)
Figure 1
Figure 2
PDFINFO
Current
Figure 1a
Figure 2a
* Application consideration: The output is clamped at the high end. Clamping voltage may be as low as 9VDC.
The output will not exceed the clamping voltage regardless of field strength
or supply voltage.
Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
59
p a g e - 0 5 9