OMRON C500

Programmable Terminals
NT11/ NT21
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and
workmanship for a period of one year (or other period if specified) from date of sale by
OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED,
REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR
PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER
OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE
REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL
DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH
THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the
product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER
CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE
MODIFICATION OR REPAIR.
This catalog mainly provides information that is necessary for selecting suitable models, and
does not contain precautions for correct use. Always read the precautions and other
required information provided in product operation manuals before using the product.
The application examples provided in this catalog are for reference only. Check functions
and safety of the equipment before use.
Never use the products for any application requiring special safety requirements, such as
nuclear energy control systems, railroad systems, aviation systems, medical equipment,
amusement machines, vehicles, safety equipment, or other application involving serious risk
to life or property, without ensuring that the system as a whole has been designed to
address the risks, and that the OMRON products are properly rated and installed for the
intended use within the overall equipment or system.
NT11
NT21
Note: Do not use this document to operate the Unit.
OMRON Corporation
Regional Headquarters
FA Systems Division H.Q.
66 Matsumoto
Mishima-city, Shizuoka 411-8511
Japan
Tel: (81)55-977-9181
Fax: (81)55-977-9045
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
Authorized Distributor:
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg, IL 60173
U.S.A.
Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue,
#11-01, UE Square,
Singapore 239920
Tel: (65)6835-3011/Fax: (65)6835-2711
Note: Specifications subject to change without notice.
Cat. No. V071-E1-02
Printed in Japan
1003-0.5M
Compact Size, High Performance
NT11
NT
Superb functionality with a compact screen size
Effective display area
117 x 63 mm
High-speed NT Links
Two RS-232C ports
Memory Link
Printout of Production Status
Bar Graphs can be Displayed
Data such as the production status and production results
can be printed out, leaving a record on paper which can be
used as a daily report.
(The NT11S has a printer port. One screen only is printed.)
Bar graph displays allow the progress of processes to be
checked at a glance.
(The bars are oriented horizontally.)
Supports Memory Units
Up to 3,999 screens
Concentrated functionality
Mathematical
functions
31 functional parts
• Recipes
• Alarm lists/histories
• Image library
• Trend graphs
• Analog meters
NT20S/NT31
data compatibility
Screen
Line 1
Line 2
Line 3
Prod.
200
140
350
Plan
200
150
350
Advantages From
the Standpoint of Maintenance,
Password Screens for Security
Upgraded NT Support Tool
version (-EV4.7)
• Shares I/O comment data
with CX-Programmer
• Symbol Manager previews
• Copy image library window data
• Individual editing of grouped parts
• Windows XP supported
NT21
Supports RS-232C/422
Adapter (connector)
Bar Code Reader
function
Programming Console
function
Integral Numeric Key Pad
The display, numeric keys, and function keys are all
integrated into the front panel, which is convenient for
designers. The key layout is ergonomically designed for
ease of use.
Password screens cannot be accessed unless the correct
password is entered. This means that the operations that
can be performed can be restricted according to the
operator.
High-speed Host Link
Up to 115,200 bps supported between CS1/CJ1 PLCs.
High-speed Host Link
Key Titles can be Marked on the Function
Key Sheet
Long-lived Backlight
Key titles can be marked on the function key sheet in
accordance with the applications of the keys: the sheet can
be taken out from the side face of the terminal.
The front panel of the terminal has a water-withstanding
construction.
Fully Compatible
with NT11S
Full Area Access
to CS1/CJ1
Since LEDs are used for the backlight, it is very long-lived
and rarely needs to be changed.
Display History Record Helps in Analysis of
Machine Faults
When the display history record function is set as a screen
attribute, the time, the screen number, and a comment are
recorded in the terminal's memory every time the relevant
screen is displayed. This display history can be printed by
issuing a print instruction from the host, and is useful for
machine fault analysis.
Example key titles:
F1
F2
RUN
AUT
Long-lived Backlight
F3
MAN.
Example printout
F4
STOP
NT11
Password
Screens
No. Time
Screen No Screen Comment
1 11/01-10:00 1
LINE ERROR
2 11/07-15:33 15 MOTOR ERROR
3 11/11-13:56 19 COMPRESSER ERROR
4 11/14-09:12 5
MOTOR ERROR
Simplified Ladder Programming
Conforms to NEMA4 and IP65
2
3
NT21
NT2
Versatile I/O and Large-capacity
Screen Memory in a Space-saving Size
Highly Reliable Hardware
Upgraded NT Support Tool Version (EV4.7)
Small Size, Large Screen
Long, Maintenance-Free Life (50,000 h)
Enhanced Editing Functions
The LCD screen is larger than the OMRON NT20S
(increased from 256 x 128 dots to 260 x 140 dots), but the
external dimensions and panel cut-out size are the same.
Conforms to International Standards
•I/O comments in the I/O tables of the CX-Programmer can
be used directly.
Larger
screen
The NT21 conforms to the EC Directives, as well as UL,
cULus (Class 1 Div2), and C-Tick.
The front panel has an enclosure rating equivalent to IP65F.
NT Support Tool
CX-Programmer
CX-Server
I/O comment data
System and screen data can be stored in
NT21 Flash Memory.
I/O comments for designated PLC addresses can be
used directly, with no need for CSV file conversion.
Function Support Equivalent to That
of a Mid-size Operator Interface
Two RS-232C Ports
Two RS-232C ports in the NT21 (compared with one in the
NT20S) enable simultaneous connection of a PLC, Bar
Code Reader, and NT Support Tool (connectable to serial
port A only).
NT21
NT Support Tool
(screen creation/transfer)
RS-232C
RS-232C
PLC (host)
Plenty of Capacity for Saving Graphic Screens
With 512 Kbytes of memory
capacity, there is more than
ample space for storing screen
data.
Abundant
graphic screen
storage
Versatile Communications
NT21
NT21
High-speed
1:N NT Links
4
Memory
Link
•Windows XP supported.
Comparison with the NT11
Basic
performance
Alarm List/History(*)
Model
Dimensions
NT11
NT11S
218 x 113 x 38.2 mm (H x W x D)
Resolution
160 x 64 dots (4.24 inches)
100 x 40 mm
Effective display area
Display color
An alarm message can be
displayed in response to
PLC bit status, and the
content and time of the
message can be stored as
an alarm history.
Max. number of
registered screens
250
Screen data capacity
*C500-BAT08 Battery
(sold separately) required.
Other Keys
Display
elements
Programming Console Function
The NT21 is equipped with many of the same functions as
the SYSMAC PLC Programming Console.
Programming Console
function
Special
functions
PLC (host)
32 KB
4
Numeric Keys, Cursor Keys, Function Keys
Personal
computer
(host)
Up to 256 math equations can be stored in the PT
processing table to allow automatic PT processing, and
the results can be written to the numeral memory table or
other destinations. This makes it possible to perform
scaling and other mathematical operations automatically
in the PT.
117 x 63 mm
112 x 56 mm
Black & white (with blue mode)
178.5 x 100.5 mm
3,999
500
512 KB
96 KB
None
None
None
None
None
Supported
None
Painting out
None
Supported
None
Image/library displays
None
256 positions per screen
None
Analog meters
None
50 positions per screen
None
Trend graphs
None
1 position per screen
None
Broken line graphs
None
1 position per screen
None
Alarm lists/histories
None
4 positions per screen
None
Recipes
None
1 position per screen
None
Interlocks
None
Supported
None
Mathematical
Function
None
Math equations: Max. 256
(arithmetic functions,
logic operations,
bit manipulations,
comparison operations)
None
Programming
Console function
None
(Executes functions
equivalent to C200H-PR027
and CS1 Programming
Consoles.)
None
Supported
None
Supported
None
50,000 hours min.
10,000 hours min.
None
Supported
Via RS-232C
communications
None
Supported
None
9,600/19,200
9,600/19,200
High-quality font
Backlight service life
Communications
256 x 128 dots
(4.91 inches)
Rectangles, polygons,
arcs, sectors
RS-232C
Mathematical Functions
260 x 140 dots
(5.2 inches)
204.2 x 99.8 mm
Panel cut-out size (W x H)
Function keys
NT21
NT20S
190 x 110 x 53.5 mm (H x W x D)
Black & white (with Yellow mode)
None
None (Emergency transfer mode)*
Memory Unit
RS-232C
PLC (host)
Note: Some data revisions may be required due to size differences.
Parts tables on the PT
screen can be used to set
multiple word data in
records, which can then
be written to the PLC by a
simple PT touch panel operation. For example, the setting
parameters for separate models can be edited on the PT,
then written to or read from the PLC.
NT21
In addition to the Host Link and 1:1 NT Link
communications, the NT21 supports high-speed 1:N NT
Links and Memory Link communications.
RS-232C
Recipe Function
•Symbol Manager previews
are supported.
This function makes it
possible to preview symbols
(parts created from graphics
data).
•Parts can be copied by drag &
drop operations of image,
library, or mark data.
•The properties of grouped
parts can be edited without
having to ungroup them.
•Because NT20S and NT31
screen data is compatible
with the NT21, existing software assets can be utilized
to greatly reduce the number of design steps.
50,000 hours min.
Memory Links
Bar Code Reader
connection
Host Link Speed
Up to 115,200
10,000 hours min.
9,600/19,200
*Emergency transfer mode: When power to the NT11 is turned ON with DIP switch pin 3 turned ON, data transfer mode can be entered directly without any other operation.
5
NT21
NT2
NT11
NT
NT11 General Specifications
Item
Special Features
Specification
24 VDC
Specification
Printing function
Allowable power
Item
Printing of display history data
Printing of daily reports (printing format registered by the users)
Conforms to IEC61000-4-4, 2K (power lines)
Vibration resistance
10 to 57 Hz with 0.075 mm amplitude and 57 to 150 Hz with
9.8 m/s2 acceleration for 30 min in each of X, Y, and Z directions
Shock resistance
147 m/s 3 times in each of X, Y, and Z directions
Product
Ambient operating
temperature
0 to +50˚C
Ambient operating
humidity
35 to 85% RH (with no condensation)
Terminal*
Specification
Host link direct
connection,
NT link method
Support Software
Operating
environment
No corrosive gasses.
Storage temperature
–20 to +70˚C (with no freezing)
Enclosure ratings
Front panel: Equivalent to IP65, NEMA4
Weight
1.0 kg max.
Shock resistance
NT11 Product Configurations
2
Function key sheet
*
Power consumption
Conforms to IEC61000-4-4. Power supply line: 2 kV
2
Vibration resistance
• Simple communications confirmation.
Model
Ten-key type (frame color: beige)
NT11-SF121-EV1
Ten-key type (frame color: black)
NT11-SF121B-EV1
CD-ROM (for Windows 95, 98,
Me, XP, NT, 2000)
NT-ZJCAT1-EV4
10 sheets for replacement for beige
NT11-CKF01
10 sheets for replacement for black
NT11-CKF01B
Item
Specification
±15%
Noise resistance
Maintenance
functions
Noise resistance
Display Specifications
NT21 General Specifications
Item
acceleration,
Peak acceleration 15 G,
Ambient operating
temperature
˚
Ambient operating
humidity
˚C)
Enclosure ratings
Front panel operating section: Equivalent to IP65F, NEMA 4.*
Weight
0.6 kg max.
*Connecting cables with the PLC and NTST are the same as those for the NT21.
Please refer to the next page.
Display/Panel Specifications
Note: In order to improve the performance of displays, liquid crystal devices may be ch
Item
Dot matrix of STN liquid
Display screen
• Number of dots: 160 x 64
• Effective display area:
100 x 40 mm
• Life expectancy: 50,000 hours
minimum
• View angle (left/right direction):
±20˚
Indicators
• RUN indicator (Green LED): Lit during operation
Switch
• Life expectancy: 1 million operations minimum
203
Graphics
Number of
characters displayed
Display
elements
Numeral
screen
Menu
screen
Can be set to turn OFF in 1 to 255 min or to
remain ON with screen saver
Service life
Specification
Number of switches
91 (13 horizontally x 7 vertically)
Input
Pressure-sensitive
1 N max.
Communications method
Not supported
Host Link
Supported
Supported
1:1 NT Link
Supported
Supported
1:N NT Links
Supported
Supported
NT Link, PT Programming Console function
Supported
Supported
Supported
Supported
Supported
Not supported
Bar Code Reader
Trend graphs
One frame per screen, 50 items per frame
(8 items max. for data logging)
256 positions per screen
Image library images
256 positions per screen
26 positions per screen
Memory Links
*Connection via RS-422A/485 is possible using the NS-AL002 RS-232C/422A Adapter (connector),
which can be connected only to serial port B. (RS-485 connections must use 1:N NT Links.)
NT21 Standard Models
Product
Total of 256 positions
for both numerical and
thumbwheel settings
Specification
Panel Plate thickness: 1.6 to 4.8 mm
Recommended panel cutout:
8 positions per screen
Frame color: beige
NT21-ST121-E
Support Tooll Windows 95, 98, Me, NT, or 2000
CD-ROM
NT-ZJCAT1-EV4
For screen transfer
Cables
Recipes
One position per screen
Normal screens
Displays screens registered as normal
For
PLC
connection
XW2Z-S002
PT: 9-pin
PLC: 9-pin
Cable length: 2 m
XW2Z-200T
PT: 9-pin
PLC: 25-pin
Cable length: 2 m
XW2Z-200S
Cable length: 5 m
XW2Z-500S
Cable length: 5 m
XW2Z-500T-2
PT: 9-pin
PLC: Mini-peripheral
A maximum of eight screens can be displayed overlapping each other.
8 positions per screen
4 positions per screen
Order of frequency, 256 screens
Ensures security: screens for which this attribute is set can
only be displayed if the correct password is input.
204.2 +0.5
0
Screen Windows
Display history screens
types
Programming
Console screen
Emulates PLC Programming Console functions,
capable of being called from RUN mode.
Screen attributes
Four items per screen
Screen types
Normal screen: Displays screen registered as normal.
Max. number of
registered screens
250
Screen registration
method
Transfer screen data created using an IBM PC/AT personal
computer to the PT.
Screen saving
method
Saved to flash memory: 32 KB (downloading method)
Order of occurrence (1,024 screens max.), order of frequency (255 times max.)
Displayed when powering ON (or resetting ) the PT,
and when switching to RUN mode.
Max. number of
Rear face
Up to three window screens can be displayed.
System startup
screen
Number
of
screens Screen number
Screen registration
method
80.5
Saving screen data
Options
Reflection Protective Sheets Display area only (5 sheets)
NT20M-KBA04
Chemical-resistive Cover
Silicon cover
NT20S-KBA01
Battery
For alarm lists/histories
For screen and system
data transfer
C500-BAT08
Memory Unit
Buzzer, display history, normal background colors,
backlight mode, local windows
NT-MF161
RS-232C/422A Adapter
NS-AL002
Connector Kit
XM2S-0911-S003
Dimensions
3,999
0:
No display
1 to 3999: User registered screens
(normal, overlapping, windows)
9000:
System startup screen
9001:
Display history screens, order of occurrence
9002:
Display history screens, order of frequency
9020:
Programming Console screen
9999:
Model number
NT21
Programmable Monochrome STN
Terminal
256 positions per screen
Normal-size: 20 horizontally x 4 lines vertically max.
Serial port B
Supported
50 positions per screen, capable of displaying signs and percentages
Lamps
Serial port A
NT Support Tool
Analog meters
One frame per screen, 256 items per frame,
260 points per item
1 million operations min.
External Interface Specifications
SBC/personal computer
38.2
50,000 hours min. (at room temperature,
until brightness is reduced to 50%)
Replacement Non-replaceable
50 positions per screen, capable of displaying signs and percentages
256 positions per screen
Numeral
settings
Screen
attributes history
50,000 hours min. (until contrast reduced to 50%)
Automatic turn-OFF
Graph displays
218
98.8 +0.5
0
Graph
rectangles, circles,
Touch switches
Normal characters (8 x 16 dots): Alphanumerics and symbols
Marks (8 x 16 dots): User-defined, 64 max.
Service life
256 positions per screen, max.
1,024 display elements for overlapping screens
Display
elements Broken line graphs
˚
Black & white (with blue mode)
Character string
displays
Specification
Double width
Character
string
displays
Touch
panel
PLC
98
˚
Display color
Item
Marks
Display Capacity
Display characters
With overlapping screens,
the total is
524,280 per screen
(Graphics:
Note: In order to improve the performance of displays, liquid crystal devices may be changed
without notice.
Item
Specification
Fixed displays
113
3
117 mm horizontally x 63 mm vertically
Viewing angle
Life expectancy
Item
Backlight
• LED
• Life expectancy: 50,000 hours
minimum
• Automatic turn-off: can be set
to turn off in 10 minutes or
1 hour, or to remain on.
260 dots horizontally x 140 dots vertically
Effective display area
Backlight
(white cold cathode
tube)
Display Capacity
Outside Dimensions
Specification
Number of dots (resolution)
Panel Specifications
190 x 110 x 53.5 mm (W x H x D)
(thickness inside panel: 49.0 mm)
*Usage may not be possible in places where the unit would be exposed to oil for long periods.
and a flash ROM that downloads the system program.
Monochrome STN LCD
˚
–
Dimensions
Display
panel
Specification
Display device
178
100 122
53.5
4.5
Return to previous screen designation
By transferring screen data from the NT Support Tool
to the PT via serial communications
39 min.
110
By mounting the Memory Unit and downloading
(automatic/manual transfer) data to the PT
Flash memory (PT internal image memory)
15.5
28
142
190
Panel thickness: 1.6 to 4.8 mm
178.5 +0.5/– x 100.5
6
/–0 mm (W x H)
19.5
52.5
Cat. No. V071-E1-02
OMRON Corporation
2007. 3
In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.