ALLEGRO UGN3503U

Data Sheet
27501B†
3503
RATIOMETRIC, LINEAR
HALL-EFFECT SENSORS
The UGN3503LT, UGN3503U, and UGN3503UA Hall-effect
sensors accurately track extremely small changes in magnetic flux
density—changes generally too small to operate Hall-effect switches.
X
As motion detectors, gear tooth sensors, and proximity detectors,
they are magnetically driven mirrors of mechanical events. As sensitive
monitors of electromagnets, they can effectively measure a system's
performance with negligible system loading while providing isolation
from contaminated and electrically noisy environments.
Each Hall-effect integrated circuit includes a Hall sensing element,
linear amplifier, and emitter-follower output stage. Problems associated
with handling tiny analog signals are minimized by having the Hall cell
and amplifier on a single chip.
2
3
OUTPUT
1
GROUND
CC
SUPPLY
V
Dwg. PH-006
Pinning is shown viewed from branded side.
Three package styles provide a magnetically optimized package for
most applications. Package suffix ‘LT’ is a miniature SOT-89/TO243AA transistor package for surface-mount applications; suffix ‘U’ is a
miniature three-lead plastic SIP, while ‘UA’ is a three-lead ultra-miniSIP. All devices are rated for continuous operation over the temperature
range of -20°C to +85°C.
FEATURES
■
■
■
■
■
Extremely Sensitive
Flat Response to 23 kHz
Low-Noise Output
4.5 V to 6 V Operation
Magnetically Optimized Package
ABSOLUTE MAXIMUM RATINGS
Supply Voltage, VCC ............................. 8 V
Magnetic Flux Density, B ......... Unlimited
Operating Temperature Range,
TA ............................ -20°C to +85°C
Storage Temperature Range,
TS ........................... -65°C to +150°C
Always order by complete part number, e.g., UGN3503UA .
3503
RATIOMETRIC,
LINEAR
HALL-EFFECT SENSORS
FUNCTIONAL BLOCK DIAGRAM
1 VCC
REG.
X
3
OUTPUT
2
GROUND
Dwg. FH-007
ELECTRICAL CHARACTERISTICS at TA = +25°C, VCC = 5 V
Limits
Characteristic
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Operating Voltage
VCC
4.5
—
6.0
V
Supply Current
ICC
—
9.0
13
mA
Quiescent Output Voltage
VOUT
B=0G
2.25
2.50
2.75
V
Sensitivity
∆VOUT
B = 0 G to ±900 G
0.75
1.30
1.75
mV/G
—
23
—
kHz
—
90
—
µV
—
50
220
Ω
Bandwidth (-3 dB)
BW
Broadband Output Noise
Vout
Output Resistance
ROUT
BW = 10 Hz to 10 kHz
All output-voltage measurements are made with a voltmeter having an input impedance of at least 10 kΩ.
Magnetic flux density is measured at most sensitive area of device located 0.0165" (0.42 mm) below the branded face of the ‘U’
package; 0.0195" (0.50 mm) below the branded face of the ‘UA’ package; and 0.0305" (0.775 mm) below the branded face of the
‘LT’ package.
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
Copyright © 1985, 2002 Allegro MicroSystems, Inc.
3503
RATIOMETRIC,
LINEAR
HALL-EFFECT SENSORS
OUTPUT VOLTAGE AS A
FUNCTION OF TEMPERATURE
OUTPUT NOISE AS A
FUNCTION OF FREQUENCY
4.0
10
OUTPUT NOISE IN µ Vrms √HZ
VCC = 5V
3.5
OUTPUT IN VOLTS
B= +500G
3.0
B = 0G
2.5
2.0
8.0
VCC = +5V
TA = +25°C
6.0
4.0
2.0
B= -500G
0
1.5
40
20
0
+25
+85
10
+125
AMBIENT TEMPERATURE IN C
SUPPLY CURRENT AS A
FUNCTION OF SUPPLY VOLTAGE
1K
10K
Dwg. A-12,505
DEVICE SENSITIVITY AS A
FUNCTION OF SUPPLY VOLTAGE
12
2.5
TYPICAL SENSITIVITY IN V/G
B = 0G
11
TA = +25°C
SUPPLY CURRENT IN mA
100
FREQUENCY IN HZ
Dwg. A-12,573
10
9.0
TA = +25°C
2.0
1.5
1.0
0.5
8.0
7.0
0
4.5
5.0
5.5
SUPPLY VOLTAGE IN VOLTS
6.0
4.5
5.0
5.5
SUPPLY VOLTAGE IN VOLTS
6.0
Dwg. A-12,506
Dwg. A-12,507
OUTPUT NULL VOLTAGE AS A
FUNCTION OF SUPPLY VOLTAGE
LINEARITY AND SYMMETRY AS A
FUNCTION OF SUPPLY VOLTAGE
100
LINEARITY AND SYMMETRY IN PERCENT
5.0
OUTPUT NULL VOLTAGE IN VOLTS
B = 0G
TA = +25°C
4.0
3.0
2.0
1.0
0
OUTPUT SYMMETRY
99
98
W
ITY BELO
LINEAR
G
B = -900
NULL
LL
VE NU
ITY ABO
LINEAR
G
B = +900
97
TA = +25°C
96
95
4.5
5.0
5.5
SUPPLY VOLTAGE IN VOLTS
6.0
Dwg. A-12,508
www.allegromicro.com
4.5
5.0
5.5
SUPPLY VOLTAGE IN VOLTS
6.0
Dwg.A-12,509
3503
RATIOMETRIC,
LINEAR
HALL-EFFECT SENSORS
OPERATION
NOTCH SENSOR
The output null voltage (B = 0 G) is nominally one-half the supply
voltage. A south magnetic pole, presented to the branded face of the Halleffect sensor will drive the output higher than the null voltage level. A north
magnetic pole will drive the output below the null level.
In operation, instantaneous and proportional output-voltage levels are
dependent on magnetic flux density at the most sensitive area of the device.
Greatest sensitivity is obtained with a supply voltage of 6 V, but at the cost of
increased supply current and a slight loss of output symmetry. The sensor's
output is usually capacitively coupled to an amplifier that boosts the output
above the millivolt level.
In two applications shown, a permanent bias magnet is attached with
epoxy glue to the back of the epoxy package. The presence of ferrous material
at the face of the package acts as a flux concentrator.
Dwg. A-12,574
GEAR TOOTH SENSOR
The south pole of a magnet is attached to the back of the package if the
Hall-effect IC is to sense the presence of ferrous material. The north pole of a
magnet is attached to the back surface if the integrated circuit is to sense the
absence of ferrous matrial.
Calibrated linear Hall devices, which can be used to determine the actual
flux density presented to the sensor in a particular application, are available.
SENSOR LOCATIONS
N
SUFFIX “U”
ACTIVE AREA DEPTH
0.0165"
0.42 mm
0.093"
2.37 mm
NOM
0.072"
1.83 mm
3 2
1
Dwg. A-12,512
A
CURRENT MONITOR
BRANDED
SURFACE
1
2
3
Dwg. MH-002-5D
SUFFIX “LT”
ACTIVE AREA DEPTH
0.0305"
0.775 mm
NOM
SUFFIX “UA”
ACTIVE AREA DEPTH
0.0195"
0.50 mm
NOM
0.091"
2.32 mm
0.084"
2.13 mm
0.042"
1.08 mm
0.056"
1.43 mm
A
A
1
2
3
BRANDED
SURFACE
1
2
3
Dwg. A-12,513
Dwg. MH-008-9A
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
Dwg. MH-011-3D
3503
RATIOMETRIC,
LINEAR
HALL-EFFECT SENSORS
UGN3503LT
(SOT89/TO-243AA)
Dimensions in Inches
(for reference only)
0.181
0.173
0.072
0.064
0.167
0.155
2
1
Dimensions in Millimeters
(controlling dimensions)
0.063
0.055
3
0.102
0.090
0.0173
0.0138
0.090
0.084
4.25
3.94
0.0189
0.0142
0.0221
0.0173
0.047
0.035
0.059
BSC
4.60
4.40
1.83
1.62
1
BSC
3.00
BSC
Dwg. MA-009-3A in
Dwg. MA-009-3A mm
2.5
2.0
B
0.031
0.102
A
0.8
2.6
A
4.6
0.181
1
2
2.29
2.13
0.56
0.44
1.50
0.098
0.079
B
2.60
2.29
3
0.44
0.35
0.48
0.36
1.20
0.89
0.118
BSC
2
1.60
1.40
3 0.047
1
2
3
1.2
0.028
0.031
0.7
0.8
TYP
TYP
TYP
TYP
Pads 1, 2, 3, and A — Standard SOT89 Layout
Pads 1, 2, 3, and B — Low-Stress Version
Pads 1, 2, and 3 only — Lowest Stress, But Not Self Aligning
Pads 1, 2, 3, and A — Standard SOT89 Layout
Pads 1, 2, 3, and B — Low-Stress Version
Pads 1, 2, and 3 only — Lowest Stress, But Not Self Aligning
Dwg. MA-012-3 in
Dwg. MA-012-3 mm
NOTES: 1. Exact body and lead configuration at vendor’s option within limits shown.
2. Supplied in bulk pack (500 pieces per bag) or add "TR" to part number for tape and reel.
3. Only low-temperature (≤240°C) reflow-soldering techniques are recommended for SOT89 devices.
www.allegromicro.com
3503
RATIOMETRIC,
LINEAR
HALL-EFFECT SENSORS
UGN3503U
Dimensions in Inches
(controlling dimensions)
Dimensions in Millimeters
(for reference only)
0.183
0.178
4.65
4.52
1.60
1.50
0.063
0.059
4.60
4.47
0.181
0.176
45°
45°
0.086
1
2
0.018
3
2.18
1
2
0.46
3
MAX
MAX
0.0173
0.0138
0.600
0.560
0.44
0.35
15.24
14.23
0.48
0.36
0.0189
0.0142
SEE NOTE
SEE NOTE
1.27
0.050
0.100
2.54
Dwg. MH-003E in
Dwg. MH-003E mm
Devices in the ‘U’ package are
NOT RECOMMENDED FOR NEW DESIGN
NOTES: 1. Tolerances on package height and width represent allowable mold offsets.
Dimensions given are measured at the widest point (parting line).
2. Exact body and lead configuration at vendor’s option within limits shown.
3. Height does not include mold gate flash.
4. Recommended minimum PWB hole diameter to clear transition area is 0.035" (0.89 mm).
5. Minimum lead length was 0.500" (12.70 mm). If existing product to the original specifications is not acceptable,
contact sales office before ordering.
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
3503
RATIOMETRIC,
LINEAR
HALL-EFFECT SENSORS
UGN3503UA
Dimensions in Millimeters
(for reference only)
Dimensions in Inches
(controlling dimensions)
0.164
0.159
4.17
4.04
0.062
0.058
45°
1.57
1.47
45°
0.122
0.117
3.10
2.97
45°
45°
0.085
1
2
3
0.031
2.16
1
2
0.79
3
MAX
MAX
0.640
0.600
16.26
15.24
0.0173
0.0138
0.0189
0.0142
SEE NOTE
0.44
0.35
0.48
0.36
SEE NOTE
1.27
0.050
BSC
BSC
Dwg. MH-014E in
Dwg. MH-014E mm
Radial Lead Form (order UGN3503UA-LC)
NOTES: 1. Tolerances on package height and width represent
allowable mold offsets. Dimensions given are
measured at the widest point (parting line).
2. Exact body and lead configuration at vendor’s option
within limits shown.
3. Height does not include mold gate flash.
4. Recommended minimum PWB hole diameter to clear
transition area is 0.035" (0.89 mm).
5. Where no tolerance is specified, dimension is nominal.
6. Supplied in bulk pack (500 pieces per bag).
1
2
3
0.108"
(2.74 mm)
0.620"
0.500"
(15.7 mm
12.7 mm)
0.100"
(2.5 mm)
Dwg. MH-026
NOTE: Lead-form dimensions are the nominals produced on the
forming equipment. No dimensional tolerance is implied or
guaranteed for bulk packaging (500 pieces per bag).
www.allegromicro.com
3503
RATIOMETRIC,
LINEAR
HALL-EFFECT SENSORS
Allegro MicroSystems, Inc. reserves the right to make, from time to
time, such departures from the detail specifications as may be
required to permit improvements in the design of its products.
The information included herein is believed to be accurate and
reliable. However, Allegro MicroSystems, Inc. assumes no responsibility for its use; nor for any infringements of patents or other rights of
third parties which may result from its use.
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000