DALLAS DS1812-5

DS1812
5V EconoReset with Active
High Push-Pull Output
www.dalsemi.com
FEATURES
PIN ASSIGNMENT
Automatically restarts a microprocessor after
power failure
Maintains reset for 150 ms after VCC returns
to an in-tolerance condition
Reduces need for discrete components
Precision temperature-compensated voltage
reference and voltage sensor
Low-cost TO-92, or space saving surface
mount SOT-23 packages available
Push-pull active high output
Operating temperature -40°C to +85°C
3
1
2
SOT-23 PACKAGE
See Mech. Drawing
1 2 3
1 2 3
TO-92 PACKAGE
See Mech.
Drawings
PIN DESCRIPTION
TO-92
1
2
3
RST
VCC
GND
Active High Reset Output
Power Supply
Ground
SOT-23
1
2
3
RST
VCC
GND
Active High Reset Output
Power Supply
Ground
DESCRIPTION
The DS1812 EconoReset uses a precision temperature reference and comparator circuit to monitor the
status of the power supply (VCC). When an out-of-tolerance condition is detected, an internal power-fail
signal is generated which forces reset to the active state. When VCC returns to an in-tolerance condition,
the reset signal is kept in the active state for approximately 150 ms to allow the power supply and
processor to stabilize.
1 of 5
111999
DS1812
OPERATION - POWER MONITOR
The DS1812 provides the function of detecting out-of-tolerance power supply conditions and warning a
processor-based system of impending power failure. When VCC is detected as out-of-tolerance, the RST
signal is asserted. On power-up, RST is kept active for approximately 150 ms after the power supply has
reached the selected tolerance. This allows the power supply and microprocessor to stabilize before RST
is released.
BLOCK DIAGRAM (CMOS OUTPUT) Figure 1
APPLICATION EXAMPLE Figure 2
2 of 5
DS1812
TIMING DIAGRAM: POWER-UP Figure 3
TIMING DIAGRAM: POWER-DOWN Figure 4
3 of 5
DS1812
ABSOLUTE MAXIMUM RATINGS*
Voltage on VCC Pin Relative to Ground
Voltage on RST Relative to Ground
Operating Temperature
Storage Temperature
Soldering Temperature
*
-0.5V to +7.0V
-0.5V to VCC +0.5V
-40°C to +85°C
-55°C to +125°C
260°C for 10 seconds
This is a stress rating only and functional operation of the device at these or any other conditions
above those indicated in the operation sections of this specification is not implied. Exposure to
absolute maximum rating conditions for extended periods of time may affect reliability.
RECOMMENDED DC OPERATING CONDITIONS
PARAMETER
SYMBOL
MIN
Supply Voltage
VCC
0.0
DC ELECTRICAL CHARACTERISTICS
PARAMETER
SYMBOL
Output Voltage @ 0-500 µA
VOH
Output Current @ 2.4 volts
IOH
Output Current @ 0.4 volts
IOL
Operating Current VCC < 5.5
ICC
VCC Trip Point (DS1812-5)
VCCTP
VCC Trip Point (DS1812-10)
(-40°C to +85°C)
TYP
MAX
UNITS
NOTES
5.5
V
1
(-40°C to +85°C; VCC=1.2V to 5.5V)
MIN
VCC
-0.5V
TYP
VCC
-0.1V
MAX
350
+10
UNITS
V
NOTES
1
µA
2
mA
2
30
40
µA
3
4.50
4.62
4.75
V
1
VCCTP
4.25
4.35
4.49
V
1
VCC Trip Point (DS1812-15)
VCCTP
4.00
4.13
4.24
V
1
Output Capacitance
COUT
10
pF
AC ELECTRICAL CHARACTERISTICS
PARAMETER
RESET Active Time
VCC Detect to RST
SYMBOL
tRST
(-40°C to +85°C; VCC=1.2V to 5.5V)
MIN
100
tRPD
TYP
150
MAX
300
UNITS
ms
2
5
µs
VCC Slew Rate
(VCCTP (MAX) to VCCTP (MIN))
tF
300
µs
VCC Slew Rate
(VCCTP (MIN) to VCCTP (MAX))
tR
0
ns
tRPU
100
VCC Detect to RST
4 of 5
150
300
ms
NOTES
4
DS1812
NOTES:
1. All voltages are referenced to ground.
2. Measured with VCC ≥ 2.7 volts.
3. Measured with RST output open.
4. tR = 5 µs.
PART MARKING CODES
SOT-23 PACKAGE
“A”, “B”, &“C” represent the device type.
810
DS1810
811
DS1811
812
DS1812
813
DS1813
815
DS1815
816
DS1816
817
DS1817
818
DS1818
“D” represents the device tolerance.
A
5%
B
10%
C
15%
D
20%
5 of 5