ELPIDA EDE5116AFSE

DATA SHEET
512M bits DDR2 SDRAM
EDE5116AFSE (32M words × 16 bits)
Description
Features
The EDE5116AFSE is a 512M bits DDR2 SDRAM
organized as 8,388,608 words × 16 bits × 4 banks.
It is packaged in 84-ball FBGA (µBGA) package.
• Power supply: VDD, VDDQ = 1.8V ± 0.1V
• Double-data-rate architecture: two data transfers per
clock cycle
• Bi-directional, differential data strobe (DQS and
/DQS) is transmitted/received with data, to be used in
capturing data at the receiver
• DQS is edge aligned with data for READs: centeraligned with data for WRITEs
• Differential clock inputs (CK and /CK)
• DLL aligns DQ and DQS transitions with CK
transitions
• Commands entered on each positive CK edge: data
and data mask referenced to both edges of DQS
• Four internal banks for concurrent operation
• Data mask (DM) for write data
• Burst lengths: 4, 8
• /CAS Latency (CL): 3, 4, 5
• Auto precharge operation for each burst access
• Auto refresh and self refresh modes
• Average refresh period
 7.8µs at 0°C ≤ TC ≤ +85°C
 3.9µs at +85°C < TC ≤ +95°C
• SSTL_18 compatible I/O
• Posted CAS by programmable additive latency for
better command and data bus efficiency
• Off-Chip-Driver Impedance Adjustment and On-DieTermination for better signal quality
• /DQS can be disabled for single-ended Data Strobe
operation.
• FBGA (µBGA) package with lead free solder
(Sn-Ag-Cu)
 RoHS compliant
Document No. E0705E20 (Ver. 2.0)
Date Published July 2005 (K) Japan
Printed in Japan
URL: http://www.elpida.com
Elpida Memory, Inc. 2005
EDE5116AFSE
Ordering Information
Part number
EDE5116AFSE-6E-E
EDE5116AFSE-5C-E
EDE5116AFSE-4A-E
Mask
version
F
Organization
(words × bits)
32M × 16
Internal
Banks
Speed bin
(CL-tRCD-tRP)
4
DDR2-667 (5-5-5)
DDR2-533 (4-4-4)
DDR2-400 (3-3-3)
Package
84-ball FBGA (µBGA)
Part Number
E D E 51 16 A F SE - 6E - E
Elpida Memory
Type
D: Monolithic Device
Environment code
E: Lead Free
Product Family
E: DDR2
Speed
6E: DDR2-667 (5-5-5)
5C: DDR2-533 (4-4-4)
4A: DDR2-400 (3-3-3)
Density / Bank
51: 512Mb /4-bank
Organization
16: x16
Package
SE: FBGA (µBGA with back cover)
Power Supply, Interface
A: 1.8V, SSTL_18
Die Rev.
Data Sheet E0705E20 (Ver. 2.0)
2
EDE5116AFSE
Pin Configurations
/xxx indicates active low signal.
84-ball FBGA (µBGA)
1
2
3
VDD
NC
VSS
VSSQ /UDQS VDDQ
DQ14 VSSQ UDM
UDQS VSSQ DQ15
VDDQ
VDDQ
7
8
9
A
B
C
D
DQ9 VDDQ
DQ8
VDDQ
DQ12 VSSQ DQ11
DQ10 VSSQ DQ13
VDD
NC
VSS
VSSQ /LDQS VDDQ
DQ6
VSSQ
LDM
LDQS VSSQ
E
F
DQ7
G
VDDQ
DQ1 VDDQ
VDDQ
DQ0
VDDQ
H
DQ4
VSSQ
DQ3
DQ2
VSSQ
DQ5
VDDL VREF
VSS
VSSDL
CK
VDD
CKE
/WE
/RAS
/CK
ODT
BA0
BA1
/CAS
/CS
A10
A1
A2
A0
A3
A5
A6
A4
A7
A9
A11
A8
A12
NC
NC
NC
J
K
L
NC
M
VDD
N
VSS
P
VSS
R
VDD
(Top view)
Pin name
Function
Pin name
Function
A0 to A12
Address inputs
VDD
Supply voltage for internal circuit
BA0, BA1
Bank select
VSS
Ground for internal circuit
DQ0 to DQ15
Data input/output
VDDQ
Supply voltage for DQ circuit
UDQS, /UDQS
LDQS, /LDQS
Differential data strobe
VSSQ
Ground for DQ circuit
/CS
Chip select
VREF
Input reference voltage
/RAS, /CAS, /WE
Command input
VDDL
Supply voltage for DLL circuit
CKE
Clock enable
VSSDL
Ground for DLL circuit
CK, /CK
Differential clock input
NC*
1
UDM, LDM
Write data mask
NU*
2
ODT
ODT control
Notes: 1. Not internally connected with die.
2. Don’t use other than reserved functions.
Data Sheet E0705E20 (Ver. 2.0)
3
No connection
Not usable
EDE5116AFSE
CONTENTS
Description.....................................................................................................................................................1
Features.........................................................................................................................................................1
Ordering Information......................................................................................................................................2
Part Number ..................................................................................................................................................2
Pin Configurations .........................................................................................................................................3
Electrical Specifications.................................................................................................................................5
Block Diagram .............................................................................................................................................15
Pin Function.................................................................................................................................................16
Command Operation ...................................................................................................................................18
Simplified State Diagram .............................................................................................................................25
Operation of DDR2 SDRAM ........................................................................................................................26
Package Drawing ........................................................................................................................................62
Recommended Soldering Conditions..........................................................................................................63
Data Sheet E0705E20 (Ver. 2.0)
4
EDE5116AFSE
Electrical Specifications
• All voltages are referenced to VSS (GND)
• Execute power-up and Initialization sequence before proper device operation is achieved.
Absolute Maximum Ratings
Parameter
Symbol
Rating
Unit
Notes
Power supply voltage
VDD
−1.0 to +2.3
V
1
Power supply voltage for output
VDDQ
−0.5 to +2.3
V
1
Input voltage
VIN
−0.5 to +2.3
V
1
Output voltage
VOUT
−0.5 to +2.3
V
1
Storage temperature
Tstg
−55 to +100
°C
1, 2
Power dissipation
PD
1.0
W
1
Short circuit output current
IOUT
50
mA
1
Notes: 1. Stresses greater than those listed under Absolute Maximum Ratings may cause permanent damage to
the device. This is a stress rating only and functional operation of the device at these or any other
conditions above those indicated in the operational sections of this specification is not implied. Exposure
to absolute maximum rating conditions for extended periods may affect reliability.
2. Storage temperature is the case surface temperature on the center/top side of the DRAM.
Caution
Exposing the device to stress above those listed in Absolute Maximum Ratings could cause
permanent damage. The device is not meant to be operated under conditions outside the limits
described in the operational section of this specification. Exposure to Absolute Maximum Rating
conditions for extended periods may affect device reliability.
Operating Temperature Condition
Parameter
Symbol
Rating
Unit
Notes
Operating case temperature
TC
0 to +95
°C
1, 2
Notes: 1. Operating temperature is the case surface temperature on the center/top side of the DRAM.
2. Supporting 0°C to +85°C with full AC and DC specifications.
Supporting 0°C to +85°C and being able to extend to +95°C with doubling auto-refresh commands in
frequency to a 32ms period (tREFI = 3.9µs) and higher temperature Self-Refresh entry via A7 "1" on
EMRS (2).
Data Sheet E0705E20 (Ver. 2.0)
5
EDE5116AFSE
Recommended DC Operating Conditions (SSTL_18)
Parameter
Symbol
min.
typ.
max.
Unit
Notes
Supply voltage
VDD
1.7
1.8
1.9
V
4
Supply voltage for output
VDDQ
1.7
1.8
1.9
V
4
Input reference voltage
VREF
0.49 × VDDQ
0.50 × VDDQ 0.51 × VDDQ
V
1, 2
Termination voltage
VTT
VREF − 0.04
VREF
VREF + 0.04
V
3
DC input logic high
VIH (DC)
VREF + 0.125

VDDQ + 0.3
V
DC input low
VIL (DC)
−0.3

VREF – 0.125
V
AC input logic high
-6E
VIH (AC)
VREF + 0.200


V
-5C, -4A
VIH (AC)
VREF + 0.250


V
AC input low
-6E
VIL (AC)


VREF − 0.200
V
-5C, -4A
VIL (AC)


VREF − 0.250
V
Notes: 1. The value of VREF may be selected by the user to provide optimum noise margin in the system. Typically
the value of VREF is expected to be about 0.5 × VDDQ of the transmitting device and VREF are expected
to track variations in VDDQ.
2. Peak to peak AC noise on VREF may not exceed ±2% VREF (DC).
3. VTT of transmitting device must track VREF of receiving device.
4. VDDQ tracks with VDD, VDDL tracks with VDD. AC parameters are measured with VDD, VDDQ and
VDDL tied together.
Data Sheet E0705E20 (Ver. 2.0)
6
EDE5116AFSE
DC Characteristics 1 (TC = 0°C to +85°C, VDD, VDDQ = 1.8V ± 0.1V)
Parameter
Symbol
Grade
max.
Unit
Operating current
(ACT-PRE)
IDD0
-6E
-5C
-4A
120
110
105
mA
Operating current
(ACT-READ-PRE)
IDD1
-6E
-5C
-4A
140
130
125
mA
Precharge power-down
IDD2P
standby current
-6E
-5C
-4A
10
10
8
mA
Precharge quiet
standby current
IDD2Q
-6E
-5C
-4A
30
25
20
mA
Idle standby current
IDD2N
-6E
-5C
-4A
35
30
25
mA
IDD3P-F
-6E
-5C
-4A
35
30
30
mA
IDD3P-S
-6E
-5C
-4A
20
20
20
mA
Active power-down
standby current
Active standby current
IDD3N
-6E
-5C
-4A
60
50
50
mA
Operating current
(Burst read operating)
IDD4R
-6E
-5C
-4A
230
195
160
mA
Operating current
(Burst write operating)
IDD4W
-6E
-5C
-4A
230
195
160
mA
Data Sheet E0705E20 (Ver. 2.0)
7
Test condition
one bank; tCK = tCK (IDD), tRC = tRC (IDD),
tRAS = tRAS min.(IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
one bank; IOUT = 0mA;
BL = 4, CL = CL(IDD), AL = 0;
tCK = tCK (IDD), tRC = tRC (IDD),
tRAS = tRAS min.(IDD); tRCD = tRCD (IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data pattern is same as IDD4W
all banks idle;
tCK = tCK (IDD);
CKE is L;
Other control and address bus inputs are STABLE;
Data bus inputs are FLOATING
all banks idle;
tCK = tCK (IDD);
CKE is H, /CS is H;
Other control and address bus inputs are STABLE;
Data bus inputs are FLOATING
all banks idle;
tCK = tCK (IDD);
CKE is H, /CS is H;
Other control and address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
all banks open;
tCK = tCK (IDD);
CKE is L;
Other control and
address bus inputs are
STABLE;
Data bus inputs are
FLOATING
Fast PDN Exit
MRS(12) = 0
Slow PDN Exit
MRS(12) = 1
all banks open;
tCK = tCK (IDD), tRAS = tRAS max.(IDD),
tRP = tRP (IDD);
CKE is H, /CS is H between valid commands;
Other control and address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
all banks open, continuous burst reads, IOUT = 0mA;
BL = 4, CL = CL(IDD), AL = 0;
tCK = tCK (IDD),
tRAS = tRAS max.(IDD), tRP = tRP (IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data pattern is same as IDD4W
all banks open, continuous burst writes;
BL = 4, CL = CL(IDD), AL = 0;
tCK = tCK (IDD),
tRAS = tRAS max.(IDD), tRP = tRP (IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
EDE5116AFSE
Parameter
Symbol
Grade
max.
Auto-refresh current
IDD5
-6E
-5C
-4A
270
250
230
mA
Self-refresh current
IDD6
6
mA
475
390
315
mA
-6E
-5C
-4A
Operating current (Bank
IDD7
interleaving)
Unit
Test condition
tCK = tCK (IDD);
Refresh command at every tRFC (IDD) interval;
CKE is H, /CS is H between valid commands;
Other control and address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
Self Refresh Mode;
CK and /CK at 0V;
CKE ≤ 0.2V;
Other control and address bus inputs are FLOATING;
Data bus inputs are FLOATING
all bank interleaving reads, IOUT = 0mA;
BL = 4, CL = CL(IDD),
AL = tRCD (IDD) −1 × tCK (IDD);
tCK = tCK (IDD), tRC = tRC (IDD), tRRD = tRRD(IDD),
tRCD = 1 × tCK (IDD);
CKE is H, CS is H between valid commands;
Address bus inputs are STABLE during DESELECTs;
Data pattern is same as IDD4W;
Notes: 1.
2.
3.
4.
IDD specifications are tested after the device is properly initialized.
Input slew rate is specified by AC Input Test Condition.
IDD parameters are specified with ODT disabled.
Data bus consists of DQ, UDM, LDM, UDQS, LDQS, /UDQS and /LDQS. IDD values must be met with all
combinations of EMRS bits 10 and 11.
5. Definitions for IDD
L is defined as VIN ≤ VIL (AC) (max.)
H is defined as VIN ≥ VIH (AC) (min.)
STABLE is defined as inputs stable at an H or L level
FLOATING is defined as inputs at VREF = VDDQ/2
SWITCHING is defined as:
inputs changing between H and L every other clock cycle (once per two clocks) for address and control
signals, and inputs changing between H and L every other data transfer (once per clock) for DQ signals
not including masks or strobes.
6. Refer to AC Timing for IDD Test Conditions.
AC Timing for IDD Test Conditions
For purposes of IDD testing, the following parameters are to be utilized.
DDR2-667
DDR2-533
DDR2-400
Parameter
5-5-5
4-4-4
3-3-3
Unit
CL (IDD)
5
4
3
tCK
tRCD (IDD)
15
15
15
ns
tRC (IDD)
60
60
55
ns
tRRD (IDD)
10
10
10
ns
tCK (IDD)
3
3.75
5
ns
tRAS (min.) (IDD)
45
45
40
ns
tRAS (max.) (IDD)
70000
70000
70000
ns
tRP (IDD)
15
15
15
ns
tRFC (IDD)
105
105
105
ns
Data Sheet E0705E20 (Ver. 2.0)
8
EDE5116AFSE
DC Characteristics 2 (TC = 0°C to +85°C, VDD, VDDQ = 1.8V ± 0.1V)
Parameter
Symbol
Value
Input leakage current
ILI
2
µA
VDD ≥ VIN ≥ VSS
Output leakage current
ILO
5
µA
VDDQ ≥ VOUT ≥ VSS
VTT + 0.603
V
5
VTT − 0.603
V
5
Output timing measurement reference level VOTR
0.5 × VDDQ
V
1
Output minimum sink DC current
IOL
+13.4
mA
3, 4, 5
Output minimum source DC current
IOH
−13.4
mA
2, 4, 5
Minimum required output pull-up under AC
VOH
test load
Maximum required output pull-down under
VOL
AC test load
Notes: 1.
2.
3.
4.
5.
Unit
Notes
The VDDQ of the device under test is referenced.
VDDQ = 1.7V; VOUT = 1.42V.
VDDQ = 1.7V; VOUT = 0.28V.
The DC value of VREF applied to the receiving device is expected to be set to VTT.
After OCD calibration to 18Ω at TC = 25°C, VDD = VDDQ = 1.8V.
DC Characteristics 3 (TC = 0°C to +85°C, VDD, VDDQ = 1.8V ± 0.1V)
Parameter
Symbol
min.
max.
Unit
Notes
AC differential input voltage
VID (AC)
0.5
VDDQ + 0.6
V
1, 2
AC differential cross point voltage
VIX (AC)
0.5 × VDDQ − 0.175
0.5 × VDDQ + 0.175
V
2
AC differential cross point voltage
VOX (AC)
0.5 × VDDQ − 0.125
0.5 × VDDQ + 0.125
V
3
Notes: 1. VID(AC) specifies the input differential voltage |VTR -VCP| required for switching, where VTR is the true
input signal (such as CK, UDQS or LDQS) and VCP is the complementary input signal (such as /CK,
/UDQS or /LDQS). The minimum value is equal to VIH (AC) − VIL(AC).
2. The typical value of VIX(AC) is expected to be about 0.5 × VDDQ of the transmitting device and VIX(AC)
is expected to track variations in VDDQ . VIX(AC) indicates the voltage at which differential input signals
must cross.
3. The typical value of VOX(AC) is expected to be about 0.5 × VDDQ of the transmitting device and
VOX(AC) is expected to track variations in VDDQ . VOX(AC) indicates the voltage at which differential
output signals must cross.
VDDQ
VTR
Crossing point
VID
VIX or VOX
VCP
VSSQ
Differential Signal Levels*1, 2
Data Sheet E0705E20 (Ver. 2.0)
9
EDE5116AFSE
ODT DC Electrical Characteristics (TC = 0°C to +85°C, VDD, VDDQ = 1.8V ± 0.1V)
Parameter
Symbol
min
typ
max
Unit
Note
Rtt effective impedance value for EMRS (A6, A2) = 0, 1; 75 Ω
Rtt1(eff)
60
75
90
Ω
1
Rtt effective impedance value for EMRS (A6, A2) = 1, 0; 150 Ω
Rtt2(eff)
120
150
180
Ω
1
Rtt effective impedance value for EMRS (A6, A2) = 1, 1; 50 Ω
Rtt3(eff)
40
50
60
Ω
1
Deviation of VM with respect to VDDQ/2
∆VM
−6

+6
%
1
Note: 1. Test condition for Rtt measurements.
Measurement Definition for Rtt(eff)
Apply VIH (AC) and VIL (AC) to test pin separately, then measure current I(VIH(AC)) and I(VIL(AC)) respectively.
VIH(AC), and VDDQ values defined in SSTL_18.
Rtt(eff) =
VIH(AC) − VIL(AC)
I(VIH(AC)) − I(VIL(AC))
Measurement Definition for ∆VM
Measure voltage (VM) at test pin (midpoint) with no load.
∆VM =
2 × VM
VDDQ
− 1 × 100%
OCD Default Characteristics (TC = 0°C to +85°C, VDD, VDDQ = 1.8V ± 0.1V)
Parameter
min
typ
max
Unit
Notes
Output impedance
12.6
18
23.4
Ω
1
Pull-up and pull-down mismatch
0

4
Ω
1, 2
Output slew rate
1.5

5
V/ns
3, 4
Notes: 1. Impedance measurement condition for output source DC current: VDDQ = 1.7V; VOUT = 1420mV;
(VOUT−VDDQ)/IOH must be less than 23.4Ω for values of VOUT between VDDQ and VDDQ−280mV.
Impedance measurement condition for output sink DC current: VDDQ = 1.7V; VOUT = 280mV;
VOUT/IOL must be less than 23.4Ω for values of VOUT between 0V and 280mV.
2. Mismatch is absolute value between pull up and pull down, both are measured at same temperature and
voltage.
3. Slew rate measured from VIL(AC) to VIH(AC).
4. The absolute value of the slew rate as measured from DC to DC is equal to or greater than the slew rate
as measured from AC to AC. This is guaranteed by design and characterization.
Data Sheet E0705E20 (Ver. 2.0)
10
EDE5116AFSE
Pin Capacitance (TA = 25°C, VDD, VDDQ = 1.8V ± 0.1V)
Parameter
Symbol
Pins
min.
max.
Unit
Notes
CLK input pin capacitance
CCK
CK, /CK
1.0
2.0
pF
1
1.0
2.0
pF
1
2.5
3.5
pF
2
2.5
4.0
pF
2
Input pin capacitance
CIN
Input/output pin capacitance
-6E
CI/O
-5C, -4A
/RAS, /CAS,
/WE, /CS,
CKE, ODT,
Address
DQ, UDQS, /UDQS,
LDQS, /LDQS,
UDM, LDM
Notes: 1. Matching within 0.25pF.
2. Matching within 0.50pF.
Data Sheet E0705E20 (Ver. 2.0)
11
EDE5116AFSE
AC Characteristics (TC = 0°C to +85°C, VDD, VDDQ = 1.8V ± 0.1V, VSS, VSSQ = 0V)
Frequency (Mbps)
-6E
-5C
-4A
667
533
400
Parameter
Symbol
min.
max.
min.
max.
min.
max.
Unit
/CAS latency
CL
5
5
4
5
3
5
tCK
Active to read or write command
delay
tRCD
15

15

15

ns
Precharge command period
tRP
15

15

15

ns
Active to active/auto refresh
command time
tRC
60

60

55

ns
Notes
−450
+450
−500
+500
−600
+600
ps
DQS output access time from CK,
/CK
tDQSCK −400
+400
−450
+450
−500
+500
ps
CK high-level width
tCH
0.45
0.55
0.45
0.55
0.45
0.55
tCK
CK low-level width
tCL
0.45
0.55
0.45
0.55
0.45
0.55
tCK
CK half period
tHP
min.

(tCL, tCH)
min.

(tCL, tCH)
min.

(tCL, tCH)
ps
Clock cycle time
tCK
3000
8000
3750
8000
5000
8000
ps
DQ and DM input hold time
tDH
175

225

275

ps
5
DQ and DM input setup time
tDS
100

100

150

ps
4
tIPW
0.6

0.6

0.6

tCK
tDIPW
0.35

0.35

0.35

tCK
tHZ

tAC max.

tAC max.

tAC max.
ps
tLZ
tAC min.
tAC max.
tAC min.
tAC max.
tAC min.
tAC max.
ps
tDQSQ

240

300

350
ps
tQHS

340

400

450
ps

tHP –
tQHS

tHP –
tQHS

ps
DQ output access time from CK, /CK tAC
Control and Address input pulse
width for each input
DQ and DM input pulse width for
each input
Data-out high-impedance time from
CK,/CK
Data-out low-impedance time from
CK,/CK
DQS-DQ skew for DQS and
associated DQ signals
DQ hold skew factor
DQ/DQS output hold time from DQS tQH
tHP –
tQHS
Write command to first DQS latching
tDQSS
transition
WL − 0.25 WL + 0.25 WL − 0.25 WL + 0.25 WL − 0.25 WL + 0.25 tCK
DQS input high pulse width
tDQSH
0.35

0.35

0.35

tCK
DQS input low pulse width
tDQSL
0.35

0.35

0.35

tCK
DQS falling edge to CK setup time
tDSS
0.2

0.2

0.2

tCK
DQS falling edge hold time from CK tDSH
0.2

0.2

0.2

tCK
Mode register set command cycle
time
tMRD
2

2

2

tCK
Write postamble
tWPST
0.4
0.6
0.4
0.6
0.4
0.6
tCK
Write preamble
tWPRE
0.35

0.35

0.35

tCK
Address and control input hold time
tIH
275

375

475

ps
5
4
Address and control input setup time tIS
200

250

350

ps
Read preamble
tRPRE
0.9
1.1
0.9
1.1
0.9
1.1
tCK
Read postamble
tRPST
0.4
0.6
0.4
0.6
0.4
0.6
tCK
Active to precharge command
tRAS
45
70000
45
70000
40
70000
ns
Active to auto-precharge delay
tRAP
tRCD min. 
tRCD min. 
Data Sheet E0705E20 (Ver. 2.0)
12
tRCD min. 
ns
EDE5116AFSE
Frequency (Mbps)
-6E
-5C
-4A
667
533
400
Parameter
Symbol
min.
max.
min.
max.
min.
max.
Unit
Active bank A to active bank B
command period
tRRD
10

10

10

ns
Write recovery time
tWR
15

15

15

ns
tDAL
(tWR/tCK)+
(tRP/tCK)

(tWR/tCK)+

(tRP/tCK)
tWTR
7.5

7.5

10

ns
tRTP
7.5

7.5

7.5

ns
tXSNR
tRFC + 10

tRFC + 10

tRFC + 10

ns
tXSRD
200

200

200

tCK
tXP
2

2

2

tCK
tXARD
2

2

2

tCK
3
tXARDS 7− AL

6 − AL

6 − AL

tCK
2, 3
tCKE
3

3

3

tCK
tOIT
0
12
0
12
0
12
ns
tRFC
105

105

105

ns
tREFI

7.8

7.8

7.8
µs

3.9

3.9

3.9
µs

tIS + tCK +

tIH
tIS + tCK +
tIH

ns
Auto precharge write recovery +
precharge time
Internal write to read command
delay
Internal read to precharge command
delay
Exit self refresh to a non-read
command
Exit self refresh to a read command
Exit precharge power down to any
non-read command
Exit active power down to read
command
Exit active power down to read
command
(slow exit/low power mode)
CKE minimum pulse width (high and
low pulse width)
Output impedance test driver delay
Auto refresh to active/auto refresh
command time
Average periodic refresh interval
(0°C ≤ TC ≤ +85°C)
(+85°C < TC ≤ +95°C)
tREFI
Minimum time clocks remains ON
tDELAY
after CKE asynchronously drops low
tIS + tCK +
tIH
(tWR/tCK)+

(tRP/tCK)
tCK
Notes
1
Notes: 1.
2.
3.
4.
For each of the terms above, if not already an integer, round to the next higher integer.
AL: Additive Latency.
MRS A12 bit defines which active power down exit timing to be applied.
The figures of Input Waveform Timing 1 and 2 are referenced from the input signal crossing at the
VIH(AC) level for a rising signal and VIL(AC) for a falling signal applied to the device under test.
5. The figures of Input Waveform Timing 1 and 2 are referenced from the input signal crossing at the
VIH(DC) level for a rising signal and VIL(DC) for a falling signal applied to the device under test.
DQS
CK
/DQS
/CK
tDS
tDH
tDS
tIS
tDH
tIH
tIS
tIH
VDDQ
VIH (AC)(min.)
VIH (DC)(min.)
VREF
VIL (DC)(max.)
VIL (AC)(max.)
VSS
VDDQ
VIH (AC)(min.)
VIH (DC)(min.)
VREF
VIL (DC)(max.)
VIL (AC)(max.)
VSS
Input Waveform Timing 1 (tDS, tDH)
Input Waveform Timing 2 (tIS, tIH)
Data Sheet E0705E20 (Ver. 2.0)
13
EDE5116AFSE
ODT AC Electrical Characteristics
Parameter
Symbol
min
max
Unit
ODT turn-on delay
tAOND
2
2
tCK
ODT turn-on
-6E
tAON
tAC(min)
tAC(max) + 700
ps
1
-5C, -4A
1
tAON
tAC(min)
tAC(max) + 1000
ps
ODT turn-on (power down mode)
tAONPD
tAC(min) + 2000
2tCK + tAC(max) + 1000
ps
ODT turn-off delay
tAOFD
2.5
2.5
tCK
ODT turn-off
tAOF
tAC(min)
tAC(max) + 600
ps
ODT turn-off (power down mode)
tAOFPD
tAC(min) + 2000
2.5tCK + tAC(max) + 1000
ps
ODT to power down entry latency
tANPD
3
3
tCK
ODT power down exit latency
tAXPD
8
8
tCK
Notes
2
Notes: 1. ODT turn on time min is when the device leaves high impedance and ODT resistance begins to turn on.
ODT turn on time max is when the ODT resistance is fully on. Both are measured from tAOND.
2. ODT turn off time min is when the device starts to turn off ODT resistance.
ODT turn off time max is when the bus is in high impedance. Both are measured from tAOFD.
AC Input Test Conditions
Parameter
Symbol
Value
Unit
Notes
Input reference voltage
VREF
0.5 × VDDQ
V
1
Input signal maximum peak to peak swing
VSWING(max.)
1.0
V
1
Input signal maximum slew rate
SLEW
1.0
V/ns
2, 3
Notes: 1. Input waveform timing is referenced to the input signal crossing through the VREF level applied to the
device under test.
2. The input signal minimum slew rate is to be maintained over the range from VIL(DC) (max.) to VIH(AC)
(min.) for rising edges and the range from VIH(DC) (min.) to VIL(AC) (max.) for falling edges as shown in
the below figure.
3. AC timings are referenced with input waveforms switching from VIL(AC) to VIH(AC) on the positive
transitions and VIH(AC) to VIL(AC) on the negative transitions.
Start of rising edge input timing
Start of falling edge input timing
VDDQ
VIH (AC)(min.)
VIH (DC)(min.)
VSWING(max.)
VREF
VIL (DC)(max.)
VIL (AC)(max.)
Falling slew =
VSS
∆TR
∆TF
VIH (DC)(min.) − VIL (AC)(max.)
Rising slew =
∆TF
VIH (AC) min. − VIL (DC)(max.)
AC Input Test Signal Wave forms
Measurement point
DQ
VTT
RT =25 Ω
Output Load
Data Sheet E0705E20 (Ver. 2.0)
14
∆TR
EDE5116AFSE
Clock
generator
Block Diagram
Bank 3
Bank 2
Bank 1
A0 to A12, BA0, BA1
Mode
register
Row
address
buffer
and
refresh
counter
Row decoder
CK
/CK
CKE
Memory cell array
Bank 0
Control logic
/CS
/RAS
/CAS
/WE
Command decoder
Sense amp.
Column decoder
Column
address
buffer
and
burst
counter
Data control circuit
Latch circuit
CK, /CK
DLL
Input & Output buffer
DQS, /DQS
ODT
DM
DQ
Data Sheet E0705E20 (Ver. 2.0)
15
EDE5116AFSE
Pin Function
CK, /CK (input pins)
CK and /CK are differential clock inputs. All address and control input signals are sampled on the crossing of the
positive edge of CK and negative edge of /CK. Output (read) data is referenced to the crossings of CK and /CK
(both directions of crossing).
/CS (input pin)
All commands are masked when /CS is registered high. /CS provides for external rank selection on systems with
multiple ranks. /CS is considered part of the command code.
/RAS, /CAS, /WE (input pins)
/RAS, /CAS and /WE (along with /CS) define the command being entered.
A0 to A12 (input pins)
Provided the row address for Active commands and the column address and Auto Precharge bit for Read/Write
commands to select one location out of the memory array in the respective bank. The address inputs also provide
the op-code during mode register set commands.
[Address Pins Table]
Address (A0 to A12)
Part number
Row address
Column address
EDE5116AFSE
AX0 to AX12
AY0 to AY9
Note
A10 (AP) (input pin)
A10 is sampled during a precharge command to determine whether the precharge applies to one bank (A10 = low)
or all banks (A10 = high). If only one bank is to be precharged, the bank is selected by BA0, BA1.
BA0, BA1 (input pins)
BA0 and BA1 define to which bank an active, read, write or precharge command is being applied. BA0 also
determines if the mode register or extended mode register is to be accessed during a MRS or EMRS cycle.
[Bank Select Signal Table]
BA0
BA1
Bank 0
L
L
Bank 1
H
L
Bank 2
L
H
Bank 3
H
H
Remark: H: VIH. L: VIL.
CKE (input pin)
CKE high activates, and CKE low deactivates, internal clock signals and device input buffers and output drivers.
Taking CKE low provides precharge power-down and Self Refresh operation (all banks idle), or active power-down
(row active in any bank). CKE is synchronous for power down entry and exit, and for self refresh entry. CKE is
asynchronous for self refresh exit. CKE must be maintained high throughout read and write accesses. Input buffers,
excluding CK, /CK and CKE are disabled during power-down. Input buffers, excluding CKE, are disabled during selfrefresh.
Data Sheet E0705E20 (Ver. 2.0)
16
EDE5116AFSE
UDM and LDM (input pins)
DMs are input mask signals for write data. UDM controls upper byte (DQ8 to DQ15) and LDM controls lower byte
(DQ0 to DQ7). Input data is masked when DMs are sampled high coincident with that input data during a Write
access. DMs are sampled on both edges of DQS. Although DM pins are input only, the DM loading matches the
DQ and DQS loading. In this datasheet, DM represents UDM and LDM.
DQ (input/output pins)
Bi-directional data bus.
UDQS, /UDQS, LDQS, /LDQS (input/output pins)
Output with read data, input with write data for source synchronous operation. UDQS, /UDQS and LDQS, /LDQS
control upper byte (DQ8 to DQ15) and lower byte (DQ0 to DQ7). Edge-aligned with read data, centered in write
data. Used to capture write data. /DQS can be disabled by EMRS. In this datasheet, DQS represents UDQS and
LDQS, /DQS represents /UDQS and /LDQS.
ODT (input pins)
ODT (On Die Termination control) is a registered high signal that enables termination resistance internal to the
DDR2 SDRAM. When enabled, ODT is applied to each DQ, UDQS, LDQS, /UDQS, /LDQS, UDM, and LDM signal.
The ODT pin will be ignored if the Extended Mode Register (EMRS) is programmed to disable ODT.
VDD, VSS, VDDQ, VSSQ (power supply)
VDD and VSS are power supply pins for internal circuits. VDDQ and VSSQ are power supply pins for the output
buffers.
VDDL and VSSDL (power supply)
VDDL and VSSDL are power supply pins for DLL circuits.
VREF (Power supply)
SSTL_18 reference voltage: (0.50 ± 0.01) × VDDQ
Data Sheet E0705E20 (Ver. 2.0)
17
EDE5116AFSE
Command Operation
Command Truth Table
The DDR2 SDRAM recognizes the following commands specified by the /CS, /RAS, /CAS, /WE and address pins.
CKE
Function
Symbol
Previous Current
cycle
cycle
/CS
/RAS /CAS /WE
BA1,
BA0
A12 to
A11
Mode register set
MRS
H
H
L
L
L
L
BA0 = 0 and MRS OP Code
1
Extended mode register set
EMRS
H
H
L
L
L
L
BA0 = 1 and EMRS OP Code
1
A10
A0 to
A9
Notes
Auto refresh
REF
H
H
L
L
L
H
×
×
×
×
1
Self refresh entry
SELF
H
L
L
L
L
H
×
×
×
×
1
Self refresh exit
SELFX
L
H
H
×
×
×
×
×
×
×
1, 6
L
H
L
H
H
H
×
×
×
×
Single bank precharge
PRE
H
H
L
L
H
L
BA
×
L
×
1, 2
Precharge all banks
PALL
H
H
L
L
H
L
×
×
H
×
1
Bank activate
ACT
H
H
L
L
H
H
BA
Row Address
Write
WRIT
H
H
L
H
L
L
BA
Column L
Column 1, 2, 3
Write with auto precharge
WRITA
H
H
L
H
L
L
BA
Column H
Column 1, 2, 3
Read
READ
H
H
L
H
L
H
BA
Column L
Column 1, 2, 3
Read with auto precharge
READA
H
H
L
H
L
H
BA
Column H
Column 1, 2, 3
No operation
NOP
H
×
L
H
H
H
×
×
×
×
1
Device deselect
DESL
H
×
H
×
×
×
×
×
×
×
1
Power down mode entry
PDEN
H
L
H
×
×
×
×
×
×
×
1, 4
H
L
L
H
H
H
×
×
×
×
L
H
H
×
×
×
×
×
×
×
L
H
L
H
H
H
×
×
×
×
Power down mode exit
PDEX
1, 2
1, 4
Remark: H = VIH. L = VIL. × = VIH or VIL
Notes: 1. All DDR2 commands are defined by states of /CS, /RAS, /CAS, /WE and CKE at the rising edge of the
clock.
2. Bank select (BA0, BA1), determine which bank is to be operated upon.
3. Burst reads or writes should not be terminated other than specified as ″Reads interrupted by a Read″ in
burst read command [READ] or ″Writes interrupted by a Write″ in burst write command [WRIT].
4. The power down mode does not perform any refresh operations. The duration of power down is therefore
limited by the refresh requirements of the device. One clock delay is required for mode entry and exit.
5. The state of ODT does not affect the states described in this table. The ODT function is not available
during self-refresh.
6. Self refresh exit is asynchronous.
Data Sheet E0705E20 (Ver. 2.0)
18
EDE5116AFSE
CKE Truth Table
CKE
*3
Previous
1
cycle (n-1)*
Current
*1
cycle (n)
Command(n)
/CS, /RAS, /CAS, /WE
Operation (n)
L
L
×
Maintain power down
11, 13, 15
L
H
DESL or NOP
Power down exit
4, 8, 11, 13
L
L
×
Maintain self refresh
11, 15
L
H
DESL or NOP
Self refresh exit
4, 5, 9
Bank Active
H
L
DESL or NOP
Active power down entry
4, 8, 10, 11, 13
All banks idle
H
L
DESL or NOP
Precharge power down entry
4, 8, 10, 11, 13
H
L
SELF
Self refresh entry
6, 9, 11, 13
H
H
Refer to the Command Truth Table
Current state*
2
Power down
Self refresh
Any state other than
listed above
*3
Notes
7
Remark: H = VIH. L = VIL. × = Don’t care
Notes: 1. CKE (n) is the logic state of CKE at clock edge n; CKE (n−1) was the state of CKE at the previous clock
edge.
2. Current state is the state of the DDR SDRAM immediately prior to clock edge n.
3. Command (n) is the command registered at clock edge n, and operation (n) is a result of Command (n).
4. All states and sequences not shown are illegal or reserved unless explicitly described elsewhere in this
document.
5. On self refresh exit, [DESL] or [NOP] commands must be issued on every clock edge occurring during the
tXSNR period. Read commands may be issued only after tXSRD (200 clocks) is satisfied.
6. Self refresh mode can only be entered from the all banks idle state.
7. Must be a legal command as defined in the command truth table.
8. Valid commands for power down entry and exit are [NOP] and [DESL] only.
9. Valid commands for self refresh exit are [NOP] and [DESL] only.
10. Power down and self-refresh can not be entered while read or write operations, (extended) mode register
set operations or precharge operations are in progress. See section Power Down and Self Refresh
Command for a detailed list of restrictions.
11. Minimum CKE high time is 3 clocks; minimum CKE low time is 3 clocks.
12. The state of ODT does not affect the states described in this table. The ODT function is not available
during self-refresh. See section ODT (On Die Termination).
13. The power down does not perform any refresh operations. The duration of power down mode is therefore
limited by the refresh requirements outlined in section automatic refresh command.
14. CKE must be maintained high while the SDRAM is in OCD calibration mode.
15. “×” means “don’t care” (including floating around VREF) in self refresh and power down. However ODT
must be driven high or low in power down if the ODT function is enabled (bit A2 or A6 set to “1” in
EMRS(1) ).
Data Sheet E0705E20 (Ver. 2.0)
19
EDE5116AFSE
Function Truth Table
The following tables show the operations that are performed when each command is issued in each state of the
DDR SDRAM.
Current state
/CS
Idle
Bank(s) active
Read
/RAS /CAS /WE
Address
Command
Operation
H
×
×
×
L
H
H
H
L
H
L
L
H
L
H
L
Notes
×
DESL
Nop or Power down
×
NOP
Nop or Power down
H
BA, CA, A10 (AP)
READ
ILLEGAL
L
H
BA, CA, A10 (AP)
READA
ILLEGAL
1
L
L
BA, CA, A10 (AP)
WRIT
ILLEGAL
1
H
L
L
BA, CA, A10 (AP)
WRITA
ILLEGAL
1
1
L
L
H
H
BA, RA
ACT
Row activating
L
L
H
L
BA, A10 (AP)
PRE
Precharge
L
L
H
L
A10 (AP)
PALL
Precharge all banks
L
L
L
H
×
REF
Auto refresh
2
L
L
L
H
×
SELF
Self refresh
2
L
L
L
L
BA, MRS-OPCODE
MRS
Mode register accessing
2
2
L
L
L
L
BA, EMRS-OPCODE
EMRS
Extended mode register accessing
H
×
×
×
×
DESL
Nop
L
H
H
H
×
NOP
Nop
L
H
L
H
BA, CA, A10 (AP)
READ
Begin Read
L
H
L
H
BA, CA, A10 (AP)
READA
Begin Read
L
H
L
L
BA, CA, A10 (AP)
WRIT
Begin Write
L
H
L
L
BA, CA, A10 (AP)
WRITA
Begin Write
L
L
H
H
BA, RA
ACT
ILLEGAL
L
L
H
L
BA, A10 (AP)
PRE
Precharge
L
L
H
L
A10 (AP)
PALL
Precharge all banks
L
L
L
H
×
REF
ILLEGAL
L
L
L
H
×
SELF
ILLEGAL
L
L
L
L
BA, MRS-OPCODE
MRS
ILLEGAL
L
L
L
L
BA, EMRS-OPCODE
EMRS
ILLEGAL
H
×
×
×
×
DESL
Continue burst to end -> Row active
1
L
H
H
H
×
NOP
Continue burst to end -> Row active
L
H
L
H
BA, CA, A10 (AP)
READ
Burst interrupt
1, 4
L
H
L
H
BA, CA, A10 (AP)
READA
Burst interrupt
1, 4
L
H
L
L
BA, CA, A10 (AP)
WRIT
ILLEGAL
1
L
H
L
L
BA, CA, A10 (AP)
WRITA
ILLEGAL
1
L
L
H
H
BA, RA
ACT
ILLEGAL
1
L
L
H
L
BA, A10 (AP)
PRE
ILLEGAL
1
L
L
H
L
A10 (AP)
PALL
ILLEGAL
L
L
L
H
×
REF
ILLEGAL
L
L
L
H
×
SELF
ILLEGAL
L
L
L
L
BA, MRS-OPCODE
MRS
ILLEGAL
L
L
L
L
BA, EMRS-OPCODE
EMRS
ILLEGAL
Data Sheet E0705E20 (Ver. 2.0)
20
EDE5116AFSE
Current state
/CS
/RAS /CAS /WE
Address
Command
Operation
Note
Write
H
×
×
×
×
DESL
L
H
H
H
×
NOP
L
H
L
H
BA, CA, A10 (AP)
READ
ILLEGAL
1
L
H
L
H
BA, CA, A10 (AP)
READA
ILLEGAL
1
L
H
L
L
BA, CA, A10 (AP)
WRIT
Burst interrupt
1, 4
L
H
L
L
BA, CA, A10 (AP)
WRITA
Burst interrupt
1, 4
L
L
H
H
BA, RA
ACT
ILLEGAL
1
L
L
H
L
BA, A10 (AP)
PRE
ILLEGAL
1
Continue burst to end
-> Write recovering
Continue burst to end
-> Write recovering
L
L
H
L
A10 (AP)
PALL
ILLEGAL
L
L
L
H
×
REF
ILLEGAL
L
L
L
H
×
SELF
ILLEGAL
L
L
L
L
BA, MRS-OPCODE
MRS
L
L
L
L
BA, EMRS-OPCODE EMRS
ILLEGAL
Read with
H
×
×
×
×
DESL
Continue burst to end -> Precharging
auto precharge
L
H
H
H
×
NOP
Continue burst to end -> Precharging
L
H
L
H
BA, CA, A10 (AP)
READ
ILLEGAL
1
L
H
L
H
BA, CA, A10 (AP)
READA
ILLEGAL
1
L
H
L
L
BA, CA, A10 (AP)
WRIT
ILLEGAL
1
L
H
L
L
BA, CA, A10 (AP)
WRITA
ILLEGAL
1
L
L
H
H
BA, RA
ACT
ILLEGAL
1
L
L
H
L
BA, A10 (AP)
PRE
ILLEGAL
1
L
L
H
L
A10 (AP)
PALL
ILLEGAL
L
L
L
H
×
REF
ILLEGAL
L
L
L
H
×
SELF
ILLEGAL
L
L
L
L
BA, MRS-OPCODE
MRS
ILLEGAL
L
L
L
L
BA, EMRS-OPCODE EMRS
ILLEGAL
H
×
×
×
×
DESL
L
H
H
H
×
NOP
Continue burst to end
->Write recovering with auto precharge
Continue burst to end
->Write recovering with auto precharge
L
H
L
H
BA, CA, A10 (AP)
READ
ILLEGAL
1
L
H
L
H
BA, CA, A10 (AP)
READA
ILLEGAL
1
L
H
L
L
BA, CA, A10 (AP)
WRIT
ILLEGAL
1
L
H
L
L
BA, CA, A10 (AP)
WRITA
ILLEGAL
1
L
L
H
H
BA, RA
ACT
ILLEGAL
1
L
L
H
L
BA, A10 (AP)
PRE
ILLEGAL
1
L
L
H
L
A10 (AP)
PALL
ILLEGAL
L
L
L
H
×
REF
ILLEGAL
L
L
L
H
×
SELF
ILLEGAL
L
L
L
L
BA, MRS-OPCODE
MRS
ILLEGAL
L
L
L
L
BA, EMRS-OPCODE EMRS
Write with auto
Precharge
Data Sheet E0705E20 (Ver. 2.0)
21
ILLEGAL
ILLEGAL
EDE5116AFSE
Current state
/CS
/RAS /CAS /WE
Address
Command
Operation
Precharging
H
×
×
×
×
DESL
Nop -> Enter idle after tRP
L
H
H
H
×
NOP
Nop -> Enter idle after tRP
L
H
L
H
BA, CA, A10 (AP)
READ
ILLEGAL
1
L
H
L
H
BA, CA, A10 (AP)
READA
ILLEGAL
1
L
H
L
L
BA, CA, A10 (AP)
WRIT
ILLEGAL
1
L
H
L
L
BA, CA, A10 (AP)
WRITA
ILLEGAL
1
L
L
H
H
BA, RA
ACT
ILLEGAL
1
L
L
H
L
BA, A10 (AP)
PRE
Nop -> Enter idle after tRP
Row activating
Write recovering
Note
L
L
H
L
A10 (AP)
PALL
Nop -> Enter idle after tRP
L
L
L
H
×
REF
ILLEGAL
L
L
L
H
×
SELF
ILLEGAL
L
L
L
L
BA, MRS-OPCODE
MRS
ILLEGAL
L
L
L
L
BA, EMRS-OPCODE
EMRS
ILLEGAL
H
×
×
×
×
DESL
Nop -> Enter bank active after tRCD
L
H
H
H
×
NOP
Nop -> Enter bank active after tRCD
L
H
L
H
BA, CA, A10 (AP)
READ
ILLEGAL
L
H
L
H
BA, CA, A10 (AP)
READA
ILLEGAL
1
L
H
L
L
BA, CA, A10 (AP)
WRIT
ILLEGAL
1
L
H
L
L
BA, CA, A10 (AP)
WRITA
ILLEGAL
1
L
L
H
H
BA, RA
ACT
ILLEGAL
1
L
L
H
L
BA, A10 (AP)
PRE
ILLEGAL
L
L
H
L
A10 (AP)
PALL
ILLEGAL
L
L
L
H
×
REF
ILLEGAL
L
L
L
H
×
SELF
ILLEGAL
L
L
L
L
BA, MRS-OPCODE
MRS
ILLEGAL
1
L
L
L
L
BA, EMRS-OPCODE
EMRS
ILLEGAL
H
×
×
×
×
DESL
Nop -> Enter bank active after tWR
L
H
H
H
×
NOP
Nop -> Enter bank active after tWR
L
H
L
H
BA, CA, A10 (AP)
READ
ILLEGAL
1
L
H
L
H
BA, CA, A10 (AP)
READA
ILLEGAL
1
L
H
L
L
BA, CA, A10 (AP)
WRIT
New write
L
H
L
L
BA, CA, A10 (AP)
WRITA
New write
L
L
H
H
BA, RA
ACT
ILLEGAL
1
L
L
H
L
BA, A10 (AP)
PRE
ILLEGAL
1
L
L
H
L
A10 (AP)
PALL
ILLEGAL
L
L
L
H
×
REF
ILLEGAL
L
L
L
H
×
SELF
ILLEGAL
L
L
L
L
BA, MRS-OPCODE
MRS
ILLEGAL
L
L
L
L
BA, EMRS-OPCODE
EMRS
ILLEGAL
Data Sheet E0705E20 (Ver. 2.0)
22
EDE5116AFSE
Current state
/CS
/RAS /CAS /WE
Address
Command
Operation
Write recovering
with
H
×
×
×
×
DESL
Nop -> Enter bank active after tWR
auto precharge
L
H
H
H
×
NOP
Nop -> Enter bank active after tWR
L
H
L
H
BA, CA, A10 (AP)
READ
ILLEGAL
1
L
H
L
H
BA, CA, A10 (AP)
READA
ILLEGAL
1
L
H
L
L
BA, CA, A10 (AP)
WRIT
ILLEGAL
1
L
H
L
L
BA, CA, A10 (AP)
WRITA
ILLEGAL
1
L
L
H
H
BA, RA
ACT
ILLEGAL
1
L
L
H
L
BA, A10 (AP)
PRE
ILLEGAL
1
L
L
H
L
A10 (AP)
PALL
ILLEGAL
L
L
L
H
×
REF
ILLEGAL
L
L
L
H
×
SELF
ILLEGAL
L
L
L
L
BA, MRS-OPCODE
MRS
ILLEGAL
L
L
L
L
BA, EMRS-OPCODE
EMRS
ILLEGAL
H
×
×
×
×
DESL
Nop -> Enter idle after tRFC
L
H
H
H
×
NOP
Nop -> Enter idle after tRFC
L
H
L
H
BA, CA, A10 (AP)
READ
ILLEGAL
L
H
L
H
BA, CA, A10 (AP)
READA
ILLEGAL
L
H
L
L
BA, CA, A10 (AP)
WRIT
ILLEGAL
L
H
L
L
BA, CA, A10 (AP)
WRITA
ILLEGAL
Refresh
Mode register
accessing
L
L
H
H
BA, RA
ACT
ILLEGAL
L
L
H
L
BA, A10 (AP)
PRE
ILLEGAL
L
L
H
L
A10 (AP)
PALL
ILLEGAL
L
L
L
H
×
REF
ILLEGAL
L
L
L
H
×
SELF
ILLEGAL
L
L
L
L
BA, MRS-OPCODE
MRS
ILLEGAL
L
L
L
L
BA, EMRS-OPCODE
EMRS
ILLEGAL
H
×
×
×
×
DESL
Nop -> Enter idle after tMRD
L
H
H
H
×
NOP
Nop -> Enter idle after tMRD
L
H
L
H
BA, CA, A10 (AP)
READ
ILLEGAL
L
H
L
H
BA, CA, A10 (AP)
READA
ILLEGAL
L
H
L
L
BA, CA, A10 (AP)
WRIT
ILLEGAL
L
H
L
L
BA, CA, A10 (AP)
WRITA
ILLEGAL
L
L
H
H
BA, RA
ACT
ILLEGAL
L
L
H
L
BA, A10 (AP)
PRE
ILLEGAL
L
L
H
L
A10 (AP)
PALL
ILLEGAL
L
L
L
H
×
REF
ILLEGAL
L
L
L
H
×
SELF
ILLEGAL
L
L
L
L
BA, MRS-OPCODE
MRS
ILLEGAL
L
L
L
L
BA, EMRS-OPCODE
EMRS
ILLEGAL
Data Sheet E0705E20 (Ver. 2.0)
23
Note
EDE5116AFSE
Current state
/CS
/RAS /CAS /WE
Address
Command
Operation
Extended Mode
H
×
×
×
×
DESL
Nop -> Enter idle after tMRD
register accessing L
H
H
H
×
NOP
Nop -> Enter idle after tMRD
L
H
L
H
BA, CA, A10 (AP)
READ
ILLEGAL
L
H
L
H
BA, CA, A10 (AP)
READA
ILLEGAL
L
H
L
L
BA, CA, A10 (AP)
WRIT
ILLEGAL
L
H
L
L
BA, CA, A10 (AP)
WRITA
ILLEGAL
L
L
H
H
BA, RA
ACT
ILLEGAL
L
L
H
L
BA, A10 (AP)
PRE
ILLEGAL
L
L
H
L
A10 (AP)
PALL
ILLEGAL
L
L
L
H
×
REF
ILLEGAL
L
L
L
H
×
SELF
ILLEGAL
L
L
L
L
BA, MRS-OPCODE
MRS
ILLEGAL
L
L
L
L
BA, EMRS-OPCODE
EMRS
ILLEGAL
Remark:
Notes: 1.
2.
3.
4.
H = VIH. L = VIL. × = VIH or VIL
This command may be issued for other banks, depending on the state of the banks.
All banks must be in "IDLE".
All AC timing specs must be met.
Only allowed at the boundary of 4 bits burst. Burst interruption at other timings are illegal.
Data Sheet E0705E20 (Ver. 2.0)
24
Note
EDE5116AFSE
Simplified State Diagram
CKEL
INITALIZATION
AUTO REFRESH
SELF REFRESH
X
LF
SE
REF
tRFC
CKEL
PDEN
PRECHARGE
POWER
DOWN
LF
SE
MRS
IDLE
CKEH
MRS
EMRS
PRE
ACT
tMRD
ACTIVATING
tRCD
WL + BL/2 + tWR
PR
E
DA
REA
READ
E
PR
WRITE
READA
PRECHARGE
READA
WRIT
WRITA
WRITA
tRP
READ
READ
A
CKEL
RE
AD
T
PRE
RI
TA
RI
W
W
AD
RE
ACTIVE
POWER
DOWN
PDEN
BANK ACTIVE
CKEH
Automatic sequence
Command sequence
Simplified State Diagram
Data Sheet E0705E20 (Ver. 2.0)
25
EDE5116AFSE
Operation of DDR2 SDRAM
Read and write accesses to the DDR2 SDRAM are burst oriented; accesses start at a selected location and continue
for the fixed burst length of four or eight in a programmed sequence. Accesses begin with the registration of an
active command, which is then followed by a read or write command. The address bits registered coincident with
the active command is used to select the bank and row to be accessed (BA0, BA1 select the bank; A0 to A12 select
the row). The address bits registered coincident with the read or write command are used to select the starting
column location for the burst access and to determine if the auto precharge command is to be issued.
Prior to normal operation, the DDR2 SDRAM must be initialized. The following sections provide detailed information
covering device initialization; register definition, command descriptions and device operation.
Power On and Initialization
DDR2 SDRAMs must be powered up and initialized in a predefined manner. Operational procedures other than
those specified may result in undefined operation.
Power-Up and Initialization Sequence
The following sequence is required for power up and initialization.
1
1. Apply power and attempt to maintain CKE below 0.2 × VDDQ and ODT * at a low state (all other inputs may be
undefined.)
 VDD, VDDL and VDDQ are driven from a single power converter output, AND
 VTT is limited to 0.95V max, AND
 VREF tracks VDDQ/2.
or
 Apply VDD before or at the same time as VDDL.
 Apply VDDL before or at the same time as VDDQ.
 Apply VDDQ before or at the same time as VTT and VREF.
at least one of these two sets of conditions must be met.
2. Start clock and maintain stable condition.
3. For the minimum of 200µs after stable power and clock(CK, /CK), then apply [NOP] or [DESL] and take CKE
high.
4. Wait minimum of 400ns then issue precharge all command. [NOP] or [DESL] applied during 400ns period.
5. Issue EMRS(2) command. (To issue EMRS(2) command, provide low to BA0, high to BA1.)
6. Issue EMRS(3) command. (To issue EMRS(3) command, high to BA0 and BA1.)
7. Issue EMRS to enable DLL. (To issue DLL enable command, provide low to A0, high to BA0 and low to BA1 and
A12.)
8. Issue a mode register set command for DLL reset.
(To issue DLL reset command, provide high to A8 and low to BA0, BA1, and A12 )
9. Issue precharge all command.
10. Issue 2 or more auto-refresh commands.
11. Issue a mode register set command with low to A8 to initialize device operation. (i.e. to program operating
parameters without resetting the DLL.)
12. At least 200 clocks after step 8, execute OCD calibration (Off Chip Driver impedance adjustment). If OCD
calibration is not used, EMRS OCD default command (A9 = A8 = A7 = 1) followed by EMRS OCD calibration
mode exit command (A9 = A8 = A7 = 0) must be issued with other operating parameters of EMRS.
13. The DDR2 SDRAM is now ready for normal operation.
Note: 1. To guarantee ODT off, VREF must be valid and a low level must be applied to the ODT pin.
tCH tCL
CK
/CK
tIS
CKE
Command
PALL
NOP
400ns
EMRS
tRP
tMRD
DLL enable
PALL
MRS
tMRD
REF
REF
tRP
tRFC
MRS
tRFC
DLL reset
EMRS
tMRD
Follow OCD
Flowchart
OCD default
200 cycles (min)
Power up and Initialization Sequence
Data Sheet E0705E20 (Ver. 2.0)
26
Any
command
EMRS
tOIT
OCD calibration mode
exit
EDE5116AFSE
Programming the Mode Register and Extended Mode Registers
For application flexibility, burst length, burst type, /CAS latency, DLL reset function, write recovery time (tWR)
are user defined variables and must be programmed with a mode register set command [MRS]. Additionally, DLL
disable function, driver impedance, additive /CAS latency, ODT (On Die Termination), single-ended strobe, and OCD
(Off-Chip Driver Impedance Adjustment) are also user defined variables and must be programmed with an extended
mode register set command [EMRS]. Contents of the Mode Register (MR) or Extended Mode Registers (EMR (#))
can be altered by reexecuting the MRS and EMRS commands. If the user chooses to modify only a subset of the
MRS or EMRS variables, all variables must be redefined when the MRS or EMRS commands are issued.
MRS, EMRS and Reset DLL do not affect array contents, which means reinitialization including those can be
executed any time after power-up without affecting array contents.
DDR2 SDRAM Mode Register Set [MRS]
The mode register stores the data for controlling the various operating modes of DDR2 SDRAM. It controls /CAS
latency, burst length, burst sequence, test mode, DLL reset, tWR and various vendor specific options to make DDR2
SDRAM useful for various applications. The default value of the mode register is not defined, therefore the mode
register must be written after power-up for proper operation. The mode register is written by asserting low on /CS,
/RAS, /CAS, /WE, BA0 and BA1, while controlling the state of address pins A0 to A12.
The DDR2 SDRAM should be in all bank precharge with CKE already high prior to writing into the mode register.
The mode register set command cycle time (tMRD) is required to complete the write operation to the mode register.
The mode register contents can be changed using the same command and clock cycle requirements during normal
operation as long as all banks are in the precharge state. The mode register is divided into various fields depending
on functionality. Burst length is defined by A0 to A2 with options of 4 and 8 bit burst lengths. The burst length
decodes are compatible with DDR SDRAM. Burst address sequence type is defined by A3, /CAS latency is defined
by A4 to A6. The DDR2 doesn’t support half clock latency mode. A7 is used for test mode. A8 is used for DLL reset.
A7 must be set to low for normal MRS operation. Write recovery time tWR is defined by A9 to A11. Refer to the
table for specific codes.
BA1 BA0 A12 A11 A10 A9
0*1
PD
WR
A7
A6
DLL TM
A5
A4
A3
/CAS latency
BT
A2
A1
A0
Burst length
A8
DLL reset
A7
Mode
A3
Burst type
0
No
0
Normal
0
Sequential
1
BA1 BA0
0
A8
1
Yes
1
Test
Address field
Mode register
Burst length
Interleave
A2
A1
A0
BL
0
1
0
4
0
1
1
8
MRS mode
Write recovery for autoprecharge
/CAS latency
A11
A10
A9
WR
A6
A5
A4
Latency
1
0
EMRS(2): Reserved
0
0
0
Reserved
0
0
0
Reserved
1
1
EMRS(3): Reserved
0
0
1
2
0
0
1
Reserved
0
1
0
3
0
1
0
Reserved
0
1
1
3
4
DDR2 667
EMRS(1)
DDR2 800
MRS
1
DDR2 400
0
0
DDR2 533
0
A12
Active power down exit timing
0
1
1
4
0
Fast exit (use tXARD timing)
1
0
0
5
1
0
0
1
Slow exit (use tXARDS timing)
1
0
1
6
1
0
1
5
1
1
0
Reserved
1
1
0
Reserved
1
1
1
Reserved
1
1
1
Reserved
Notes: 1. BA1 is reserved for future use and must be programmed to 0 when setting the mode register.
2. WR (min.) (Write Recovery for autoprecharge) is determined by tCK (max.) and WR (max.) is determined by tCK (min.).
WR in clock cycles is calculated by dividing tWR (in ns) by tCK (in ns) and rounding up to the next integer
(WR [cycles] = tWR (ns) / tCK (ns)).
The mode register must be programmed to this value. This is also used with tRP to determine tDAL.
Mode Register Set (MRS)
Data Sheet E0705E20 (Ver. 2.0)
27
EDE5116AFSE
DDR2 SDRAM Extended Mode Registers Set [EMRS]
EMRS (1) Programming
The extended mode register (1) stores the data for enabling or disabling the DLL, output driver strength, additive
latency, ODT, /DQS disable, OCD program. The default value of the extended mode register (1) is not defined,
therefore the extended mode register (1) must be written after power-up for proper operation. The extended mode
register (1) is written by asserting low on /CS, /RAS, /CAS, /WE, high on BA0 and low on BA1, while controlling the
states of address pins A0 to A12. The DDR2 SDRAM should be in all bank precharge with CKE already high prior to
writing into the extended mode register (1). The mode register set command cycle time (tMRD) must be satisfied to
complete the write operation to the extended mode register (1). Mode register contents can be changed using the
same command and clock cycle requirements during normal operation as long as all banks are in the precharge
state. A0 is used for DLL enable or disable. A1 is used for enabling a half strength output driver. A3 to A5
determines the additive latency, A7 to A9 are used for OCD control and A10 is used for /DQS disable. A2 and A6
are used for ODT setting.
BA1 BA0 A12 A11 A10 A9
0
1
BA1 BA0
0
0
0
Qoff
A8
A7
A6
0* 1 /DQS OCD program
A5
1
EMRS(1)
1
0
EMRS(2): Reserved
1
1
EMRS(3): Reserved
A3
A2
A1
A0
Address field
Rtt Additive latency Rtt D.I.C DLL
MRS mode
MRS
A4
A6
A2
Rtt (nominal )
0
0
ODT Disabled
0
1
75Ω
1
0
150Ω
1
1
50Ω
Extended mode register
A0
DLL enable
0
Enable
1
Disable
Driver impedance adjustment
A8
A7
0
0
0
OCD calibration mode exit
0
0
1
Drive(1)
0
1
0
Drive(0)
A5
A4
A3
Latency
1
0
0
Adjust mode* 2
0
0
0
0
1
1
1
OCD Calibration default* 3
0
0
1
1
0
1
0
2
0
1
1
3
1
0
0
4
1
0
1
Reserved
1
1
0
Reserved
1
1
1
Reserved
A12
Qoff
0
Output buffers enabled
1
Output buffers disabled
A10
Operation
A9
Additive latency
/DQS enable
0
Enable
1
Disable
Driver strength control
A10
Strobe function matrix
Output driver
Driver
(/DQS enable)
DQS
/DQS
A1
impedance control
size
0 (Enable)
DQS
/DQS
0
Normal
100%
1 (Disable)
DQS
High-Z
1
Weak
60%
Notes: 1. A11 is reserved for future use, and must be programmed to 0 when setting the extended mode register.
2. When adjust mode is issued, AL from previously set value must be applied.
3. After setting to default, OCD mode needs to be exited by setting A9 to A7 to 000.
Refer to the chapter Off-Chip Driver (OCD)Impedance Adjustment for detailed information.
EMRS (1)
Data Sheet E0705E20 (Ver. 2.0)
28
EDE5116AFSE
DLL Enable/Disable
The DLL must be enabled for normal operation. DLL enable is required during power up initialization, and upon
returning to normal operation after having the DLL disabled. The DLL is automatically disabled when entering selfrefresh operation and is automatically re-enabled upon exit of self-refresh operation. Any time the DLL is enabled
(and subsequently reset), 200 clock cycles must occur before a read command can be issued to allow time for the
internal clock to be synchronized with the external clock. Failing to wait for synchronization to occur may result in a
violation of the tAC or tDQSCK parameters.
EMRS (2) Programming*1
The extended mode register (2) controls refresh related features. The default value of the extended mode
register (2) is not defined, therefore the extended mode register (2) must be written after power-up for proper
operation. The extended mode register (2) is written by asserting low on CS, /RAS, /CAS, /WE, high on BA1 and low
on BA0, while controlling the states of address pins A0 to A12. The DDR2 SDRAM should be in all bank precharge
with CKE already high prior to writing into the extended mode register (2). The mode register set command cycle
time (tMRD) must be satisfied to complete the write operation to the extended mode register (2). Mode register
contents can be changed using the same command and clock cycle requirements during normal operation as long
as all banks are in the precharge state.
BA1 BA0 A12
1
A11
A10
A9
A8
0*1
0
A7
A6
A5
A4
A3
A2
A1
A0
Extended mode register (2)
0*1
SRF
Address field
High Temperature
Self-refresh rate
Enable
A7
0
Disable
1
Enable (Optional)
Note: 1 The rest bits in EMRS (2) is reserved for future use and all bits in EMRS (2) except A7, BA0 and BA1
must be programmed to 0 when setting the extended mode register (2) during initialization.
EMRS(2)
EMRS (3) Programming: Reserved*1
BA1 BA0 A12
1
A11
1
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
A0
Address Field
Extended Mode Register(3)
0*1
Note : 1. EMRS (3) is reserved for future use and all bits except BA0 and BA1 must be programmed
to 0 when setting the mode register during initialization.
EMRS (3)
Data Sheet E0705E20 (Ver. 2.0)
29
EDE5116AFSE
Off-Chip Driver (OCD) Impedance Adjustment
DDR2 SDRAM supports driver calibration feature and the OCD Flow Chart is an example of sequence. Every
calibration mode command should be followed by “OCD calibration mode exit” before any other command being
issued. MRS should be set before entering OCD impedance adjustment and ODT (On Die Termination) should be
carefully controlled depending on system environment.
MRS should be set before entering OCD impedance adjustment and ODT should
be carefully controlled depending on system environment
Start
EMRS: OCD calibration mode exit
EMRS: Drive(1)
EMRS: Drive(0)
DQ & DQS high ; /DQS low
DQ & DQS low ; /DQS high
ALL OK
ALL OK
Test
Need calibration
Test
Need calibration
EMRS: OCD calibration mode exit
EMRS: OCD calibration mode exit
EMRS :
EMRS :
Enter Adjust Mode
Enter Adjust Mode
BL=4 code input to all DQs
BL=4 code input to all DQs
Inc, Dec, or NOP
Inc, Dec, or NOP
EMRS: OCD calibration mode exit
EMRS: OCD calibration mode exit
EMRS: OCD calibration mode exit
End
OCD Flow Chart
Data Sheet E0705E20 (Ver. 2.0)
30
EDE5116AFSE
Extended Mode Register Set for OCD Impedance Adjustment
OCD impedance adjustment can be done using the following EMRS mode. In drive mode all outputs are driven out
by DDR2 SDRAM. In Drive (1) mode, all DQ, DQS signals are driven high and all /DQS signals are driven low. In
drive (0) mode, all DQ, DQS signals are driven low and all /DQS signals are driven high.
In adjust mode, BL = 4 of operation code data must be used. In case of OCD calibration default, output driver
characteristics follow approximate nominal V/I curve for 18Ω output drivers, but are not guaranteed. If tighter control
is required, which is controlled within 18Ω ± 3Ω driver impedance range, OCD must be used.
[OCD Mode Set Program]
A9
A8
A7
Operation
0
0
0
OCD calibration mode exit
0
0
1
Drive (1) DQ, DQS high and /DQS low
0
1
0
Drive (0) DQ, DQS low and /DQS high
1
0
0
Adjust mode
1
1
1
OCD calibration default
OCD Impedance Adjustment
To adjust output driver impedance, controllers must issue the ADJUST EMRS command along with a 4bit burst code
to DDR2 SDRAM as in OCD Adjustment Program table. For this operation, burst length has to be set to BL = 4 via
MRS command before activating OCD and controllers must drive this burst code to all DQs at the same time. DT0 in
OCD Adjustment Program table means all DQ bits at bit time 0, DT1 at bit time 1, and so forth. The driver output
impedance is adjusted for all DDR2 SDRAM DQs simultaneously and after OCD calibration, all DQs of a given
DDR2 SDRAM will be adjusted to the same driver strength setting. The maximum step count for adjustment is 16
and when the limit is reached, further increment or decrement code has no effect. The default setting may be any
step within the 16-step range.
[OCD Adjustment Program]
4bits burst data inputs to all DQs
Operation
DT0
DT1
DT2
DT3
Pull-up driver strength
Pull-down driver strength
0
0
0
0
NOP
NOP
0
0
0
1
Increase by 1 step
NOP
0
0
1
0
Decrease by 1 step
NOP
0
1
0
0
NOP
Increase by 1 step
1
0
0
0
NOP
Decrease by 1 step
0
1
0
1
Increase by 1 step
Increase by 1 step
0
1
1
0
Decrease by 1 step
Increase by 1 step
1
0
0
1
Increase by 1 step
Decrease by 1 step
1
0
1
0
Decrease by 1 step
Decrease by 1 step
Other combinations
Reserved
Data Sheet E0705E20 (Ver. 2.0)
31
EDE5116AFSE
For proper operation of adjust mode, WL = RL − 1 = AL + CL − 1 clocks and tDS/tDH should be met as the Output
Impedance Control Register Set Cycle. For input data pattern for adjustment, DT0 to DT3 is a fixed order and not
affected by MRS addressing mode (i.e. sequential or interleave).
/CK
CK
Command
EMRS
NOP
EMRS
WL
NOP
tWR
DQS, /DQS
tDS tDH
DQ_in
DT0
DT1
DT2
DT3
OCD adjust mode
OCD calibration mode exit
Output Impedance Control Register Set Cycle
Drive Mode
Drive mode, both drive (1) and drive (0), is used for controllers to measure DDR2 SDRAM Driver impedance before
OCD impedance adjustment. In this mode, all outputs are driven out tOIT after “Enter drive mode” command and all
output drivers are turned-off tOIT after “OCD calibration mode exit” command as the ”Output Impedance
Measurement/Verify Cycle”.
/CK
CK
Command
EMRS
NOP
EMRS
High-Z
High-Z
DQS, /DQS
DQs high and /DQS low for drive (1), DQs low and /DQS high for drive (0)
DQs high for drive (1)
DQ
DQs low for drive (0)
tOIT
tOIT
Enter drivemode
OCD Calibration mode exit
Output Impedance Measurement/Verify Cycle
Data Sheet E0705E20 (Ver. 2.0)
32
EDE5116AFSE
ODT(On Die Termination)
On Die Termination (ODT), is a feature that allows a DRAM to turn on/off termination resistance for each DQ, UDQS,
LDQS, /UDQS, /LDQS, UDM, and LDM signal via the ODT control pin. The ODT feature is designed to improve
signal integrity of the memory channel by allowing the DRAM controller to independently turn on/off termination
resistance for any or all DRAM devices.
The ODT function is turned off and not supported in self-refresh mode.
VDDQ
VDDQ
VDDQ
sw3
sw2
sw1
Rval3
Rval2
Rval1
DRAM
input
buffer
Input
Pin
Rval1
sw1
VSSQ
Rval2
Rval3
sw2
sw3
VSSQ
VSSQ
Switch sw1, sw2 or sw3 is enabled by ODT pin.
Selection between sw1, sw2 or sw3 is determined by Rtt (nominal) in EMRS
Termination included on all DQs, UDM, LDM, UDQS, LDQS, /UDQS and /LDQS pins.
Target Rtt (Ω) = (Rval1) / 2, (Rval2) / 2 or (Rval3) / 2
Functional Representation of ODT
Data Sheet E0705E20 (Ver. 2.0)
33
EDE5116AFSE
/CK
T0
T1
T2
T3
T4
T5
T6
CK
CKE
tAXPD ≤ 6tCK
tIS
tIS
ODT
tAOFD
tAOND
Internal
Term Res.
Rtt
tAON min.
tAOF min.
tAON max.
tAOF max.
ODT Timing for Active and Standby Mode
/CK
T0
T1
T2
T3
T4
T5
T6
CK
CKE
tAXPD ≤ 6tCK
tIS
tIS
ODT
tAOFPD max.
tAOFPD min.
Internal
Term Res.
Rtt
tAONPD min.
tAONPD max.
ODT Timing for Power down Mode
Data Sheet E0705E20 (Ver. 2.0)
34
EDE5116AFSE
T-5
T-4
T-3
T-2
T-1
T0
T1
T2
T3
T4
/CK
CK
tANPD
tIS
CKE
Entering slow exit active power down mode
or precharge power down mode.
tIS
ODT
Active and standby
mode timings to
be applied.
tAOFD
Internal
Term Res.
Rtt
tIS
ODT
Power down
mode timings to
be applied.
tAOFPD(max.)
Internal
Term Res.
Rtt
tIS
ODT
tAOND
Internal
Term Res.
Active and standby
mode timings to
be applied.
Rtt
tIS
ODT
Power down
mode timings to
be applied.
tAONPD(max.)
Internal
Term Res.
Rtt
ODT Timing Mode Switch at Entering Power Down Mode
Data Sheet E0705E20 (Ver. 2.0)
35
EDE5116AFSE
T0
T1
T4
T5
T6
T7
T8
T9
T10
T11
/CK
CK
tIS
tAXPD
CKE
Exiting from slow active power down mode
or precharge power down mode.
tIS
Active and standby
mode timings to
be applied.
ODT
tAOFD
Internal
Term Res.
Rtt
tIS
Power down
mode timings to
be applied.
ODT
tAOFPD (max.)
Internal
Term Res.
Rtt
tIS
Active and standby
mode timings to
be applied.
ODT
tAOND
Internal
Term Res.
Rtt
tIS
Power down
mode timings to
be applied.
ODT
tAONPD(max.)
Internal
Term Res.
Rtt
ODT Timing Mode Switch at Exiting Power Down Mode
Data Sheet E0705E20 (Ver. 2.0)
36
EDE5116AFSE
Bank Activate Command [ACT]
The bank activate command is issued by holding /CAS and /WE high with /CS and /RAS low at the rising edge of the
clock. The bank addresses BA0 and BA1, are used to select the desired bank. The row address A0 through A12 is
used to determine which row to activate in the selected bank. The Bank activate command must be applied before
any read or write operation can be executed. Immediately after the bank active command, the DDR2 SDRAM can
accept a read or write command on the following clock cycle. If a R/W command is issued to a bank that has not
satisfied the tRCD (min.) specification, then additive latency must be programmed into the device to delay when the
R/W command is internally issued to the device. The additive latency value must be chosen to assure tRCD (min.)
is satisfied. Additive latencies of 0, 1, 2, 3 and 4 are supported. Once a bank has been activated it must be
precharged before another bank activate command can be applied to the same bank. The bank active and
precharge times are defined as tRAS and tRP, respectively. The minimum time interval between successive bank
activate commands to the same bank is determined by the /RAS cycle time of the device (tRC), which is equal to
tRAS + tRP. The minimum time interval between successive bank activate commands to the different bank is
determined by (tRRD).
/CK
T0
T1
T2
T3
Tn
Tn+1
Tn+2
Tn+3
PRE
ACT
CK
Command
ACT
Posted
READ
ACT
Posted
READ
PRE
tRCD(min.)
Address
ROW: 0
COL: 0
ROW: 1
COL: 1
ROW: 0
tCCD
Additive latency (AL)
tRCD =1
Bank0 Read begins
tRRD
tRAS
tRP
tRC
Bank0
Active
Bank1
Active
Bank0
Precharge
Bank1
Precharge
Bank Activate Command Cycle (tRCD = 3, AL = 2, tRP = 3, tRRD = 2, tCCD = 2)
Data Sheet E0705E20 (Ver. 2.0)
37
Bank0
Active
EDE5116AFSE
Read and Write Access Modes
After a bank has been activated, a read or write cycle can be executed. This is accomplished by setting /RAS high,
/CS and /CAS low at the clock’s rising edge. /WE must also be defined at this time to determine whether the access
cycle is a read operation (/WE high) or a write operation (/WE low).
The DDR2 SDRAM provides a fast column access operation. A single read or write command will initiate a serial
read or write operation on successive clock cycles. The boundary of the burst cycle is strictly restricted to specific
segments of the page length. For example, the 32M bits × 4 I/O × 4 banks chip has a page length of 2048 bits
(defined by CA0 to CA9, CA11). The page length of 2048 is divided into 512 uniquely addressable boundary
segments (4 bits each). A 4 bits burst operation will occur entirely within one of the 512 groups beginning with the
column address supplied to the device during the read or write command (CA0 to CA9, CA11). The second, third
and fourth access will also occur within this group segment, however, the burst order is a function of the starting
address, and the burst sequence.
A new burst access must not interrupt the previous 4-bit burst operation. The minimum /CAS to /CAS delay is
defined by tCCD, and is a minimum of 2 clocks for read or write cycles.
Posted /CAS
Posted /CAS operation is supported to make command and data bus efficient for sustainable bandwidths in DDR2
SDRAM. In this operation, the DDR2 SDRAM allows a /CAS read or write command to be issued immediately after
the /RAS bank activate command (or any time during the /RAS-/CAS-delay time, tRCD, period). The command is
held for the time of the Additive Latency (AL) before it is issued inside the device. The Read Latency (RL) is
controlled by the sum of AL and the /CAS latency (CL). Therefore if a user chooses to issue a R/W command before
the tRCD (min), then AL (greater than 0) must be written into the EMRS. The Write Latency (WL) is always defined
as RL − 1 (read latency −1) where read latency is defined as the sum of additive latency plus /CAS latency (RL = AL
+ CL).
-1
0
1
2
ACT
READ
3
4
5
6
7
8
9
10
11
12
11
12
/CK
CK
Command
NOP
NOP
WRIT
AL = 2
WL = RL n–1 = 4
CL = 3
DQS, /DQS
> tRCD
=
RL = AL + CL = 5
DQ
out0 out1 out2 out3
in0 in1 in2 in3
> tRAC
=
Read Followed by a Write to the Same Bank
[AL = 2 and CL = 3, RL = (AL + CL) = 5, WL = (RL - 1) = 4]
-1
0
1
2
3
4
5
6
7
8
9
10
/CK
CK
Command
ACT
NOP
AL = 0
READ
NOP
CL = 3
WRIT
NOP
WL = RL n–1 = 2
DQS, /DQS
> tRCD
=
RL = AL + CL = 3
DQ
out0 out1 out2 out3
> tRAC
=
Read Followed by a Write to the Same Bank
[AL = 0 and CL = 3, RL = (AL + CL) = 3, WL = (RL - 1) = 2]
Data Sheet E0705E20 (Ver. 2.0)
38
in0 in1 in2 in3
EDE5116AFSE
Burst Mode Operation
Burst mode operation is used to provide a constant flow of data to memory locations (write cycle), or from memory
locations (read cycle). The parameters that define how the burst mode will operate are burst sequence and burst
length. DDR2 SDRAM supports 4 bits burst and 8bits burst modes only. For 8 bits burst mode, full interleave
address ordering is supported, however, sequential address ordering is nibble based for ease of implementation.
The burst type, either sequential or interleaved, is programmable and defined by the address bit 3 (A3) of the MRS,
which is similar to the DDR-I SDRAM operation. Seamless burst read or write operations are supported.
Unlike DDR-I devices, interruption of a burst read or writes operation is limited to ready by Read or Write by Write at
the boundary of Burst 4. Therefore the burst stop command is not supported on DDR2 SDRAM devices.
[Burst Length and Sequence]
Burst length
4
8
Starting address (A2, A1, A0) Sequential addressing (decimal)
Interleave addressing (decimal)
000
0, 1, 2, 3
0, 1, 2, 3
001
1, 2, 3, 0
1, 0, 3, 2
010
2, 3, 0, 1
2, 3, 0, 1
011
3, 0, 1, 2
3, 2, 1, 0
000
0, 1, 2, 3, 4, 5, 6, 7
0, 1, 2, 3, 4, 5, 6, 7
001
1, 2, 3, 0, 5, 6, 7, 4
1, 0, 3, 2, 5, 4, 7, 6
010
2, 3, 0, 1, 6, 7, 4, 5
2, 3, 0, 1, 6, 7, 4, 5
011
3, 0, 1, 2, 7, 4, 5, 6
3, 2, 1, 0, 7, 6, 5, 4
100
4, 5, 6, 7, 0, 1, 2, 3
4, 5, 6, 7, 0, 1, 2, 3
101
5, 6, 7, 4, 1, 2, 3, 0
5, 4, 7, 6, 1, 0, 3, 2
110
6, 7, 4, 5, 2, 3, 0, 1
6, 7, 4, 5, 2, 3, 0, 1
111
7, 4, 5, 6, 3, 0, 1, 2
7, 6, 5, 4, 3, 2, 1, 0
Note: Page length is a function of I/O organization and column addressing
8M bits × 16 organization (CA0 to CA9); Page Length = 1024 bits
Data Sheet E0705E20 (Ver. 2.0)
39
EDE5116AFSE
Burst Read Command [READ]
The Burst Read command is initiated by having /CS and /CAS low while holding /RAS and /WE high at the rising
edge of the clock. The address inputs determine the starting column address for the burst. The delay from the start
of the command to when the data from the first cell appears on the outputs is equal to the value of the read latency
(RL). The data strobe output (DQS) is driven low 1 clock cycle before valid data (DQ) is driven onto the data bus.
The first bit of the burst is synchronized with the rising edge of the data strobe (DQS). Each subsequent data-out
appears on the DQ pin in phase with the DQS signal in a source synchronous manner.
The RL is equal to an additive latency (AL) plus /CAS latency (CL). The CL is defined by the mode register set
(MRS), similar to the existing SDR and DDR-I SDRAMs. The AL is defined by the extended mode register set
(EMRS).
T0
T1
T2
T3
T4
T5
T6
T7
T8
T7
T8
/CK
CK
Command
READ
NOP
<tDQSCK
=
DQS, /DQS
CL = 3
RL = 3
DQ
out0 out1 out2 out3
Burst Read Operation (RL = 3, BL = 4 (AL = 0 and CL = 3))
T0
T1
T2
T3
T4
T5
T6
/CK
CK
Command
READ
NOP
<tDQSCK
=
DQS, /DQS
CL = 3
RL = 3
DQ
out0 out1 out2 out3 out4 out5 out6 out7
Burst Read Operation (RL = 3, BL = 8 (AL = 0 and CL = 3))
Data Sheet E0705E20 (Ver. 2.0)
40
EDE5116AFSE
T0
T1
T2
T3
T4
T5
T6
T7
T8
/CK
CK
Command
Posted
READ
NOP
<tDQSCK
=
DQS, /DQS
AL = 2
CL = 3
RL = 5
out0 out1 out2 out3
DQ
Burst Read Operation (RL = 5, BL = 4 (AL = 2, CL = 3))
T0
T1
T3
T4
T5
T6
T7
T8
T9
/CK
CK
Command
Posted
READ
NOP
Posted
WRIT
NOP
NOP
tRTW (Read to Write = 4 clocks)
DQS, /DQS
RL = 5
WL = RL - 1 = 4
out0 out1 out2 out3
DQ
in0
in1
in2
in3
Burst Read Followed by Burst Write (RL = 5, WL = RL-1 = 4, BL = 4)
The minimum time from the burst read command to the burst write command is defined by a read-to-write-turnaround-time, which is 4 clocks.
T0
T1
T2
T3
T4
T5
T6
T7
T8
/CK
CK
Command
Posted
READ
NOP
A
Posted
READ
NOP
B
DQS, /DQS
AL = 2
CL = 3
RL = 5
out
A0
DQ
out
A1
out
A2
Seamless Burst Read Operation (RL = 5, AL = 2, and CL = 3)
Data Sheet E0705E20 (Ver. 2.0)
41
out
A3
out
B0
out
B1
out
B2
EDE5116AFSE
Enabling a read command at every other clock supports the seamless burst read operation. This operation is
allowed regardless of same or different banks as long as the banks are activated.
T0
T1
T2
READ
NOP
READ
T3
T4
T5
T6
T7
T8
T9
T10
T11
/CK
CK
Command
A
NOP
B
DQS, /DQS
RL = 4
out
A0
DQ
out
A1
out
A2
out
A3
out
B0
out out
B1 B2
out
B3
out
B4
out
B5
out
B6
out
B7
Burst interrupt is only
allowed at this timing.
Burst Read Interrupt by Read
Notes :1. Read burst interrupt function is only allowed on burst of 8. burst interrupt of 4 is prohibited.
2. Read burst of 8 can only be interrupted by another read command. Read burst interruption by write
command or precharge command is prohibited.
3. Read burst interrupt must occur exactly two clocks after previous read command. any other read burst
interrupt timings are prohibited.
4. Read burst interruption is allowed to any bank inside DRAM.
5. Read burst with auto precharge enabled is not allowed to interrupt.
6. Read burst interruption is allowed by another read with auto precharge command.
7. All command timings are referenced to burst length set in the mode register. They are not referenced to
actual burst. For example, minimum read to precharge timing is AL + BL/2 where BL is the burst length
set in the mode register and not the actual burst (which is shorter because of interrupt).
Data Sheet E0705E20 (Ver. 2.0)
42
EDE5116AFSE
Burst Write Command [WRIT]
The Burst Write command is initiated by having /CS, /CAS and /WE low while holding /RAS high at the rising edge of
the clock. The address inputs determine the starting column address. Write latency (WL) is defined by a read
latency (RL) minus one and is equal to (AL + CL −1). A data strobe signal (DQS) should be driven low (preamble)
one clock prior to the WL. The first data bit of the burst cycle must be applied to the DQ pins at the first rising edge
of the DQS following the preamble. The tDQSS specification must be satisfied for write cycles. The subsequent
burst bit data are issued on successive edges of the DQS until the burst length of 4 is completed. When the burst
has finished, any additional data supplied to the DQ pins will be ignored. The DQ Signal is ignored after the burst
write operation is complete. The time from the completion of the burst write to bank precharge is the write recovery
time (tWR).
T0
T1
T2
T3
T4
T5
T6
T7
T9
/CK
CK
Command
WRIT
NOP
PRE
NOP
ACT
Completion of
the Burst Write
<tDQSS
=
DQS, /DQS
>tWR
=
WL = RL –1 = 2
in0
DQ
in1
in2
>tRP
=
in3
Burst Write Operation (RL = 3, WL = 2, BL = 4 tWR = 2 (AL=0, CL=3))
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T11
/CK
CK
Command
WRIT
PRE
NOP
NOP
Completion of
the Burst Write
<tDQSS
=
DQS, /DQS
>tWR
=
WL = RL –1 = 2
DQ
in0
in1
in2
in3
in4
in5
in6
in7
Burst Write Operation (RL = 3, WL = 2, BL = 8 (AL=0, CL=3))
Data Sheet E0705E20 (Ver. 2.0)
43
>tRP
=
ACT
EDE5116AFSE
T0
T1
T2
T3
T4
T5
T6
T7
T9
/CK
CK
Posted
WRIT
Command
NOP
PRE
Completion of
the Burst Write
<tDQSS
=
DQS, /DQS
>tWR
=
WL = RL −1 = 4
in0
DQ
in1
in2
in3
Burst Write Operation (RL = 5, WL = 4, BL = 4 tWR = 3 (AL=2, CL=3))
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
/CK
CK
Write to Read = CL - 1 + BL/2 + tWTR (2) = 6
Command
Posted
READ
NOP
NOP
DQS, /DQS
CL = 3
AL = 2
WL = RL –1 = 4
RL = 5
>tWTR
=
in0
DQ
in1
in2
in3
out0
out1
Burst Write Followed by Burst Read (RL = 5, BL = 4, WL = 4, tWTR = 2 (AL=2, CL=3))
The minimum number of clock from the burst write command to the burst read command is CL - 1 + BL/2 + a write
to-read-turn-around-time (tWTR). This tWTR is not a write recovery time (tWR) but the time required to transfer the
4bit write data from the input buffer into sense amplifiers in the array.
T0
T1
T2
T3
T4
T5
T6
T7
T8
/CK
CK
Command
Posted
WRIT
A
NOP
Posted
WRIT
B
NOP
DQS, /DQS
WL = RL − 1 = 4
in
A0
DQ
in
A1
in
A2
in
A3
in
B0
in
B1
in
B2
in
B3
Seamless Burst Write Operation (RL = 5, WL = 4, BL = 4)
Enabling a write command every other clock supports the seamless burst write operation. This operation is allowed
regardless of same or different banks as long as the banks are activated.
Data Sheet E0705E20 (Ver. 2.0)
44
EDE5116AFSE
T0
T1
T2
WRIT
NOP
WRIT
T3
T4
T5
T6
T7
T8
T9
T10
T11
/CK
CK
Command
A
NOP
B
DQS, /DQS
WL = 3
DQ
in in in in
A0 A1 A2 A3
in
B0
in in in in in in
B1 B2 B3 B4 B5 B6
in
B7
Burst interrupt is only
allowed at this timing.
Write Interrupt by Write (WL = 3, BL = 8)
Notes :1. Write burst interrupt function is only allowed on burst of 8. Burst interrupt of 4 is prohibited.
2. Write burst of 8 can only be interrupted by another write command. Write burst interruption by read
command or precharge command is prohibited.
3. Write burst interrupt must occur exactly two clocks after previous write command. Any other write burst
interrupt timings are prohibited.
4. Write burst interruption is allowed to any bank inside DRAM.
5. Write burst with auto precharge enabled is not allowed to interrupt.
6. Write burst interruption is allowed by another write with auto precharge command.
7. All command timings are referenced to burst length set in the mode register. They are not referenced to
actual burst. For example, minimum write to precharge timing is WL+BL/2+tWR where tWR starts with
the rising clock after the un-interrupted burst end and not from the end of actual burst end.
Data Sheet E0705E20 (Ver. 2.0)
45
EDE5116AFSE
Write Data Mask
One write data mask (DM) pin for each 8 data bits (DQ) will be supported on DDR2 SDRAMs, Consistent with the
implementation on DDR-I SDRAMs. It has identical timings on write operations as the data bits, and though used in
a uni-directional manner, is internally loaded identically to data bits to insure matched system timing. DM is not used
during read cycles.
T1
T2
T3
T4
in
in
T5
T6
DQS
/DQS
DQ
in
in
in
in
in
in
DM
Write mask latency = 0
Data Mask Timing
[tDQSS(min.)]
/CK
CK
tWR
Command
WRIT
NOP
WL
tDQSS
DQS, /DQS
DQ
in0
in2 in3
DM
WL
[tDQSS(max.)]
tDQSS
DQS, /DQS
in0
DQ
in2 in3
DM
Data Mask Function, WL = 3, AL = 0 shown
Data Sheet E0705E20 (Ver. 2.0)
46
EDE5116AFSE
Precharge Command [PRE]
The precharge command is used to precharge or close a bank that has been activated. The precharge command is
triggered when /CS, /RAS and /WE are low and /CAS is high at the rising edge of the clock. The precharge
command can be used to precharge each bank independently or all banks simultaneously. Three address bits A10,
BA0 and BA1 are used to define which bank to precharge when the command is issued.
[Bank Selection for Precharge by Address Bits]
A10
BA0
BA1
Precharged Bank(s)
L
L
L
Bank 0 only
L
H
L
Bank 1 only
L
L
H
Bank 2 only
L
H
H
Bank 3 only
H
×
×
All banks 0 to 3
Remark: H: VIH, L: VIL, ×: VIH or VIL
Burst Read Operation Followed by Precharge
Minimum read to precharge command spacing to the same bank = AL + BL/2 clocks
For the earliest possible precharge, the precharge command may be issued on the rising edge that is
“Additive latency (AL) + BL/2 clocks” after a Read command. A new bank active (command) may be issued to the
same bank after the RAS precharge time (tRP). A precharge command cannot be issued until tRAS is satisfied.
/CK
T0
T1
T2
T3
T4
T5
T6
T7
T8
CK
Command
Posted
READ
NOP
PRE
ACT
NOP
NOP
AL + 2 clocks
DQS, /DQS
AL = 1
> tRP
=
CL = 3
RL = 4
out0
DQ
> tRAS
=
out1
out2
out3
CL = 3
Burst Read Operation Followed by Precharge (RL = 4, BL = 4 (AL=1, CL=3))
/CK
T0
T1
T2
T3
T4
T5
T6
T7
T8
CK
Command
Posted
READ
NOP
ACT
NOP
PRE
AL + 2 clocks
DQS, /DQS
AL = 2
> tRP
=
CL = 3
RL = 5
DQ
out0
> tRAS
=
out1
out2
out3
CL = 3
Burst Read Operation Followed by Precharge (RL = 5, BL = 4 (AL=2, CL=3))
Data Sheet E0705E20 (Ver. 2.0)
47
NOP
EDE5116AFSE
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
/CK
CK
Command
Posted
READ
NOP
NOP
PRE
NOP
ACT
AL + BL/2 Clocks
DQS, /DQS
>t
= RP
CL = 4
AL = 2
RL = 6
out0
DQ
out1
out2
out3
out4
>t
= RAS(min.)
Burst Read Operation Followed by Precharge (RL = 6 (AL=2, CL=4, BL=8))
Data Sheet E0705E20 (Ver. 2.0)
48
out5
out6
out7
EDE5116AFSE
Burst Write followed by Precharge
Minimum Write to Precharge Command spacing to the same bank = WL + BL/2 clocks + tWR
For write cycles, a delay must be satisfied from the completion of the last burst write cycle until the precharge
command can be issued. This delay is known as a write recovery time (tWR) referenced from the completion of the
burst write to the precharge command. No precharge command should be issued prior to the tWR delay, as DDR2
SDRAM allows the burst interrupt operation only Read by Read or Write by Write at the boundary of burst 4.
T0
T1
T2
T3
T4
T5
T6
T7
T8
/CK
CK
Command
Posted
WRIT
NOP
PRE
>
= tWR
DQS, /DQS
WL = 3
in0
DQ
in1
in2
in3
Completion of
the Burst Write
Burst Write Followed by Precharge (WL = (RL-1) =3)
T0
T1
T2
T3
T4
T5
T6
T7
T9
/CK
CK
Command
Posted
WRIT
NOP
PRE
> tWR
=
DQS, /DQS
WL = 4
in0
DQ
in1
in2
in3
Completion of
the Burst Write
Burst Write Followed by Precharge (WL = (RL-1) = 4)
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T11
/CK
CK
Command
Posted
WRIT
NOP
PRE
> tWR
=
DQS, /DQS
WL = 4
DQ
in0
in1
in2
in3
in4
in5
in6
in7
Completion of
the Burst Write
Burst Write Followed by Precharge (WL = (RL-1) = 4,BL= 8)
Data Sheet E0705E20 (Ver. 2.0)
49
EDE5116AFSE
Auto Precharge Operation
Before a new row in an active bank can be opened, the active bank must be precharged using either the precharge
command or the auto-precharge function. When a read or a write command is given to the DDR2 SDRAM, the /CAS
timing accepts one extra address, column address A10, to allow the active bank to automatically begin precharge at
the earliest possible moment during the burst read or write cycle. If A10 is low when the read or write Command is
issued, then normal read or write burst operation is executed and the bank remains active at the completion of the
burst sequence. If A10 is high when the Read or Write Command is issued, then the auto-precharge function is
engaged. During auto-precharge, a read Command will execute as normal with the exception that the active bank
will begin to precharge on the rising edge which is /CAS latency (CL) clock cycles before the end of the read burst.
Auto-precharge can also be implemented during Write commands. The precharge operation engaged by the Auto
precharge command will not begin until the last data of the burst write sequence is properly stored in the memory
array.
This feature allows the precharge operation to be partially or completely hidden during burst read cycles (dependent
upon /CAS latency) thus improving system performance for random data access. The /RAS lockout circuit internally
delays the Precharge operation until the array restore operation has been completed so that the auto precharge
command may be issued with any read or write command.
Burst Read with Auto Precharge [READA]
If A10 is high when a Read Command is issued, the Read with Auto-Precharge function is engaged. The DDR2
SDRAM starts an auto Precharge operation on the rising edge which is (AL + BL/2) cycles later from the read with
AP command when tRAS (min) is satisfied. If tRAS (min.) is not satisfied at the edge, the start point of autoprecharge operation will be delayed until tRAS (min.) is satisfied. A new bank active (command) may be issued to
the same bank if the following two conditions are satisfied simultaneously.
(1) The /RAS precharge time (tRP) has been satisfied from the clock at which the auto precharge begins.
(2) The /RAS cycle time (tRC) from the previous bank activation has been satisfied.
T0
T1
T2
T3
T4
T5
T6
T7
T8
/CK
CK
A10 = 1
Command
Posted
READ
NOP
ACT
> tRAS(min.)
=
DQS, /DQS
> tRP
=
AL = 2
CL = 3
RL = 5
out0
DQ
out1
out2
out3
CL = 3
>
= tRC
Auto precharge begins
Burst Read with Auto Precharge Followed by an Activation to the Same Bank (tRC limit)
(RL = 5, BL = 4 (AL = 2, CL = 3, internal tRCD = 3))
Data Sheet E0705E20 (Ver. 2.0)
50
EDE5116AFSE
T-1
T0
T1
T2
T3
T4
T5
T6
T7
T8
/CK
CK
A10 = 1
Posted
READ
Command
NOP
ACT
> tRAS(min.)
=
DQS, /DQS
> tRP
=
AL = 2
CL = 3
RL = 5
out0
DQ
out1
out2
out3
CL = 3
>
= tRC
Auto precharge begins
Burst Read with Auto Precharge Followed by an Activation to the Same Bank (tRAS lockout case)
(RL = 5, BL = 4 (AL = 2, CL = 3, internal tRCD = 3))
T0
T1
T2
T3
T4
T5
T6
T7
T8
/CK
CK
A10 = 1
Command
Posted
READ
ACT
NOP
NOP
>
= tRAS(min.)
DQS, /DQS
> tRP
=
AL = 2
CL = 3
RL = 5
out0
DQ
out1
out2
out3
CL = 3
> tRC
=
Auto precharge begins
Burst Read with Auto Precharge Followed by an Activation to the Same Bank (tRP limit)
(RL = 5, BL = 4 (AL = 2, CL = 3, internal tRCD = 3)
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
/CK
CK
A10 = 1
Command
NOP
READ
ACT
≥tRAS (min.)
DQS, /DQS
AL = 2
CL = 3
≥tRP
RL = 5
out0 out1 out2 out3 out4 out5 out6 out7
DQ
≥tRC
Auto Precharge begins
Burst Read with Auto Precharge Followed by an Activation to the Same Bank
(RL = 5, BL = 8 (AL = 2, CL = 3)
Data Sheet E0705E20 (Ver. 2.0)
51
EDE5116AFSE
Burst Write with Auto Precharge [WRITA]
If A10 is high when a write command is issued, the Write with auto-precharge function is engaged. The DDR2
SDRAM automatically begins precharge operation after the completion of the burst writes plus write recovery time
(tWR). The bank undergoing auto-precharge from the completion of the write burst may be reactivated if the
following two conditions are satisfied.
(1) The data-in to bank activate delay time (tWR + tRP) has been satisfied.
(2) The /RAS cycle time (tRC) from the previous bank activation has been satisfied.
T0
T1
T2
T3
T4
T5
T6
T7
T12
/CK
CK
Command
A10 = 1
Posted
WRIT
NOP
ACT
DQS, /DQS
> tWR
=
WL = RL –1 = 2
in0
DQ
in1
in2
> tRP
=
in3
> tRC
=
Completion of the Burst Write
Auto Precharge Begins
Burst Write with Auto-Precharge (tRC Limit) (WL = 2, tWR =2, tRP=3)
T0
T3
T4
T5
T6
T7
T8
T9
T10
/CK
CK
Command
A10 = 1
Posted
WRIT
NOP
NOP
ACT
DQS, /DQS
> tWR
=
WL = RL –1 = 4
in0
DQ
in1
in2
in3
> tRC
=
Completion of the Burst Write
Auto Precharge Begins
Burst Write with Auto-Precharge (tWR + tRP) (WL = 4, tWR =2, tRP=3)
Data Sheet E0705E20 (Ver. 2.0)
52
> tRP
=
EDE5116AFSE
T0
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
T13
/CK
CK
A10 = 1
Command
NOP
WRIT
ACT
DQS, /DQS
≥tWR
WL = RL − 1 = 4
in0
DQ
in1
in2
in3
in4
in5
in6
≥tRP
in7
≥tRC
Auto Precharge begins.
Burst Write with Auto Precharge Followed by an Activation to the Same Bank
(WL = 4, BL = 8, tWR = 2, tRP = 3)
Data Sheet E0705E20 (Ver. 2.0)
53
EDE5116AFSE
Refresh Requirements
DDR2 SDRAM requires a refresh of all rows in any rolling 64ms interval. Each refresh is generated in one of two
ways: by an explicit automatic refresh command, or by an internally timed event in self-refresh mode. Dividing the
number of device rows into the rolling 64 ms interval defines the average refresh interval, tREFI, which is a guideline
to controllers for distributed refresh timing.
Automatic Refresh Command [REF]
When /CS, /RAS and /CAS are held low and /WE high at the rising edge of the clock, the chip enters the automatic
refresh mode (REF). All banks of the DDR2 SDRAM must be precharged and idle for a minimum of the precharge
time (tRP) before the auto refresh command (REF) can be applied. An address counter, internal to the device,
supplies the bank address during the refresh cycle. No control of the external address bus is required once this
cycle has started.
When the refresh cycle has completed, all banks of the DDR2 SDRAM will be in the precharged (idle) state. A delay
between the auto refresh command (REF) and the next activate command or subsequent auto refresh command
must be greater than or equal to the auto refresh cycle time (tRFC).
To allow for improved efficiency in scheduling and switching between tasks, some flexibility in the absolute refresh
interval is provided. A maximum of 8 refresh commands can be posted to any given DDR2 SDRAM, meaning that
the maximum absolute interval between any refresh command and the next Refresh command is 9 × tREFI.
T0
T1
T2
T3
T15
T7
T8
/CK
CK
VIH
≥ tRP
CKE
Command
PRE
≥ tRFC
≥ tRFC
NOP
REF
REF
Automatic Refresh Command
Data Sheet E0705E20 (Ver. 2.0)
54
NOP
Any
Command
EDE5116AFSE
Self Refresh Command [SELF]
The DDR2 SDRAM device has a built-in timer to accommodate self-refresh operation. The self-refresh command is
defined by having /CS, /RAS, /CAS and CKE held low with /WE high at the rising edge of the clock.
ODT must be turned off before issuing self refresh command, by either driving ODT pin low or using EMRS
command. Once the command is registered, CKE must be held low to keep the device in self-refresh mode.
When the DDR2 SDRAM has entered self refresh mode all of the external signals except CKE, are “don’t care”.
The clock is internally disabled during self-refresh operation to save power. The user may change the external clock
frequency or halt the external clock one clock after Self-Refresh entry is registered, however, the clock must be
restarted and stable before the device can exit self refresh operation. Once self-refresh exit command is registered,
a delay equal or longer than the tXSNR or tXSRD must be satisfied before a valid command can be issued to the
device. CKE must remain high for the entire self-refresh exit period tXSRD for proper operation. NOP or deselect
commands must be registered on each positive clock edge during the self-refresh exit interval. ODT should also be
turned off during tXSRD.
T0
T1
T2
T3
T4
T5
T6
Tm
Tn
tCK
tCH tCL
/CK
CK
≥ tXSNR
tRP*
≥ tXSRD
CKE
tIS
tIS
tAOFD
ODT
tIS
tIS tIH
Comand
SELF
NOP
NOP
NOP
Valid
Notes: 1. Device must be in the “All banks idle” state prior to entering self refresh mode.
2. ODT must be turned off tAOFD before entering self refresh mode, and can be turned on again
when tXSRD timing is satisfied.
3. tXSRD is applied for a read or a read with autoprecharge command.
4. tXSNR is applied for any command except a read or a read with autoprecharge command.
Self Refresh Command
Data Sheet E0705E20 (Ver. 2.0)
55
EDE5116AFSE
Power-Down [PDEN]
Power-down is synchronously entered when CKE is registered low (along with NOP or deselect command). CKE is
not allowed to go low while mode register or extended mode register command time, or read or write operation is in
progress. CKE is allowed to go low while any of other operations such as row activation, precharge or autoprecharge, or auto-refresh is in progress, but power-down IDD spec will not be applied until finishing those
operations. Timing diagrams are shown in the following pages with details for entry into power down.
The DLL should be in a locked state when power-down is entered. Otherwise DLL should be reset after exiting
power-down mode for proper read operation.
If power-down occurs when all banks are idle, this mode is referred to as precharge power-down; if power-down
occurs when there is a row active in any bank, this mode is referred to as active power-down. Entering power-down
deactivates the input and output buffers, excluding CK, /CK, ODT and CKE. Also the DLL is disabled upon entering
precharge power-down or slow exit active power-down, but the DLL is kept enabled during fast exit active powerdown. In power-down mode, CKE low and a stable clock signal must be maintained at the inputs of the DDR2
SDRAM, and ODT should be in a valid state but all other input signals are “Don’t Care”. CKE low must be
maintained until tCKE has been satisfied. Power-down duration is limited by 9 times tREFI of the device.
The power-down state is synchronously exited when CKE is registered high (along with a NOP or deselect
command). CKE high must be maintained until tCKE has been satisfied. A valid, executable command can be
applied with power-down exit latency, tXP, tXARD, or tXARDS, after CKE goes high. Power-down exit latency is
defined at AC Characteristics table of this data sheet.
CK
/CK
tIS tIH
tIS tIH
VALID
NOP
tIH
tIS
tIH
tIS tIH
CKE
Command
VALID
NOP
tCKE
VALID
VALID
tXP, tXARD,
tXARDS
tCKE
tCKE
Enter power-down mode
VIH or VIL
Exit power-down mode
Power Down
Read to Power-Down Entry
T0
T1
T2
Tx
Tx+1
Tx+2
Tx+3
Tx+4
Tx+5
Tx+6
Tx+7
Tx+8
Tx+9
/CK
CK
Command
Read operation starts with a read command and
CKE should be kept high until the end of burst operation.
READ
VIH
CKE
DQS
/DQS
AL + CL
DQ
T0
Command
T1
T2
Tx
out
0
Tx+1
out
1
out
2
Tx+2
out
3
BL=4
Tx+3
READ
Tx+4
Tx+5
Tx+6
Tx+7
Tx+8
Tx+9
CKE should be kept high until the end of burst operation.
VIH
CKE
DQS
/DQS
AL + CL
DQ
out
0
out out
1
2
out
3
out
4
Data Sheet E0705E20 (Ver. 2.0)
56
out out
5
6
out
7
BL=8
EDE5116AFSE
Read with Auto Precharge to Power-Down Entry
T0
T1
T2
Tx
Tx+1
Tx+2
Tx+3
Tx+4
Tx+5
Tx+6
Tx+7
Tx+8
Tx+9
/CK
CK
Command
READ
PRE
AL + BL/2
with tRTP = 7.5ns
and tRAS min. satisfied
BL=4
CKE
CKE should be kept high
until the end of burst operation.
DQS
/DQS
AL + CL
DQ
T0
T1
T2
Tx
out
0
out
1
Tx+1
out
2
Tx+2
out
3
Tx+3
Tx+4
Tx+5
Tx+6
Tx+7
Tx+8
Tx+9
Start internal precharge
Command
READ
BL=8
AL + BL/2
with tRTP = 7.5ns
and tRAS min. satisfied
PRE
CKE should be kept high
until the end of burst operation.
CKE
DQS
/DQS
AL + CL
DQ
out
0
out
1
out
2
out
3
out
4
out out
5
6
out
7
Write to Power-Down Entry
T0
T1
Tm
Tm+1 Tm+2
Tm+3 Tx
Tx+1
Tx+2
Ty
Ty+1
Ty+2
Ty+3
/CK
CK
Command
WRIT
CKE
tWTR
DQS
/DQS
WL
in
0
DQ
T0
Command
T1
Tm
in
1
Tm+1
in
2
in
3
BL=4
Tm+2 Tm+3
Tm+4 Tm+5
Tx
Tx+1
Tx+2
Tx+3
Tx+4
WRIT
CKE
tWTR
DQS
/DQS
DQ
WL
in
0
in
1
in
2
in
3
in
4
in
5
Data Sheet E0705E20 (Ver. 2.0)
57
in
6
in
7
BL=8
EDE5116AFSE
Write with Auto Precharge to Power-Down Entry
T0
T1
Tm
Tm+1
Tm+2
Tm+3
Tx
Tx+1
Tx+2
Tx+3
Tx+4
Tx+5
Tx+6
/CK
CK
Command
WRITA
PRE
CKE
WR*1
DQS
/DQS
WL
in
0
DQ
T0
T1
Tm
in
1
Tm+1
in
2
BL=4
in
3
Tm+2
Tm+3
Tm+4
Tm+5
Tx
Tx+1
Tx+2
Tx+3
Tx+4
/CK
CK
Command
WRITA
CKE
DQS
/DQS
DQ
PRE
WR*1
WL
in
0
in
1
in
2
in
3
in
4
in
5
in
6
in
7
BL=8
Note: 1. WR is programmed through MRS
Data Sheet E0705E20 (Ver. 2.0)
58
EDE5116AFSE
Refresh command to Power-Down Entry
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
/CK
CK
Command
REF
CKE can go to low one clock after an auto-refresh command
CKE
Active command to power down entry
Command
ACT
CKE can go to low one clock after an active command
CKE
Precharge/Precharge all command to power down entry
Command
PRE or
PALL
CKE can go to low one clock after a precharge or precharge all command
CKE
MRS/EMRS command to power down entry
Command
MRS or
EMRS
CKE
tMRD
Data Sheet E0705E20 (Ver. 2.0)
59
EDE5116AFSE
Asynchronous CKE Low Event
DRAM requires CKE to be maintained high for all valid operations as defined in this data sheet. If CKE
asynchronously drops low during any valid operation DRAM is not guaranteed to preserve the contents of array. If
this event occurs, memory controller must satisfy DRAM timing specification tDELAY before turning off the clocks.
Stable clocks must exist at the input of DRAM before CKE is raised high again. DRAM must be fully re-initialized
(steps 4 through 13) as described in initialization sequence. DRAM is ready for normal operation after the
initialization sequence. See AC Characteristics table for tDELAY specification
Stable clocks
tCK
/CK
CK
tDELAY
CKE
CKE asynchronously
drops low
Clocks can be
turned off after
this point
Data Sheet E0705E20 (Ver. 2.0)
60
EDE5116AFSE
Input Clock Frequency Change during Precharge Power Down
DDR2 SDRAM input clock frequency can be changed under following condition:
DDR2 SDRAM is in precharged power down mode. ODT must be turned off and CKE must be at logic low level.
A minimum of 2 clocks must be waited after CKE goes low before clock frequency may change. SDRAM input clock
frequency is allowed to change only within minimum and maximum operating frequency specified for the particular
speed grade. During input clock frequency change, ODT and CKE must be held at stable low levels.
Once input clock frequency is changed, stable new clocks must be provided to DRAM before precharge power down
may be exited and DLL must be RESET via EMRS after precharge power down exit. Depending on new clock
frequency an additional MRS command may need to be issued to appropriately set the WR, CL and soon. During
DLL relock period, ODT must remain off. After the DLL lock time, the DRAM is ready to operate with new clock
frequency.
Clock Frequency Change in Precharge Power Down Mode
T0
T1
T2
NOP
NOP
T4
Tx
Tx+1
Ty
Ty+1
Ty+2 Ty+3
Ty+4
Tz
/CK
CK
Command
CKE
NOP
NOP
Frequency change
occurs here
DLL
RESET
NOP
Valid
200 clocks
ODT
tRP
tXP
tAOFD
ODT is off during
DLL RESET
Minmum 2 clocks
required before
changing frequency
Stable new clock
before power down exit
Burst Interruption
Interruption of a burst read or write cycle is prohibited.
No Operation Command [NOP]
The no operation command should be used in cases when the DDR2 SDRAM is in an idle or a wait state. The
purpose of the no operation command is to prevent the DDR2 SDRAM from registering any unwanted commands
between operations. A no operation command is registered when /CS is low with /RAS, /CAS, and /WE held high at
the rising edge of the clock. A no operation command will not terminate a previous operation that is still executing,
such as a burst read or write cycle.
Deselect Command [DESL]
The deselect command performs the same function as a no operation command. Deselect Command occurs when
/CS is brought high at the rising edge of the clock, the /RAS, /CAS, and /WE signals become don’t cares.
Data Sheet E0705E20 (Ver. 2.0)
61
EDE5116AFSE
Package Drawing
84-ball FBGA (µBGA)
Solder ball: Lead free (Sn-Ag-Cu)
Unit: mm
11.0 ± 0.1
0.2 S B
13.0 ± 0.1
INDEX MARK
0.2 S A
0.2 S
1.12 max.
S
0.1 S
0.35 ± 0.05
B
φ0.12 M S A B
0.8
84-φ0.45 ± 0.05
11.2
A
INDEX MARK
1.6
0.8
6.4
ECA-TS2-0138-02
Data Sheet E0705E20 (Ver. 2.0)
62
EDE5116AFSE
Recommended Soldering Conditions
Please consult with our sales offices for soldering conditions of the EDE5116AFSE.
Type of Surface Mount Device
EDE5116AFSE: 84-ball FBGA (µBGA) < Lead free (Sn-Ag-Cu) >
Data Sheet E0705E20 (Ver. 2.0)
63
EDE5116AFSE
NOTES FOR CMOS DEVICES
1
PRECAUTION AGAINST ESD FOR MOS DEVICES
Exposing the MOS devices to a strong electric field can cause destruction of the gate
oxide and ultimately degrade the MOS devices operation. Steps must be taken to stop
generation of static electricity as much as possible, and quickly dissipate it, when once
it has occurred. Environmental control must be adequate. When it is dry, humidifier
should be used. It is recommended to avoid using insulators that easily build static
electricity. MOS devices must be stored and transported in an anti-static container,
static shielding bag or conductive material. All test and measurement tools including
work bench and floor should be grounded. The operator should be grounded using
wrist strap. MOS devices must not be touched with bare hands. Similar precautions
need to be taken for PW boards with semiconductor MOS devices on it.
2
HANDLING OF UNUSED INPUT PINS FOR CMOS DEVICES
No connection for CMOS devices input pins can be a cause of malfunction. If no
connection is provided to the input pins, it is possible that an internal input level may be
generated due to noise, etc., hence causing malfunction. CMOS devices behave
differently than Bipolar or NMOS devices. Input levels of CMOS devices must be fixed
high or low by using a pull-up or pull-down circuitry. Each unused pin should be connected
to VDD or GND with a resistor, if it is considered to have a possibility of being an output
pin. The unused pins must be handled in accordance with the related specifications.
3
STATUS BEFORE INITIALIZATION OF MOS DEVICES
Power-on does not necessarily define initial status of MOS devices. Production process
of MOS does not define the initial operation status of the device. Immediately after the
power source is turned ON, the MOS devices with reset function have not yet been
initialized. Hence, power-on does not guarantee output pin levels, I/O settings or
contents of registers. MOS devices are not initialized until the reset signal is received.
Reset operation must be executed immediately after power-on for MOS devices having
reset function.
CME0107
Data Sheet E0705E20 (Ver. 2.0)
64
EDE5116AFSE
µBGA is a registered trademark of Tessera, Inc.
All other trademarks are the intellectual property of their respective owners.
The information in this document is subject to change without notice. Before using this document, confirm that this is the latest version.
No part of this document may be copied or reproduced in any form or by any means without the prior
written consent of Elpida Memory, Inc.
Elpida Memory, Inc. does not assume any liability for infringement of any intellectual property rights
(including but not limited to patents, copyrights, and circuit layout licenses) of Elpida Memory, Inc. or
third parties by or arising from the use of the products or information listed in this document. No license,
express, implied or otherwise, is granted under any patents, copyrights or other intellectual property
rights of Elpida Memory, Inc. or others.
Descriptions of circuits, software and other related information in this document are provided for
illustrative purposes in semiconductor product operation and application examples. The incorporation of
these circuits, software and information in the design of the customer's equipment shall be done under
the full responsibility of the customer. Elpida Memory, Inc. assumes no responsibility for any losses
incurred by customers or third parties arising from the use of these circuits, software and information.
[Product applications]
Elpida Memory, Inc. makes every attempt to ensure that its products are of high quality and reliability.
However, users are instructed to contact Elpida Memory's sales office before using the product in
aerospace, aeronautics, nuclear power, combustion control, transportation, traffic, safety equipment,
medical equipment for life support, or other such application in which especially high quality and
reliability is demanded or where its failure or malfunction may directly threaten human life or cause risk
of bodily injury.
[Product usage]
Design your application so that the product is used within the ranges and conditions guaranteed by
Elpida Memory, Inc., including the maximum ratings, operating supply voltage range, heat radiation
characteristics, installation conditions and other related characteristics. Elpida Memory, Inc. bears no
responsibility for failure or damage when the product is used beyond the guaranteed ranges and
conditions. Even within the guaranteed ranges and conditions, consider normally foreseeable failure
rates or failure modes in semiconductor devices and employ systemic measures such as fail-safes, so
that the equipment incorporating Elpida Memory, Inc. products does not cause bodily injury, fire or other
consequential damage due to the operation of the Elpida Memory, Inc. product.
[Usage environment]
This product is not designed to be resistant to electromagnetic waves or radiation. This product must be
used in a non-condensing environment.
If you export the products or technology described in this document that are controlled by the Foreign
Exchange and Foreign Trade Law of Japan, you must follow the necessary procedures in accordance
with the relevant laws and regulations of Japan. Also, if you export products/technology controlled by
U.S. export control regulations, or another country's export control laws or regulations, you must follow
the necessary procedures in accordance with such laws or regulations.
If these products/technology are sold, leased, or transferred to a third party, or a third party is granted
license to use these products, that third party must be made aware that they are responsible for
compliance with the relevant laws and regulations.
M01E0107
Data Sheet E0705E20 (Ver. 2.0)
65