EXAR ST16C550IJ44

ST16C550
UART WITH 16-BYTE FIFO’s
September 2003
GENERAL DESCRIPTION
D4
D3
D2
D1
D0
N.C.
VCC
-RI
-CD
-DSR
-CTS
6
5
4
3
2
1
44
43
42
41
40
PLCC Package
D5
7
39
RESET
D6
8
38
-OP1
D7
9
37
-DTR
RCLK
10
36
-RTS
RX
11
35
-OP2
N.C.
12
34
N.C.
TX
13
33
INT
CS0
14
32
-RXRDY
CS1
15
31
A0
-CS2
16
30
A1
-BAUDOUT
17
29
A2
18
19
20
21
22
23
24
25
26
27
28
XTAL2
-IOW
IOW
GND
N.C.
-IOR
IOR
-DDIS
-TXRDY
-AS
ST16C550CJ44
XTAL1
The ST16C550 (550) is a universal asynchronous receiver and transmitter with 16 byte transmit and receive
FIFO. It operates at 2.97 to 5.5 volts. A programmable
baud rate generator can select transmit and receive
clock rates from 50 bps to 1.5 Mbps.
The ST16C550 is an improved version of the NS16C550
UART with higher operating speed and lower access
time. The ST16C550 on board status registers provides
the error conditions, type and status of the transfer
operation being performed. Included is complete MODEM control capability, and a processor interrupt
system that may be software tailored to the user’s
requirements. The ST16C550 provides internal loopback capability for on board diagnostic testing.
The ST16C550 is available in 40 pin PDIP, 44 pin PLCC,
and 48 pin TQFP packages. It is fabricated in an
advanced CMOS process to achieve low drain power
and high speed requirements.
FEATURES
• Pin to pin and functionally compatible to the Industry
Standard 16C550
• 2.97 to 5.5 volt operation
• 24MHz clock operation at 5V
• 16MHz clock operation at 3.3V
• 16 byte transmit FIFO
• 16 byte receive FIFO with error flags
• Full duplex operation
• Transmit and receive control
• Four selectable receive FIFO interrupt trigger levels
• Standard modem interface
• Compatible with ST16C450
• Low operating current ( 1.2mA typ.)
ORDERING INFORMATION
Part number
Package
ST16C550CP40
ST16C550CJ44
ST16C550CQ48
ST16C550IP40
ST16C550IJ44
ST16C550IQ48
40-Lead
44-Lead
48-Lead
40-Lead
44-Lead
48-Lead
PDIP
PLCC
TQFP
PDIP
PLCC
TQFP
Operating temperature
Device Status
0° C to + 70° C
0° C to + 70° C
0° C to + 70° C
-40° C to + 85° C
-40° C to + 85° C
-40° C to + 85° C
Active. See the ST16C550CQ48 for new designs.
Active
Active
Active. See the ST16C550IQ48 for new designs.
Active
Active
Rev. 4.30
EXAR Corporation, 48720 Kato Road, Fremont, CA 94538 • (510) 668-7000 • FAX (510) 668-7017
ST16C550
Figure 1, PACKAGE DESCRIPTION, ST16C550
N.C.
1
36
N.C.
D5
2
35
RESET
D6
3
34
-OP1
D7
4
33
-DTR
RCLK
5
N.C.
6
ST16C550CQ48
32
-RTS
31
-OP2
RX
7
30
INT
D0
1
40
VCC
D1
2
39
-RI
D2
3
38
-CD
D3
4
37
-DSR
D4
5
36
-CTS
D5
6
35
RESET
D6
7
34
-OP1
33
-DTR
32
-RTS
31
-OP2
30
INT
D7
8
RCLK
9
ST16C550CP40
-CTS
N.C.
37
-DSR
-CD
-RI
VCC
D0
D1
40 Pin DIP Package
38
39
40
41
42
43
44
D3
D4
D2
45
46
47
48
N.C.
48 Pin TQFP Package
TX
8
29
-RXRDY
RX
10
CS0
9
28
A0
TX
11
CS1
10
27
A1
CS0
12
29
-RXRDY
-CS2
11
26
A2
CS1
13
28
A0
18
19
20
21
22
23
24
-IOR
IOR
N.C.
-DDIS
-TXRDY
-AS
16
-IOW
17
15
XTAL2
IOW
14
GND
13
25
N.C.
12
XTAL1
-BAUDOUT
N.C.
Rev. 4.30
2
-CS2
14
27
A1
-BAUDOUT
15
26
A2
XTAL1
16
25
-AS
XTAL2
17
24
-TXRDY
-IOW
18
23
-DDIS
IOW
19
22
IOR
GND
20
21
-IOR
ST16C550
Inter Connect Bus Lines
&
Control signals
A0-A2
-AS
CS0,CS1
-CS2
Register
Select
Logic
D0-D7
-IOR,IOR
-IOW,IOW
RESET
Data bus
&
Control Logic
Figure 2, BLOCK DIAGRAM
Transmit
FIFO
Registers
Transmit
Shift
Register
TX
Receive
FIFO
Registers
Receive
Shift
Register
RX
-DDIS
Clock
&
Baud Rate
Generator
XTAL1
RCLK
XTAL2
-BAUDOUT
INT
-RXRDY
-TXRDY
Interrupt
Control
Logic
-DTR,-RTS
-OP1,-OP2
Rev. 4.30
3
Modem
Control
Logic
-CTS
-RI
-CD
-DSR
ST16C550
SYMBOL DESCRIPTION
Symbol
40
Pin
44
48
Signal
type
A0
28
31
28
I
Address-0 Select Bit Internal registers address selection.
A1
27
30
27
I
Address-1 Select Bit Internal registers address selection.
A2
26
29
26
I
Address-2 Select Bit Internal registers address selection.
IOR
22
25
20
I
Read data strobe. Its function is the same as -IOR (see IOR), except it is active high. Either an active -IOR or IOR
is required to transfer data from 16C550 to CPU during a
read operation. Connect to logic 0 when using -IOR.
CS0
12
14
9
I
Chip Select-0. Logical 1 on this pin provides the chip select0 function. Connect CS0 to logic 1 if using CS1 or -CS2.
CS1
13
15
10
I
Chip Select-1. Logical 1 on this pin provides the chip select1 function. Connect CS1 to logic 1 if using CS0 or -CS2.
-CS2
14
16
11
I
Chip Select -2. Logical 0 on this pin provides the chip select2 function. Connect to logic 0 if using CS0 or CS1.
IOW
19
21
17
I
Write data strobe. Its function is the same as -IOW (see IOW), but it acts as an active high input signal. Either -IOW
or IOW is required to transfer data from the CPU to
ST16C550 during a write operation. Connect to logic 0 when
using -IOW.
-AS
25
28
24
I
Address Strobe. A logic 1 transition on -AS latches the state
of the chip selects and the register select bits, A0-A2. This
input is used when address and chip selects are not stable
for the duration of a read or write operation, i.e., a microprocessor that needs to de-multiplex the address and data bits.
If not required, the -AS input can be permanently tied to a
logic 0.
D0-D7
1-8
2-9
43-47
2-4
I/O
Data Bus (Bi-directional) - These pins are the eight bit, tristate data bus for transferring information to or from the
controlling CPU. D0 is the least significant bit and the first
data bit in a transmit or receive serial data stream.
18
Pwr
Signal and Power Ground.
GND
20
22
Pin Description
Rev. 4.30
4
ST16C550
SYMBOL DESCRIPTION
Symbol
40
Pin
44
48
Signal
type
Pin Description
-IOR
21
24
19
I
Read data strobe (active low strobe). A logic 0 on this pin
transfers the contents of the ST16C550 data bus to the CPU.
Connect to logic 1 when using IOR.
-IOW
18
20
16
I
Write data strobe (active low strobe). A logic 0 on this pin
transfers the contents of the CPU data bus to the addressed
internal register. Connect to logic 1 when using IOW.
INT
30
33
30
O
Interrupt Request (active high). Interrupts are enabled in the
interrupt enable register (IER), and when an interrupt condition exists. Interrupt conditions include: receiver errors,
available receiver buffer data, transmit buffer empty, or
when a modem status flag is detected.
-RXRDY
29
32
29
O
Receive Ready. When operating in the FIFO mode, one of
two types of DMA signaling can be selected using the FIFO
control register bit-3. When operating in the ST16C450
mode, only DMA mode “0” is allowed. Mode “0” supports
single transfer DMA in which a transfer is made between
CPU bus cycles. Mode “1” supports multi-transfer DMA in
which multiple transfers are made continuously until the
receiver FIFO has been emptied. In DMA mode “0” -RXRDY
is low, when there is at least one character in the receiver
FIFO or receive holding register. In DMA mode “1”, -RXRDY
is low, when the trigger level or the time-out has been
reached.
-TXRDY
24
27
23
O
Transmit Ready. When operating in the FIFO mode, one of
two types of DMA signaling can be selected using the FIFO
control register bit-3. When operating in the ST16C450
mode, only DMA mode “0” is allowed. Mode “0” supports
single transfer DMA in which a transfer is made between
CPU bus cycles. Mode “1” supports multi-transfer DMA in
which multiple transfers are made continuously until the
transmit FIFO has been filled.
-BAUDOUT
15
17
12
O
Baud Rate Generator Output. This pin provides the 16X
clock of the selected data rate from the baud rate generator.
The RCLK pin must be connected externally to -BAUDOUT
when the receiver is operating at the same data rate.
Rev. 4.30
5
ST16C550
SYMBOL DESCRIPTION
Symbol
40
Pin
44
48
Signal
type
Pin Description
-DDIS
23
26
22
O
Drive Disable. This pin goes to a logic 0 when the external
CPU is reading data from the ST16C550. This signal can be
used to disable external transceivers or other logic functions.
-OP1
34
38
34
O
Output-1 (User Defined) - See bit-2 of modem control
register (MCR bit-2).
RESET
35
39
35
I
Reset. (active high) - A logic 1 on this pin will reset the
internal registers and all the outputs. The UART transmitter
output and the receiver input will be disabled during reset
time. (See ST16C550 External Reset Conditions for initialization details.)
RCLK
9
10
5
I
Receive Clock Input. This pin is used as external 16X clock
input to the receiver section. External connection to Baudout pin is required in order to utilize the internal baud
rate generator.
-OP2
31
35
31
O
Output-2 (User Defined). This pin provides the user a
general purpose output. See bit-3 modem control register
(MCR bit-3).
VCC
40
44
42
Pwr
XTAL1
16
18
14
I
Crystal or External Clock Input - Functions as a crystal input
or as an external clock input. A crystal can be connected
between this pin and XTAL2 to form an internal oscillator
circuit. An external 1 MΩ resistor is required between the
XTAL1 and XTAL2 pins (see figure 3). Alternatively, an
external clock can be connected to this pin to provide
custom data rates (Programming Baud Rate Generator
section).
XTAL2
17
19
15
O
Output of the Crystal Oscillator or Buffered Clock - (See also
XTAL1). Crystal oscillator output or buffered clock output.
-CD
38
42
40
I
Carrier Detect (active low) - A logic 0 on this pin indicates
that a carrier has been detected by the modem.
Power Supply Input.
Rev. 4.30
6
ST16C550
SYMBOL DESCRIPTION
Symbol
40
Pin
44
48
Signal
type
Pin Description
-CTS
36
40
38
I
Clear to Send (active low) - A logic 0 on the -CTS pin indicates
the modem or data set is ready to accept transmit data from
the ST16C550. Status can be tested by reading MSR bit-4.
This pin has no effect on the UART’s transmit or receive
operation.
-DSR
37
41
39
I
Data Set Ready (active low) - A logic 0 on this pin indicates
the modem or data set is powered-on and is ready for data
exchange with the UART. This pin has no effect on the
UART’s transmit or receive operation.
-DTR
33
37
33
O
Data Terminal Ready (active low) - A logic 0 on this pin
indicates that the ST16C550 is powered-on and ready. This
pin can be controlled via the modem control register.
Writing a logic 1 to MCR bit-0 will set the -DTR output to
logic 0, enabling the modem. This pin will be a logic 1 after
writing a logic 0 to MCR bit-0, or after a reset. This pin has
no effect on the UART’s transmit or receive operation.
-RI
39
43
41
I
Ring Indicator (active low) - A logic 0 on this pin indicates the
modem has received a ringing signal from the telephone
line. A logic 1 transition on this input pin will generate an
interrupt.
-RTS
32
36
32
O
Request to Send (active low) - A logic 0 on the -RTS pin
indicates the transmitter has data ready and waiting to send.
Writing a logic 1 in the modem control register (MCR bit-1)
will set this pin to a logic 0 indicating data is available. After
a reset this pin will be set to a logic 1. This pin has no effect
on the UART’s transmit or receive operation.
RX
10
11
7
I
Receive Data - This pin provides the serial receive data
input to the ST16C550. A logic 1 indicates no data or an idle
channel. During the local loop-back mode, the RX input pin is
disabled and TX data is internally connected to the UART RX
Input, internally, see figure 12.
TX
11
13
8
O
Transmit Data - This pin provides the serial transmit data
from the ST16C550, the TX signal will be a logic 1 during
reset, idle (no data). During the local loop-back mode, the
TX pin is set to a logic 1 and TX data is internally connected
to the UART RX Input, see figure 12.
Rev. 4.30
7
ST16C550
GENERAL DESCRIPTION
FUNCTIONAL DESCRIPTIONS
The ST16C550 provides serial asynchronous receive
data synchronization, parallel-to-serial and serial-toparallel data conversions for both the transmitter and
receiver sections. These functions are necessary for
converting the serial data stream into parallel data that
is required with digital data systems. Synchronization
for the serial data stream is accomplished by adding
start and stops bits to the transmit data to form a data
character (character orientated protocol). Data integrity is insured by attaching a parity bit to the data
character. The parity bit is checked by the receiver for
any transmission bit errors. The electronic circuitry to
provide all these functions is fairly complex especially
when manufactured on a single integrated silicon
chip. The ST16C550 represents such an integration
with greatly enhanced features. The ST16C550 is
fabricated with an advanced CMOS process.
Internal Registers
The ST16C550 provides 12 internal registers for
monitoring and control. These registers are shown in
Table 3 below. These registers function as data holding registers (THR/RHR), interrupt status and control
registers (IER/ISR), a FIFO control register (FCR),
line status and control registers, (LCR/LSR), modem
status and control registers (MCR/MSR), programmable data rate (clock) control registers (DLL/DLM),
and a user assessable scratchpad register (SPR).
The ST16C550 is an upward solution that provides 16
bytes of transmit and receive FIFO memory, instead
of 1 byte provided in the 16C450. The ST16C550 is
designed to work with high speed modems and shared
network environments, that require fast data processing time. Increased performance is realized in the
ST16C550 by the larger transmit and receive FIFO’s.
This allows the external processor to handle more
networking tasks within a given time. The 4 selectable
levels of FIFO trigger provided for maximum data
throughput performance especially when operating in
a multi-channel environment. The combination of the
above greatly reduces the bandwidth requirement of
the external controlling CPU, increases performance,
and reduces power consumption.
The ST16C550 is capable of operation to 1.5Mbps
with a 24 MHz crystal or external clock input.
With a crystal of 14.7464 MHz and through a software
option, the user can select data rates up to 460.8Kbps
or 921.6Kbps.
Rev. 4.30
8
ST16C550
Table 2, INTERNAL REGISTER DECODE
A2
A1
A0
READ MODE
WRITE MODE
General Register Set (THR/RHR, IER/ISR, MCR/MSR, LCR/LSR, SPR):
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
Receive Holding Register
Interrupt Enable Register
Interrupt Status Register
Line Control Register
Modem Control Register
Line Status Register
Modem Status Register
Scratchpad Register
Transmit Holding Register
Interrupt Enable Register
FIFO Control Register
Line Control Register
Modem Control Register
Reserved
Reserved
Scratchpad Register
Baud Rate Generator Registers (DLL/DLM). Accessible only when LCR bit-7 is set to 1.
0
0
0
0
0
1
LSB of Divisor Latch
MSB of Divisor Latch
LSB of Divisor Latch
MSB of Divisor Latch
FIFO Operation
The 16 byte transmit and receive data FIFO’s are
enabled by the FIFO Control Register (FCR) bit-0.
With 16C550 devices, the user can set the receive
trigger level but not the transmit trigger level. The
receiver FIFO section includes a time-out function to
ensure data is delivered to the external CPU. An
interrupt is generated whenever the Receive Holding
Register (RHR) has not been read following the loading of a character or the receive trigger level has not
been reached.
In this case the ST16C550 FIFO may hold more characters than the programmed trigger level. Following the
removal of a data byte, the user should recheck LSR bit0 for additional characters. A Receive Time Out will not
occur if the receive FIFO is empty. The time out counter
is reset at the center of each stop bit received or each
time the receive holding register (RHR) is read (see
Figure 10, Receive Time-out Interrupt). The actual time
out value is T (Time out length in bits) = 4 X P
(Programmed word length) + 12. To convert the time out
value to a character value, the user has to consider the
complete word length, including data information
length, start bit, parity bit, and the size of stop bit, i.e.,
1X, 1.5X, or 2X bit times.
Time-out Interrupts
When two interrupt conditions have the same priority,
it is important to service these interrupts correctly.
Receive Data Ready and Receive Time Out have the
same interrupt priority (when enabled by IER bit-0).
The receiver issues an interrupt after the number of
characters have reached the programmed trigger level.
Example -A: If the user programs a word length of 7,
with no parity and one stop bit, the time out will be:
T = 4 X 7( programmed word length) +12 = 40 bit times.
The character time will be equal to 40 / 9 = 4.4
characters, or as shown in the fully worked out example:
Rev. 4.30
9
ST16C550
T = [(programmed word length = 7) + (stop bit = 1) +
(start bit = 1) = 9]. 40 (bit times divided by 9) = 4.4
characters.
For internal clock oscillator operation, an industry
standard microprocessor crystal (parallel resonant/ 22
pF load) is connected externally between the XTAL1
and XTAL2 pins, with an external 1 MΩ resistor across
it. Alternatively, an external clock can be connected to
the XTAL1 pin to clock the internal baud rate generator
for standard or custom rates. See figure 3 for crystal
oscillator connection.
Example -B: If the user programs the word length = 7,
with parity and one stop bit, the time out will be:
T = 4 X 7(programmed word length) + 12 = 40 bit times.
Character time = 40 / 10 [ (programmed word length
= 7) + (parity = 1) + (stop bit = 1) + (start bit = 1) = 4
characters.
The generator divides the input 16X clock by any
divisor from 1 to 216 -1. The ST16C550 divides the
basic crystal or external clock by 16. The frequency of
the -BAUDOUT output pin is exactly 16X (16 times) of
the selected baud rate (-BAUDOUT =16 x Baud Rate).
Customized Baud Rates can be achieved by selecting
the proper divisor values for the MSB and LSB sections of baud rate generator.
Programmable Baud Rate Generator
The ST16C550 supports high speed modem technologies that have increased input data rates by
employing data compression schemes. For example
a 33.6Kbps modem that employs data compression
may require a 115.2Kbps input data rate. A 128.0Kbps
ISDN modem that supports data compression may
need an input data rate of 460.8Kbps. The ST16C550
can support a standard data rate of 921.6Kbps.
Programming the Baud Rate Generator Registers
DLM (MSB) and DLL (LSB) provides a user capability
for selecting the desired final baud rate. The example
in Table 3 below shows selectable baud rates when
using a 1.8432 MHz crystal.
The programmable Baud Rate Generator is capable
of accepting an input clock up to 24 MHz, as required
for supporting a 1.5Mbps data rate. The ST16C550 can
be configured for internal or external clock operation.
For custom baud rates, the divisor value can be calculated using the following equation:
Divisor (in decimal) = (XTAL1 clock frequency) / (serial data rate x 16)
Table 3, BAUD RATE GENERATOR PROGRAMMING TABLE (1.8432 MHz CLOCK):
Output
Baud Rate
User
16 x Clock
Divisor
(Decimal)
User
16 x Clock
Divisor
(HEX)
DLM
Program
Value
(HEX)
DLL
Program
Value
(HEX)
50
75
150
300
600
1200
2400
4800
7200
9600
19.2k
38.4k
57.6k
115.2k
2304
1536
768
384
192
96
48
24
16
12
6
3
2
1
900
600
300
180
C0
60
30
18
10
0C
06
03
02
01
09
06
03
01
00
00
00
00
00
00
00
00
00
00
00
00
00
80
C0
60
30
18
10
0C
06
03
02
01
Rev. 4.30
10
ST16C550
DMA Operation
D0-D7. The user optionally compares the received data
to the initial transmitted data for verifying error free
operation of the UART TX/RX circuits.
The ST16C550 FIFO trigger level provides additional
flexibility to the user for block mode operation. The user
can optionally operate the transmit and receive FIFO’s
in the DMA mode (FCR bit-3). The DMA mode affects
the state of the -RXRDY and -TXRDY output pins. The
following tables show this:
In this mode , the receiver and transmitter interrupts are
fully operational. The Modem Control Interrupts are also
operational. The interrupts are still controlled by the
IER.
-RXRDY pin:
Non-DMA mode
1 = FIFO empty
0 = at least 1 byte
in FIFO
DMA mode
0 to 1 transition when FIFO
empties
1 to 0 transition when FIFO
reaches trigger level, or
timeout occurs
-TXRDY pin:
Non-DMA mode
1 = at least 1 byte
in FIFO
0 = FIFO empty
DMA mode
1 = FIFO is full
0 = FIFO has at least 1
empty location
Figure 3, TYPICAL EXTERNAL CRYSTAL OSCILLATOR CONNECTION
Loop-back Mode
The internal loop-back capability allows onboard diagnostics. In the loop-back mode the normal modem
interface pins are disconnected and reconfigured for
loop-back internally. In this mode MSR bits 4-7 are
also disconnected. However, MCR register bits 0-3
can be used for controlling loop-back diagnostic testing. In the loop-back mode -OP1 and -OP2 in the MCR
register (bits 0-1) control the modem -RI and -CD
inputs respectively. MCR signals -DTR and -RTS (bits
0-1) are used to control the modem -CTS and -DSR
inputs respectively. The transmitter output (TX) and the
receiver input (RX) are disconnected from their associated interface pins, and instead are connected together
internally (See Figure 4). The -CTS, -DSR, -CD, and -RI
are disconnected from their normal modem control
inputs pins, and instead are connected internally to DTR, -RTS, -OP1 and -OP2. Loop-back test data is
entered into the transmit holding register via the user
data bus interface, D0-D7. The transmit UART serializes the data and passes the serial data to the receive
UART via the internal loop-back connection. The receive
UART converts the serial data back into parallel data
that is then made available at the user data interface,
XTAL1
XTAL2
R1
0 -1 2 0
(O p tio n a l)
R2
1M
Y1
1 .8 4 3 2 - 2 4 M H z
C1
2 2 -4 7 p F
Rev. 4.30
11
C2
2 2 -4 7 p F
ST16C550
Figure 4, INTERNAL LOOP-BACK MODE DIAGRAM
IN T
-T X R D Y
-R X R D Y
R eceive
S h ift
R eg ister
TX
MCR Bit-4=1
R eceive
F IF O
R eg isters
RX
VCC
-R T S
VCC
Interrupt
Control
Logic
-D D IS
T ra n sm it
S h ift
R eg ister
Modem Control Logic
A 0 -A 2
-A S
C S 0 ,C S 1
-C S 2
T ra n sm it
F IF O
R eg isters
Inter Connect Bus Lines
&
Control signals
-IO R ,IO R
-IO W ,IO W
R E SE T
Register
Select
Logic
D 0 -D 7
Data bus
&
Control Logic
VCC
C lo ck
&
B a u d R a te
G en erato r
-C T S
-D T R
VCC
-D S R
-O P 1
VCC
-R I
-O P 2
Rev. 4.30
12
XTAL2
-BAUDOUT
XTAL1
RCLK
-C D
ST16C550
REGISTER FUNCTIONAL DESCRIPTIONS
The following table delineates the assigned bit functions for the twelve ST16C550 internal registers. The assigned
bit functions are more fully defined in the following paragraphs.
Table 4, ST16C550 INTERNAL REGISTERS
A2 A1 A0
Register
[Default]
Note *2
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
General Register Set
0
0
0
RHR [XX]
bit-7
bit-6
bit-5
bit-4
bit-3
bit-2
bit-1
bit-0
0
0
0
THR [XX]
bit-7
bit-6
bit-5
bit-4
bit-3
bit-2
bit-1
bit-0
0
0
1
IER [00]
0
0
0
0
modem
status
interrupt
receive
line
status
interrupt
transmit
holding
register
receive
holding
register
0
1
0
FCR [00]
RCVR
trigger
(MSB)
RCVR
trigger
(LSB)
0
0
DMA
mode
select
XMIT
FIFO
reset
RCVR
FIFO
reset
FIFO
enable
0
1
0
ISR [01]
FIFO’s
enabled
FIFO’s
enabled
0
0
INT
priority
bit-2
INT
priority
bit-1
INT
priority
bit-0
INT
status
0
1
1
LCR [00]
divisor
latch
enable
set
break
set
parity
even
parity
parity
enable
stop
bits
word
length
bit-1
word
length
bit-0
1
0
0
MCR [00]
0
0
0
loopback
enable
-OP2
-OP1
-RTS
-DTR
1
0
1
LSR [60]
FIFO
data
error
trans.
empty
trans.
holding
empty
break
interrupt
framing
error
parity
error
overrun
error
receive
data
ready
1
1
0
MSR [X0]
CD
RI
DSR
CTS
delta
-CD
delta
-RI
delta
-DSR
delta
-CTS
1
1
1
SPR [FF]
bit-7
bit-6
bit-5
bit-4
bit-3
bit-2
bit-1
bit-0
Baud Rate Generator Divisor Registers. Accessible when LCR bit-7 is set to logic 1. Note 1*
0
0
0
DLL [XX]
bit-7
bit-6
bit-5
bit-4
bit-3
bit-2
bit-1
bit-0
0
0
1
DLM [XX]
bit-15
bit-14
bit-13
bit-12
bit-11
bit-10
bit-9
bit-8
Note *1: The BRG registers are accessible only when LCR bit-7 is set to a logic 1.
Note *2: The value represents the register’s initialized HEX value. An “X” signifies a 4-bit un-initialized nibble.
Rev. 4.30
13
ST16C550
B) FIFO status will also be reflected in the user accessible ISR register when the FIFO trigger level is reached.
Both the ISR register status bit and the interrupt will be
cleared when the FIFO drops below the trigger level.
Transmit and Receive Holding Register
The serial transmitter section consists of an 8-bit
Transmit Hold Register (THR) and Transmit Shift
Register (TSR). The status of the THR is provided in
the Line Status Register (LSR). Writing to the THR
transfers the contents of the data bus (D7-D0) to the
THR, providing that the THR or TSR is empty. The
THR empty flag in the LSR register will be set to a logic
1 when the transmitter is empty or when data is
transferred to the TSR. Note that a write operation can
be performed when the transmit holding register
empty flag is set (logic 0 = at least one byte in FIFO /
THR, logic 1= FIFO/THR empty).
C) The data ready bit (LSR BIT-0) is set as soon as a
character is transferred from the shift register to the
receive FIFO. It is reset when the FIFO is empty.
IER Vs Receive/Transmit FIFO Polled Mode Operation
When FCR BIT-0 equals a logic 1; resetting IER bits
0-3 enables the ST16C550 in the FIFO polled mode of
operation. Since the receiver and transmitter have
separate bits in the LSR either or both can be used in
the polled mode by selecting respective transmit or
receive control bit(s).
The serial receive section also contains an 8-bit
Receive Holding Register, RHR. Receive data is
removed from the ST16C550 and receive FIFO by
reading the RHR register. The receive section provides a mechanism to prevent false starts. On the
falling edge of a start or false start bit, an internal
receiver counter starts counting clocks at 16x clock
rate. After 7 1/2 clocks the start bit time should be
shifted to the center of the start bit. At this time the start
bit is sampled and if it is still a logic 0 it is validated.
Evaluating the start bit in this manner prevents the
receiver from assembling a false character. Receiver
status codes will be posted in the LSR.
A) LSR BIT-0 will be a logic 1 as long as there is one
byte in the receive FIFO.
B) LSR BIT 1-4 will indicate if an overrun error
occurred.
C) LSR BIT-5 will indicate when the transmit FIFO is
empty.
D) LSR BIT-6 will indicate when both the transmit
FIFO and transmit shift register are empty.
Interrupt Enable Register (IER)
The Interrupt Enable Register (IER) masks the interrupts from receiver ready, transmitter empty, line
status and modem status registers. These interrupts
would normally be seen on the ST16C550 INT output
pin.
E) LSR BIT-7 will indicate any FIFO data errors.
IER Vs Receive FIFO Interrupt Mode Operation
IER BIT-0:
Logic 0 = Disable the receiver ready interrupt. (normal
default condition)
Logic 1 = Enable the receiver ready interrupt.
When the receive FIFO (FCR BIT-0 = a logic 1) and
receive interrupts (IER BIT-0 = logic 1) are enabled,
the receive interrupts and register status will reflect
the following:
IER BIT-1:
Logic 0 = Disable the transmitter empty interrupt.
(normal default condition)
Logic 1 = Enable the transmitter empty interrupt.
A) The receive data available interrupts are issued to
the external CPU when the FIFO has reached the
programmed trigger level. It will be cleared when the
FIFO drops below the programmed trigger level.
IER BIT-2:
Logic 0 = Disable the receiver line status interrupt.
(normal default condition)
Logic 1 = Enable the receiver line status interrupt.
Rev. 4.30
14
ST16C550
logic 0) and when there are no characters in the transmit
FIFO or transmit holding register, the -TXRDY pin will be
a logic 0. Once active the -TXRDY pin will go to a logic
1 after the first character is loaded into the transmit
holding register.
IER BIT-3:
Logic 0 = Disable the modem status register interrupt.
(normal default condition)
Logic 1 = Enable the modem status register interrupt.
IER BIT 4-7: Not used and set to “0”.
Receive operation in mode “0”:
When the ST16C550 is in mode “0” (FCR bit-0 = logic
0) or in the FIFO mode (FCR bit-0 = logic 1, FCR bit3 = logic 0) and there is at least one character in the
receive FIFO, the -RXRDY pin will be a logic 0. Once
active the -RXRDY pin will go to a logic 1 when there
are no more characters in the receiver.
FIFO Control Register (FCR)
This register is used to enable the FIFO’s, clear the
FIFO’s, set the transmit/receive FIFO trigger levels,
and select the DMA mode. The DMA, and FIFO
modes are defined as follows:
DMA MODE:
See description and DMA tables on page 11.
Transmit operation in mode “1”:
When the ST16C550 is in FIFO mode ( FCR bit-0 =
logic 1, FCR bit-3 = logic 1 ), the -TXRDY pin will be
a logic 1 when the transmit FIFO is completely full. It
will be a logic 0 if one or more FIFO locations are
empty.
FCR BIT-0:
Logic 0 = Disable the transmit and receive FIFO.
(normal default condition)
Logic 1 = Enable the transmit and receive FIFO. This
bit must be a “1” when other FCR bits are written to or
they will not be programmed.
Receive operation in mode “1”:
When the ST16C550 is in FIFO mode (FCR bit-0 =
logic 1, FCR bit-3 = logic 1) and the trigger level has
been reached, or a Receive Time Out has occurred,
the -RXRDY pin will go to a logic 0. Once activated, it
will go to a logic 1 after there are no more characters
in the FIFO.
FCR BIT-1:
Logic 0 = No FIFO receive reset. (normal default
condition)
Logic 1 = Clears the contents of the receive FIFO and
resets the FIFO counter logic (the receive shift register is not cleared or altered). This bit will return to a
logic 0 after clearing the FIFO.
FCR BIT 4-5: Not used.
FCR BIT-2:
Logic 0 = No FIFO transmit reset. (normal default
condition)
Logic 1 = Clears the contents of the transmit FIFO and
resets the FIFO counter logic (the transmit shift register is not cleared or altered). This bit will return to a
logic 0 after clearing the FIFO.
FCR BIT 6-7: These bits are used to set the trigger level
for the receive FIFO interrupt.
An interrupt is generated when the number of characters
in the FIFO equals the programmed trigger level. However the FIFO will continue to be loaded until it is full.
FCR BIT-3:
Logic 0 = Set DMA mode “0”. (normal default condition)
Logic 1 = Set DMA mode “1.”
Transmit operation in mode “0”:
When the ST16C550 is in the ST16C450 mode
(FIFO’s disabled, FCR bit-0 = logic 0) or in the FIFO
mode (FIFO’s enabled, FCR bit-0 = logic 1, FCR bit-3 =
Rev. 4.30
15
BIT-7
BIT-6
RX FIFO trigger level
0
0
1
1
0
1
0
1
1
4
8
14
ST16C550
Interrupt Status Register (ISR)
The ST16C550 provides four levels of prioritized interrupts to minimize external software interaction. The
Interrupt Status Register (ISR) provides the user with six
interrupt status bits. Performing a read cycle on the ISR
will provide the user with the highest pending interrupt
level to be serviced. No other interrupts are acknowledged until the pending interrupt is serviced. Whenever
the interrupt status register is read, the interrupt status
is cleared. However it should be noted that only the
current pending interrupt is cleared by the read. A lower
level interrupt may be seen after rereading the interrupt
status bits. The Interrupt Source Table 5 (below) shows
the data values (bit 0-3) for the four prioritized interrupt
levels and the interrupt sources associated with each of
these interrupt levels:
Table 5, INTERRUPT SOURCE TABLE
Priority
Level
X
1
2
2
3
4
[ISR]
Bit-3 Bit-2 Bit-1 Bit-0
0
0
0
1
0
0
0
1
1
1
0
0
0
1
0
0
1
0
1
0
0
0
0
0
Source of the interrupt
No interrupt pending
LSR (Receiver Line Status Register)
RXRDY (Received Data Ready)
RXRDY (Receive Data time out)
TXRDY ( Transmitter Holding Register Empty)
MSR (Modem Status Register)
Rev. 4.30
16
ST16C550
ISR BIT-0:
Logic 0 = An interrupt is pending and the ISR contents
may be used as a pointer to the appropriate interrupt
service routine.
Logic 1 = No interrupt pending. (normal default condition)
ISR BIT 1-3: (logic 0 or cleared is the default condition)
These bits indicate the source for a pending interrupt at
interrupt priority levels 1, 2, and 3 (See Interrupt Source
Table).
ISR BIT 6-7: (logic 0 or cleared is the default condition)
These bits are set to a logic 0 when the FIFO is not being
used. They are set to a logic 1 when the FIFO’s are
enabled
The Line Control Register is used to specify the
asynchronous data communication format. The word
length, the number of stop bits, and the parity are
selected by writing the appropriate bits in this register.
LCR BIT 0-1: (logic 0 or cleared is the default condition)
These two bits specify the word length to be transmitted or received.
Word length
0
0
1
1
0
1
0
1
5
6
7
8
Stop bit
length
(Bit time(s))
0
1
1
5,6,7,8
5
6,7,8
1
1-1/2
2
LCR BIT-4:
If the parity bit is enabled with LCR bit-3 set to a logic
1, LCR BIT-4 selects the even or odd parity format.
Logic 0 = ODD Parity is generated by forcing an odd
number of logic 1’s in the transmitted data. The
receiver must be programmed to check the same
format. (normal default condition)
Logic 1 = EVEN Parity is generated by forcing an even
the number of logic 1’s in the transmitted. The receiver
must be programmed to check the same format.
Line Control Register (LCR)
BIT-0
Word length
LCR BIT-3:
Parity or no parity can be selected via this bit.
Logic 0 = No parity (normal default condition)
Logic 1 = A parity bit is generated during the transmission, receiver checks the data and parity for transmission errors.
ISR BIT 4-5: Not used and set to “0”.
BIT-1
BIT-2
LCR BIT-5:
If the parity bit is enabled, LCR BIT-5 selects the
forced parity format.
LCR BIT-5 = logic 0, parity is not forced (normal
default condition)
LCR BIT-5 = logic 1 and LCR BIT-4 = logic 0, parity bit
is forced to a logical 1 for the transmit and receive
data.
LCR BIT-5 = logic 1 and LCR BIT-4 = logic 1, parity bit
is forced to a logical 0 for the transmit and receive
data.
LCR BIT-2: (logic 0 or cleared is the default condition)
The length of stop bit is specified by this bit in
conjunction with the programmed word length.
Rev. 4.30
17
LCR
Bit-5
LCR
Bit-4
LCR
Bit-3
Parity selection
X
0
0
1
1
X
0
1
0
1
0
1
1
1
1
No parity
Odd parity
Even parity
Force parity “1”
Forced “0”
ST16C550
MCR BIT 5-7: Not used and set to “0”.
LCR BIT-6:
When enabled the Break control bit causes a break
condition to be transmitted (the TX output is forced to a
logic 0 state). This condition exists until disabled by
setting LCR bit-6 to a logic 0.
Logic 0 = No TX break condition. (normal default
condition)
Logic 1 = Forces the transmitter output (TX) to a logic
0 for alerting the remote receiver to a line break
condition.
Line Status Register (LSR)
This register provides the status of data transfers
between. the ST16C550 and the CPU.
LSR BIT-0:
Logic 0 = No data in receive holding register or FIFO.
(normal default condition)
Logic 1 = Data has been received and is saved in the
receive holding register or FIFO.
LCR BIT-7:
The internal baud rate counter latch and Enhance
Feature mode enable.
Logic 0 = Divisor latch disabled. (normal default condition)
Logic 1 = Divisor latch and enhanced feature register
enabled.
LSR BIT-1:
Logic 0 = No overrun error. (normal default condition)
Logic 1 = Overrun error. A data overrun error occurred
in the receive shift register. This happens when additional data arrives while the FIFO is full. In this case
the previous data in the shift register is overwritten.
Note that under this condition the data byte in the
receive shift register is not transfer into the FIFO,
therefore the data in the FIFO is not corrupted by the
error.
Modem Control Register (MCR)
This register controls the interface with the modem or
a peripheral device.
MCR BIT-0:
Logic 0 = Force -DTR output to a logic 1. (normal
default condition)
Logic 1 = Force -DTR output to a logic 0.
LSR BIT-2:
Logic 0 = No parity error (normal default condition)
Logic 1 = Parity error. The receive character does not
have correct parity information and is suspect. In the
FIFO mode, this error is associated with the character
at the top of the FIFO.
MCR BIT-1:
Logic 0 = Force -RTS output to a logic 1. (normal
default condition)
Logic 1 = Force -RTS output to a logic 0.
LSR BIT-3:
Logic 0 = No framing error (normal default condition).
Logic 1 = Framing error. The receive character did not
have a valid stop bit(s). In the FIFO mode this error is
associated with the character at the top of the FIFO.
MCR BIT-2:
Logic 0 = Set -OP1 output to a logic 1. (normal default
condition)
Logic 1 = Set -OP1 output to a logic 0.
LSR BIT-4:
Logic 0 = No break condition (normal default condition)
Logic 1 = The receiver received a break signal (RX
was a logic 0 for one character frame time). In the
FIFO mode, only one break character is loaded into
the FIFO.
MCR BIT-3:
Logic 0 = Set -OP2 output to a logic 1. (normal default
condition)
Logic 1 = Set -OP2 output to a logic 0.
MCR BIT-4:
Logic 0 = Disable loop-back mode. (normal default
condition)
Logic 1 = Enable local loop-back mode (diagnostics).
LSR BIT-5:
This bit is the Transmit Holding Register Empty indicator. This bit indicates that the UART is ready to
accept a new character for transmission. In addition,
Rev. 4.30
18
ST16C550
this bit causes the UART to issue an interrupt to CPU
when the THR interrupt enable is set. The THR bit is set
to a logic 1 when a character is transferred from the
transmit holding register into the transmitter shift register. The bit is reset to logic 0 concurrently with the
loading of the transmitter holding register by the CPU.
In the FIFO mode this bit is set when the transmit FIFO
is empty; it is cleared when at least 1 byte is written to
the transmit FIFO.
MSR BIT-2:
Logic 0 = No -RI Change (normal default condition)
Logic 1 = The -RI input to the ST16C550 has changed
from a logic 0 to a logic 1. A modem Status Interrupt
will be generated.
MSR BIT-3:
Logic 0 = No -CD Change (normal default condition)
Logic 1 = Indicates that the -CD input to the has
changed state since the last time it was read. A
modem Status Interrupt will be generated.
LSR BIT-6:
This bit is the Transmit Empty indicator. This bit is set
to a logic 1 whenever the transmit holding register and
the transmit shift register are both empty. It is reset to
logic 0 whenever either the THR or TSR contains a
data character. In the FIFO mode this bit is set to one
whenever the transmit FIFO and transmit shift register
are both empty.
MSR BIT-4:
CTS (active high, logical 1). Normally this bit is the
compliment of the -CTS input. In the loop-back mode,
this bit is equivalent to the RTS bit in the MCR register.
MSR BIT-5:
DSR (active high, logical 1). Normally this bit is the
compliment of the -DSR input. In the loop-back mode,
this bit is equivalent to the DTR bit in the MCR register.
LSR BIT-7:
Logic 0 = No Error (normal default condition)
Logic 1 = At least one parity error, framing error or
break indication is in the current FIFO data. This bit is
cleared when there are no remaining LSR errors in the
RX FIFO.
MSR BIT-6:
RI (active high, logical 1). Normally this bit is the
compliment of the -RI input. In the loop-back mode
this bit is equivalent to the OP1 bit in the MCR register.
Modem Status Register (MSR)
This register provides the current state of the control
interface signals from the modem, or other peripheral
device that the ST16C550 is connected to. Four bits
of this register are used to indicate the changed
information. These bits are set to a logic 1 whenever
a control input from the modem changes state. These
bits are set to a logic 0 whenever the CPU reads this
register.
MSR BIT-7:
CD (active high, logical 1). Normally this bit is the
compliment of the -CD input. In the loop-back mode
this bit is equivalent to the OP2 bit in the MCR register.
Scratchpad Register (SPR)
The ST16C550 provides a temporary data register to
store 8 bits of user information.
MSR BIT-0:
Logic 0 = No -CTS Change (normal default condition)
Logic 1 = The -CTS input to the ST16C550 has
changed state since the last time it was read. A
modem Status Interrupt will be generated.
MSR BIT-1:
Logic 0 = No -DSR Change (normal default condition)
Logic 1 = The -DSR input to the ST16C550 has
changed state since the last time it was read. A
modem Status Interrupt will be generated.
Rev. 4.30
19
ST16C550
ST16C550 EXTERNAL RESET CONDITIONS
REGISTERS
IER
ISR
RESET STATE
FCR
IER BITS 0-7 = logic 0
ISR BIT-0=1, ISR BITS 1-7 = logic
0
BITS 0-7 = logic 0
LSR BITS 0-4 = logic 0,
LSR BITS 5-6 = logic 1 LSR, BIT
7 = logic 0
MSR BITS 0-3 = logic 0,
MSR BITS 4-7 = logic levels of the
input signals
BITS 0-7 = logic 0
SIGNALS
RESET STATE
TX
-OP1
-OP2
-RTS
-DTR
-RXRDY
-TXRDY
INT
Logic 1
Logic 1
Logic 1
Logic 1
Logic 1
Logic 1
Logic 0
Logic 0
LCR, MCR
LSR
MSR
Rev. 4.30
20
ST16C550
AC ELECTRICAL CHARACTERISTICS
TA=0° - 70°C (-40° - +85°C for Industrial grade packages), Vcc=3.3 - 5.0 V ± 10% unless otherwise specified.
Symbol
T1w,T2w
T3w
T4w
T5s
T5h
T6s
T6s'
T6h
T7d
T7w
T7h
T7h'
T8d
T9d
T11d
T12d
T12h
T13d
T13w
T13h
T14d
T15d
T16s
T16h
T17d
T18d
T19d
T20d
T21d
T22d
T23d
T24d
T25d
T26d
T27d
T28d
TR
N
Parameter
Clock pulse duration
Oscillator/Clock frequency
Address strobe width
Address setup time
Address hold time
Address setup time
Address setup time
Chip select hold time
-IOR delay from chip select
-IOR strobe width
Chip select hold time from -IOR
Address hold time
-IOR delay from address
Read cycle delay
-IOR to -DDIS delay
Delay from -IOR to data
Data disable time
-IOW delay from chip select
-IOW strobe width
Chip select hold time from -IOW
-IOW delay from address
Write cycle delay
Data setup time
Data hold time
Delay from -IOW to output
Delay to set interrupt from MODEM
input
Delay to reset interrupt from -IOR
Delay from stop to set interrupt
Delay from -IOR to reset interrupt
Delay from stop to interrupt
Delay from initial INT reset to transmit
start
Delay from -IOW to reset interrupt
Delay from stop to set -RxRdy
Delay from -IOR to reset -RxRdy
Delay from -IOW to set -TxRdy
Delay from start to reset -TxRdy
Reset pulse width
Baud rate devisor
Limits
3.3
Min
Max
17
Limits
5.0
Min
Max
17
50
40
40
35
ns
MHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
40
1
45
45
24
35
1
40
40
24
ns
Rclk
ns
ns
Rclk
40
1
40
40
8
ns
Rclk
ns
ns
Rclk
ns
Rclk
16
35
5
5
5
10
0
10
35
0
5
10
40
24
25
0
5
0
5
0
10
25
0
5
10
30
15
35
25
10
40
0
10
40
20
5
8
10
25
15
10
25
0
10
30
15
5
8
45
1
45
45
8
40
1
Note 1: Applicable only when -AS is tied low.
Rev. 4.30
21
Units
216-1
40
1
216-1
Conditions
see Note 1
see Note 1
100 pF load
100 pF load
100 pF load
100 pF load
100 pF load
ST16C550
ABSOLUTE MAXIMUM RATINGS
Supply range
Voltage at any pin
Operating temperature
Storage temperature
Package dissipation
7 Volts
GND - 0.3 V to VCC +0.3 V
-40° C to +85° C
-65° C to 150° C
500 mW
DC ELECTRICAL CHARACTERISTICS
TA=0° - 70°C (-40° - +85°C for Industrial grade packages), Vcc=3.3 - 5.0 V ± 10% unless otherwise specified.
Symbol
VILCK
VIHCK
VIL
VIH
VOL
VOL
VOH
VOH
IIL
ICL
I CC
CP
Parameter
Clock input low level
Clock input high level
Input low level
Input high level
Output low level on all outputs
Output low level on all outputs
Output high level
Output high level
Input leakage
Clock leakage
Avg power supply current
Input capacitance
Limits
3.3
Min
Max
Limits
5.0
Min
Max
-0.3
2.4
-0.3
2.0
-0.5
3.0
-0.5
2.2
0.6
VCC
0.8
0.6
VCC
0.8
VCC
0.4
0.4
2.4
2.0
±10
±10
1.3
5
Rev. 4.30
22
±10
±10
3
5
Units
V
V
V
V
V
V
V
V
µA
µA
mA
pF
Conditions
IOL= 5 mA
IOL= 4 mA
IOH= -5 mA
IOH= -1 mA
ST16C550
T1w
T2w
EXTERNAL
CLOCK
T3w
-BAUDOUT
1/2 -BAUDOUT
1/3 -BAUDOUT
1/3> -BAUDOUT
X450-CK-1
Clock timing
Rev. 4.30
23
ST16C550
T4w
-A S
T5h
T5s
V a lid
A d d re s s
A 0 -A 2
T6h
T6s
-C S 2
C S 1 -C S 0
V a lid
T7d
T7h
T7w
T8d
-IO R
IO R
T9d
A c tiv e
T11d
T11d
A c tiv e
-D D IS
T12h
T12d
D a ta
D 0 -D 7
X 5 5 0 -R D -1
General Read Timing when using -AS signal
T4w
-AS
T5h
T5s
Valid
Address
A0-A2
T6h
T6s
-CS2
CS1-CS0
Valid
T13d
T14d
-IOW
IOW
T13h
T13w
T15d
Active
T16s
D0-D7
T16h
Data
X550-W D-1
General Write Timing when using -AS signal.
Rev. 4.30
24
ST16C550
V alid
A ddress
A 0-A 2
V alid
A ddress
T 7h'
T 6s'
T 7w
A ctive
-C S
T 7h'
T 6s'
A ctive
T 7w
-IO R
T 9d
A ctive
T 12d
D 0-D 7
T 12h
T 12d
T 12h
D ata
General Read Timing when -AS is tied to GND
V a lid
A d d re ss
A 0 -A 2
V a lid
A d d re ss
T7h'
T 6 s'
-C S
A ctive
A ctive
T13w
-IO W
T15d
T13w
A ctive
T16s
D 0 -D 7
T7h'
T 6 s'
T16h
D a ta
General Write Timing when -AS is tied to GND
Rev. 4.30
25
T16s
T16h
ST16C550
-IOW
IOW
Active
T17d
-RTS
-DTR
Change of state
Change of state
-CD
-CTS
-DSR
Change of state
Change of state
T18d
T18d
INT
Active
Active
Active
T19d
-IOR
IOR
Active
Active
Active
T18d
Change of state
-RI
X450-MD-1
Modem input/output timing
Rev. 4.30
26
ST16C550
START
BIT
RX
STOP
BIT
DATA BITS (5-8)
D0
D1
D2
D3
D4
D5
5 DATA BITS
6 DATA BITS
7 DATA BITS
D6
D7
PARITY
BIT
NEXT
DATA
START
BIT
T20d
Active
INT
T21d
-IOR
IOR
16 BAUD RATE CLOCK
Receive timing
Rev. 4.30
27
X450-RX-1
ST16C550
START
BIT
RX
STOP
BIT
DATA BITS (5-8)
D0
D1
D2
D3
D4
D5
D6
D7
PARITY
BIT
NEXT
DATA
START
BIT
T25d
Active
Data
Ready
-RXRDY
T26d
-IOR
IOR
Active
X550-RX-2
Receive ready timing in non FIFO mode
Rev. 4.30
28
ST16C550
START
BIT
RX
STOP
BIT
DATA BITS (5-8)
D0
D1
D2
D3
D4
D5
D6
D7
PARITY
BIT
First byte
that reaches
the trigger
level
T25d
Active
Data
Ready
-RXRDY
T26d
-IOR
IOR
Active
X550-RX-3
Receive ready timing in FIFO mode
Rev. 4.30
29
ST16C550
S T AR T
B IT
D A T A B IT S (5-8)
D0
TX
STOP
B IT
D1
D2
D3
D4
D5
5 D AT A BIT S
D6
D7
P AR IT Y
B IT
6 D AT A BIT S
7 D AT A BIT S
T 22d
IN T
A ctive T X R eady
T 24d
T 23d
IO W /
-IO W
A ctive
A ctiv e
16 BA U D R A T E C LO C K
Transmit timing
Rev. 4.30
30
ST16C550
START
BIT
TX
STOP
BIT
DATA BITS (5-8)
D0
D1
D2
D3
D4
D5
D6
D7
PARITY
BIT
-IOW
IOW
NEXT
DATA
START
BIT
Active
T28d
BYTE #1
T27d
-TXRDY
Active
Transmitter ready
Transmitter
not ready
X550-TX-2
Transmit ready timing in non FIFO mode
Rev. 4.30
31
ST16C550
START BIT
DATA BITS (5-8)
D0
TX
D1
D2
D3
D4
STOP BIT
D5
D6
5 DATA BITS
D7
PARITY BIT
6 DATA BITS
7 DATA BITS
-IOW
IOW
Active
T28d
D0-D7
BYTE #16
T27d
-TXRDY
FIFO Full
X550-TX-3
Transmit ready timing in FIFO mode
Rev. 4.30
32
ST16C550
PACKAGE OUTLINE DRAWING
44LEAD PLASTIC LEADED CHIP CARRIER
(PLCC)
C
D
Seating Plane
D1
2 1
45° x H1
45° x H2
A2
44
B1
D
D1
B
D3
e
R
D3
A1
A
Note: The control dimension is the inch column
SYMBOL
INCHES
MILLIMETERS
MIN
MAX
MIN
MAX
4.57
A
0.165
0.180
4.19
A1
0.090
0.120
2.29
3.05
A2
0.020
-----
0.51
------
B
0.013
0.021
0.33
0.53
B1
0.026
0.032
0.66
0.81
C
0.008
0.013
0.19
0.32
D
0.685
0.695
17.40
17.65
D1
0.650
0.656
16.51
16.66
D2
0.590
0.630
14.99
16.00
D3
0.500 typ
12.70 typ
e
0.50 BSC
1.27BSC
H1
0.042
0.056
1.07
1.42
H2
0.042
0.048
1.07
1.22
R
0.025
0.045
0.64
1.14
Rev. 4.30
33
D2
ST16C550
PACKAGE OUTLINE DRAWING
48 LEAD THIN QUAD FLAT PACK
(TQFP)
D
D1
36
25
37
24
D1
48
13
1
2
1
B
e
A2
C
A
α
Seating
Plane
A1
L
Note: The control dimension is the millimeter column
SYMBOL
INCHES
MILLIMETERS
MIN
MAX
MIN
MAX
A
0.039
0.047
1.00
1.20
A1
0.002
0.006
0.05
0.15
A2
0.037
0.041
0.95
1.05
B
0.007
0.011
0.17
0.27
C
0.004
0.008
0.09
0.20
D
0.346
0.362
8.80
9.20
D1
0.272
0.280
6.90
7.10
e
0.20 BSC
0.50BSC
L
0.018
0.030
0.45
0.75
α
0°
7°
0°
7°
Rev. 4.30
34
D
ST16C550
EXPLANATION OF DATA SHEET REVISIONS:
FROM
TO
4.20
4.30
CHANGES
Added revision history. Added Device Status to front page.
DATE
Sept 2003
NOTICE
EXAR Corporation reserves the right to make changes to the products contained in this publication in order to
improve design, performance or reliability. EXAR Corporation assumes no responsibility for the use of any circuits
described herein, conveys no license under any patent or other right, and makes no representation that the circuits
are free of patent infringement. Charts and schedules contained here in are only for illustration purposes and may
vary depending upon a user's specific application. While the information in this publication has been carefully
checked; no responsibility, however, is assumed for inaccuracies.
EXAR Corporation does not recommend the use of any of its products in life support applications where the failure
of the product can reasonably be expected to cause failure of the life support system or to significantly affect its
safety or effectiveness. Products are not authorized for use in such applications unless EXAR Corporation receives,
in writing, assurances to its satisfaction that: (a) the risk of injury or damage has been minimized; (b) the user
assumes all such risks; (c) potential liability of EXAR Corporation is adequately protected under the circumstances.
Copyright 2003 EXAR Corporation
Datasheet September 2003
Send your UART technical inquiry with technical details to hotline: [email protected]
Reproduction, in part or whole, without prior written consent of EXAR Corporation is prohibited.
Rev. 4.30
35