PERKINELMER TPS334

Lighting
|
Imaging
|
Telecom
p
Thermopile Infrared Detectors
Thermopile Detector
TPS 334
Standard type for pyrometers and ear thermometers
The TPS 334 thermopile sensor in TO 5 type housing employs a chip of
0.7 x 0.7 mm2 absorber size and a 30 kV thermistor as temperature reference.
The round window opening is equipped with a 5.5 mm longpass (standard)
infrared filter. The sensor shows a flat sensitivity characteristics over the
wavelength.
The TPS 334 can be equipped with a G9 (8..14 mm) filter for precision remote
temperature sensing (TPS 334 G9).
Parameters
TP S
334
typical
S ensitive area
condition
0.7 x 0.7
mm2
absorbi ng area
Window size
2.5
mm
diameter
DC sensitivity
35
V /W
500K BB 5...14µm
R esistance
75
kW
Noise
38
nV /Ö Hz
r.m.s. 300K ,
NEP
1.2
nW/Ö Hz
500K BB 5...14µm
D*
0.6 x108
cmÖ Hz/W 500K BB 5...14µm
1.0
TPS 334
Relative signal output
Right for modification reserved / WS /, 21.5.2001
units
0.8
TC of sensitivity
0.02
%/K
TC of resistance
0.02
%/K
25
ms
-3 dB level
0.6
Time constant
0.4
0.2
1
10
Frequency in Hz
100
S torage temperature
-40
100
°C
non permanent
Operating temperature
-40
100
°C
non permanent
30
kW
25°C
3964
K
25°C /100°C
60
°
at 50% poi nts
Thermistor
resistance
beta
Field of view
Normalized signal in percent
100
TPS 334
80
60
40
20
0
-100 -80 -60 -40 -20 0
20 40 60 80 100
Angle of incidence in degree
Europe:
PerkinElmer Optoelectronics GmbH
Wenzel Jaksch Str 31
Wiesbaden / Germany
Phone +49(0)611 492 0
Fax
+49(0)611 492 170
USA:
PerkinElmer Optoelectronics
2175 Mission Colledge Blvd
Santa Clara, CA 95054
Phone +408 565 0830
Fax
+408 565 0703
Dimensions in mm
Asia:
PerkinElmer Optoelectronics
47, Ayer Rajah Crescent #06-12
Singapore 139947
Phone +65 775 2022
Fax
+65 775 1008
www.perkinelmer.com/opto