DS2442 - 2.2
SR12D
1.2V PRECISION VOLTAGE REFERENCE
The SR12D is a monolithic integrated circuit using the
bandgap principle to provide a precise reference voltage of
1.23V.
This reference device is packaged in a standard SOT-23
small outline package, making it ideal for all surface mount
applications.
SOT-23
Fig. 1 Pin connections (top view)
FEATURES
■
Standard SOT-23 Surface Mount Package
■
Low Knee Current - Typically 80 µA
■
Low temperature Coefficient
ABSOLUTE MAXIMUM RATINGS
Reference current
2.5mA
Operating temperature range
Storage temperature range
-40°C to + 85°C
-55°C to +125°C
Fig.3 SR12D external connections.
Fig.2 SR12D circuit diagram
NOTE: In order to achieve optimum operation, an electrolytic
stabilising capacitor (CS > 1µF) should be connected between
VREF and 0V as shown in Fig. 3.
ELECTRICAL CHARACTERISTICS
These characteristics are guaranteed over the following conditions (unless otherwise stated):
Tamb = +25°C, IREF = 150µA, CS = 1µF
Value
Characteristic
Units
Symbol
Min.
Output voltage
VREF
Slope resistance (see note 1)
RREF
Turn-on (knee) current
Recommended operating current range
Temperature coefficient (see note 2)
1.193
ION
IREF
TCVREF
Typ.
1.230 1.267
2.5
1.5
EN
V
Ω
µA
IREF = 150µA to 2.5mA
80
90
2.5
mA
40
125
ppm/°C
0°C to +70°C
120
ppm/°C
-40°C to + 85°C
0.09
40
RMS noise voltage
Conditions
Max.
10
µV
Turn on time
tON
7
ms
Turn off time
tOFF
24
ms
Turn on time
tON
0.4
ms
Turn off time
tOFF
1.8
ms
1Hz to 25kHz
IREF = 5mA
SR12D
NOTES
1. Slope Resistance (RREF)
The slope resistance is defined as
RREF =
Change in VREF over specified current range
The change in reference current
2. Reference Voltage Temperature Coefficient (TCVREF)
This is the normalised reference voltage change over
temperature , divided by the change in temperature. It is
expressed in ppm/°C as follows:
TCVREF =
∆VREF x 106
VREF x ∆T
ppm/°C
∆T = temperature change in °C
∆VREF = change in reference voltage over temperature
change ∆T.
Fig.5 SR12D typical response time (not to scale)
Fig.4 Typical reference characteristic
Fig.6 Typical temperature characteristic of SR12D at IREF = 150µA
2
SR12D
Fig.7 Derating curve
3
SR12D
HEADQUARTERS OPERATIONS
GEC PLESSEY SEMICONDUCTORS
Cheney Manor, Swindon,
Wiltshire SN2 2QW, United Kingdom.
Tel: (0793) 518000
Fax: (0793) 518411
GEC PLESSEY SEMICONDUCTORS
P.O. Box 660017
1500 Green Hills Road,
Scotts Valley, California 95067-0017,
United States of America.
Tel: (408) 438 2900
Fax: (408) 438 5576
CUSTOMER SERVICE CENTRES
• FRANCE & BENELUX Les Ulis Cedex Tel: (1) 64 46 23 45 Fax : (1) 64 46 06 07
• GERMANY Munich Tel: (089) 3609 06-0 Fax : (089) 3609 06-55
• ITALY Milan Tel: (02) 66040867 Fax: (02) 66040993
• JAPAN Tokyo Tel: (03) 5276-5501 Fax: (03) 5276-5510
• NORTH AMERICA Integrated Circuits and Microwave Products Scotts Valley, USA
Tel (408) 438 2900 Fax: (408) 438 7023.
Hybrid Products, Farmingdale, USA Tel (516) 293 8686 Fax: (516) 293 0061.
• SOUTH EAST ASIA Singapore Tel: (65) 3827708 Fax: (65) 3828872
• SWEDEN Stockholm, Tel: 46 8 702 97 70 Fax: 46 8 640 47 36
• UK, EIRE, DENMARK, FINLAND & NORWAY
Swindon Tel: (0793) 518510 Fax : (0793) 518582
These are supported by Agents and Distributors in major countries world-wide.
© GEC Plessey Semiconductors 1994 Publication No. DS2442 Issue No. 2.2 January 1994
This publication is issued to provide information only which (unless agreed by the Company in writing) may not be used, applied or reproduced for any purpose nor form part of any order or contract nor to be regarded
as a representation relating to the products or services concerned. No warranty or guarantee express or implied is made regarding the capability, performance or suitability of any product or service. The Company
reserves the right to alter without prior knowledge the specification, design or price of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute
any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user's responsibility to fully determine the performance and suitability of any equipment using such information
and to ensure that any publication or data used is up to date and has not been superseded. These products are not suitable for use in any medical products whose failure to perform may result in significant injury
or death to the user. All products and materials are sold and services provided subject to the Company's conditions of sale, which are available on request.
4