BEREX BD2326_1

BD2326
Triple Band 2‐Way SMT Power Divider 1900~2500MHz PCS, WCDMA & TD‐SCDMA, WiBro Device Features





Typical Isola on = 20.0 dB Typical Inser on Loss = 0.6 dB MSL 1 moisture ra ng Small Size and Low Profile Lead‐free/RoHS‐compliant SOT‐26 Plas c Package BD23XX(XX=Wafer number)
Product Descrip on
Typical Performance1
BeRex’s Divider BD2326 is designed for PCS, WCDMA & TD‐SCDMA and WiBro band with low Inser on Loss and Isola on. This chip is fully passivated for enhanced performance and reliability and packaged in RoHS‐
compliant with SOT‐26 surface mount pack‐
age. Parameter
Min
Typical
Max
Unit
1900 15 0.65 20 2500 0.9 MHz dB dB IRL(S11) ‐15 ‐10 dBm ORL(S22/S33) Amplitude Balance Phase Balance ‐22 0.06 0.8 ‐18 0.2 1.0 dBm dB deg Frequency Range Inser on Loss Isola on *All specifica ons apply to the following test condi ons, 1. Device performance _ measured on BeRex E/B at 25°C, 50ohm system. 2. Inser on Loss: Above 3.0dB. Applica ons
 Base sta on Infrastructure  Commercial/Industrial/Military wireless system Absolute Maximum Ra ngs
Parameter Input Power Storage Temperature Opera ng Temperature Ra ng
1W CW dBm ‐55 to +155°C ‐40 to +85°C Opera on of this device above any of these parameters may result in permanent damage. Evalua on Board Drawing
Func on Block Diagram
Pins 2,4 and 6 must be DC and RF grounded. BeRex
●website: www.berex.com ●email: [email protected] 1 Specifica ons and informa on are subject to change and products may be discon nued without no ce. BeRex is a trademark of BeRex. All other trademarks are the property of their respec ve owners. © 2010 BeRex Rev. C BD2326
Triple Band 2‐Way SMT Power Divider 1900~2500MHz PCS, WCDMA & TD‐SCDMA, WiBro Typical Test Data
BeRex
Parameters Unit WCDMA & TD‐SCDMA WiBro Frequency Range MHz 1900 2075 2250 2200 2350 2500 Inser on Loss dB 0.58 0.59 0.64 0.62 0.69 0.77 Isola on dB 23.33 27.55 23.28 24.47 19.58 15.03 IRL(S11) dB 17.93 17.05 14.94 15.89 13.83 12.10 ORL(S22,S33) dB 21.92 23.04 22.90 22.81 22.00 20.09 Phase Diff. deg 0.69 0.76 0.60 0.84 0.56 0.62 Amplitude Balance dB 0.03 0.04 0.06 0.05 0.06 0.09 Inser on Loss vs. Frequency
Isola on vs. Frequency
IRL vs. Frequency
ORL vs. Frequency
●website: www.berex.com ●email: [email protected] 2 Specifica ons and informa on are subject to change and products may be discon nued without no ce. BeRex is a trademark of BeRex. All other trademarks are the property of their respec ve owners. © 2010 BeRex Rev. C BD2326
Triple Band 2‐Way SMT Power Divider 1900~2500MHz PCS, WCDMA & TD‐SCDMA, WiBro Package Outline Drawing
Suggested PCB Land Pa ern and PAD Layout PCB Land Pa ern PCB Moun ng
Note : All dimension _ millimeters
PCB lay out _ on BeRex website
BeRex
●website: www.berex.com ●email: [email protected] 3 Specifica ons and informa on are subject to change and products may be discon nued without no ce. BeRex is a trademark of BeRex. All other trademarks are the property of their respec ve owners. © 2010 BeRex Rev. C BD2326
Triple Band 2‐Way SMT Power Divider 1900~2500MHz PCS, WCDMA & TD‐SCDMA, WiBro Lead pla ng finish
100% Tin Ma e finish
(All BeRex products undergoes a 1 hour, 150 degree C, Anneal bake to eliminate thin whisker growth concerns.) MSL / ESD Ra ng
MSL Ra ng: Level 3 at +265°C convec on reflow Standard: JEDEC Standard J‐STD‐020 NATO CAGE code:
2 BeRex
N 9 6 F ●website: www.berex.com ●email: [email protected] 4 Specifica ons and informa on are subject to change and products may be discon nued without no ce. BeRex is a trademark of BeRex. All other trademarks are the property of their respec ve owners. © 2010 BeRex Rev. C