CPI VTC-6265M3

200 Watt, 5.85 - 7.10 GHz, CW traveling
wave tube, periodic-permanent-magnet
focused, coaxial input, waveguide output,
conduction cooled.
Custom configurations are also available.
These variations in the performance and
configuration include: mechanical configuration, electrical and RF connections,
and dual-stage depressed collector.
Features
•200 Watt
•Coaxial Input
•Waveguide Output
•Weight: 7.5 lbs. max
•Conduction Cooled
model
Frequency
(GHz)
5.85 - 7.10
VTC-6265M3
Power output
(min)
200 W
TYPICAL OPERATING PARAMeters
MAXIMUM
MINIMUM
Filament Voltage:6.6
6.0
Filament Current:5
---
Helix Voltage:9.2
7.6
Helix Current:15
---
Collector Voltage 1:.52 Ew
.48 Ew
Collector Current 1:
140
---
Cathode Current:
240
---
Collector Voltage 2:
.34 Ew
30 Ew
Collector Current 2:
240
---
Cathode Warm-up Time:---
3
Drive Power:
10
---
Baseplate Temp:
120
---
Prime Power:---
---
Load VSWR:
1.5:1
---
TYPICALUNITS
--- Vdc
---A
--- kVdc
--- mAdc
--- kVdc
--- mAdc
--- mAdc
--- kVdc
--- mAdc
--- Minutes
--- mW
--- °C
--- Watts
--- VSWR
The values listed above represent specified limits for the product and are subject to change. The data should be used for basic
information only. Formal, controlled specifications may be obtained from CPI for use in equipment design.
For information on this and other CPI products, visit our website at: www.cpii.com,
or contact: CPI MPP Division, 607 Hansen Way, Palo Alto, CA 94303
telephone: 1(800) 414-8823. fax : (650) 856-0705 | email : [email protected]
CPI0509
CPI | VTC-6265M3,
4CW50,000J 200 W, C-band helix twt
VTC-6265M3, 200 W, C-Band Helix TWT