EMERSON-NETWORKPOWER TLP150N

Embedded Power for
Business-Critical Continuity
Rev.7.8.09_140
TLP150 Medical Series
of 4
TLP150 Medical
Series
Single output
Total Power: 150 W
Input Voltage: 85 - 264 VAC
# of Outputs: Single
RoHS
Special Features
•
•
•
•
•
•
•
•
•
•
150 W on main channel
with only 200 LFM
Low profile fits 1U applications
Active PFC and
EN61000-3-2 compliant
Integrated control and
monitoring features
Overcurrent, overvoltage and
overtemperature protection
Compliance to EN55022-B
conducted noise standard
12 V fan output
5 V standby output (optional)
RoHS compliant
2 year warranty
Safety
• VDE EN60601-1/IEC60601-1
• UL2601-1/CSA22.2
• No. 601-1
Electrical Specifications
Input
Input voltage range:
Universal Input
Input frequency range:
85 - 264 Vac
47-63 Hz
Input surge current:
264 Vac (cold start)
40 A max.
Safety ground leakage current:
264 Vac, 50 Hz
150 µA
Input current:
120 Vac @ 150 W
230 Vac @ 150 W
1.8 A rms
0.8 A rms
Input fuse:
UL/IEC127
T 3.15 A, 250 Vac
Output
Adjustment Range:
± 10%
Total regulation (line and load): Main output
Auxiliary outputs
Fan output
Turn-on delay:
@120 Vac Input
± 3%
± 5%
± 10%
Transient response:
5%
max. dev., 1 ms max.
recovery to 1%
Main output
25% to 75%
step at 0.5 A/µs
Temperature coefficient:
2.0 s max.
± 0.02%/°C
Overvoltage protection:
Main outputs
25%, ± 5%
Short circuit protection:
Current limited
Continuous
Minimum output current:
Singles
0A
Fan voltage output:
See Note 9
12 V @ 0.5 A
Embedded Power for
Business-Critical Continuity
Rev.7.8.09_140
TLP150 Medical Series
of 4
EMC Characteristics (5)
Conducted emissions:
EN55022, FCC part 15
Level B
Harmonic current correction:
EN61000-3-2
Compliant
ESD air:
EN61000-4-2
Level 3
ESD contact:
EN61000-4-2
Level 3
Radiated immunity:
EN61000-4-3
Level 3
Fast transients:
EN61000-4-4
Level 4
Surge:
EN61000-4-5
Level 4
Conducted immunity:
EN61000-4-6
Level 3
Hold-up time:
850 Vac @ 60 Hz
20 ms @ 150 W
Efficiency:
115 Vac @ 150 W
230 Vac @ 150 W
81% typ.
84% typ.
Isolation voltage:
Input/output
Input/chassis
4000 Vac
1500 Vac
Weight:
260g (9.2 oz)
MTBF (@ 25 ºC):
Telcordia SR-332
MIL-HDBK-217F
General Specifications
900,000 hours min.
350,000 hours min.
Environmental Specifications
Thermal performance:
Operating ambient,
(See derating curve)
0° C to +70 °C
Non-operating
-40 °C to +85 °C
150 W
Relative humidity:
0 °C to 50 °C ambient,
200 LFM forced air
0 °C to 50 °C ambient,
convection cooled
50 °C to 70 °C ambient,
convection cooled
Non-condensing
Altitude:
Operating
10,000 feet max.
100 W
Derate linearly to 50% load
5 - 95% RH
Non-operating
30,000 feet max.
Vibration (See Note 7):
5 - 500 Hz
2.4 G rms peak
Shock:
per MIL-STD-810E
516.4 Part IV
Embedded Power for
Business-Critical Continuity
Rev.7.8.09_140
TLP150 Medical Series
of 4
Ordering Information
Output Voltage
Output Current
Ripple
Total Regulation
Model Numbers
12.5A
120 mV
± 3.0%
TLP150N-99S12J
6.3 A
240 mV
± 3.0%
TLP150N-99S24J
Min
Max (free air)(1,4)
Max (forced air)(2,4)
12 V
0A
8.4 A
24 V
0A
4.2A
Notes
1 Free air convection. Maximum continuous output power not to exceed 100 W. Refer to
Figure 1 for the derating curve.
2 200 LFM forced air cooling from the ac input side. Maximum continuous output power not
to exceed 150 W.
3 Figure is peak-to-peak for room temperature rating. Output noise measurements are made
across a 20 MHz bandwidth using a 6 inch twisted pair, terminated with a 10 µF tantalum
capacitor and a 0.1 µF ceramic capacitor.
4 CAUTION: Allow a minimum of 1 second after disconnecting line power when making
thermal measurements. For optimum reliability no part of the heatsink should exceed 115
°C and no semi-conductor case temperature should exceed 120 °C.
5 No external filtering required during conducted emissions testing but some applications
may require additional filtering to achieve system compliance. Compliance with radiated
EMI specifications may require mounting in a suitable enclosure.
6 This product is only for inclusion by professional installers within other equipment and
must not be operated as a stand alone product.
7 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G.
8 Replace the ‘J’ at the end of the model number with ‘FJ’ when the optional standby output
and/or remote ON/OFF control is required
e.g. TLP150N-99S12FJ.
9 12 V (fan) present when main output is present. An optional 5 Vsb (standby) output is
available whenever ac input is present, regardless of remote ON/OFF signal status.
10 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6
(non Pb-free) compliant versions may be available on special request, please contact your
local sales representative for details.­ 11 NOTICE: Some models do not support all options. Please contact your local Emerson
representative or use the on-line model number search tool at
http://www.PowerConversion.com to find a suitable alternative..
DERATING CURVE Output Power (Watts)
150 W
200 LFM (1.0 m/s)
FORCED AIR COOLING
100 W
75 W
NATURAL CONVECTION COOLING
50 W
0W
0C
10 C
20 C
30 C
40 C
50 C
60 C
70 C
Figure 1: Derating Curve
Outline Dimensions
5.000 (127.00)
4.550 (115.57)
J1 1
Neutral
FAN
1
Live
J2
1
J4
1
R88
Ground/Earth
0.225 (5.72)
ø0.156 (4 Places)
Dimensions in Inches (mm)
Figure 2: Mechanical Drawing
0.225 (5.72)
2.550 (64.77)
3.000 (76.20)
J3
Trimmer Adjust
Output Voltage
1
J301
Total Height
1.250 (31.75)
Embedded Power for
Business-Critical Continuity
Connector and Mating Connector Types
Connector
J1
J3
Type
Molex 09-65-2038 (5273 series)
void pin 2 or equivalent
Molex 09-65-2068 (5273 series)
or equivalent
Leoco 2421P04H000 (2421 series)
or equivalent
J301
(Optional)
Fan
Molex 22-23-2021(6373 series)
or equivalent
Mating Connector Type
Molex 09-52-4034 (5239 series) or equivalent with Molex 08-52-0072 (2478 series) or equivalent crimp terminals
Molex 09-52-4064 (5239 series) or equivalent with
Molex 08-52-0072 (2478 series) or equivalent crimp terminals
Leoco 2420S04000 (2420 series) or equivalent
with Leoco 2453TPH00V1 (2453T series) or equivalent crimp
terminals
or
JST EHR-4 (EH series) or equivalent with
JST SEH-001T-P0.6 (EH series) or equivalent crimp terminals
Molex 22-01-3027 (2695 series) or equivalent with
Molex 08-50-0113 (2759 series) or equivalent crimp terminals
Americas
Rev.7.8.09_140
TLP150 Medical Series
of 4
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone:+1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone:+44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
J3 Pin Connections
J1 Pin Connections
Pin 1
Pin 3
Neutral
Live
J2 Tab Connections
Tan
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone:+852 2176 3333
Facsimile: +852 2176 3888
Ground/Earth
Pin 1
RTN
Main Return
Pin 2
RTN
Main Return
Pin 3
RTN
Main Return
Pin 4
Vo
+Main Output
Pin 5
Vo
+Main Output
Pin 6
Vo
+Main Output
J4 Pin Connections
For global contact, visit:
www.PowerConversion.com
techsupport.embeddedpower@
emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
-S
-Vo Remote Sense
Pin 2
DC OK
DC Power Good Signal
Pin 3
PW OK
Power Good
Pin 4
LS
Load Share Signal
AC Power
Pin 5
+S
+Vo Remote Sense
Connectivity
Pin 6
SGND
Signal Common
Pin 1
DC Power
Embedded Computing
J301 Pin Connections (Optional)
Embedded Power
Pin 1
5 Vsb
Standby Voltage
Monitoring
Pin 2
SGND
Signal Common
Pin 3
Reserved
Do Not Connect
Outside Plant
Pin 4
PS OFF
Remote ON/OFF Signal
Fan Pin Connections
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Pin 1
+12 V
Fan Voltage
Pin 2
+SGND
Return
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co. ©2009 Emerson Electric Co.