INTERPOINT HR300

DC/DC Converters
28 Volt Input
hr300
Series 30 Watt
NOT RECOMMENDED FOR NEW DESIGNS
Features
• –40° to +85°C operation
models
VDC Output
• 18 to 36 VDC input (19 to 36 VDC input
HR301-2805)
single
• 50 V for 50 ms transient protection
5
12
15
• Fully isolated
• Fixed frequency switching
dual
±12
±15
• Remote sense on HR301-2805 model
• Inhibit function
• Indefinite short circuit protection
• Up to 86% efficiency
Size (max.): 2.720 x 1.350 x 0.505 inches (69.09 x 34.29 x 12.83 mm)
See case J5 for dimensions.
Weight:
60 grams max.
Screening: Standard only. See screening table for more information.
description
HR300 Series™ DC/DC converters combine the small size and high
reliability of hybrid-based components, the high ­efficiency of switching
regulators, and the isolation, regulation, and low noise characteristics
of linear regulators.
Small Size and Reliability
HR300 DC/DC converters use thick-film hybrid manufacturing techniques for smaller size, lighter weight and higher reliability than
converters produced with other circuit ­techniques. With a footprint
of less than 3.7 square inches and a 0.5 inch height, the HR300
converters reach power densities up to 22 watts per cubic inch.
The HR300 parts use the same manufacturing procedures and quality
controls that Interpoint applies to converters built for aerospace and
military applications. The converters are hermetically sealed in metal
packages that are guaranteed a maximum leak rate of less than 10-3
atm-cc/sec.
High Performance
HR300 converters use a constant frequency pulse-width modulated
switching regulator design operating in the ­forward mode with a clock
switching frequency of 240 to 300 kHz. Isolation is achieved through
the use of a transformer in the forward power circuit and an optocoupler in the feedback control loop. The full load output power of 30 watts
is available over the entire 18 to 36 VDC input range (19 to 36 HR3012805). On dual output models, up to 90% of full power is available from
either output up to a combined total of 30 watts.
The HR300’s high efficiency is maintained over the entire input voltage
range and from approximately 25% of full load to full load (see typical
efficiency curves).
Crane Aerospace & Electronics
Electronics Group (Interpoint Brand)
PO Box 97005 • Redmond WA 98073-9705
425.882.3100 • [email protected]
www.interpoint.com
Short circuit protection is provided through foldback ­current limiting.
When the output current reaches approximately 125% of the full rated
load, the output voltage begins to reduce to protect the converter.
The converter can sustain a true short circuit condition indefinitely.
The HR300’s flanged case facilitates removal of heat and provides
for mechanically secure mounting. If full power operation or indefinite
short circuit protection is a system requirement, the HR300 converter
should be mounted with an efficient heat sink in contact with the
mounting flange.
Internal filters in all HR300 converters provide low noise
on both the input and outputs. On HR301 models, two-section
L-C filters limit output ripple voltage and reflected input ripple current.
On HR302 models, single-section L-C filters perform the same function.
For maximum output regulation, the HR301-2805 is ­provided with
external output voltage remote sense pins. Connecting the remote
sense pins to the load provides a four-terminal voltage mode which
eliminates the adverse effects of line resistance voltage drops.
Remote sense pins may be left unconnected, but see cautions in
this data sheet. For ­normal operation, remote sense pins should be
connected to the respective output pins.
Inhibit Function
An inhibit is provided to allow a logic input to shut down the converter.
An open circuit on the inhibit pin (pin 2 or 8) allows normal operation.
A connection between the inhibit pin and the input common (pin 10)
disables the internal oscillator, shutting down the output. The inhibit pin
has an open circuit voltage of 11 to 16 V on single output models, 8
to 12 V on HR302-2812 and 10 to 14 V on HR302-2815. In the inhibit
mode, approximately 1 mA must be sunk from the inhibit pin. An active
low open collector is required to activate the inhibit function.
Page 1 of 6
HR300 Rev D - 20100212
DC/DC Converters
absolute maximum ratings
hr300
series 30 Watt
typical characteristics
Input Voltage
•18 to 36 VDC (19 to 36 VDC HR301-2805)
Output Power
•30 watts
Lead Soldering Temperature (10 sec per lead)
•300°C
Storage Temperature Range (Case)
•–55°C to +125°C
Output Voltage Temperature Coefficient
•100 ppm/°C typical
Input to Output Capacitance
•80 pF typical single output models
•70 pF typical HR302-2812
•60 pF typical HR302-2815
Current Limit
•125% of full load, typical
Isolation
•100 megohm minimum at 500 V
Conversion Frequency
•240 to 300 kHz
Inhibit Pin Voltage (unit enabled)
•11 to 16 V single output models
•8 to 12 V HR302-2812
• 10 to 14 V HR302-2815
recommended operating conditions
Input Voltage Range
•18 to 36 VDC continuous
19 to 36 VDC HR301-2805
•50 V for 50 msec transient
Case Operating Temperature (Tc)
•–40°C to +85°C full power
Derating Output Power/Current
•Linearly from 100% at 85°C to 0% at 105°C
inhibit
Inhibit TTL Open Collector
•Logic low (output disabled)
Inhibit pin current 1 mA typical
•Referenced to input common
•Logic high (output enabled)
Open collector
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
single output models
PARAMETER
CONDITIONS
hr301-2805
MIN
hr301-2812
TYP
MAX
MIN
TYP
output voltage
4.95
5.0
5.05
11.88
12
output current
—
—
6.0
—
—
2.5
MAX
14.85
15
15.15
—
—
—
30.0
—
—
30
60
—
30
70
—
30
75
mV p-p
min to max vin
input ripple current
W
—
7
25
—
10
40
—
10
40
mV
no load to full
—
5
25
—
10
40
—
10
40
mV
no load to full
19
28
36
18
28
36 18
28
36
transient 50 ms
—
—
50
—
—
50
—
—
50
15
20
—
20
35
—
20
35
1370
—
1400
—
—
15
—
—
22
—
—
22
VDC
no load
—
full load
—
inhibited
—
bw ≤ 2 MHz
—
5
15
—
10
25
—
10
25
mA p-p
79
82
—
80
84
—
82
86
—
%
—
15
—
—
30
—
—
40
—
ms
—
500
—
—
1200
—
—
1500
—
mV
efficiency
start-up
30.0
A
bw ≤ 2 MHz
input current
—
VDC
tc = -40°C to +85°C
input voltage
tc = -40°C to +85°C
30.0 —
2.0
UNITS
output ripple
load regulation2
—
12.12
TYP
output power
line regulation1
—
hr301-2815
MAX MIN
delay2
overshoot
—
Notes
1.For HR301-2805, with the remote sense pins connected to the load and
no resistance between the output pins and load.
—
—
1400
mA
2.A low output impedance power source is required on the input to realize
this start-up time. If less than full surge current is available, start-up time
will be longer
CAUTION
Permanent damage to the HR301-2805 will result if pin 6 is shorted to ground. Damage may also result if pin 4 or pin 5 is disconnected from the
load during operation with the remote sense leads connected to the load. If remote sense pins are not connected to the load, the output voltage of
theHR301-2805 will rise to approximately 6.2 VDC measured across pins 4 and 5.
www.interpoint.com
Page 2 of 6
HR300 Rev D - 20100212
DC/DC Converters
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
triple output models
PARAMETER
output voltage
output current1
output power1
hr302-2812
CONDITIONS
+ vout
- vout
MIN
TYP
hr302-2815
MAX MIN
TYP
MAX
11.88
12
12.12
14.85
15
15.15
11.88
12
12.12
14.85
15
15.15
—
tc = -40°C to +85°C
—
—
—
2.5
—
30.0 —
—
—
UNITS
VDC
2.0
A
30.0
W
bw ≤ 2 MHz
—
50
90
—
50
90
mV p-p
line regulation
vin = 18 to 36
—
10
30
—
10
40
mV
load regulation
no load to full
—
20
60
—
20
60
mV
+ vout
—
2.5
3.5
—
2.2
3.2
—
2.5
3.5
—
2.2
3.2
continuous
18
28
36 18
28
36
transient 50 ms
—
—
50
—
—
50
output ripple
cross regulation2
- vout
input voltage
tc = -40°C to +85°C
input current
input ripple current
no load
—
full load
—
inhibited
—
bw ≤ 2 MHz
—
80
—
—
1500
efficiency
start-up
delay3
overshoot
Notes
1.Up to 90% of full power is available from either output
providing the total power does not exceed 30 watts.
2.The effect on the output voltage of either output (held
at 3 watts) when the other output is varied from 3 to 27
watts.
35
45
%
VDC
50
—
1350
—
—
24
—
—
24
15
60
—
15
60
84
—
81
85
—
%
60
—
—
60
—
ms
—
—
1500
—
mV
—
60
—
hr300
series 30 Watt
mA
1400
mA p-p
3.A low output impedance power source is required on the
input to realize this start-up time. If less than full surge
current is available, start-up time will be longer
pin out
PinHR301-2805Single OutputDual Output
1 Positive Input
Positive Input Positive Input
2 Inhibit
Inhibit No connection
3 Sense Return
No connection Positive Output
4 Output Common Output Common
Output Common
5 Positive Output Positive Output Negative Output
6 Positive Sense No connection No connection
7 Case Ground
Case Ground Case Ground
8 No connection No connection Inhibit
9 No connection No connection Input Common
10 Input Common Input Common Input Common
www.interpoint.com
Page 3 of 6
HR300 Rev D - 20100212
Squared corner and dot on
top of cover indicate pin one.
1
2
3
4
5
BOTTOM VIEW
HR300
See case J5 for dimensions.
10
9
8
7
Figure 1: Pin Out
6
DC/DC Converters
hr300
series 30 Watt
Typical Performance Curves: 25°C Tc
86 18 V
86
84
84
82
82
80
78
76
36 V
28 V
80
78
36 V
76
74
72
72
70
70
70
68
68
10
15
20
25
30
36 V
78
74
5
68
5
10
15
20
25
28 V
76
72
74
18 V
80
5
30
10
15
20
25
30
Output Power (Watts)
Output Power (Watts)
Output Power (Watts)
HR301-2805 Efficiency
Figure 2
HR301-2812 Efficiency
Figure 3
HR302-2812 Efficiency
Figure 4
18
18
88
18 V
86
84
Input Voltage (Volts)
28 V
82
80
78
76
74
36 V
72
17
Inupt Voltage (Volts)
Efficiency (%)
28 V
82
Efficiency (%)
19 V
Efficiency (%)
88
86
84
Efficiency (%)
88
88
HR301-2812
16
HR301-2815
15
17
HR302-2815
16
HR302-2812
15
70
68
5
10
15
20
25
30
Output Power (Watts)
HR302-2815 Efficiency
14
5
10
15
20
25
14
30
Output Power (Watts)
Figure 6
Figure 5
model numbering key
Base Model
HR30
2 - 28
Number of Outputs
(1 = single, 2 = dual)
Input Voltage
Output Voltage
www.interpoint.com
Page 4 of 6
HR300 Rev D - 20100212
5
10
15
20
25
Output Power (Watts)
30
HR302-2812 and HR302-2815
Low Line Dropout
Figure 7
HR301-2812 and HR301-2815
Low Line Dropout
12
DC/DC Converters
hr300
series 30 Watt
BOTTOM VIEW CASE J5
1
2
3
4
5
10
9
8
7
6
1.770 (44.96)
0.040 dia.
(1.02)
1.370 (34.80)
1.173
(29.79
0.970 (24.64)
1.350 max. (34.29)
0.570 (14.48)
Squared corner and dot on top
of case indicate pin one.
0.170 (4.32)
Solder Seal
0.162 dia.
(4.11)
0.673
(17.09)
Solder Tip-off
0.173
(4.39)
2.720 max
(69.09)
Flange thickness: 0.073 (1.85) max.
Case dimensions in inches (mm)
Tolerance ±0.005 (0.13) for three decimal places
±0.01 (0.3) for two decimal places
unless otherwise specified
CAUTION
Heat from reflow or wave soldering may damage the device.
Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin.
Case J5, Rev E, 20100211
Please refer to the numerical dimensions for accuracy. All information is believed to be accurate,
but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make
changes in products or specifications without notice.
Copyright © 1999-2010 Interpoint Corp. All rights reserved.
Figure 8: Case J5
www.interpoint.com
Page 5 of 6
HR300 Rev D - 20100212
2.150 (54.61)
0.000
0.210
(5.33)
0.25 (6.4)
0.000
0.505 max
(12.83)
0.000
DC/DC Converters
hr300
series 30 Watt
HR INDUSTRIAL (STANDARD, NON-QML) PRODUCTS
ENVIRONMENTAL SCREENING
hr industrial
standard
non-Qml1
test perFormed
Pre-cap Inspection
Method 2017, 2032
yes
Final Electrical Test MIL-PRF-38534, Group A
Subgroups 1 and 4: +25°C case
yes
Hermeticity Test
Gross Leak, Dip (1 x 10-3)
yes
Final visual inspection
Method 2009
yes
TestmethodsarereferencedtomIL-STD-883asdeterminedbymIL-PRF-38534.
Notes:
1.Standard,non-QmLproducts,donotmeetalloftherequirementsofmIL-PRF-38534.
HR300 Series DC/DC Converters, HR300 Rev D - 20100212. This revision supersedes all previous releases. All technical information is believed
to be accurate, but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make changes in products or specifications
without notice. HR300 Series is a trademark of Interpoint. Copyright © 1999 - 2010 Interpoint Corporation. All rights reserved. www.interpoint.com
Page 6 of 6