MAGNETROL B25-1B10-KOE

C24, C25, Boiler
and Water Column
Liquid Level Switches
DESCRIPTION
C24, C25, Boiler and Water Column Liquid Level
Switches are single or multi-switch units that offer versatility and reliable operation in a variety of applications.
Available with up to three switch mechanisms for level
alarm, control, and shutdown functions, the boiler and
water column controls are designed for use in steam
boiler applications while the Models C24 & C25 are for
general industrial use.
FEATURES
• Easy inspection of float chamber through
removable head
• Cast iron or fabricated steel float chambers
• 316 and 316L stainless steel floats
• Brass chamber liner standard in B24, B25, W24, and
W25 models
• Right or left hand water column mounting
• Try cock tappings and sight glass tappings available
• Process temperature to +1000° F (+538° C)
• Multiple switch capability
• Working steam pressure to 600 pounds
APPLICATIONS
• Choice of switch mechanisms:
Pneumatic
Hermetically sealed
Dry contact
• Flash tank high level alarm
• Choice of switch mechanism enclosures:
• Water tube boiler low water cutoff
• Condensate receiver control
NEMA 1 carbon steel for pneumatic
• Boiler steam chest high level alarm
TYPE 4X/7/9 Class I, Div. 1, Groups C & D,
polymer coated aluminum
• Boiler feedwater pump control
• Day tanks
TYPE 4X/7/9 Class I, Div. 1, Group B,
polymer coated aluminum
• Optional high temperature insulation available.
See bulletin 41-106.
• Boiler low water cutoff
• Holding tanks
TECHNOLOGY
A permanent magnet is attached to a pivoted
switch actuator and adjustment screw . As the
float rises following the liquid level, it raises the
attraction sleeve into the field of the magnet,
which then snaps against the non-magnetic
enclosing tube , actuating the switch . The
enclosing tube provides a static pressure boundary
between the switch mechanism and the process.
On a falling level, an inconel spring retracts the
magnet, deactivating the switch.
2
5
Pivot
6
4
Return
Spring
1
3
Process Liquid
Process Liquid
Rising Level
MOUNTING
WATER
COLUMN
LEVEL
SWITCHES
The right- and left-hand mounting arrangement refers to
the position of the try cock tappings in relation to the
gauge glass connections.
Model W24—Right-hand mounting
Model W25—Right-hand mounting
Model W29—Left-hand mounting
To determine whether the control mounting is right- or
left-hand, position the control with the gauge glass connections facing you. If the try cock tappings are to the
right, it is a right-hand control, if they are to the left, it is
a left-hand control. Refer to illustrations below.
Left hand control
2
Model W60—Left-hand mounting
Right hand control
Falling Level
SPECIFICATIONS
SWITCH
MECHANISMS
AND
ENCLOSURES
SERIES B, C & D DRY CONTACT SWITCHES
SERIES F, HS, H1, 8 & 9 HERMETICALLY SEALED SWITCHES
• Dry contact for applications where
mercury must be avoided
• Ideal for use in salt and other
corrosive atmospheres
• Designs for AC and DC
current applications
• Positively pressurized capsules for
entire mechanism and contacts
• Process temperatures
to +450° F (+232° C)
• Process temperatures
to +1000° F (+538° C)
SERIES J & K PNEUMATIC SWITCHES
SWITCH ENCLOSURES
• Suited for applications where
electrical power is not available
• TYPE 4X/7/9 aluminum enclosures
• Designed to meet Class I, Div. 1,
Groups C & D and Class I, Div. 1
Group B
• Bleed and non-bleed designs
• Process temperatures
to +400° F (+204° C)
• Optional housing heaters and drains
available for some enclosures
• Pneumatic switch mechanisms
available with a NEMA 1 enclosure
BASIC ELECTRICAL RATINGS
Voltage
Switch Series and Non-Inductive Ampere Rating
B
C
D
F
HS
H1
R
120 VAC
240 VAC
24 VDC
120 VDC
240 VDC
15.00
15.00
6.00
0.50
0.25
1.00
1.00
1.00
0.40
—
15.00
15.00
10.00
1.00
0.50
10.00
—
10.00
10.00
3.00
2.50
—
4.00
0.30
—
5.00
5.00
5.00
0.50
0.25
1.00
1.00
1.00
0.40
—
8
1.00
—
3.00
—
—
9
—
—
0.50
—
—
3
AGENCY
APPROVALS
AGENCY
APPROVED MODEL
APPROVAL CLASSES
FM
All with an electric switch mechanism and a housing
listed as TYPE 4X/7/9
Class I, Div 1, Groups C & D
Class II, Div 1, Groups E, F & G
All with an electric switch mechanism and a housing
listed as TYPE 4X/7/9 Class I, Div 1, Group B
Class I, Div 1, Groups B, C & D
Class II, Div 1, Groups E, F & G
All with a Series HS, H1, F, 8 or 9 electric switch
mechanism and a housing listed as CSA TYPE 4X
Class I, Div 2, Groups B, C & D
All with an electric switch mechanism and a housing
listed as TYPE 4X/7/9
Class I, Div 1, Groups C & D
Class II, Div 1, Groups E, F & G
All with an electric switch mechanism and a housing
listed as TYPE 4X/7/9 Class I, Div 1, Group B
Class I, Div 1, Groups B, C & D
Class II, Div 1, Groups E, F & G
All with an electric switch mechanism and an
ATEX housing
ATEX II 2 G EEx d IIC T6
94/9/EC
IEC Ex Ex d IIC T6
IP 66
Low Voltage Directives 2006/95/EC
Per Harmonized Standard:
EN 61010-1/1993 & Amendment No. 1
Installation Category II
Pollution Degree 2
CSA
ATEX / IEC Ex CE
Dual stage units with “HS” or “H1” switches are not ATEX approved.
IEC Installation Instructions:
The cable entry and closing devices shall be Ex d certified suitable for the conditions of use
and correctly installed.
For ambient temperatures above +55° C or for process temperatures above +150° C, suitable
heat resistant cables shall be used.
Heat extensions (between process connection and housing) shall never be insulated.
Special conditions for safe use:
When the equipment is installed in process temperatures higher than +85° C the temperature
classification must be reduced according to the following table as per IEC60079-0.
Maximum Process
Temperature
Temperature
Classification
< 85° C
T6
< 100° C
T5
< 135° C
T4
< 200° C
T3
< 300° C
T2
< 450° C
T1
These units are in conformity with IECEx KEM 05.0020X
Classification Ex d IIC T6
Tambient -40° C to +70° C
4
DIMENSIONAL
INCHES
SPECIFICATIONS
(mm)
N
P
P
N
N
P
Q
Q
M
plugged
M
M
M
plugged
R
HL
LL
Q
M
Drum
connections
K
Gauge
glass L
tappings
K
K
LL
HL
A
R
A
HL
Low water
cutoff point
K
I
T
Try cock
tappings
I
A
G
C
M
plugged
R
LL
K
C
Models B24, C24
B
S
J
Models B25, C25
Allow 10.00 (254) overhead clearance
for cover removal.
L
K
E
D
Conduit Connections M
B
ACTUATION LEVELS *
Min. S.G.
HL
LL
S
C
Model
Models W24, W25, W29, W60
B24/C24
Electrical Switches:
TYPE 4X/7/9: 1" NPT
Group B:
1" NPT
Pneumatic Switches:
1
NEMA 1:
⁄4" NPT
B25/C25
W24
W25
All housings rotatable 360°
W29
W60
B24/C24
B25/C25
W24
W25
W29
W60
A
5.56
(141)
7.00
(177)
16.00
(405)
13.50
(343)
15.00
(381)
15.00
(381)
1.56
(40)
4.50
(114)
12.25
(311)
10.25
(260)
11.88
(302)
11.06
(281)
LL
0.94
(24)
4.13
(105)
11.88
(302)
9.88
(251)
11.50
(292)
11.19
(284)
1.69
(42)
4.88
(124)
12.63
(321)
10.63
(270)
12.25
(311)
11.69
(297)
* Single switch mechanism only. Consult factory
for multiple switches.
Levels are ±0.25" (6 mm)
DIMENSIONS
Model
0.69
(18)
3.69
(94)
11.38
(289)
9.44
(240)
11.00
(279)
10.50
(267)
1.0
HL
B
n/a
2.00
(51)
3.00
(76)
2.00
(51)
4.50
(114)
4.19
(106)
C
2.81
(71)
2.63
(66)
2.63
(66)
2.63
(66)
2.83
(71)
3.61
(91)
D
E
G
I
J
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
3.06
(77)
3.06
(77)
2.88
(73)
3.66
(92)
3.50
(88)
2.00
(51)
4.50
(114)
4.19
(106)
15.00
(381)
13.50
(343)
15.00
(381)
15.00
(381)
3.50
(88)
3.00
(76)
3.50
(88)
3.50
(88)
4.00
(101)
3.00
(76)
4.00
(101)
4.00
(101)
K
1"
NPT
1"
NPT
11⁄4"
NPT
1"
NPT
11⁄4"
NPT
11⁄4"
NPT
L
n/a
n/a
⁄4"
NPT
1
⁄2"
NPT
3
⁄4"
NPT
3
⁄4"
NPT
3
N
P
Q
R
5.93
(150)
5.93
(150)
5.93
(150)
5.93
(150)
5.93
(150)
5.93
(150)
3.78
(96)
3.78
(96)
3.78
(96)
3.78
(96)
3.78
(96)
3.78
(96)
6.25
(158)
8.46
(214)
8.46
(214)
8.46
(214)
8.46
(214)
8.46
(214)
16.25
(412)
22.12
(561)
33.50
(850)
28.62
(726)
33.50
(850)
34.37
(872)
S
T
n/a
n/a
11⁄4"
NPT
3
⁄4"
NPT
11⁄4"
NPT
3
⁄4"
NPT
3
⁄4"
NPT
n/a
3
⁄4"
NPT
1
⁄2"
NPT
3
⁄4"
NPT
3
⁄4"
NPT
5
MODEL
NUMBER
Models available for quick shipment, usually within one week after factory
receipt of a complete purchase order, through the Expedite Ship Plan (ESP)
MODEL NUMBER CODE, MATERIALS OF CONSTRUCTION AND TANK CONNECTION
Model
Code
B24-1B10 C24-1B10 B25-1B10 C25-1B10 Minimum
S.G.
Chamber
Material
Attraction
Sleeve
0.85
Cast Iron 0.84
C25-2B10 W24-1B10 0.84
Cast Iron W25-1B10 0.84
Cast Iron W29-1B10
0.84
W60-1B10
0.75
Fabricated
Steel
Float
Material
Trim
Material
Max. WSP
Rating
Max. Pressure
@ 100° F (38° C)
316L SS
316 SS
250 psi @ 406° F
(17 bar @ 207° C)
400 psi
(28 bar)
400 Series
SS
Try Cock
Mounting
N/A
316 SS
400 Series
SS
Right
Hand
400 Series
SS
316L SS
316 SS
300 psi @ 422° F
(21 bar @ 217° C)
500 psi
(34 bar)
600 psi @ 489° F
(41 bar @ 254° C)
900 psi
(62 bar)
Left
Hand
ELECTRIC SWITCH MECHANISM AND ENCLOSURE (Additional models on next page)
Switch Description
Max. Process
Temp
° F (° C)
Series B
Snap Switch
250
(121)
Series C
Snap Switch
450
(232)
Series F
Hermetically Sealed
Snap Switch
750
(399)
B24 & C24 only
Contacts
Set
Points
TYPE 4X/7/9 Aluminum Enclosure Class I, Div. 1,
Groups C & D
Class I, Div. 1,
Group B
SPDT
1
BKP
BKT
DPDT
1
BNP
BNT
SPDT
1
CKP
CKT
DPDT
1
CNP
CNT
SPDT
1
FKP
FKT
DPDT
1
FNP
FNT
PNEUMATIC SWITCH MECHANISM AND ENCLOSURE
Switch Description
Series J Bleed Type
Series K Non-Bleed Type
Maximum
Supply Pressure
psig
bar
100
60
100
40
7
4
7
3
Maximum
Process Temp.
°F
°C
400
400
400
400
204
204
204
204
Bleed Orifice
Diameter
Inches
mm
.063
.094
—
—
1.6
2.3
—
—
All except
B24, C24
NEMA 1
Code
B24, C24
NEMA 1
JDE
JEE
KOE
KOG
—
JEG
—
KOG
Cast iron models limited to maximum service temperature of
+406° F (+207° C) or switch mechanism temperature rating if lower.
Models B24, B25, W24, and W25 include brass inner liners.
Models C24 & C25 are intended for non-boiler service as they do
not contain a chamber liner.
Process temperature based on +100° F (+38° C) ambient
Consult factory for manual reset switches.
6
ELECTRIC SWITCH MECHANISM AND ENCLOSURE
Switch Description
Series B
Snap Switch
Series C
Snap Switch
Series D DC Current
Snap Switch
Series F
Hermetically Sealed
Snap Switch
Series HS
Hermetically Sealed
5-amp Snap Switch
with Wiring Leads
All models except
Model C25-2B10 only
B24, C24 and C25-2B10
Process Temperature
Set
TYPE 4X/7/9 Aluminum Enclosure
Contacts
Range
Points
ATEX
ATEX
Class I, Div 1 Class I, Div 1
Class I, Div 1 Class I, Div 1
°F (°C)
Ex II 2 G EEx
Ex II 2 G EEx
Groups C&D
Group B
Groups C&D
Group B
d IIC T6
d IIC T6
1
BKA
BKJ
BCC
BKB
BKK
BC9
SPDT
2
BLA
BLJ
BDC
BLB
BLK
BD9
-40 to +250
3
BMA
BMJ
BEC
BMB
BMK
BE9
(-40 to +121)
1
BNA
BNJ
BFC
BNB
BNK
BF9
DPDT
2
BOA
BOJ
BGC
BOB
BOK
BG9
1
CKA
CKJ
CCC
CKB
CKK
CC9
SPDT
2
CLA
CLJ
CDC
CLB
CLK
CD9
-40 to +450
3
CMA
CMJ
CEC
CMB
CMK
CE9
(-40 to +232)
1
CNA
CNJ
CFC
CNB
CNK
CF9
DPDT
2
COA
COJ
CGC
COB
COK
CG9
1
DKB
DKK
DC9
SPDT
2
DLB
DLK
DD9
-40 to +250
3
N/A
DMB
DMK
DE9
(-40 to +121)
1
DNB
DNK
DF9
DPDT
2
DOB
DOK
DG9
1
FKA
FKJ
FCC
FKB
FKK
FC9
SPDT
2
FLA
FLJ
FDC
FLB
FLK
FD9
-50 to +750
(-46 to +399)
1
FNA
FNJ
FFC
FNB
FNK
FF9
DPDT
2
FOA
FOJ
FGC
FOB
FOK
FG9
1
HMJ
HMK
SPDT
2
HMN
HMP
-50 to +550
N/A
N/A
(-46 to +288)
1
HMS
HMT
DPDT
2
HMY
HMZ
Series HS
Hermetically Sealed
5-amp Snap Switch
with Terminal Block
-50 to +550
(-46 to +288)
Series H1
Hermetically Sealed
1-amp Snap Switch
with Wiring Leads
-50 to +750
(-46 to +399)
Series R
High Temperature
Snap Switch
-40 to +750
(-40 to +399)
Series 8
Hermetically Sealed
Snap Switch
-50 to +750
(-46 to +399)
Series 9
High Temperature
Hermetically Sealed
Snap Switch
-50 to +750
(-46 to +399)
Switch Description
Series R
High Temperature
Snap Switch
Series 9
High Temperature
Hermetically Sealed
Snap Switch
SPDT
1
HM3
HM4
HA9
HM7
HM8
HB9
HKJ
HKK
HKN
HKP
RKB
RLB
RNB
ROB
8KB
8LB
8MB
8NB
8OB
9KB
9LB
9MB
9NB
9OB
RKK
RLK
RNK
ROK
8KK
8LK
8MK
8NK
8OK
9KK
9LK
9MK
9NK
9OK
N/A
DPDT
1
SPDT
1
N/A
DPDT
SPDT
DPDT
SPDT
DPDT
SPDT
DPDT
N/A
2
1
2
1
2
1
2
3
1
2
1
2
3
1
2
N/A
8KA
8LA
8MA
8NA
8OA
9KA
9LA
9MA
9NA
9OA
8KJ
8LJ
8MJ
8NJ
8OJ
9KJ
9LJ
9MJ
9NJ
9OJ
8CC
8DC
8EC
8FC
8GC
9CC
9DC
9EC
9FC
9GC
RC9
RD9
RF9
RG9
8C9
8D9
8E9
8F9
8G9
9C9
9D9
9E9
9F9
9G9
Process Cast Iron
Cast Iron
CS/Aluminum
CS/Aluminum
Set
Temp. Range Contacts
Class I, Div 1 Class I, Div 1
Class I, Div 1 Class I, Div 1
Points
NEMA 4X
NEMA 4X
°F (°C)
Groups C&D
Group B
Groups C&D
Group B
1
R1M
RKM
RKW
SPDT
2
R3M
RLM
RLW
-40 to +1000
N/A
(-40 to +538)
1
RDM
RNM
RNW
DPDT
2
REM
ROM
ROW
1
9AD
9KD
9KV
9AM
9KM
9KW
SPDT
2
9BD
9LD
9LV
9BM
9LM
9LW
-50 to +1000
3
9CD
9MD
9MV
9CM
9MM
9MW
(-46 to +538)
1
9DD
9ND
9NV
9DM
9NM
9NW
DPDT
2
9ED
9OD
9OV
9EM
9OM
9OW
7
QUALITY
The quality assurance system in place at Magnetrol
guarantees the highest level of quality throughout
The Magnetrol quality assurance system is registered to ISO 9001 affirming its commitment to
the company. Magnetrol is committed to providing
full customer satisfaction both in quality products
known international quality standards providing the strongest assurance of product/service
and quality service.
quality available.
Several Level Switches are available for quick
shipment, usually within one week after factory
receipt of a complete purchase order, through
the Expedite Ship Plan (ESP).
ESP service may not apply to orders of ten units
or more. Contact your local representative for
lead times on larger volume orders, as well as
other products and options.
ESP
Expedite
Ship
Plan
To take advantage of ESP, match the color
coded model number codes in the selection
charts (standard dimensions apply).
WARRANTY
All Magnetrol mechanical level and flow controls are warranted free of defects in materials
or workmanship for five full years from the
date of original factory shipment.
If returned within the warranty period; and,
upon factory inspection of the control, the
cause of the claim is determined to be covered
under the warranty; then, Magnetrol will repair
or replace the control at no cost to the purchaser
(or owner) other than transportation.
Magnetrol shall not be liable for misapplication,
labor claims, direct or consequential damage or
expense arising from the installation or use of
equipment. There are no other warranties
expressed or implied except special written
warranties covering some Magnetrol products.
5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com
145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306
Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93
Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317
Copyright © 2011 Magnetrol International, Incorporated. All rights reserved. Printed in the USA.
Performance specifications are effective with date of issue and are subject to change without notice.
Magnetrol & Magnetrol logotype are registered trademarks of Magnetrol International.
BULLETIN: 46-118.17
EFFECTIVE: August 2010
SUPERSEDES: July 2008