MAGNETROL S21-1A1A-12

External Chamber
Sealed or Flanged Top
DESCRIPTION
The Magnetrol ® external chamber is a self-contained
cage designed for use with our top mounting level
transmitters or switches. Quality construction and a
wide selection of configurations make this cage an ideal
means of utilizing the power of our many technologies
without mounting directly into the process vessel. The
chamber is suitable for use with Eclipse® Guided Wave
Radar and Kotron ® RF Capacitance transmitters, all
electronic point sensors and top mounted displacer
switches.
FEATURES
• Sealed or flanged-top chamber options
• 2" and 3" nominal chamber diameters to accommodate
all sensing elements
• Carbon steel or 316 stainless steel materials of
construction
• Rugged MAGNETROL commercial construction available as well as ASME B31.3, ASME B31.1, NACE or
combined NACE and ASME B31.3 construction options
• Rated for pressures up to 5000 psi (345 bar)
• For applications to +750° F (+400° C)
• Lengths for measuring ranges to twenty feet (6.1 m)
• Broad selection of process connections sizes and types
• Head flange bolting included with flange-top models
• Optimal design for use with ECLIPSE Guided Wave
Radar transmitter:
• Smallest possible chamber diameters
• Pressure rating to match High Temperature, High
Pressure (HTHP) and High Pressure (HP) probes
• Temperature rating to match HTHP probe
• Space above and below measuring range to
accommodate measurement transition zones
• Suitable for use with RF capacitance transmitters, all
electronic point sensors and top mounted displacer
switches
APPLICATIONS
• Replace existing caged torque-tube controls
• New construction as well as retrofits
• Boiler feed-water heaters
• High pressure process vessels
• Turbulent vessel conditions
• Isolation of instrument desirable
• Elevated temperature process conditions
• Hydrocarbon and chemical process tanks
COMMERCIAL
DESIGN
• ASTM materials per model number
• Welding per ASME Section IX procedures
• Hydrostatic test at 1.5 × rated pressure
• Slip-on head and process flanges (A) (unless weld
neck connections are specified in model number)
• Branch connections are pipe to pipe (B) for ≤ 600# construction and Bonney type fittings (C) for ≥ 900# construction
ASME
B31.1
DESIGN
• Flanged or sealed cages
CODE
• ASME grade materials procured with Certificate of
Conformance
• Full penetration chamber branch welds (G)
• Slip-on head and process flanges (A) for ≤ 300#
construction (unless weld neck connections are specified in model number), weld neck head (D) and process
flanges (F) for ≥ 600# construction
• Branch connections are Bonney type fittings (C)
• Full penetration circumferential welds (H) for
≥ 600# construction
• 100% visual inspection of circumferential welds for
full penetration for ≥ 600# construction
• Certified ten minute hydrostatic test at 1.5 × rated pressure
• Flanged or sealed cages
• Welding done by ASME qualified welders per
ASME Section IX procedures
ASME
B31.3
DESIGN
• Stress limits per code
CODE
• ASME grade materials procured with Certificate of
Conformance
• Full penetration chamber branch welds (G)
• Slip-on head and process flanges (A) for ≤ 900#
construction and 2" 1500# cages (unless weld neck
connections are specified in model number)
• Weld neck head flange (D), slip-on process flanges for
3" 1500# cages (unless weld neck connections
are specified in model number)
(A)
• Full penetration circumferential welds (H) for 5000 psi
construction and 3" 1500# cages
• 100% visual inspection of circumferential welds for
full penetration for ≥ 600# construction
• Certified ten minute hydrostatic test at 1.5 × rated pressure
• Five percent radiographic examination of full penetration
circumferential welds
• Weld neck head (D) and process flanges (F) for 5000 psi
construction
• Flanged or Sealed cages
• Branch connections are Bonney type fittings (C)
• Stress limits per code
• Welding done by ASME qualified welders per
ASME Section IX procedures
NACE
DESIGN
CODE
• ASME grade and NACE listed materials procured
with Certificate of Conformance
• Hydrostatic test at 1.5 × rated pressure
• Carbon steel cage assembly is post weld heat treated
• Slip-on head and process flanges (A) (unless weld neck
connections are specified in model number)
• Welds and adjacent heat affected zones are hardness tested
• Branch connections are pipe to pipe (B) for ≤ 600#
construction and Bonney type fittings (C) for ≥ 900#
construction
• 316 stainless steel pressure boundary parts are annealed, if
required, to achieve required hardness
• Welding done by ASME qualified welders per
ASME Section IX procedures
2
• Flanged or sealed cages
DESIGN
CONSTRUCTION
COMPARISON
Comm
B31.3
B31.1
NACE
ASME grade and NACE listed materials
•
•
•
Certificate of Conformance on materials
•
•
•
Slip-on head and process
flanges Weld neck head and slip-on process
Weld neck head and process flanges
Pipe to pipe branch connections
•
flanges ≤600#
≥900#
≤1500#
≤300#
3" 1500#
5000 psi ≥600#
•
≤600#
•
•
≥900#
Welding by ASME qualified welders per ASME Section IX procedures
•
•
•
Full penetration chamber branch welds
•
Bonney type fittings
•
ASME Section IX welding procedures
•
≥1500# ≥600#
≥1500# ≥600#
Full penetration circumferential welds
100% visual inspection of circumferential welds for full penetration
Hydrostatic test at 1.5 × rated pressure
•
Certified ten minute hydrostatic test at 1.5 × rated pressure
•
•
•
•
Five percent radiographic examination of full penetration circumferential welds
Post weld heat treatment
CS
Annealing, if required for hardness
SS
Hardness testing of welds and adjacent heat affected zones
•
•
Flanged or sealed chambers
Stress limits per design code
•
•
•
•
•
Unless weld neck process flanges are specified in model number
Except 3" 1500# cage
Except 2" 1500# cage
A
Slip-on
process flange
D
Weld neck
head flange
F
Weld neck
process flange
H
Full penetration
circumferential weld
B
Pipe to pipe branch
connection
C
Bonney fitting
Fillet weld
G
Full penetration
chamber branch weld
Sealed Chamber
Flanged Chamber
3
DIMENSIONAL
HEAD
FLANGE
Design Standard
(third digit)
INFORMATION
TYPE
Chamber Rating
(fifth digit)
Process Connection Type (seventh digit)
NPT
(A, G)
Socket Weld
(B, H)
Slip-on RF
(D, K)
Weldneck RF
(E, L)
Weldneck RTJ
(F, M)
150# (A)
300# (B)
Commercial
600# (C)
(1, 5)
900# (D)
1500# (E)
Slip-on raised face
5000 psi (F)
150# (A)
300# (B)
ASME B31.3
600# (C)
(4, 7)
Weldneck raised face
900# (D)
1500# (E)
5000 psi (F)
150# (A)
Slip-on raised face
300# (B)
ASME B31.1
*
n/a
Weldneck raised face
600# (C)
(3)
900# (D)
1500# (E)
Weldneck raised face
n/a
5000 psi (F)
* 1500# ASME B31.3 will have a slip-on head flange on 2" cage and weld neck head flange on 3" cage
PROBE
LENGTH
If utilizing a sealed top chamber, go to page 5 for ‘A’ dimension.
To properly size your sensing element when mounting in a flange top chamber, it is necessary to determine the dimension from the face of the head flange to the centerline of the upper process connection. To determine this dimension:
1. Use the third, fifth & seventh digits of your chamber model number and the above chart to verify the type of head
flange on your chamber.
2. On page 5, locate the ‘A’ dimension of your chamber according to the chamber pressure rating, head flange type,
design standard, chamber size & process connection size.
3. Go to the formulas on page 6 for probe or cable lengths. Using your ‘A’ dimension and measuring range (customer
designated), determine your required probe length.
A
Measuring
Range
A
A
Measuring
Range
Measuring
Range
1" NPT drain
Sealed Chamber
Slip-on head flange
See bulletin 41-640 for additional dimensional information.
4
1" NPT drain
Weld neck head flange
DIMENSIONAL
SEALED
CHAMBER
INFORMATION
(“A”
DIMENSION)
Commercial – all pressures, chamber sizes, & connection sizes = 7.00" (178 mm)
ASME 31.3 – all pressure, chamber sizes, & process connection sizes = 7.68" (195 mm)
Slip-on process flanges not available on 5000 psi construction
ASME 31.1 – all pressure, chamber sizes, & process connection sizes = 7.68" (195 mm)
Slip-on process flanges not available on 600#, 900#, 1500#, and 5000 psi construction
FLANGED
Chamber
Pressure
Rating
CHAMBER
(“A”
DIMENSION)
2" Chamber
Head Flange
Type
Design
Standard
3" Chamber
Process Connection Size
⁄4"
3
1"
11⁄2"
Process Connection Size
2"
1"
⁄4"
3
11⁄2"
2"
Commercial
slip-on
ASME 31.3
6.00" (152 mm)
ASME 31.1
150#
Commercial
weldneck
ASME 31.3
6.00" (152 mm)
ASME 31.1
7.50"
(191 mm)
Commercial
slip-on
ASME 31.3
6.00" (152 mm)
6.00" (152 mm)
ASME 31.1
300#
Commercial
weldneck
ASME 31.3
6.00" (152 mm)
ASME 31.1
Commercial
slip-on
ASME 31.3
ASME 31.1
600#
6.00" (152 mm)
n/a
Commercial
weldneck
ASME 31.3
ASME 31.1 Commercial
slip-on
ASME 31.3
ASME 31.1
900#
6.00" (152 mm)
ASME 31.3
ASME 31.1 Commercial
slip-on
ASME 31.3
ASME 31.1
1500#
n/a
7.50"
(191 mm)
n/a
n/a
6.00" (152 mm)
6.50"
(165 mm)
slip-on
Commercial
8.50" (216 mm)
ASME 31.3
ASME 31.1
5000 psi
6.50" (165 mm) ASME 31.3 ASME 31.1 6.50"
7.50"
(165 mm)
8.50" (216 mm)
Except with 2" weldneck process flanges = 7.00" (178 mm)
Except with 1–11⁄2" and 2" weldneck process flanges = 7.50" (191 mm)
Except with 1–11⁄2" and 2" weldneck process flanges = 9.50" (241 mm)
No slip-on process flanges
Stainless steel materials of construction only. Carbon steel is not available.
(191 mm)
8.50" (216 mm)
n/a
Commercial
weldneck
7.00"
(178 mm)
6.00" (152 mm)
n/a
n/a
6.50" (165 mm)
6.00" (152 mm) 6.50" (165 mm)
6.50" (165 mm)
ASME 31.3
ASME 31.1 7.00"
(178 mm)
6.00" (152 mm)
6.00" (152 mm)
Commercial
weldneck
6.00" (152 mm) 6.00" (152 mm)
Commercial
weldneck
7.50"
(191 mm)
n/a
9.50"
(241 mm)
8.50" (216 mm)
8.50"
(216 mm)
9.50"
(241 mm)
5
PHYSICAL
SPECIFICATIONS
Measuring span length
ECLIPSE probe length sealed cage
flanged cage
KOTRON probe length sealed cage
flanged cage
Displacer cable length (min.)
Materials of Construction
From 12 to 240 inches (30-610 cm)
Measuring range
Sensor Connections
Process Connection Sizes
Process Connection Ratings
Process Connection Types
Connection Configurations
Process Pressures
Process Temperatures
Measuring range
Measuring range
+ A + 5 inches (13 cm) (rounded down to nearest inch)
+ A + 6 inches (15 cm) (rounded down to nearest inch)
+ A + 3 inches (7 cm) (rounded down to nearest inch)
Measuring range + A + 4 inches (10 cm) (rounded down to nearest inch)
Measuring range + A + 6 inches (15 cm) (rounded up to nearest foot)
Carbon steel or 316 stainless steel
(head flange bolting ASTM A193 GrB7 regardless of chamber material)
3
⁄4" or 2" NPT, 2" or 3" flange from 150# to 2500# ANSI 3
⁄4", 1", 11⁄2" or 2"
150#, 300#,600#, 900#, 1500# or 2500# ANSI threaded, socketweld, slip-on RF flanges,
weldneck RF flanges, weldneck RTJ flanges
Side-side, side-bottom
Up to 5000 psi (345 bar)
Up to +750° F (+399° C)
See bulletin 57-101 for ECLIPSE transmitter and probe part numbers.
Measuring range is last three digits of chamber model number.
See bulletin 50-125 for KOTRON probe part numbers.
See bulletin 45-115 for top mounted displacer switch part numbers and allowable high level
dimension with respect to face of mounting flange.
Must be used in 3" flanged cage.
Maximum pressure rating of cage with 2500# flanges is 5000 psi @ 100° F (345 bar @ 38° C).
MODEL
NUMBER
MOUNTING
S
F
Sealed external chamber (NPT sensor connection)
Flanged top external chamber
NOMINAL CHAMBER DIAMETER
2
3
2 inch If sealed chamber, 3⁄4" NPT sensor conn. If flanged chamber, flanged sensor conn. same size as chamber
3 inch
If sealed chamber, 2" NPT sensor conn. If flanged chamber, flanged sensor conn. same size as chamber
Displacer switches require 3" cage.
DESIGN STANDARD
1
3
4
5
7
Commercial Construction
ASME B31.1 Certified ASME B31.3 Certified Commercial Construction and NACE certified ASME B31.3 Certified and NACE certified Level switch/transmitter must also be specified to required code, if applicable.
ASME B31.1, 5000 psi chambers not available in carbon steel.
6
MODEL
NUMBER
CONTINUED
MATERIALS OF CONSTRUCTION 1
4
Carbon Steel, measuring range in inches 316/316L Stainless Steel, measuring range in inches
Process connection materials will match chamber materials
CHAMBER RATING
A
B
C
D
E
F
150#
300#
600#
900#
1500#
5000
11
11
ANSI class
ANSI class
ANSI class
ANSI class
ANSI class
psi (process flanges will be 2500# ANSI)
Process flange, if applicable, will match chamber rating, except as indicated
PROCESS CONNECTION SIZE
3
1
⁄4"
2
1"
3
11⁄2"
4
2"
PROCESS CONNECTION TYPE AND CONFIGURATION 12
Side/Side Configurations
A
NPT
B
SW
D
Slip-on RF Flange 14
E
Weldneck RF Flange
Chamber rating codes A, B & C only
F
Weldneck RJ Flange
Chamber rating codes C, D, E & F only
Side/Bottom Configurations
G
NPT
H
SW
K
Slip-on RF Flange 14
L
Weldneck RF Flange
Chamber rating codes A, B & C only
M
Weldneck RJ Flange
Chamber rating codes C, D, E & F only
12
13
14
Head Flange Type
Slip-on or weld neck 13
Weld neck
Slip-on or weld neck 13
Weld neck
Process connection materials will match chamber materials
See page 4 to determine type of head flange
Cannot use slip-on flanges on 2" or 3", 5000 psi for B31.3, nor on 2" or 3", ≥600# for B31.1
MEASURING RANGE
12 to 240 inches, fourth digit numeric
Example: 12 inches = 012
7
QUALITY
The quality assurance system in place at
MAGNETROL guarantees the highest level
The MAGNETROL quality assurance system is
registered to ISO 9001 affirming its commitment
of quality throughout the company.
MAGNETROL is committed to providing full
customer satisfaction both in quality products
to known international quality standards
providing the strongest assurance of product/
service quality available.
and quality service.
WARRANTY
All MAGNETROL mechanical level and flow
controls are warranted free of defects in materials
or workmanship for five full years from the
date of original factory shipment.
If returned within the warranty period; and,
upon factory inspection of the control, the
cause of the claim is determined to be covered
under the warranty; then, MAGNETROL will
repair or replace the control at no cost to the
purchaser (or owner) other than transportation.
MAGNETROL shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or
use of equipment. There are no other warranties
expressed or implied, except special written
warranties covering some MAGNETROL products.
5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com
145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306
Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93
Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317
Copyright © 2011 Magnetrol International, Incorporated. All rights reserved. Printed in the USA.
Performance specifications are effective with date of issue and are subject to change without notice.
Magnetrol & Magnetrol logotype and Eclipse and Kotron are registered trademarks of Magnetrol International, Incorporated.
BULLETIN: 41-140.0
EFFECTIVE: March 2001