MEANWELL DKA30_11

DKA30
25~30W DC-DC Dual Output Converter
series
Features :
2:1 wide input range
4:1 wide input range(option)
1000VDC I/O isolation
Built-in EMI filter
Trimming output( 10%)
Remote ON-OFF control
Protections: Short circuit / Overload
Cooling by free air convection
Six-sided shield metal case
Epoxy encapsulated
100% burn-in test
Approvals: FCC / CE
2 years warranty
SPECIFICATION
ORDER NO.
DKA30A-05 DKA30B-05 DKA30C-05 DKA30A-12 DKA30B-12 DKA30C-12 DKA30A-15 DKA30B-15 DKA30C-15
DC VOLTAGE
5V
12V
CURRENT RANGE
250 ~ 2500mA
125 ~ 1250mA
RATED POWER
25W
15V
100 ~ 1000mA
30W
30W
RIPPLE & NOISE (max.) Note.2 100mVp-p
LINE REGULATION
Note.3 0.5%
OUTPUT
LOAD REGULATION
Note.4
VOLTAGE ACCURACY
0.5%
2.0%
SWITCHING FREQUENCY
100KHz min.
EXTERNAL TRIM Adj. RANGE 10%
A: 9 ~ 18VDC
VOLTAGE RANGE
EFFICIENCY (Typ.)
DC CURRENT
FILTER
SHORT CIRCUIT
A: 3.2A
No load
A: 40mA B: 20mA C: 10mA
80%
WORKING HUMIDITY
20% ~ 90% RH non-condensing
10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
I/P-O/P:1KVDC
I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 Class B, FCC part 15 Class B
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A
REMOTE CONTROL
Power on: R.C ~-Vin > 4.5~5.5VDC or open, Power off : R.C~ -Vin <0.8VDC or short
MTBF
DIMENSION
100Khrs min. MIL-HDBK-217F (25 )
50.8*50.8*21.0mm or 2"*2"*0.82" inch (L*W*H)
WEIGHT
110g
21 ( 0.82 )
8
BOTTOM
VIEW
12.7 ( 0.50 )
Pin No. Output
1
2
3
4
SIDE
VIEW
50.8 ( 2.00 )
7
+ 0.2/-0.1
45.72 ( 1.80 )
6
1.0
3
2
15.24 ( 0.60 )
50.8 ( 2.00)
Pin No. Output
5
6
7
8
R.C
No Pin
-Vin
+Vin
-Vin
+Vout
100
-Vout
5.8 ( 0.23 )
80
6
1
2.5( 0.10 )
+Vout
COM
-Vout
TRIM
External Output Trimming
3
4
Derating Curve
Pin Configuration
Unit: mm (inch)
30.48 (1.20)
81%
83%
-40 ~ +105 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
Mechanical Specification
7
20K
LOAD
VR
-40
0
25
50
71 85
100
VR
4
+Vin
TRIM
8
Ta (
UP
NOTE
81%
83%
C: 0.77A
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-40 ~ +85 (Refer to output load derating curve)
EMS IMMUNITY
22.9 ( 0.90 )
B: 1.5A
WORKING TEMP.
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
5
80%
Full load
110 ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
All output equipped with short circuit
OVERLOAD
PROTECTION
OTHERS
C: 36 ~ 72VDC
80%
Pi network
Fuse recommended
PROTECTION
(Note. 5)
B: 18 ~ 36VDC
80%
LOAD (%)
INPUT
80%
DOWN
)
TRIMPOT
1.All parameters are specified at normal input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load.
5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
File Name:DKA30-SPEC 2011-03-08