MEANWELL PLD-16-1050

PLD-16
16W Single Output LED Power Supply
series
Features :
115VAC or 230VAC models available
Built-in active PFC function
Constant current design
Protections: Short circuit / Over temperature
Cooling by free air convection
Fully isolated plastic case
Class 2 Power Unit
Class
power unit, no FG
IP30 design
Suitable for indoor LED lighting applications
100% full load burn-in test
Low cost
High reliability
3 years warranty
F
110
( for B type only)
( for B type only)
PLD-16-350 A
( for 350mA)
SELV
(except for 350mA)
( for A type only)
( for B type only)
A : With AC input 90~ 135VAC.
B : With AC input 180~ 295VAC.
SPECIFICATION
MODEL
RATED CURRENT
PLD-16-350
PLD-16-700
PLD-16-1050
PLD-16-1400
350mA
700mA
1050mA
1400mA
16 ~ 24V
12 ~ 16V
8 ~ 12V
0 ~ 700mA
0 ~ 1050mA
0 ~ 1400mA
OPERATING VOLTAGE RANGE 24 ~ 48V
0 ~ 350mA
CURRENT RANGE
OUTPUT
INPUT
CURRENT ACCURACY
16.8W
16.8W
16.8W
RIPPLE & NOISE (max.) Note.1 4.6Vp-p
16.8W
2.7Vp-p
2.2Vp-p
2Vp-p
NO LOAD OUTPUT VOLTAGE (max.) 63V
35V
25V
16V
RATED POWER
SETUP TIME
1000ms / 230VAC 2000ms / 115VAC at full load
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.9/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
A series
B series
AC CURRENT (Typ.)
INRUSH CURRENT(max.)
PROTECTION
0.2A/230VAC
OVER TEMPERATURE
82.5%
83.5%
0.15A/277VAC
<0.5mA / 240VAC
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +50
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
0.03%/
, 10 ~ 95% RH
(0 ~ 50
)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL 8750,CSA C22.2 No.250.0-08(except for PLD-16-350);ENEC EN 613471-1,EN 61347-2-13 independent(for B type only)approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015 (B type only), EN61000-3-2 Class C ; EN61000-3-3, FCC part 18 non-consumer equipment(A type only)
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level, criteria A
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSION
PACKING
NOTE
0.4A/115VAC
40A/230VAC
84%
85%
Hiccup mode, recovers automatically after fault condition is removed.
95
10 (RTH1)
VIBRATION
OTHERS
84.5%
86%
SHORT CIRCUIT
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
EMC
84.5%
86%
LEAKAGE CURRENT
WORKING TEMP.
SAFETY &
5.0%
906.5Khrs min. MIL-HDBK-217F (25
84*57*29.5mm (L*W*H)
0.19Kg; 72pcs/14.7Kg/0.92CUFT
)
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:PLD-16-SPEC 2012-03-16
PLD-16
16W Single Output LED Power Supply
Mechanical Specification
Case No.PCD16A
series
Unit:mm
A Type:(PLD-16-_A)
3
84
150 10
7.3
57
15.3
UL1430 18AWG
7.3
75 5
UL1430 18AWG
AC/L(BLACK)
3.6
2 - - 8 .9
2
15.3
10
20
AC/N(WHITE)
T case
V+(RED)
V-(BLACK)
3
1.9
29.5
T case: Max. Case Temperature.
B Type:(PLD-16-_B)
3
84
150 10
NISPT-1 18AWG
10
20
AC/N(WHITE)
7.3
T case
AC/L(BLACK)
V+(RED)
V-(BLACK)
3.6
2 - - 8 .9
2
15.3
7.3
75 5
57
15.3
UL1430 18AWG
3
1.9
29.5
T case: Max. Case Temperature.
Block Diagram
fosc : 90KHz(115VAC)
120KHz(230VAC)
I/P
EMI FILTER
&
RECTIFIERS
POWER
SWITCHING
O.L.P.
RECTIFIERS
&
FILTER
+V
-V
DETECTION
CIRCUIT
PWM & PFC
CONTROL
O.C.P.
File Name:PLD-16-SPEC 2012-03-16
PLD-16
16W Single Output LED Power Supply
Derating Curve
series
Static Characteristics
100
100
90
80
80
70
LOAD (%)
60
LOAD (%)
50
40
20
-30
60
50
40
-25
-5
0
15
30
40
AMBIENT TEMPERATURE (
50
60
(HORIZONTAL)
90
180
135 Type A (60Hz)
295 Type B (50Hz)
INPUT VOLTAGE (V)
)
Power Factor Characteristic
PF
Constant Current Mode
1 .0 0
0 .9 8
0 .9 6
0 .9 4
0 .9 2
0 .9 0
0 .8 8
0 .8 6
0 .8 4
0 .8 2
0 .8 0
0 .7 8
2 7 7 V a c(B T y p e)
2 3 0 V a c(B T y p e)
1 1 5 V a c(A T y p e)
50%
60%
70%
80%
90%
100%
(16W)
LOAD
EFFICIENCY vs LOAD (PLD-16-350)
EFFICIENCY (%)
PLD-16 series possess superior working efficiency that up to 86%
can be reached in field applications.
86
82
78
74
70
66
62
58
54
50
46
42
38
34
30
277Vac(B Type)
230Vac(B Type)
115Vac(A Type)
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
File Name:PLD-16-SPEC 2012-03-16