MEANWELL PSP-600

PSP-600
600W with PFC and Parallel Function
series
Features :
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
With DC OK Signal output
Current sharing up to 2400W(3+1)
Built-in remote ON-OFF control
Built-in remote sense function
Fixed switching frequency at PFC:88KHz PWM:100KHz
3 years warranty
SPECIFICATION
MODEL
OUTPUT
PSP-600-5
PSP-600-12
PSP-600-13.5
PSP-600-15
PSP-600-24
PSP-600-27
DC VOLTAGE
5V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
80A
50A
44.5A
40A
25A
22.2A
12.5A
CURRENT RANGE
0 ~ 80A
0 ~ 50A
0 ~ 44.5A
0 ~ 40A
0 ~ 25A
0 ~ 22.2A
0 ~ 12.5A
RATED POWER
400W
600W
600.75W
600W
600W
599.4W
600W
RIPPLE & NOISE (max.) Note.2 180mVp-p
240mVp-p
240mVp-p
240mVp-p
240mVp-p
240mVp-p
300mVp-p
VOLTAGE ADJ. RANGE
10 ~ 13.2V
1.0%
12 ~ 15V
1.0%
13.5 ~ 18V
1.0%
20 ~ 26.4V
1.0%
24 ~ 30V
1.0%
41 ~ 56V
1.0%
4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1500ms, 50ms at full load
SETUP, RISE TIME
20ms at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
INPUT
PROTECTION
Note.5 88 ~ 264VAC
124 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
0.95/230VAC
EFFICIENCY(Typ.)
79%
84%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
6.8A/115VAC
20A/115VAC
3.4A/230VAC
40A/230VAC
0.99/115VAC at full load
85%
85%
<1.3mA/240VAC
OVERLOAD
OVER VOLTAGE
5.75 ~ 6.75V
13.8 ~ 16.2V
15.5 ~ 18.2V
18 ~ 21V
Protection type : Shut down o/p voltage, re-power on to recover
(TSW1) detect on heatsink of power transistor; 95
+12V ~ +48V: 85 (TSW1) detect on heatsink of power transistor; 80
Protection type : Shut down o/p voltage, re-power on to recover
REMOTE CONTROL
POK SIGNAL
WORKING TEMP.
RC+/RC-: Short = power on ; Open = power off
PSU turn on: 3.3V ~ 5.6V
PSU turn off: 0V ~ 1V
-20 ~ +60 (Refer to "Derating Curve")
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
EMC IMMUNITY
MTBF
DIMENSION
PACKING
-40 ~ +85
27.6 ~ 32.4V
31 ~ 36.5V
87%
57.6 ~ 67.2V
(TSW51) detect on heatsink of power diode
OVER TEMPERATURE
20 ~ 90% RH non-condensing
NOTE
86%
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
OTHERS
86%
LEAKAGE CURRENT
+5V: 95
FUNCTION
PSP-600-48
(TSW51) detect on heatsink of power diode
, 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
116.4K hrs min. MIL-HDBK-217F (25 )
170*120*93mm (L*W*H)
1.9Kg; 8pcs/15.5Kg/1.06CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:PSP-600-SPEC 2011-11-30
PSP-600
600W with PFC and Parallel Function
Mechanical Specification
Case No.910A
series
Unit:mm
Terminal
JST XHP
or equivalent
JST SXH-001T
or equivalent
Pin No.
1
2
3
4
5
6
7
8~11
12~15
Air flow
direction
Terminal Pin No. Assignment
2-M3 L=4mm max.
Assignment
AC/L
AC/N
FG
P(Current Share)
POK
R.C. G
R.C.
DC OUTPUT +V
DC OUTPUT -V
100
Mating Housing
2-M3 L=4mm max.
150
185
170
120
8
1
2
3
150
11.5
4
5
6
7
2-M3 L=4mm max.
2-M3 L=4mm max.
14 max.
93
Assignment
RS+
RS-
50
Pin No.
1
2
58.3
RS Connector(CN5) : JST B-XH or equivalent
12
CN5
8
9 10 11 12 13 14 15
9.5
11.5
Block Diagram
PFC fosc : 88KHz
PWM fosc : 100KHz
FAN
ACTIVE
INRUSH
CURRENT
LIMITING
EMI
FILTER
I/P
RECTIFIERS
&
P.F.C.
SIGNAL
CONTROL
RECTIFIERS
&
FILTER
POWER
SWITCHING
POK
CURRENT
SHARING
CIRCUIT
+V
-V
RC.G.
RC
O.C.P.
FG
O.L.P.
P
DETECTION
CIRCUIT
PWM
CONTROL
O.V.P.
O.T.P.
Derating Curve
Output Derating VS Input Voltage
100
100
Others
90
80
80
70
12V
50
LOAD(%)
LOAD (%)
60
40
20
-20
0
10
20
30 40 45
50
AMBIENT TEMPERATURE ( )
60 (HORIZONTAL)
60
50
40
88
100
115
135
155
230
264
INPUT VOLTAGE (V) 60Hz
File Name:PSP-600-SPEC 2011-11-30
PSP-600
600W with PFC and Parallel Function
series
Control Terminal Instruction Manual
POK(+) RCG(-)
L
N FG
RCG RC
P POK RCG RC
L
+V +V +V +V -V -V -V -V
N FG
P POK RCG RC
L
+V +V +V +V -V -V -V -V
RS+ RS-
RS+ RS-
-
+
LOAD
-
+
LOAD
LOAD
Remote Sensing
POK Signal
P POK RCG RC
+V +V +V +V -V -V -V -V
RS+ RS-
+
N FG
Remote Control
Power ON: RCG and RC for short
Power OFF: RCG and RC for open
POK Signal is the voltage difference between
"RCG" and "POK" pin output POK Signal for TTL level signal
PSU turn on: 3.3V ~ 5.6V
PSU turn off: 0V ~ 1V
Parallel Operation with Remote Sensing
(1)Parallel operation is available by connecting the units shown as below (+S,-S and P are connected mutually in parallel) :
(2)The voltage difference among each output should be minimized that less than 2% is required.
(3)The total output current must not exceed the value determined by the following equation (Output current at parallel operation)
=(The rated current per unit) x (Number of unit) x 0.9.
(4) In parallel operation 4 units is the maximum, please consult the manufacture for other applications.
(5) When remote sensing is used in parallel operation, the sensing wire must be connected only to the master unit.
(6) When in parallel operation, the minimum output load should be greater than 3% of total output load.
(Min. load > 3% rated current per unit x number of unit)
LOAD
+V
+S
+
-
P RCG RS+ RS-
PSU
+
-
P RCG RS+ RS-
PSU
-V
-S
+
-
P RCG RS+ RS-
PSU
+
-
P RCG RS+ RS-
PSU
File Name:PSP-600-SPEC 2011-11-30