MPSIND MPU15A-105

MPU15A SERIES
15W Desk Top Switching Power Supplies For Medical Equipment.
Description:
The MPU15A series of AC/DC switching mode power supplies
provide 15 Watts of continuous output power and is well-suited
for a variety of applications. All supplies are UL 94V-1 min
compliant. All models comply with UL/c-UL(UL 606011:2ndEdition), TUV/T-mark(EN 60601-1:2ndEdition) and new
CE requirements. All units are 100% burned-in and tested.
Features:
Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Single Output
Energy Star 2.0, Efficiency level V
Over Voltage and Over Load protection.
Over temperature Detection
Class I
3 year warranty
Safety Approvals:
EN 60601-1
IEC 60601-1
RT
PS
E
Electrical Characteristics:
Sym.
Vin
Parameter
Test Conditions
CB
Agree to apply for the PSE
if order on hand
Min. Typ. Max.
Unit
Safety Approvals Input
Voltage Range
100
240
VAC
Operate Voltage Range
90
264
VAC
fin
Input Frequency
47
63
Hz
Po
Output Power Range
0
15
W
Vo
Output Voltage Range
Vin=90 to 264VAC
See rating chart
V
See rating chart
A
Io
Output Current Range
Iil
Input Current (Low Line)
Io=Full load, Vin=115VAC
0.25 0.33
A
Iih
Input Current (High Line)
Io=Full load, Vin=230VAC
0.17 0.18
A
Irl
Low Line Inrush Current
Io=Full load, 25c, Cool start,
Vin=115VAC
18
23
A
Irh
High Line Inrush Current
Io=Full load, 25c, Cool start,
Vin=230VAC
38
45
A
Eff
Efficiency
Io=Full Load, Vin=230VAC
REG-i Line Regulation
Io=Full Load
REG-o Load Regulation
Vin=230VAC
1
○
OVP
Over Voltage
OCP
1
Over Current○
Protection
Ttr
Time of Transient Response
Protection
Thold Hold-Up Time
Ts
Vp-p
Start Up Time
85
%
0.5
1
%
3
5
%
112
132
%
110
150
%
4
mS
1
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=110VAC
10
Io=Full Load, Vin=100VAC
Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
Ilk
Safety Ground Leakage Current Io=Full Load, Vin=240VAC
TC
Temperature Coefficient
All output
Pno
No-Load Power Consumption
No load, Vin=230VAC
The parameter is not subject
to production test-verified
by design/characterization
of integrated controller.
Tjsd
73
1 by
Thermal Shutdown○
Junction Temperature
Controller
16
1
S
0.5
1
%
0.3
mA
0.04
%/c
0.3
W
125
c
-0.04
0
mS
0.5
0.25
-20
1 When the power system interruption is isolated, the product would re-start after recovering by hand.
○
Environmental :
Sym.
Toper
Tstg
Ho
Hr
Parameter
T e s t Conditions
Operating Temperature
Min. Typ. Max.
Unit
50
C
0
70
Storage Temperature
-40
85
C
Operating Humidity
0
95
%
Storage Humidity
0
75
%
MTBF
Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Pd
Derate linearly from 100% load at 50 C to 50% load at 70 C
0.1M
Hrs
MPU15A SERIES
15W Desk Top Switching Power Supplies For Medical Equipment.
Safety Specifications:
Sym.
Vps
Vpg
Ris
Parameter
Min. Typ. Max.
Unit
Primary to secondary
5656
VDC
Primary to ground
2828
VDC
T e s t Conditions
Dielectric Withstanding Voltage
for Primary to secondary
Dielectric Withstanding Voltage
for Primary to Ground
Isolation Resistance
E N 5 5 0 2 2 EMI requirements for EN55022
EMI requirements for FCC PART-18
FCC
M
Test Voltage=500VDC
50
Vin=230VAC,50HZ
B
CLASS
Vin=120VAC,60HZ
B
CLASS
Output Voltage And Current Rating Chart ( Single Output ) :
①
*
*
*
*
Model Number
Output Voltage
Outpu t Current
Total
Regulation
Maximum
Output Power
MPU15A-102
5 ~ 6 VDC
2.60~2.16 A
5%
13W
MPU15A-103
6 ~ 8 VDC
2.16~1.62 A
5%
13W
5%
15W
MPU15A-104
8 ~ 11 VDC
1.87~1.36 A
MPU15A-105
11 ~ 13 VDC
1.36~1.15 A
5%
15W
MPU15A-106
13 ~ 16 VDC
1.15~0.93 A
5%
15W
MPU15A-107
16 ~ 21 VDC
0.93~0.71 A
5%
15W
MPU15A-108
21 ~ 27 VDC
0.71~0.55 A
3%
15W
MPU15A-109
27 ~ 33 VDC
0.55~0.45 A
3%
15W
33 ~ 36 VDC
0.45~0.41 A
3%
15W
MPU15A-110
Mark “
①
*
” means approved by PSE.
MPU15A-102.103 are required to use AWG#16 / 4FT output cable.
MPU15A-105~110 are required to use AWG#18 / 4FT output cable.
The regulation and efficiency will be changed by modified output cable.
Mechanical Specifications :
Note:
1. Dimensions are shown in mm.
2. Weight: 170gs approx.
3. Optional output connector:
See page Appendix.