SCHURTER UMF250

UMF 250
Non resettable fuses
www.schurter.com/pg01_2
Surface Mount Fuse, 10.1 x 3 mm, Quick-Acting F, 250 VAC, 125 VDC
IEC 60127-4 · 250 VAC · 125 VDC · Quick-Acting F
Description
Applications
-Directly solderable on printed circuit boards
-Low melting I²t-values, fast interruption
-Compact design
-Primary Protection on SMD PCB
-Secondary Protection DC and AC
-Industrial electronic
-Medical equipments
-Power Supplies
Standards
-IEC 60127-4/2
-UL 248-14
-CSA C22.2 no. 248.14
References
Packaging Details
Weblinks
Approvals
pdf, html, General Product Information, Approvals, RoHS, CHINA-RoHS,
e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check
-VDE Certificate Number: 40027880
-UL File Number: E41599
Technical Data
Rated Voltage
Rated Current
Breaking Capacity
Characteristic
Mounting
Admissible Ambient Air Temp.
Climatic Category
Material: Housing
Material: Terminals
Unit Weight
Storage Conditions
Product Marking
250 VAC, 125 VDC
0.5 - 10 A
100 A - 200 A
Quick-Acting F
PCB,SMT
-55 °C to 125 °C
55/125/21 acc. to IEC 60068-1
Ceramic
Tin-Plated Copper Alloy
0.23 g
0 °C to 40 °C, max. 70% r.h.
, Current, Voltage, Characteristic,
Breaking Capacity
Dimensions
Soldering Methods
Solderability
Resistance to Soldering Heat
Life Test
Moisture Resistance Test
Case Resistance
Mechanical Shock
Resistance to Solvents
Flammability
Reflow, Wave
245 °C / 3 sec acc. to IEC 60068-2-58,
Test Td
260 °C / 10 sec acc. to IEC 60068-2-58,
Test Td
1000h @ 0.60 x In @ 70°C
(acc. to EIA/IS-722, Test 4.4.1)
MIL-STD-202, Method 106E
(acc. to EIA/IS-722, Test 4.4.3)
>100 MΩ (between leeds and body)
acc. to EIA/IS-722, Test 4.7
MIL-STD-202, Method 213B
(Shock 50gn, half sine wave, 11 ms)
MIL-STD-202, Method 215A
min. UL 94V-1
(acc. to EIA/IS-722, Test 4.12)
1.6
0.4
3.75
10.1 mm
1.43
6.5
10.1
2
3
Soldering pads
Fuses
UMF 250
Non resettable fuses
www.schurter.com/pg01_2
Pre-Arcing Time
Rated Current In
1.0 x In min.
1.25 x In min.
2.0 x In max.
-
60 min
120 s
1 ms
10 ms
4h
-
120 s
1 ms
10 ms
0.5 A - 8 A
10 A
10.0 x In min. 10.0 x In max.
Variants
Rated Current [A]
Rated Voltage [VAC]
Rated Voltage [VDC]
0.5
250
125
1
250
4
250
8
10
Breaking
Capacity
Voltage Drop
1.0 In max.
[mV]
Voltage Drop
1.0 In typ.
[mV]
Power Dissipation 1.25 In
typ. [mW]
Melting I²t
10.0 Intyp.
[A²s]
Order Number
1)
600
343
500
0.27
l
l
3405.0163.xx
125
1)
300
257
500
0.4
l
l
3405.0166.xx
125
2)
300
100
2000
9.4
l
l
3405.0172.xx
250
125
2)
220
190
3000
1.4
l
l
3405.0175.xx
250
125
3)
220
164
3500
2.8
l
3405.0176.xx
1) IEC: 100 A @ 250 VAC, p.f. ≥ 0.95 / 100 A @ 125 VDC
1) UL: 200 A @ 250 VAC, p.f. ≥ 0.95 / 200 A @ 125 VDC
2) IEC: 100 A @ 250 VAC, p.f. ≥ 0.95 / 100 A @ 125 VDC
2) UL: 100 A @ 250 VAC, p.f. ≥ 0.95 / 100 A @ 125 VDC
3) UL: 100 A @ 250 VAC, p.f. ≥ 0.95 / 100 A @ 125 VDC
Packaging Unit .xx = .11Plastic Bag (100 pcs.)
.xx = .24Blister Tape 33 cm Reel (2000 pcs.)
Time-Current-Curves
10000
1000
500 mA
1A
4A
8A
10 A
100
Time in Seconds
10
1
0.1
0.01
0.001
0.0001
0.1
1
10
100
Current in Amperes
The
specifications, descriptions and illustrations indicated in this document are based on
Fuses