SECOS MMDL914

MMDL914
Surface Mount Switching Diode
Elektronische Bauelemente
RoHS Compliant Product
A suffix of "-C" specifies halogen & lead-free
FEATURES
. Fast Switching Speed
. For General Purpose Switching Application
. Surface Mount Package Ideally Suited for
SOD-323L
0.091 (2.3)
0.110 (2.8)
Automatic Insertion
0.045 (1.15)
0.053 (1.35)
0.010 (0.25)
0.016 (0.40)
MECHANICAL DATA
. Case: SOD-323L, Molded Plastic
. Polarity: See Diagrams Below
. Mounting Position : Any
. Shipping : 3000 / Tape & Reel
0.063 (1.60)
0.071 (1.80)
0.031 (0.80)
0.043 (1.10)
0.002 (0.05)
0.010 (0.25)
Dimensions in inch (mm)
1
2
CATHODE
ANODE
MAXIMUM RATINGS
Rating
Reverse Voltage
Forward Current
Peak Forward Surge Current
Symbol
Value
Unit
VR
100
Vdc
IF
200
mAdc
IFM(surge)
500
mAdc
Symbol
Max
Unit
PD
200
mW
1.57
mW/°C
RθJA
635
°C/W
TJ, Tstg
-50 to +150
°C
THERMAL CHARACTERISTICS
Characteristic
Total Device Dissipation FR-5 Board,*
TA = 25°C
Derate above 25°C
Thermal Resistance Junction to Ambient
Junction and Storage Temperature
**FR-4 Minimum Pad
DEVICE MARKING
MMDL914 = 5D
ELECTRICAL CHARACTERISTICS (TA = 25°C unless otherwise noted)
Characteristic
Symbol
Min
Max
Unit
V(BR)
100
—
Vdc
—
—
25
5.0
nAdc
mAdc
OFF CHARACTERISTICS
Reverse Breakdown Voltage
(IR = 100 mAdc)
Reverse Voltage Leakage Current
(VR = 20 Vdc)
(VR = 75 Vdc)
IR
Diode Capacitance
(VR = 0, f = 1.0 MHz)
CT
—
4.0
pF
Forward Voltage
(IF = 10 mAdc)
VF
—
1.0
Vdc
Reverse Recovery Time
(IF = IR = 10 mAdc) (Figure 1)
trr
—
4.0
ns
http://www.SeCoSGmbH.com
01-Jun-2007 Rev. B
Any changing of specification will not be informed individual
Page 1 of 2
MMDL914
Surface Mount Switching Diode
Elektronische Bauelemente
820 Ω
+10 V
2.0 k
tr
0.1 µF
100 µH
tp
IF
IF
t
trr
10%
t
0.1 µF
90%
DUT
50 Ω Input
Sampling
Oscilloscopes
50 Ω Output
Pulse
Generator
IR(REC) = 1.0 mA
IR
VR
Output Pulse
(IF = IR = 10 mA; Measured
at IR(REC) = 1.0 mA)
Input Signal
Notes: 1. A 2.0 kΩ variable resistor adjusted for a Forward Current (IF) of 10 mA.
Notes: 2. Input pulse is adjusted so IR(peak) is equal to 10 mA.
Notes: 3. tp » trr
Figure 1. Recovery Time Equivalent Test Circuit
10
100
TA = 85°C
TA = 125°C
1.0
IR , Reverse Current (µA)
IF, Forward Current (mA) (mA)
TA = 150°C
10
TA = – 40°C
1.0
TA = 25°C
TA = 85°C
0.1
TA = 55°C
0.01
TA = 25°C
0.001
0.1
0.2
0.4
0.6
0.8
VF, Forward Voltage (V)
1.0
10
0
1.2
Figure 2. Forward Voltage
20
30
VR, Reverse Voltage (V)
40
50
Figure 3. Leakage Current
CD, Diode Capacitance (pF)
0.68
0.64
0.60
0.56
0.52
0
2
4
6
8
VR, Reverse Voltage (V)
Figure 4. Capacitance
http://www.SeCoSGmbH.com
01-Jun-2007 Rev. B
Any changing of specification will not be informed individual
Page 2 of 2