XPPOWER CPH500USC3

Component Power AC Front End Modules
500 & 1000 Watts
THE XPERTS IN POWER
CPH Series
•
85-264 VAC Input
•
PFC to EN61000-3-2
•
Efficiency up to 95%
•
Fixed Switching Frequency
•
Parallel Operation
•
Compatible with CPM Series
•
International Approvals
Specification
Input
Input Voltage
•
Input Frequency
Input Current
(Typical)
Inrush Current
•
•
•
Inrush Current
Protection
Power Factor
•
Leakage Current
•
•
85-264 VAC (derate the CPH1000 to
850 W between 85 & 95 VAC)
47-63 Hz
5.6/4.0 A at 115/230 VAC CPH500
11.5/8.5 A at 115/230 VAC CPH1000
15/30 A typ at 115/230 AC CPH500
CPH1000 limited by external
resistance
contact technical sales for details
Standard
0.98 typical (complies with
EN61000-3-2 85-255 VAC)
<0.3 mA CPH500, <0.75 mA CPH1000
Switching Frequency •
Power Good Signal
•
Inverter Operation
Monitoring
Enable Signal
•
•
Environmental
Operating
Temperature
Storage Temperature
Humidity
Vibration
•
-20 °C to +85 °C (aluminium baseplate)
•
•
•
Shock
•
-40 °C to +85 °C
20-95% RH non-condensing
10-55 Hz 5G 3 minute period,
60 mins along each X, Y & Z axis
20 G 11 ms once each X, Y & Z axis
Output
Output Power
•
Output Voltage
•
Minimum Load
Overvoltage
Protection
Thermal Protection
•
•
•
500/1000 W for CPH500/1000
95-170 VAC
750/1500 W for CPH500/1000 with
input voltage 170-264 VAC
300-360 VDC (automatically changes
according to the input voltage)
No minimum load required
390-440 VDC CPH500,
400-450 VDC CPH1000
+100 °C ±15 °C (baseplate)
Current Share
•
Standard
•
•
90/95% typical at 100/200 VAC
Input to Output not isolated,
3000 VAC Input to Ground
500 VDC Output to Ground
General
Efficiency
Isolation
170 kHz CPH500, 130 kHz CPH1000
Open-collector output, max sink
current 5 mA, max voltage 35 V
CPH500
Open-collector output, max sink
current 5/10 mA for CPH500/CPH1000
Open-collector output, max sink
current 10 mA, max voltage 35 V
CPH1000 only
Safety
Emissions
•
ESD Susceptibility
Radiated
Susceptibility
EFT/Burst
Surge
Safety Approvals
•
•
EN55022 Level B conducted
EN55022 Level B radiated
External components required
Contact Sales for Application Note
EN61000-4-2 Level 2
EN61000-4-2 Level 3
•
•
•
EN61000-4-4 Level 3
EN61000-4-5 Level 3, 4
EN60950, UL1950, CUL1950
•
•
www.xpplc.com
[email protected]
Mechanical Details - CPH500USC3
Weight <150g
Pin Connection
Function
1
CB
Current Balance
2
IOG
Inverter Operation Monitor
3
AC
AC Input
4
5
SR
Inrush Current Protection
6
R
External Resistor For Inrush Current Protection
7
+ DC OUT
+ DC (+ V) Output
8 - V DC OUT
- DC (- V) Output
9
PR
Power Ready Signal
10
AUX
Auxillary Power Supply For External Signal
FG
Frame Ground
Mechanical Details - CPH1000USC3
Weight <200g
Pin Connection
Function
1
AC1
AC Input
2
AC2
3
R
External Resistor For Inrush Current Protection
4
+V OUT
+DC Output
5
-V OUT
-DC Output
6
AUX
Auxiliary Power Supply for External Signal
7
IOG
Inverter Operation Monitor
8
CB
Current Balance
9
ENA
Enable Signal
www.xpplc.com
[email protected]
Rev 3.0