ALLEN-BRADLEY MSR211P

Safety Relays
Modular Monitoring Safety Relays
Minotaur MSR211P
Category
Description
The MSR211P forms one of the base units for the modular
Minotaur MSR200 family of monitoring safety relays. It can be
combined with other modules of the MSR200 Series to configure a
safety control system with numbers of inputs and outputs matching
users’ specific application requirements, as well as diagnostic and
networking capabilities. Up to 10 input modules and 2 output
modules can be connected to one base unit by simply removing the
terminator, included with each base unit, and connecting the ribbon
cables of the neighboring module. The terminators must be inserted
into the final input and output modules.
The MSR211P has two inputs. Each input can be wired in one of
three ways: 1N.C., 2 N.C., or 2 PNP connections from a light
curtain. The MSR211P does not perform cross fault monitoring,
and would not detect a short across the inputs of a 2 N.C. input.
When connected to light curtains, the light curtain must perform the
cross fault detection.
24V DC; 0.8 to 1.1 x rated voltage
Power Consumption
8W
Safety Inputs
1 N.C., 2 N.C., light curtain
Input Simultaneity
Infinite
Max. Input Resistance Inputs
Reset
1300ohms
3200ohms
Reset
Monitored Man. or Auto./Man.
Outputs
2 N.O. safety; 1 N.C. auxiliary
1 SS PNP Inputs Closed
1 SS PNP Outputs Active
Output Utilization per IEC
60947-4-1 (Resistive)
AC-1: 6A/250V AC
DC-1: 6A/24V DC
➊ Output Utilization per IEC
60947-5-1 (Inductive)
B300, AC-15;
3A/250V AC, 3A/125VAC
P300, DC-13; 2.5A/24V DC
Thermal Current (non switching)
1x6A, 2x4A
Output, Solid State
20mA @ 30V DC
Fuses Output (external)
6A slow blow or 10A quick blow
Min. Switched Current/Voltage
10mA/10V DC
Contact Material
AgSnO2 with 2 micron gold plating
Ribbon Cable Contacts
Gold plated
Power On Delay
3s
Response Time MSR211
MSR211+ MSR221
25ms
30ms+2.4ms per MSR221
Recovery Time
40-145 ms, depending on
expansion modules used
Indication LEDs
Green = Input 1 closed
Red = Input 1 open
Green = Input 2 closed
Red = Input 2 open
Green = CH1 output active
Green = CH2 output active
Green = Power
Green = Run (outputs active)
Red = Stop (outputs off) +
diagnostics
Amber = Ready (inputs closed)
The MSR211P has the capability to perform external device
monitoring (EDM). The EDM capability works in conjunction with
the reset option. The user selects EDM and the reset function by
jumpers across terminals Y40, Y41 and Y42.
The MSR211P has two semiconductor outputs designed to send
status information to a PLC. Terminal Y33 indicates the inputs are
closed (the Ready LED is on). Terminal Y32 indicates the outputs
are active.
The outputs include 2 normally open safety rated outputs and 1
normally closed auxiliary output. The safety outputs have
independent and redundant internal contacts to help ensure the
safety function.
Cat. 4 per EN954-1 (ISO13849-1)
Power Supply
Impulse Withstand Voltage
2500V
Pollution Degree
2
Operating Temperature
-5°C to +55°C (+23°F to 131°F)
Humidity
90% RH
Enclosure Protection
IP40 (NEMA 1)
Terminal Protection
IP20
Short Circuit Protection
Input; SS outputs
Features
Conductor Size
0.2–4mm2 (24–12 AWG)
•
•
•
•
•
•
•
•
Torque Settings—term. screws
0.4–0.5 Nm (3.54–4.43lb•in)
Case Material
Polyamide PA 6.6
Category 4 per EN 954-1
Stop category 0
2 Input circuits: light curtain, gate, or E-Stop inputs
2 Safety outputs, 1 auxiliary output
2 Solid state outputs
10 Diagnostic LEDs
Monitored or automatic reset
Removable terminals
Specifications
Standards
EN 954-1, ISO 13849-1, IEC/EN
60204-1, IEC 60947-4-1, IEC
60947-5-1, ANSI B11.19, AS4024.1
Approvals
C-Tick, CE marked for all
applicable directives, cULus & TUV
4-74
Mounting
35mm DIN rail
Weight
280g (0.62lbs)
Electrical Life
222V AC/4A/880VA cosϕ=0.35
220V AC/1.7A/375VA cosϕ=0.6
30V DC/2A/60W
10V DC/0.01A/0.1W
100,000 operations
500,000 operations
1,000,000 operations
2,000,000 operations
Mechanical Life
2,000,000 cycles
Vibration
10-55 Hz, 0.35mm
Shock
10g, 16ms, 100 shocks
➊ See Output Ratings on page 1-29 for details. Consult factory for ratings not
shown.
Safety Relays
Modular Monitoring Safety Relays
Minotaur MSR211P
Product Selection
Inputs
Safety Outputs
Auxiliary Outputs
Solid State Outputs
Power Supply
Catalogue Number
Two Inputs
1 N.C. or 2 N.C. or
Light Curtain
2 N.O.
1 N.C.
2
24V DC
440R-H23177
Dimensions—mm (inches) Block Diagram
45 (1.77)
99 (3.89)
S12
S11
S20
S21
S32
S31
S51
S41
Y40
13
23 31
14
24 32
13
23
Y41 Y42
33
A1
K1
114.5
(4.5)
K2
Y1
S42
Y2
S50
S34
S62
Y31
Y32
Y31 Y32 Y33 Y30
14
24
Y33
A2
32
Typical Wiring Diagrams
Y31 Y40 Y41 Y42 13 23 31
Termination or
Expansion Cable
S32
A1 S12
Termination or
Expansion Cable
Termination or
Expansion Cable
Light Curtain
Out 1
Out 2
L1 L2 L3
K1
MSR211P
Light Curtain
Out 1
Out 2
S32
A1 S12
Y31 Y40 Y41 Y42 13 23 31
K1
K2
M
K1 K2
Reset
Ground
Output
Active
Safety Gate
Safety Gate
Y30 Y32 Y33 S34 Y1 Y2 14 24 32
Closed
L1 L2 L3
MSR211P
K2
A2 S42 S62
Termination or
Expansion Cable
+24V DC
+24V DC
A2 S42 S62
Light Curtain and Dual Channel Safety Gate,
Monitored Manual Reset, Monitored Output
M
K1 K2
Closed
Reset
Ground
Inputs
Closed
Y30 Y32 Y33 S34 Y1 Y2 14 24 32
Output
Active
Inputs
Closed
Light Curtain and Single Channel Safety Gate,
Monitored Manual Reset, No Monitoring Output
Light Curtain
Out 1
Out 2
S32
A1 S12
Y31 Y40 Y41 Y42 13 23 31
Termination or
Expansion Cable
Termination or
Expansion Cable
+24V DC
MSR211P
L1 L2 L3
K1
Safety Gate
K2
A2 S42 S62
Y30 Y32 Y33 S34 Y1 Y2 14 24 32
K1 K2
Closed
Ground
Output
Active
M
Inputs
Closed
Light Curtain and Dual Channel Safety Gate,
Automatic Reset, Monitored Output
Diagnostics – Red Stop LED blinks
Blink Rate
Description
2
Change in Y40/Y41/Y42 circuit during operation.
3
Fault in external feedback circuit Y1-Y2. Clear fault and
cycle power to reset the module.
Continuous
Internal fault in base or expansion module
4-75