CANDD NDY

NDY SERIES
Isolated 3W Wide Input DC/DC Converters
Min
Efficiency1
Typical
Isolation
Capacitance
SELECTION GUIDE
(V)
(V)
(mA)
(mA)
(mA)
(%)
(pF)
kHrs
NDY0505
5
5
100 -150
400- 600
615
66
40
1939
NDY0509
5
9
55-83
222-333
563
72
52
1926
NDY0512
5
12
42-62
166-250
548
71
43
1907
NDY0515
5
15
33-50
133-200
533
73
44
1924
FEATURES
NDY1205
12
5
150
600
362
71
36
1928
■ Industry Standard Footprint
NDY1209
12
9
83
333
320
78
52
1916
■ Single Isolated Output
NDY1212
12
12
62
250
316
78
44
1897
NDY1215
12
15
50
200
308
79
47
1914
NDY2403
24
3.3
227
909
178
70
30
1671
NDY2405
24
5
150
600
174
70
36
1673
NDY2409
24
9
83
333
156
78
52
1663
■ Power Density 0.90W/cm
NDY2412
24
12
62
250
154
80
44
1644
■ 2:1 Wide Input Range
NDY2415
24
15
50
200
150
82
54
1657
NDY4803
48
3.3
227
909
87
71
30
1676
NDY4805
48
5
150
600
87
73
35
1668
NDY4809
48
9
83
333
78
80
52
1663
■ No Heatsink Required
NDY4812
48
12
62
250
77
81
44
1648
■ Internal SMD Construction
NDY4815
48
15
50
200
76
81
53
1661
Nominal Rated
Input
Output
Voltage Voltage
Order Code
■ Short Circuit Protection
■ Operating Temperature Range
-40°C to +85°C
■ Low Profile 24 Pin Case
■ Efficiency to 82%
3
■ 5V, 12V, 24V & 48V Input
■ 3.3V, 5V, 9V, 12V & 15V Output
■ Footprint 4.73cm2
■ UL 94V-0 Package Materials
Output Current 4
Min Load
Input
Current
Full Load
Full Load
MTTF3
■ Fully Encapsulated
■ Lead Free Compatible
INPUT CHARACTERISTICS
Parameter
DESCRIPTION
The NDY series is a range of low profile
DC/DC converters offering a single regulated
output over a 2:1 input voltage range. All
parts deliver 3W output power up to 85°C
without heatsinking, except the 4.5V to 9V
input voltage range which should be derated
to 2W at the lower input voltage. A flyback
oscillator design with isolated feedback is
used to give regulation over the full operating
range of 25% to 100% of full load. It is
strongly recommended that external
capacitors be used on input and output to
guarantee performance over full load and
input voltage range (see recommended filter
circuit for values). The plastic case and
encapsulant materials are rated to UL 94V-0
and the connection pins are formed from a
tin plated alloy 42 leadframe.
www.cdpoweronline.com
Voltage Range
Reflected1
Ripple
Current
Conditions
MIN
TYP
MAX
All NDY05XX
All NDY12XX
All NDY24XX
All NDY48XX
NDY24032
NDY48032
All NDY05XX
All NDY12XX
All other NDY24XX
All other NDY48XX
4.5
9
18
36
5
12
24
48
180
140
400
150
290
100
9
18
36
72
360
290
500
170
360
127
Units
VDC
mA p-p
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection
Input voltage 05 types
Input voltage 12 types
Input voltage 24 types
Input voltage 48 types
Lead temperature 1.5mm from case for 10 seconds
Minimum Load
Internal Dissipation
continuous
10V
20V
40V
80V
300°C
25% of rated load
1.7W
1 Measured at full load with external input/output capacitors, refer to filter circuit 1.
2 For lower ripple refer to filter circuit 2.
3 Calculated using MIL-HDBK-217F with nominal input voltage at full load.
4 Refer to power derating graph.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
NDY SERIES
Isolated 3W Wide Input DC/DC Converters
OUTPUT CHARACTERISTICS
Parameter
Conditions
Voltage Set Point Accuracy
With external input/output capacitors, refer to filter circuits
Low line to high line, 3.3V output with external input/output capacitors,
refer to filter circuit 1
Low line to high line, with external input/output capacitors,
refer to filter circuit 1
25% load to 100% load, 3.3V output with external input/output capacitors,
refer to filter circuit 1
25% load to 100% load, with external input/output capacitors,
refer to filter circuit 1
BW = 20Hz to 300kHz. 3.3V output with external input/output capacitors,
refer to filter circuit 1
BW = 20Hz to 300kHz. With external input/output capacitors,
refer to filter circuit 1
BW = DC to 100MHz. 3.3V output with external input/output capacitors,
refer to filter circuit 1
BW = DC to 100MHz. With external input/output capacitors,
refer to filter circuit 1
Line Regulation
Load Regulation
Ripple2
Noise
MIN
TYP
MAX
Units
±1
±5
%
0.05
0.2
%
0.05
0.5
%
0.6
0.5
%
0.2
0.5
%
80
120
mV rms
5
10
mV rms
180
mV p-p
50
100
mV p-p
TYP
MAX
Units
ISOLATION CHARACTERISTICS
Parameter
Conditions
Isolation Test Voltage
Resistance
Flash tested for 1 second
Viso=500VDC
MIN
1000
1
VDC
GΩ
GENERAL CHARACTERISTICS
Parameter
Conditions
MIN
Switching Frequency
100% load VIN nominal 3.3V output
25% load VIN nominal 3.3V output
100% load VIN nominal
25% load VIN nominal
160
290
80
290
TYP
MAX
Units
220
560
220
560
kHz
MECHANICAL DIMENSIONS
1.27 (32.26)
PIN CONNECTIONS (TOP VIEW)
1
24
VIN
0V
10
15
0V
+V
11
14
+V
GND
12
13
GND
VIN
0.577
(14.66)
0.275
(7.00)
0.185 (4.70)
0.145 (3.70)
0.033 (0.84)
0.021 (0.54)
1.10 (27.94)
0.10
(2.54)
0.012 (0.30)
0.008 (0.20)
0.644
(16.35) Max
Weight: 6.2g (3.3V O/P 6.7g)
1 Measured at full load with external input/output capacitors, refer to filter circuit 1.
2 For lower ripple refer to filter circuit 2.
3 Calculated using MIL-HDBK-217F with nominal input voltage at full load.
4 Refer to power derating graph.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
www.cdpoweronline.com
NDY SERIES
Isolated 3W Wide Input DC/DC Converters
FILTER CIRCUITS
EXTERNAL CAPACITANCE
Value
Although these converters will work without
external capacitors, they are necessary in
order to guarantee the full parametric
performance over the full line and load
range. All parts have been tested and
characterised using the following values and
test circuit.
CIN
COUT
LOUT
10µF, 200V
Philips Part Number
151621809 or any
good low esr capacitor
100µF, 25V
Philips Part Number
13556101 or any good
low esr capacitor
C&D Technologies Part
No 24100
FILTER CIRCUIT 1
VIN
+VOUT
CIN
COUT
NDY
OUTPUT LOAD
The minimum rated load across the whole
input voltage range is 25% of the full load
output. It is important to take care that the
load does not fall below this as the output
ripple will greatly increase. While this
condition will not harm the device the
resultant increase in output ripple could cause
customers’ application to malfunction.
GND
OV
FILTER CIRCUIT 2 Recommended circuit for reduced ripple 3.3V O/P
LOUT
VIN
CIN
NDY
GND
Operation
Storage
Cooling
Conditions
MIN
-40
-50
TYP
MAX
Units
85
130
°C
°C
Free air convection
NDY05 POWER DERATING CURVE
Output Power (W)
5
4
3
2
1
0
4.5 5
6
7
Input Voltage (V)
8
9
C&D Technologies (NCL) Limited reserve the right to alter or improve the
specification, internal design or manufacturing process at any time, without
notice. Please check with your supplier or visit our web site to ensure that
you have the current and complete specification for your product before use.
© C&D Technologies (NCL) Limited 2003
NDC NDY.3
No part of this publication may be copied, transmitted or stored in a
retrieval system or reproduced in any way including, but not limited to,
photography, photocopy, magnetic or other recording means, without prior
written permission from C&D Technologies (NCL) Limited.
Instructions for use are available from www.cdpoweronline.com
COUT
OV
ENVIRONMENTAL
Parameter
+VOUT
C&D Technologies (NCL) Ltd
Tanners Drive, Blakelands North
Milton Keynes MK14 5BU, England
Tel: +44 (0)1908 615232
Fax: +44 (0)1908 617545
email: [email protected]
www.cdpoweronline.com
C&D Technologies Inc.
3400 E Britannia Drive, Tucson,
Arizona 85706, USA
Tel: +1 (800) 547-2537