CANDD QUS20-120

Converter
BUS DC/DC
CONVERTER
Programmable, Single Output, 1.1V - 1.85Vout @ 60A
48Vin, 12Vout @ 20A
Features
•
•
•
•
•
•
•
•
•
•
48vin, Isolated, 4:1 Fixed Conversion Ratio (12v Nominal Out)
240watt Max Output
Parallel For Higher Output Power
±10% Current Share Accuracy
Over-temperature Protection
96% Efficiency
Remote Enable (Primary Side)
Positive or Negative Enable Logic
Current Limit
Vertical Mount
This product is not fuse protected. User is responsible for providing system protection.
Consult factory for application information.
Table 1:
Input Characteristics
Notes and Conditions (1)
Input Voltage Operating Range
Min
Typ
Max
Units
36
48
55
Vdc
Input Voltage Absolute Maximum
Input Undervoltage Lockout
Maximum Input Current
60
Vdc
Turn-on Threshold
36.5
37.6
Vdc
Turn-off Threshold
34.5
35.5
Vdc
Steady-State (20Amp output)
5.1
Adc
No-Load Input Current
Enable state, on Load (48Vin)
72
mA
Disabled Input Current
Disabled State (48V input)
21
mA
Input Reflected Ripple Current (2)
50
Inrush Current Transient
0.20
mArms
A2s
Enable - Negative Logic Version
Internal 10K pull-up to 6.2V
On State Range
-0.6
0.7
Vdc
Off State Range
0.8
6.2
Vdc
Enable - Positive Logic Version
Internal 100K pull-down to gnd
On State Range
0.8
6.2
Vdc
Off State Range
-0.6
0.7
Vdc
Max
Units
Table 2:
Output Characteristics
Notes and Conditions (1)
Output Voltage Set Point
(Vin/4) +1% / -1%
Output Load Regulation
(Vin/4) + 1% / -5%
Output Voltage Total Regulation
Output Ripple Voltage & Noise (3)
Typ
12
-5
-3
8.5
20 MHz Bandwidth
Output Current Operating Range (4)
90
0
Efficiency
Io=20A, Vin=48V (See curves)
Turn-on Time
Vin present: Enable to 90% Vout
4118 14th Avenue, Suite 4
Markham, Ontario L3R 0J3
1-905-944-2850
Min
www.cd4power.com
QUS20-120_084-20868-40_RevB_Jan18-2006.fm
Vdc
1
%
13.9
Vdc
150
mVp-p
20
A
10
mS
95.6
%
4607 S.E. International Way
Milwaukie, Oregon 97222
1-971-206-2800
1 of 8
Converter
BUS DC/DC
CONVERTER
Programmable, Single Output, 1.1V - 1.85Vout @ 60A
48Vin, 12Vout @ 20A
Table 2:
Output Characteristics
Notes and Conditions (1)
Transient Response (5)
Maximum Output Capacitance
Min
Typ
Max
Units
5A Step 0.1A/µS, ∆Vo
150
mV
Recovery Time
100
µS
Max
3000
µF
Table 3:
Protection Characteristics
Notes and Conditions (1)
Output Overcurrent Inception Limit
Min
Typ
Max
Units
20
27
30
Adc
Output Overcurrent Shutdown
(Latching after second re-try)
Restart Rate
1700
Short Circuit Current
Peak
30
Apk
Overtemperature Shutdown
Non-Latching
125
°C
Overtemperature Restart Hysteresis
mS
10
°C
Table 4:
General Characteristics
Notes and Conditions (1)
Isolation Voltage
Input to Output
Isolation Resistance
Input to Output
10
Storage Temperature Range
Non-condensing
-40
125
°C
-40
85
°C
Operating Temperature Range
Agency Approvals
UL 60950-1, IEC 60950-1, TUV 60950-1
Material Flammability
UL 94V-0
MTBF
Calculated (RAC PRISM) 50°C
Dimensions
Vertical
Min
Typ
Max
Units
2000
Vdc
Mohm
1.52
x106 Hrs
2.50”L x 1.25”H x 0.380”W
Weight
35
g
Notes:
1. Vin = 48Vdc, Ta = 20°C, Airflow = 200LFM unless otherwise noted.
2. Input Reflected Ripple Current is specified when measured with a 120µF 63V electrolytic capacitor across the input pins.
3. Output Ripple Voltage is specified when measured with a 270µF electrolytic and a 10µF ceramic capacitor at the converter output pins.
4. De-rating curves are conducted in a controlled environment. End application testing is required to ensure the hot spot temperature is below the maximum specified.
5. Transient response is specified with 270µF electrolytic and 10µF ceramic at the converter output pins.
4118 14th Avenue, Suite 4
Markham, Ontario L3R 0J3
1-905-944-2850
www.cd4power.com
QUS20-120_084-20868-40_RevB_Jan18-2006.fm
4607 S.E. International Way
Milwaukie, Oregon 97222
1-971-206-2800
2 of 8
Converter
BUS DC/DC
CONVERTER
Programmable, Single Output, 1.1V - 1.85Vout @ 60A
48Vin, 12Vout @ 20A
Mechanical Information - Vertical
Figure 1
Pin Assignment - Vertical
Table 5:
Connector
J1
Pin #
Pin Name
1
ON/OFF
2
NC
3
VIN+
4
5
6
Pin #
Pin Name
1
VOUT-
Secondary return
2
VOUT+
Output, 12V nominal, 20A max
Vin 36 to 55Vdc
3
VOUT-
Secondary return
VIN-
Primary return
4
VOUT+
OUT
VIN+
Vin 36 to 55Vdc
5
VOUT-
Secondary return
VIN-
Primary return
6
VOUT+
OUT
7
VOUT-
Secondary return
8
VOUT+
OUT
4118 14th Avenue, Suite 4
Markham, Ontario L3R 0J3
1-905-944-2850
Function
Connector
Referenced to VinJ2
www.cd4power.com
QUS20-120_084-20868-40_RevB_Jan18-2006.fm
Function
4607 S.E. International Way
Milwaukie, Oregon 97222
1-971-206-2800
3 of 8
Converter
BUS DC/DC
CONVERTER
Programmable, Single Output, 1.1V - 1.85Vout @ 60A
48Vin, 12Vout @ 20A
Efficiency Curves
Efficiency vs Iout
98
Eff%
96
94
92
90
88
0
2
4
6
Vin = 36V
Vin = 42V
Vin = 48V
Vin = 55V
8 10 12 14 16 18 20 22 24
I out(A)
Figure 2
Vout vs. Load
Vout vs Iout
14
13
Vout (V)
12
11
10
9
8
7
6
0
2
4
6
Vin = 36V
Vin = 42V
Vin = 48V
Vin = 55V
8 10 12 14 16 18 20 22 24
I out(A)
Figure 3
4118 14th Avenue, Suite 4
Markham, Ontario L3R 0J3
1-905-944-2850
www.cd4power.com
QUS20-120_084-20868-40_RevB_Jan18-2006.fm
4607 S.E. International Way
Milwaukie, Oregon 97222
1-971-206-2800
4 of 8
Converter
BUS DC/DC
CONVERTER
Programmable, Single Output, 1.1V - 1.85Vout @ 60A
48Vin, 12Vout @ 20A
Derating - Vertical Mount
Vin = 36V
300LFM
400LFM
200LFM
30
25
20
15
20
30
40
50
60
70
80
90
Load Current (A)
Load Current (A)
200LFM
Vin = 55V
400LFM
27
25
23
21
19
17
15
20
Ambient Temp (C)
300LFM
30
40
50
60
70
80
90
Ambient Temp (C)
Vin = 42V
300LFM
400LFM
27
25
23
21
19
17
15
Output Power (W)
Load Current (A)
200LFM
Power Curves at 200LFM
Vin = 36V
Vin = 48V
20
30
40
50
60
70
80
Vin = 42V
Vin = 55V
280
230
180
130
90
20
Ambient Temp (C)
40
60
80
Ambient Temp (C)
Vin = 48V
Load Current (A)
200LFM
300LFM
400LFM
50
70
27
25
23
21
19
17
15
20
30
40
60
80
90
Ambient Temp (C)
Figure 4
4118 14th Avenue, Suite 4
Markham, Ontario L3R 0J3
1-905-944-2850
www.cd4power.com
QUS20-120_084-20868-40_RevB_Jan18-2006.fm
4607 S.E. International Way
Milwaukie, Oregon 97222
1-971-206-2800
5 of 8
Converter
BUS DC/DC
CONVERTER
Programmable, Single Output, 1.1V - 1.85Vout @ 60A
48Vin, 12Vout @ 20A
Start up from Enable
Vin = 48V, Iout = 20A
Vin = 48V, Iout = 0A
Figure 5
Transient Response
Iout 10A to 15A at 0.1A/µS
CH1 Vout 50mV/div, CH2 Iout 5A/div
Figure 6
4118 14th Avenue, Suite 4
Markham, Ontario L3R 0J3
1-905-944-2850
www.cd4power.com
QUS20-120_084-20868-40_RevB_Jan18-2006.fm
4607 S.E. International Way
Milwaukie, Oregon 97222
1-971-206-2800
6 of 8
Converter
BUS DC/DC
CONVERTER
Programmable, Single Output, 1.1V - 1.85Vout @ 60A
48Vin, 12Vout @ 20A
Output Voltage Ripple
Vin = 48V, Iout = 20A; BW = 20MHz
Figure 7
Input Ripple
Vin = 48V, Iout = 20A; BW = 20MHz 5mA/div
Figure 8
4118 14th Avenue, Suite 4
Markham, Ontario L3R 0J3
1-905-944-2850
www.cd4power.com
QUS20-120_084-20868-40_RevB_Jan18-2006.fm
4607 S.E. International Way
Milwaukie, Oregon 97222
1-971-206-2800
7 of 8
Converter
BUS DC/DC
CONVERTER
Programmable, Single Output, 1.1V - 1.85Vout @ 60A
48Vin, 12Vout @ 20A
Ordering Information
QUS20-120-NVDRC
Quarter Brick Outline
RoHS Compliant Option
Unregulated
Default
Single Output
Pin Length(L)
D = 0.180”
Output Current (20A)
Output Voltage (12V)
H = Horizontal
V = Vertical
P = Positive Enable Logic
N = Negative Enable Logic
RoHS Compliancy
The QUS20-120-NVRDC is in compliance with the European Union Directive 2002/95/EC (RoHS) with
respect to the following substances: lead (Pb), cadmium (Cd), mercury (Hg), hexavalent chromium (Cr6),
polybrominated biphenyls (PBB) or polybrominated diphenyl ethers (PBDE).
RoHS Process Note
This product is not intended to go through a reflow solder process. Use wave solder, selective solder or
hand solder process with a peak temperature of 260°C for 10 seconds.
C&D Technologies, Inc. reserves the right to alter or improve the specification, internal design or manufacturing process at any time, without notice.
Please check with your supplier or visit our website to ensure that you have the current and complete specification for your product before use.
© C&D Technologies, Inc. 2004
No part of this publication may be copied, transmitted, or stored in a retrieval system or reproduced in any way including, but not limited to,
photography, photocopy, magnetic or other recording means, without prior written permission from C&D Technologies, Inc.
Instructions for use are available from: www.cd4power.com
4118 14th Avenue, Suite 4
Markham, Ontario L3R 0J3
1-905-944-2850
www.cd4power.com
QUS20-120_084-20868-40_RevB_Jan18-2006.fm