EMERSON-NETWORKPOWER AIF120Y300

Embedded Power for
Business-Critical Continuity
Rev. 05.23.07
AIF Series
1 of 2
AIF Series
RoHS
600 Watts
Total Power:
600 Watts
(12V@50Amps)
Input Voltage: 300V
# of Outputs: Single
Electrical Specifications
Input
Special Features
• 600W Continuous power at
100°C baseplate temperature
• 108W/in3 (6.6W/cm3)
• High efficiency - up to 90%
• Low output ripple and noise
• Positive and Negative enable
function
• Excellent transient response
• OVP, OCP, V Adj control with
ALPTM analog mode linear
control, or through I2C bus
with digital mode control.
• Paralleable with accurate
current sharing
• EU Directive 2002/95/EC
compliant for RoHS
250 - 420 VDC
450V / 100ms
90%@5.0V (Typical)
Output
Load Regulation
Line Regulation
Noise / Ripple
Remote sense
0.2% typical down to no load
0.2% typical
100mV typical (below 5V); 2% typical (5V and above)
Up to 0.5V
Output voltage adjust range
+/-20% for 5V and above; +10%/ -50% for below 5V
Transient Response
5% max for 3.3V and above, 150mV for 1.8V, deviation with 25%
to 75% full load 250 μS (max) recovery
3% typical
115% Vo (nominal)
115% Io maximum
Current Share Accuracy
Overvoltage Protection
Current Limit
Control
Voltage Adjust
80 to 120% Vo linear programming for 12V, 15V, 24V, 48V 50%
to 110% for 1.8V - 5.0V
Enable
TTL compatible (positive & negative enable options)
Current Limit Adjust
20 to 100% Io linear programming or digital mode control
Clock Input (external sync)
3.3 to 5.5Vp-p @ 800KHz ±10%
Clock Output (internal clock) 4.5Vp-p typical@ 800KHz ±5%
Power Good Identification
High (Vo) = power good
Temperature Monitor Output 10mV/°K (2.73 = 0°C)
Current Monitor Output
0 to 1mA (1mA = 100% Io rated)
Over Voltage Protection
Adjust
Safety
UL
cUL
TUV
CE
Input range
Input surge
Efficiency
110 to 150% Vo linear programming by voltage or resistor,
or digital mode control
Notes
60950 Recognized
60950 Recognized
EN60950 Licensed
CE Mark
Nominal values apply with sense pins connected and other control pin unconnected.
ALP: Astec Linear Programming
Embedded Power for
Business-Critical Continuity
Americas
Environmental Specifications
Operating temperature
Start up temperature
Storage temperature
Overtemperature protection
Input Voltage Output Voltage Efficiency
300V
1.8V @ 120A
80% (Typ)
300V
3.3V @ 120A
87% (Typ)
300V
5.0V @ 80A
90% (Typ)
300V
12V @ 50A
90% (Typ)
300V
15V @ 40A
90% (Typ)
300V
24V @ 25A
90% (Typ)
1. For Negative enable, add suffix “-N”.
2. For Non-thread hole, add suffix “-NT”.
3. For RoHS 6, add suffix “-L”. Default is RoHS 5.
Mechanical Drawing
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
-20°C to +100°C (case temperature)
-40°C to +100°C (case temperature)
-40°C to +125°C
110°C max
Europe (UK)
Pin Assignments
Ordering Information
Model Number
AIF120Y300
AIF120F300
AIF80A300
AIF50B300
AIF40C300
AIF25H300
Input (AC)
Rev. 05.23.07
AIF Series
2 of 2
Output (DC)
31. Positive 21. Positive
32. Negative 22. Positive
Control Pins
1. +Sense
2. Temp Mon
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
23. Positive
24. Positive
25. Negative
3. C Mon
4. C Share
5. Clk Out
26. Negative
6. Clk In
Asia (HK)
27. Negative
28. Negative
7. PG/ID
8. C Lim Adj
9. OVP Adj
10. V Adj
11. Enable
12. -Sense
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.astecpower.com
www.artesyn.com
[email protected]
[email protected]
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2005 Emerson Electric Co.