EMERSON-NETWORKPOWER EXB50

EXB50 Series
Single output
DC-DC CONVERTERS
20-50 W High Efficiency DC-DC Converters
1
• High efficiency topology, 91% typical on EXB50-48S05J
• Industry standard footprint
• Wide operating temperature -40 °C to +70 °C
(natural convection)
• 60% to 110% output trim
• No minimum load
• Overvoltage and overtemperature protection
• Remote sense compensation
• Remote ON/OFF
• Available RoHS compliant
The EXB50 series of 50 Watt single-output isolated dc-dc converters are specifically
designed to meet the power needs of low-voltage silicon. Housed in an open-frame
package with an industry-standard footprint, these latest-generation converters offer
efficiencies as high as 91%. The series comprises three 24 V input models with 5 V,
3.3 V and 2 V outputs, and six 48 V input models with 12 V, 5 V, 3.3 V 2.5 V, 2 V and
1.8 V outputs. All models feature a wide input range, trimmable output voltage and a
10 A current rating (except the 12 V). Remote sense and remote ON/OFF facilities are
included as standard, and the converters are comprehensively protected against
overcurrent, overvoltage and overtemperature conditions.
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
OUTPUT SPECIFICATIONS
INPUT SPECIFICATIONS Continued
Voltage adjustability
60% to 110%
Setpoint accuracy
Line regulation
Low line to high line
0.1% max.
Load regulation
Full load to min. load
0.2% max.
Total error band
±3.0%
Minimum load
Overshoot
0%
At turn-on and turn-off
Undershoot
None
None
Ripple and noise
(See Note 1)
5 Hz to 20 MHz
Transient response
(See Notes 2 and 8)
24 V models
48 V models
Remote sense
(See Note 9)
100 mV pk-pk
20 mV rms
3.0% peak deviation
2.0% peak deviation,
200 µs recovery to
within total error band
10% o/p voltage change
INPUT SPECIFICATIONS
Input voltage range
(See Note 14)
Input current
Input current (max.)
(See Note 4)
Undervoltage lockout
24
24
48
48
Start-up time
(See Note 7)
Power up
Remote ON/OFF
±1.5% max.
24 V nominal
48 V nominal
100 V 100 ms transient
24
24
48
48
V no load
V Remote OFF
V no load
V Remote OFF
24 V models
18-36 Vdc
36-75 Vdc
V
V
V
V
Power
Power
Power
Power
up
down
up
down
17 V max.
15 V min.
33.2 V max.
30.9 V min.
30 ms
25 ms
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
Immunity:
ESD air
ESD contact
Radiated field enclosure
Conducted (DC power)
Conducted (signal)
EN55022 (See Note 3)
Level A
EN55022 (See Note 3)
Level B
EN55022
Level A
(See Note 13)
EN61000-4-2 8 kV (NP), 15 kV (RP)
EN61000-4-2 6 kV (NP), 8 kV (RP)
EN61000-4-3 10 V/m (NP)
EN61000-4-6 10 V (NP)
EN61000-4-6 10 V (NP)
GENERAL SPECIFICATIONS
Efficiency
See table
Basic insulation
Input/output
Switching frequency
Fixed
Approvals and
standards (See Note 5)
1500 Vdc
300 kHz typ.
IEC60950/EN60950, UL/cUL1950
CSA C22.2 No. 950
Material flammability
85 mA max.
20 mA max.
60 mA max.
10 mA max.
48 V models
3.25 A max. @ Io max.
and Vin = 18-36 Vdc
1.7 A max. @ lo max.
and Vin = 36-75 Vdc
Input reflected ripple
(See Note 6)
24 V models
48 V models
20 mA (pk-pk) typ.
50 mA (pk-pk) typ.
Remote ON/OFF
Logic compatibility
ON
OFF
(See Note 15)
Open collector ref to -input
Open circuit or >2 Vdc
<1.2 Vdc
UL94V-0
Weight
MTBF
50 g (1.77 oz)
MIL-HDBK-217F @ 25 ºC
100% load ground benign
270,000
hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
(See Notes 11, 12)
ETS 300 019-2-3
Altitude
(See Note 10)
Operating ambient.
-40 °C to +70 °C
temperature (natural convection)
Non-operating
-55 °C to +125 °C
Classes T3.1 to T3.5
3,000 metres
10,000 metres
Derate max. output
current by 20%
Derate max. output
current by 50%
File Name: exb50s.pdf Rev (02): 05 Dec 2005
EXB50 Series
Single output
DC-DC CONVERTERS
20-50 W High Efficiency DC-DC Converters
2
For the most current data and application support visit www.artesyn.com/html/products.html
OUTPUT
POWER
(MAX.)
INPUT
VOLTAGE
OVP
OUTPUT
VOLTAGE
OUTPUT
CURRENT
(MIN.)
OUTPUT
CURRENT
(MAX.)
EFFICIENCY
(TYP.)
LINE
LOAD
MODEL
NUMBER (16,17)
20 W
18-36 Vdc
2.4 Vdc
2V
0A
10 A
86.5%
±0.1%
±0.2%
EXB50-24S2V0J
33 W
18-36 Vdc
3.9 Vdc
3.3 V
0A
10 A
89.0%
±0.1%
±0.2%
EXB50-24S3V3J(14)
50 W
18-36 Vdc
6 Vdc
5V
0A
10 A
90.0%
±0.1%
±0.2%
EXB50-24S05J
18 W
36-75 Vdc
2.15 Vdc
1.8 V
0A
10 A
85.7%
±0.1%
±0.2%
EXB50-48S1V8J(15)
20 W
36-75 Vdc
2.45 Vdc
2V
0A
10 A
87.5%
±0.1%
±0.2%
EXB50-48S2V0J(15)
25 W
36-75 Vdc
2.95 Vdc
2.5 V
0A
10 A
87.5%
±0.1%
±0.2%
EXB50-48S2V5J(15)
33 W
36-75 Vdc
4 Vdc
3.3 V
0A
10 A
90.0%
±0.1%
±0.2%
EXB50-48S3V3J(14,15)
50 W
36-75 Vdc
6.15 Vdc
5V
0A
10 A
91.0%
±0.1%
±0.2%
EXB50-48S05J(15)
50 W
36-75 Vdc
14.2 Vdc
12 V
0A
4.2 A
90.0%
±0.1%
±0.2%
EXB50-48S12J(15)
REGULATION
Notes
Notes Continued
1
12 Wide operating temperature on the EXB50-24S05J is -40 ºC to +60 ºC.
13 Input transient (48 V) ETS300 132-2 ETR283.
14 100 V, 100 ms transient applies to the EXB50-24S3V3J and the EXB5048S3V3J models. Please add the suffix 'R03' to the model number e.g.
EXB50-48S3V3R03J. This is also active low remote ON/OFF.
15 Active low remote ON/OFF available. Please add suffix '-R' to model
number e.g. EXB50-48S3V3-RJ.
16 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
17 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
Measured as per recommended set-up. 150 mV pk-pk for EXB5048S12J.
2 di/dt = 0.1 A/µs, Vin = 24/48 Vdc, Tc = 25 °C, load change = 0.5 lo max.
to 0.75 lo max. and 0.75 lo max. to 0.5 lo max.
3 The EXB50 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
4 Recommended input fusing is a 6.3 A HRC 200 V rated fuse on the 24 V
and 3.15 A HRC 200 V rated fuse on the 48 V.
5 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
6 Simulated source impedance of 12 µH. 12 µH inductor in series with
+Vin.
7 Start-up into resistive load.
8 EXB50-24S2V0J model has 5.0% max. deviation and 300 µs recovery.
9 Maximum output deviation is 10% inclusive of trim.
10 Contact factory for operation at higher altitude.
11 See Application Note 113 for derating curves.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
PROTECTION
EXTERNAL OUTPUT TRIMMING
Short-circuit
Continuous
Over-voltage
Non-latching clamp
Thermal
120 ºC hot spot temperature with
automatic recovery
Output can be externally trimmed
by using the method shown below.
+ Sense
TRIM
UP
TELECOM SPECIFICATION
Central office interface A
ETS300-132-2, input voltage
and current requirements
Trim
TRIM
DOWN
RT1
or
RT2
- Sense
International Safety Standard Approvals
UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950
File No. E174104
TÜV Product Service. Certificate No. B 03 08 38572 036
File Name: exb50s.pdf Rev (02): 05 Dec 2005
EXB50 Series
Single output
DC-DC CONVERTERS
20-50 W High Efficiency DC-DC Converters
3
0.16±0.02
(4.10±0.5)
Ø0.079±0.002
(Ø2.03±0.05)
0.50
(12.70)
BOTTOM
VIEW
3
4
7
6
2.40 ±0.02
(60.96 ±0.5)
8
1.40
(35.56)
9
1.00
(25.40)
1.40
(35.56)
2.00
(50.80)
1
1.00
(25.40)
STAND-OFFS
4 PLACES
0.70
(17.78)
0.20
(5.08)
Ø0.040 ±0.02
(Ø1.02 ±0.05)
0.40
(10.16)
0.43±0.02
(10.90±0.5)
OPEN-FRAME
HEIGHT
0.02
(0.50)
0.138±0.02
(3.50±0.5)
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
5
1.90
(48.26)
ALL DIMENSIONS IN INCHES (mm)
0.19
(4.83)
2.28 ±0.02
(57.91 ±0.5)
General Tolerance ±0.010 (0.25)
Unless Otherwise Specified
PIN CONNECTIONS
PIN NUMBER
FUNCTION
1
-Vin
2
No Pin
3
Remote ON/OFF
4
+Vin
5
+Vout
6
+Sense
7
Trim
8
-Sense
9
-Vout
Datasheet © Artesyn Technologies® 2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: Application Note Longform Datasheet
www.artesyn.com
File Name: exb50s.pdf Rev (02): 05 Dec 2005