EON EN29GL064T

Preliminary
EN29GL064
EN29GL064
64 Megabit (8192K x 8-bit / 4096K x 16-bit) Flash Memory
Page mode Flash Memory, CMOS 3.0 Volt-only
FEATURES
• Suspend and Resume commands for
Program and Erase operations
• Single power supply operation
- Full voltage range: 2.7 to 3.6 volts read and
write operations
• Write operation status bits indicate program
and erase operation completion
• High performance
- Access times as fast as 70 ns
• Support for CFI (Common Flash Interface)
• VIO Input/Output 1.65 to 3.6 volts
- All input levels (address, control, and DQ input
levels) and outputs are determined by voltage
on VIO input. VIO range is 1.65 to VCC
• Persistent methods of Advanced Sector
Protection
• WP#/ACC input
• 8-word/16-byte page read buffer
- Accelerates programming time (when VHH is
applied) for greater throughput during system
production
• 16-word/32-byte write buffer reduces overall
programming time for multiple-word updates
- Protects first or last sector regardless of
sector protection settings
• Secured Silicon Sector region
- 128-word/256-byte sector for permanent,
secure identification through an 8-word/16byte random Electronic Serial Number
- Can be programmed and locked at the factory
or by the customer
• Hardware reset input (RESET#) resets device
• Ready/Busy# output (RY/BY#) detects
program or erase cycle completion
• Minimum 100K program/erase endurance
cycles.
• Flexible Sector Architecture:
- Uniform sector models:
One hundred and twenty-eight uniform
32Kword/64Kbyte sectors
- Boot sector models:
Eight 8-Kbyte boot sectors on Top or Bottom
and one hundred twenty-seven 32Kword /
64Kbyte sectors.
•
-
Package Options
48-pin TSOP
56-pin TSOP
64-ball Fortified BGA
• Industrial Temperature Range.
GENERAL DESCRIPTION
The EN29GL064 offers a fast page access time of 25 ns with a corresponding random access time as
fast as 70 ns. It features a Write Buffer that allows a maximum of 16 words/32 bytes to be programmed
in one operation, resulting in faster effective programming time than standard programming algorithms.
This makes the device ideal for today’s embedded applications that require higher density, better
performance and lower power consumption.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
1
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
CONNECTION DIAGRAMS
Figure 1. 48-pin Standard TSOP (Top View)
A15
A14
A13
A12
A11
A10
A9
A8
A19
A20
WE#
RESET#
A21
WP#/ACC
RY/BY#
A18
A17
A7
A6
A5
A4
A3
A2
A1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
A16
BYTE#
Vss
DQ15/A-1
DQ7
DQ14
DQ6
DQ13
DQ5
DQ12
DQ4
Vcc
DQ11
DQ3
DQ10
DQ2
DQ9
DQ1
DQ8
DQ0
OE#
Vss
CE#
A0
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
Figure 2. 56-pin Standard TSOP (Top View)
RFU
RFU
A15
A14
A13
A12
A11
A10
A9
A8
A19
A20
WE#
RESET#
A21
WP#/ACC
RY/BY#
A18
A17
A7
A6
A5
A4
A3
A2
A1
RFU
RFU
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
RFU
RFU
A16
BYTE#
Vss
DQ15/A-1
DQ7
DQ14
DQ6
DQ13
DQ5
DQ12
DQ4
Vcc
DQ11
DQ3
DQ10
DQ2
DQ9
DQ1
DQ8
DQ0
OE#
Vss
CE#
A0
RFU
VIO
Note: RFU= Reserved for future use
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
2
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Figure 3. 64-ball Fortified Ball Grid Array (Top View, Balls Facing Down)
A8
B8
C8
RFU
RFU
RFU
A7
B7
C7
A13
A12
A6
E8
F8
G8
H8
VSS
RFU
RFU
RFU
D7
E7
F7
G7
H7
A14
A15
A16
B6
C6
D6
E6
F6
G6
H6
A9
A8
A10
A11
DQ7
DQ14
DQ13
DQ6
A5
B5
C5
D5
E5
F5
G5
H5
WE#
RESET#
A21
A19
DQ5
DQ12
VCC
DQ4
A4
B4
C4
D4
E4
F4
G4
H4
WP# / ACC
A18
A20
DQ2
DQ10
DQ11
DQ3
A3
B3
C3
D3
E3
F3
G3
H3
A7
A17
A6
A5
DQ0
DQ8
DQ9
DQ1
A2
B2
C2
D2
E2
F2
G2
H2
A3
A4
A2
A1
A0
CE#
OE#
VSS
A1
B1
C1
D1
E1
F1
G1
H1
RFU
RFU
RFU
RFU
RFU
RFU
RFU
RY / BY#
D8
VIO
BYTE# DQ15 / A -1
VIO
VSS
Note: RFU= Reserved for future use
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
3
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
TABLE 1. PIN DESCRIPTION
Pin Name
EN29GL064
FIGURE 4. LOGIC DIAGRAM
Function
EN29GL064
A21–A0
A21–A0
DQ0-DQ14
Data input/output.
DQ15 / A-1
DQ15 (data input/output, word mode),
A-1 (LSB address input, byte mode)
CE#
Chip Enable
OE#
Output Enable
RESET#
Hardware Reset Pin
RY/BY#
Ready/Busy Output
WE#
Write Enable
Vcc
Supply Voltage (2.7-3.6V)
Vss
Ground
VIO
V I/O Input.
BYTE#
Byte/Word mode selection
WP#/ACC
Write Protect / Acceleration Pin
RFU
Reserved for future use.
Not Connected to anything
DQ0 – DQ15
(A-1)
A0 – A21
Reset#
CE#
OE#
WE#
RY/BY#
Byte#
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
4
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Table 2. PRODUCT SELECTOR GUIDE
Product Number
EN29GL064
Full Voltage Range: Vcc=2.7 – 3.6 V
VIO=1.65 – 3.6 V
Speed Option
-70
Max Access Time, ns (tacc)
70
Max Page Read Access, ns(tpacc)
25
Max CE# Access, ns (tce)
70
Max OE# Access, ns (toe)
30
BLOCK DIAGRAM
RY/BY#
Vcc
Vss
VIO
DQ0-DQ15 (A-1)
Block Protect Switches
Erase Voltage Generator
Input/Output Buffers
State
Control
WE#
Command
Register
Program Voltage
Generator
Chip Enable
Output Enable
Logic
CE#
OE#
Vcc Detector
Timer
Address Latch
STB
STB
Data Latch
Y-Decoder
Y-Gating
X-Decod er
Cell Matrix
A0-AMax
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
5
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Product Overview
EN29GL064 is 64 Mb, 3.0-volt-only, page mode Flash devices optimized for today’s embedded designs
that demand a large storage array and rich functionality. This product offers uniform 32 Kword (64 KB)
uniform sectors and Top or Bottom boot sectors device (for 48-pin TSOP only offer Top or Bottom boot
sectors device). The feature of V I/O control allowing control and I/O signals to operate from 1.65 V to
VCC. Additional features include:
• Single word programming or a 16-word buffer for an increased programming speed
• Program Suspend/Resume and Erase Suspend/Resume
• Advanced Sector Protection methods for protecting sectors as required
• 128 words/256 bytes of Secured Silicon area for storing customer and factory secured information.
The Secured Silicon Sector is One Time Programmable.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
6
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Table 3A. Uniform Sector / Persistent Protection Sector Group Address Tables
(EN29GL064H/L)
PPB
Group
PPB 0
Address Range
Byte mode (x8)
000000h 00FFFFh
Address Range
Word mode (x16)
000000h 007FFFh
64/32
010000h
01FFFFh
008000h
00FFFFh
0000010
64/32
020000h
02FFFFh
010000h
017FFFh
0000011
64/32
030000h
03FFFFh
018000h
01FFFFh
04FFFFh
020000h
027FFFh
Sector
A21–A15
SA0
0000000
Sector Size
(Kbytes/Kwords)
64/32
PPB 1
SA1
0000001
PPB 2
SA2
PPB 3
SA3
PPB 4
PPB 5
PPB 6
PPB 7
PPB 8
PPB 9
PPB 10
PPB 11
PPB 12
SA4
0000100
64/32
040000h
SA5
0000101
64/32
050000h
05FFFFh
028000h
02FFFFh
SA6
0000110
64/32
060000h
06FFFFh
030000h
037FFFh
SA7
0000111
64/32
070000h
07FFFFh
038000h
03FFFFh
SA8
0001000
64/32
080000h
08FFFFh
040000h
047FFFh
SA9
0001001
64/32
090000h
09FFFFh
048000h
04FFFFh
SA10
0001010
64/32
0A0000h
0AFFFFh
050000h
057FFFh
SA11
0001011
64/32
0B0000h
0BFFFFh
058000h
05FFFFh
SA12
0001100
64/32
0C0000h
0CFFFFh
060000h
067FFFh
0DFFFFh
068000h
06FFFFh
SA13
0001101
64/32
0D0000h
SA14
0001110
64/32
0E0000h
0EFFFFh
070000h
077FFFh
SA15
0001111
64/32
0F0000h
0FFFFFh
078000h
07FFFFh
SA16
0010000
64/32
100000h
10FFFFh
080000h
087FFFh
SA17
0010001
64/32
110000h
11FFFFh
088000h
08FFFFh
SA18
0010010
64/32
120000h
12FFFFh
090000h
097FFFh
SA19
0010011
64/32
130000h
13FFFFh
098000h
09FFFFh
SA20
0010100
64/32
140000h
14FFFFh
0A0000h
0A7FFFh
15FFFFh
0A8000h
0AFFFFh
SA21
0010101
64/32
150000h
SA22
0010110
64/32
160000h
16FFFFh
0B0000h
0B7FFFh
SA23
0010111
64/32
170000h
17FFFFh
0B8000h
0BFFFFh
SA24
0011000
64/32
180000h
18FFFFh
0C0000h
0C7FFFh
SA25
0011001
64/32
190000h
19FFFFh
0C8000h
0CFFFFh
SA26
0011010
64/32
1A0000h
1AFFFFh
0D0000h
0D7FFFh
SA27
0011011
64/32
1B0000h
1BFFFFh
0D8000h
0DFFFFh
SA28
0011100
64/32
1C0000h
1CFFFFh
0E0000h
0E7FFFh
SA29
0011101
64/32
1D0000h
1DFFFFh
0E8000h
0EFFFFh
1EFFFFh
0F0000h
0F7FFFh
SA30
0011110
64/32
1E0000h
SA31
0011111
64/32
1F0000h
1FFFFFh
0F8000h
0FFFFFh
SA32
0100000
64/32
200000h
20FFFFh
100000h
107FFFh
SA33
0100001
64/32
210000h
21FFFFh
108000h
10FFFFh
SA34
0100010
64/32
220000h
22FFFFh
110000h
117FFFh
SA35
0100011
64/32
230000h
23FFFFh
118000h
11FFFFh
SA36
0100100
64/32
240000h
24FFFFh
120000h
127FFFh
SA37
0100101
64/32
250000h
25FFFFh
128000h
12FFFFh
SA38
0100110
64/32
260000h
26FFFFh
130000h
137FFFh
64/32
270000h
27FFFFh
138000h
13FFFFh
SA39
0100111
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
7
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
PPB 13
PPB 14
PPB 15
PPB 16
PPB 17
PPB 18
PPB 19
PPB 20
PPB 21
PPB 22
PPB 23
EN29GL064
SA40
0101000
64/32
280000h
28FFFFh
140000h
147FFFh
SA41
0101001
64/32
290000h
29FFFFh
148000h
14FFFFh
SA42
0101010
64/32
2A0000h
2AFFFFh
150000h
157FFFh
SA43
0101011
64/32
2B0000h
2BFFFFh
158000h
15FFFFh
SA44
0101100
64/32
2C0000h
2CFFFFh
160000h
167FFFh
SA45
0101101
64/32
2D0000h
2DFFFFh
168000h
16FFFFh
2EFFFFh
170000h
177FFFh
SA46
0101110
64/32
2E0000h
SA47
0101111
64/32
2F0000h
2FFFFFh
178000h
17FFFFh
SA48
0110000
64/32
300000h
30FFFFh
180000h
187FFFh
SA49
0110001
64/32
310000h
31FFFFh
188000h
18FFFFh
SA50
0110010
64/32
320000h
32FFFFh
190000h
197FFFh
SA51
0110011
64/32
330000h
33FFFFh
198000h
19FFFFh
SA52
0110100
64/32
340000h
34FFFFh
1A0000h
1A7FFFh
SA53
0110101
64/32
350000h
35FFFFh
1A8000h
1AFFFFh
SA54
0110110
64/32
360000h
36FFFFh
1B0000h
1B7FFFh
37FFFFh
1B8000h
1BFFFFh
SA55
0110111
64/32
370000h
SA56
0111000
64/32
380000h
38FFFFh
1C0000h
1C7FFFh
SA57
0111001
64/32
390000h
39FFFFh
1C8000h
1CFFFFh
SA58
0111010
64/32
3A0000h
3AFFFFh
1D0000h
1D7FFFh
SA59
0111011
64/32
3B0000h
3BFFFFh
1D8000h
1DFFFFh
SA60
0111100
64/32
3C0000h
3CFFFFh
1E0000h
1E7FFFh
SA61
0111101
64/32
3D0000h
3DFFFFh
1E8000h
1EFFFFh
SA62
0111110
64/32
3E0000h
3EFFFFh
1F0000h
1F7FFFh
SA63
0111111
64/32
3F0000h
3FFFFFh
1F8000h
1FFFFFh
40FFFFh
200000h
207FFFh
SA64
1000000
64/32
400000h
SA65
1000001
64/32
410000h
41FFFFh
208000h
20FFFFh
SA66
1000010
64/32
420000h
42FFFFh
210000h
217FFFh
SA67
1000011
64/32
430000h
43FFFFh
218000h
21FFFFh
SA68
1000100
64/32
440000h
44FFFFh
220000h
227FFFh
SA69
1000101
64/32
450000h
45FFFFh
228000h
22FFFFh
SA70
1000110
64/32
460000h
46FFFFh
230000h
237FFFh
SA71
1000111
64/32
470000h
47FFFFh
238000h
23FFFFh
SA72
1001000
64/32
480000h
48FFFFh
240000h
247FFFh
SA73
1001001
64/32
490000h
49FFFFh
248000h
24FFFFh
4AFFFFh
250000h
257FFFh
SA74
1001010
64/32
4A0000h
SA75
1001011
64/32
4B0000h
4BFFFFh
258000h
25FFFFh
SA76
1001100
64/32
4C0000h
4CFFFFh
260000h
267FFFh
SA77
1001101
64/32
4D0000h
4DFFFFh
268000h
26FFFFh
SA78
1001110
64/32
4E0000h
4EFFFFh
270000h
277FFFh
SA79
1001111
64/32
4F0000h
4FFFFFh
278000h
27FFFFh
SA80
1010000
64/32
500000h
50FFFFh
280000h
287FFFh
SA81
1010001
64/32
510000h
51FFFFh
288000h
28FFFFh
SA82
1010010
64/32
520000h
52FFFFh
290000h
297FFFh
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
8
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
PPB 24
PPB 25
PPB 26
PPB 27
PPB 28
PPB 29
PPB 30
PPB 31
PPB 32
PPB 33
PPB 34
PPB 35
EN29GL064
SA83
1010011
64/32
530000h
53FFFFh
298000h
29FFFFh
SA84
1010100
64/32
540000h
54FFFFh
2A0000h
2A7FFFh
SA85
1010101
64/32
550000h
55FFFFh
2A8000h
2AFFFFh
SA86
1010110
64/32
560000h
56FFFFh
2B0000h
2B7FFFh
SA87
1010111
64/32
570000h
57FFFFh
2B8000h
2BFFFFh
SA88
1011000
64/32
580000h
58FFFFh
2C0000h
2C7FFFh
SA89
1011001
64/32
590000h
59FFFFh
2C8000h
2CFFFFh
SA90
1011010
64/32
5A0000h
5AFFFFh
2D0000h
2D7FFFh
5BFFFFh
2D8000h
2DFFFFh
SA91
1011011
64/32
5B0000h
SA92
1011100
64/32
5C0000h
5CFFFFh
2E0000h
2E7FFFh
SA93
1011101
64/32
5D0000h
5DFFFFh
2E8000h
2EFFFFh
SA94
1011110
64/32
5E0000h
5EFFFFh
2F0000h
2F7FFFh
SA95
1011111
64/32
5F0000h
5FFFFFh
2F8000h
2FFFFFh
SA96
1100000
64/32
600000h
60FFFFh
300000h
307FFFh
SA97
1100001
64/32
610000h
61FFFFh
308000h
30FFFFh
SA98
1100010
64/32
620000h
62FFFFh
310000h
317FFFh
SA99
1100011
64/32
630000h
63FFFFh
318000h
31FFFFh
SA100
1100100
64/32
640000h
64FFFFh
320000h
327FFFh
SA101
1100101
64/32
650000h
65FFFFh
328000h
32FFFFh
SA102
1100110
64/32
660000h
66FFFFh
330000h
337FFFh
67FFFFh
338000h
33FFFFh
SA103
1100111
64/32
670000h
SA104
1101000
64/32
680000h
68FFFFh
340000h
347FFFh
SA105
1101001
64/32
690000h
69FFFFh
348000h
34FFFFh
SA106
1101010
64/32
6A0000h
6AFFFFh
350000h
357FFFh
SA107
1101011
64/32
6B0000h
6BFFFFh
358000h
35FFFFh
SA108
1101100
64/32
6C0000h
6CFFFFh
360000h
367FFFh
SA109
1101101
64/32
6D0000h
6DFFFFh
368000h
36FFFFh
SA110
1101110
64/32
6E0000h
6EFFFFh
370000h
377FFFh
SA111
1101111
64/32
6F0000h
6FFFFFh
378000h
37FFFFh
SA112
1110000
64/32
700000h
70FFFFh
380000h
387FFFh
SA113
1110001
64/32
710000h
71FFFFh
388000h
38FFFFh
72FFFFh
390000h
397FFFh
SA114
1110010
64/32
720000h
SA115
1110011
64/32
730000h
73FFFFh
398000h
39FFFFh
SA116
1110100
64/32
740000h
74FFFFh
3A0000h
3A7FFFh
SA117
1110101
64/32
750000h
75FFFFh
3A8000h
3AFFFFh
SA118
1110110
64/32
760000h
76FFFFh
3B0000h
3B7FFFh
SA119
1110111
64/32
770000h
77FFFFh
3B8000h
3BFFFFh
SA120
1111000
64/32
780000h
78FFFFh
3C0000h
3C7FFFh
SA121
1111001
64/32
790000h
79FFFFh
3C8000h
3CFFFFh
SA122
1111010
64/32
7A0000h
7AFFFFh
3D0000h
3D7FFFh
SA123
1111011
64/32
7B0000h
7BFFFFh
3D8000h
3DFFFFh
SA124
1111100
64/32
7C0000h
7CFFFFh
3E0000h
3E7FFFh
64/32
7D0000h
7DFFFFh
3E8000h
3EFFFFh
SA125
1111101
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
9
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
PPB 36
SA126
1111110
64/32
7E0000h
7EFFFFh
3F0000h
3F7FFFh
PPB 37
SA127
1111111
64/32
7F0000h
7FFFFFh
3F8000h
3FFFFFh
Table 3B. Top Boot Sector / Persistent Protection Sector Group Address Tables
(EN29GL064T)
PPB
Group
PPB 0
PPB 1
PPB 2
PPB 3
PPB 4
PPB 5
PPB 6
PPB 7
PPB 8
PPB 9
Sector
A21 – A12
Sector Size
(Kbytes / Kwords)
Address Range (h)
Byte mode (x8)
Address Range (h)
Word Mode (x16)
SA0
0000000xxx
64/32
000000–00FFFF
000000–007FFF
SA1
0000001xxx
64/32
010000–01FFFF
008000–00FFFF
SA2
0000010xxx
64/32
020000–02FFFF
010000–017FFF
SA3
0000011xxx
64/32
030000–03FFFF
018000–01FFFF
SA4
0000100xxx
64/32
040000–04FFFF
020000–027FFF
SA5
0000101xxx
64/32
050000–05FFFF
028000–02FFFF
SA6
0000110xxx
64/32
060000–06FFFF
030000–037FFF
SA7
0000111xxx
64/32
070000–07FFFF
038000–03FFFF
SA8
0001000xxx
64/32
080000–08FFFF
040000–047FFF
SA9
0001001xxx
64/32
090000–09FFFF
048000–04FFFF
SA10
0001010xxx
64/32
0A0000–0AFFFF
050000–057FFF
SA11
0001011xxx
64/32
0B0000–0BFFFF
058000–05FFFF
SA12
0001100xxx
64/32
0C0000–0CFFFF
060000–067FFF
SA13
0001101xxx
64/32
0D0000–0DFFFF
068000–06FFFF
SA14
0001110xxx
64/32
0E0000–0EFFFF
070000–077FFF
SA15
0001111xxx
64/32
0F0000–0FFFFF
078000–07FFFF
SA16
0010000xxx
64/32
100000–10FFFF
080000–087FFF
SA17
0010001xxx
64/32
110000–11FFFF
088000–08FFFF
SA18
0010010xxx
64/32
120000–12FFFF
090000–097FFF
SA19
0010011xxx
64/32
130000–13FFFF
098000–09FFFF
SA20
0010100xxx
64/32
140000–14FFFF
0A0000–0A7FFF
SA21
0010101xxx
64/32
150000–15FFFF
0A8000–0AFFFF
SA22
0010110xxx
64/32
160000–16FFFF
0B0000–0B7FFF
SA23
0010111xxx
64/32
170000–17FFFF
0B8000–0BFFFF
SA24
0011000xxx
64/32
180000–18FFFF
0C0000–0C7FFF
SA25
0011001xxx
64/32
190000–19FFFF
0C8000–0CFFFF
SA26
0011010xxx
64/32
1A0000–1AFFFF
0D0000–0D7FFF
SA27
0011011xxx
64/32
1B0000–1BFFFF
0D8000–0DFFFF
SA28
0011100xxx
64/32
1C0000–1CFFFF
0E0000–0E7FFF
SA29
0011101xxx
64/32
1D0000–1DFFFF
0E8000–0EFFFF
SA30
0011110xxx
64/32
1E0000–1EFFFF
0F0000–0F7FFF
SA31
0011111xxx
64/32
1F0000–1FFFFF
0F8000–0FFFFF
SA32
0100000xxx
64/32
200000–20FFFF
100000–107FFF
SA33
0100001xxx
64/32
210000–21FFFF
108000–10FFFF
SA34
0100010xxx
64/32
220000–22FFFF
110000–117FFF
SA35
0100011xxx
64/32
230000–23FFFF
118000–11FFFF
SA36
0100100xxx
64/32
240000–24FFFF
120000–127FFF
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
10
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
PPB 10
PPB 11
PPB 12
PPB 13
PPB 14
PPB 15
PPB 16
PPB 17
PPB 18
PPB 19
EN29GL064
SA37
0100101xxx
64/32
250000–25FFFF
128000–12FFFF
SA38
0100110xxx
64/32
260000–26FFFF
130000–137FFF
SA39
0100111xxx
64/32
270000–27FFFF
138000–13FFFF
SA40
0101000xxx
64/32
280000–28FFFF
140000–147FFF
SA41
0101001xxx
64/32
290000–29FFFF
148000–14FFFF
SA42
0101010xxx
64/32
2A0000–2AFFFF
150000–157FFF
SA43
0101011xxx
64/32
2B0000–2BFFFF
158000–15FFFF
SA44
0101100xxx
64/32
2C0000–2CFFFF
160000–167FFF
SA45
0101101xxx
64/32
2D0000–2DFFFF
168000–16FFFF
SA46
0101110xxx
64/32
2E0000–2EFFFF
170000–177FFF
SA47
0101111xxx
64/32
2F0000–2FFFFF
178000–17FFFF
SA48
0110000xxx
64/32
300000–30FFFF
180000–187FFF
SA49
0110001xxx
64/32
310000–31FFFF
188000–18FFFF
SA50
0110010xxx
64/32
320000–32FFFF
190000–197FFF
SA51
0110011xxx
64/32
330000–33FFFF
198000–19FFFF
SA52
0110100xxx
64/32
340000–34FFFF
1A0000–1A7FFF
SA53
0110101xxx
64/32
350000–35FFFF
1A8000–1AFFFF
SA54
0110110xxx
64/32
360000–36FFFF
1B0000–1B7FFF
SA55
0110111xxx
64/32
370000–37FFFF
1B8000–1BFFFF
SA56
0111000xxx
64/32
380000–38FFFF
1C0000–1C7FFF
SA57
0111001xxx
64/32
390000–39FFFF
1C8000–1CFFFF
SA58
0111010xxx
64/32
3A0000–3AFFFF
1D0000–1D7FFF
SA59
0111011xxx
64/32
3B0000–3BFFFF
1D8000–1DFFFF
SA60
0111100xxx
64/32
3C0000–3CFFFF
1E0000–1E7FFF
SA61
0111101xxx
64/32
3D0000–3DFFFF
1E8000–1EFFFF
SA62
0111110xxx
64/32
3E0000–3EFFFF
1F0000–1F7FFF
SA63
0111111xxx
64/32
3F0000–3FFFFF
1F8000–1FFFFF
SA64
1000000xxx
64/32
400000–40FFFF
200000–207FFF
SA65
1000001xxx
64/32
410000–41FFFF
208000–20FFFF
SA66
1000010xxx
64/32
420000–42FFFF
210000–217FFF
SA67
1000011xxx
64/32
430000–43FFFF
218000–21FFFF
SA68
1000100xxx
64/32
440000–44FFFF
220000–227FFF
SA69
1000101xxx
64/32
450000–45FFFF
228000–22FFFF
SA70
1000110xxx
64/32
460000–46FFFF
230000–237FFF
SA71
1000111xxx
64/32
470000–47FFFF
238000–23FFFF
SA72
1001000xxx
64/32
480000–48FFFF
240000–247FFF
SA73
1001001xxx
64/32
490000–49FFFF
248000–24FFFF
SA74
1001010xxx
64/32
4A0000–4AFFFF
250000–257FFF
SA75
1001011xxx
64/32
4B0000–4BFFFF
258000–25FFFF
SA76
1001100xxx
64/32
4C0000–4CFFFF
260000–267FFF
SA77
1001101xxx
64/32
4D0000–4DFFFF
268000–26FFFF
SA78
1001110xxx
64/32
4E0000–4EFFFF
270000–277FFF
SA79
1001111xxx
64/32
4F0000–4FFFFF
278000–27FFFF
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
11
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
PPB 20
PPB 21
PPB 22
PPB 23
PPB 24
PPB 25
PPB 26
PPB 27
PPB 28
PPB 29
PPB 30
EN29GL064
SA80
1010000xxx
64/32
500000–50FFFF
280000–287FFF
SA81
1010001xxx
64/32
510000–51FFFF
288000–28FFFF
SA82
1010010xxx
64/32
520000–52FFFF
290000–297FFF
SA83
1010011xxx
64/32
530000–53FFFF
298000–29FFFF
SA84
1010100xxx
64/32
540000–54FFFF
2A0000–2A7FFF
SA85
1010101xxx
64/32
550000–55FFFF
2A8000–2AFFFF
SA86
1010110xxx
64/32
560000–56FFFF
2B0000–2B7FFF
SA87
1010111xxx
64/32
570000–57FFFF
2B8000–2BFFFF
SA88
1011000xxx
64/32
580000–58FFFF
2C0000–2C7FFF
SA89
1011001xxx
64/32
590000–59FFFF
2C8000–2CFFFF
SA90
1011010xxx
64/32
5A0000–5AFFFF
2D0000–2D7FFF
SA91
1011011xxx
64/32
5B0000–5BFFFF
2D8000–2DFFFF
SA92
1011100xxx
64/32
5C0000–5CFFFF
2E0000–2E7FFF
SA93
1011101xxx
64/32
5D0000–5DFFFF
2E8000–2EFFFF
SA94
1011110xxx
64/32
5E0000–5EFFFF
2F0000–2F7FFF
SA95
1011111xxx
64/32
5F0000–5FFFFF
2F8000–2FFFFF
SA96
1100000xxx
64/32
600000–60FFFF
300000–307FFF
SA97
1100001xxx
64/32
610000–61FFFF
308000–30FFFF
SA98
1100010xxx
64/32
620000–62FFFF
310000–317FFF
SA99
1100011xxx
64/32
630000–63FFFF
318000–31FFFF
SA100
1100100xxx
64/32
640000–64FFFF
320000–327FFF
SA101
1100101xxx
64/32
650000–65FFFF
328000–32FFFF
SA102
1100110xxx
64/32
660000–66FFFF
330000–337FFF
SA103
1100111xxx
64/32
670000–67FFFF
338000–33FFFF
SA104
1101000xxx
64/32
680000–68FFFF
340000–347FFF
SA105
1101001xxx
64/32
690000–69FFFF
348000–34FFFF
SA106
1101010xxx
64/32
6A0000–6AFFFF
350000–357FFF
SA107
1101011xxx
64/32
6B0000–6BFFFF
358000–35FFFF
SA108
1101100xxx
64/32
6C0000–6CFFFF
360000–367FFF
SA109
1101101xxx
64/32
6D0000–6DFFFF
368000–36FFFF
SA110
1101110xxx
64/32
6E0000–6EFFFF
370000–377FFF
SA111
1101111xxx
64/32
6F0000–6FFFFF
378000–37FFFF
SA112
1110000xxx
64/32
700000–70FFFF
380000–387FFF
SA113
1110001xxx
64/32
710000–71FFFF
388000–38FFFF
SA114
1110010xxx
64/32
720000–72FFFF
390000–397FFF
SA115
1110011xxx
64/32
730000–73FFFF
398000–39FFFF
SA116
1110100xxx
64/32
740000–74FFFF
3A0000–3A7FFF
SA117
1110101xxx
64/32
750000–75FFFF
3A8000–3AFFFF
SA118
1110110xxx
64/32
760000–76FFFF
3B0000–3B7FFF
SA119
1110111xxx
64/32
770000–77FFFF
3B8000–3BFFFF
SA120
1111000xxx
64/32
780000–78FFFF
3C0000–3C7FFF
SA121
1111001xxx
64/32
790000–79FFFF
3C8000–3CFFFF
SA122
1111010xxx
64/32
7A0000–7AFFFF
3D0000–3D7FFF
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
12
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
SA123
1111011xxx
64/32
7B0000–7BFFFF
3D8000–3DFFFF
PPB 31
SA124
1111100xxx
64/32
7C0000–7CFFFF
3E0000–3E7FFF
PPB 32
SA125
1111101xxx
64/32
7D0000–7DFFFF
3E8000–3EFFFF
PPB 33
SA126
1111110xxx
64/32
7E0000–7EFFFF
3F0000–3F7FFF
PPB 34
SA127
1111111000
8/4
7F0000–7F1FFF
3F8000–3F8FFF
PPB 35
SA128
1111111001
8/4
7F2000–7F3FFF
3F9000–3F9FFF
PPB 36
SA129
1111111010
8/4
7F4000–7F5FFF
3FA000–3FAFFF
PPB 37
SA130
1111111011
8/4
7F6000–7F7FFF
3FB000–3FBFFF
PPB 38
SA131
1111111100
8/4
7F8000–7F9FFF
3FC000–3FCFFF
PPB 39
SA132
1111111101
8/4
7FA000–7FBFFF
3FD000–3FDFFF
PPB 40
SA133
1111111110
8/4
7FC000–7FDFFF
3FE000–3FEFFF
PPB 41
SA134
1111111111
8/4
7FE000–7FFFFF
3FF000–3FFFFF
Table 3C. Bottom Boot Sector / Persistent Protection Sector Group Address
Tables (EN29GL064B)
PPB
Group
Sector
A21 – A12
Sector Size
(Kbytes / Kwords)
Address Range (h)
Byte mode (x8)
Address Range (h)
Word Mode (x16)
PPB 0
SA0
0000000000
8/4
000000–001FFF
000000–000FFF
PPB 1
SA1
0000000001
8/4
002000–003FFF
001000–001FFF
PPB 2
SA2
0000000010
8/4
004000–005FFF
002000–002FFF
PPB 3
SA3
0000000011
8/4
006000–007FFF
003000–003FFF
PPB 4
SA4
0000000100
8/4
008000–009FFF
004000–004FFF
PPB 5
SA5
0000000101
8/4
00A000–00BFFF
005000–005FFF
PPB 6
SA6
0000000110
8/4
00C000–00DFFF
006000–006FFF
PPB 7
SA7
0000000111
8/4
00E000–00FFFF
007000–007FFF
PPB 8
SA8
0000001xxx
64/32
010000–01FFFF
008000–00FFFF
PPB 9
SA9
0000010xxx
64/32
020000–02FFFF
010000–017FFF
PPB 10
SA10
0000011xxx
64/32
030000–03FFFF
018000–01FFFF
SA11
0000100xxx
64/32
040000–04FFFF
020000–027FFF
SA12
0000101xxx
64/32
050000–05FFFF
028000–02FFFF
SA13
0000110xxx
64/32
060000–06FFFF
030000–037FFF
SA14
0000111xxx
64/32
070000–07FFFF
038000–03FFFF
SA15
0001000xxx
64/32
080000–08FFFF
040000–047FFF
SA16
0001001xxx
64/32
090000–09FFFF
048000–04FFFF
SA17
0001010xxx
64/32
0A0000–0AFFFF
050000–057FFF
SA18
0001011xxx
64/32
0B0000–0BFFFF
058000–05FFFF
SA19
0001100xxx
64/32
0C0000–0CFFFF
060000–067FFF
SA20
0001101xxx
64/32
0D0000–0DFFFF
068000–06FFFF
SA21
0001110xxx
64/32
0E0000–0EFFFF
070000–077FFF
SA22
0001111xxx
64/32
0F0000–0FFFFF
078000–07FFFF
SA23
0010000xxx
64/32
100000–10FFFF
080000–087FFF
SA24
0010001xxx
64/32
110000–11FFFF
088000–08FFFF
SA25
0010010xxx
64/32
120000–12FFFF
090000–097FFF
SA26
0010011xxx
64/32
130000–13FFFF
098000–09FFFF
PPB 11
PPB 12
PPB 13
PPB 14
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
13
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
PPB 15
PPB 16
PPB 17
PPB 18
PPB 19
PPB 20
PPB 21
PPB 22
PPB 23
PPB 24
PPB 25
EN29GL064
SA27
0010100xxx
64/32
140000–14FFFF
0A0000–0A7FFF
SA28
0010101xxx
64/32
150000–15FFFF
0A8000–0AFFFF
SA29
0010110xxx
64/32
160000–16FFFF
0B0000–0B7FFF
SA30
0010111xxx
64/32
170000–17FFFF
0B8000–0BFFFF
SA31
0011000xxx
64/32
180000–18FFFF
0C0000–0C7FFF
SA32
0011001xxx
64/32
190000–19FFFF
0C8000–0CFFFF
SA33
0011010xxx
64/32
1A0000–1AFFFF
0D0000–0D7FFF
SA34
0011011xxx
64/32
1B0000–1BFFFF
0D8000–0DFFFF
SA35
0011100xxx
64/32
1C0000–1CFFFF
0E0000–0E7FFF
SA36
0011101xxx
64/32
1D0000–1DFFFF
0E8000–0EFFFF
SA37
0011110xxx
64/32
1E0000–1EFFFF
0F0000–0F7FFF
SA38
0011111xxx
64/32
1F0000–1FFFFF
0F8000–0FFFFF
SA39
0100000xxx
64/32
200000–20FFFF
100000–107FFF
SA40
0100001xxx
64/32
210000–21FFFF
108000–10FFFF
SA41
0100010xxx
64/32
220000–22FFFF
110000–117FFF
SA42
0100011xxx
64/32
230000–23FFFF
118000–11FFFF
SA43
0100100xxx
64/32
240000–24FFFF
120000–127FFF
SA44
0100101xxx
64/32
250000–25FFFF
128000–12FFFF
SA45
0100110xxx
64/32
260000–26FFFF
130000–137FFF
SA46
0100111xxx
64/32
270000–27FFFF
138000–13FFFF
SA47
0101000xxx
64/32
280000–28FFFF
140000–147FFF
SA48
0101001xxx
64/32
290000–29FFFF
148000–14FFFF
SA49
0101010xxx
64/32
2A0000–2AFFFF
150000–157FFF
SA50
0101011xxx
64/32
2B0000–2BFFFF
158000–15FFFF
SA51
0101100xxx
64/32
2C0000–2CFFFF
160000–167FFF
SA52
0101101xxx
64/32
2D0000–2DFFFF
168000–16FFFF
SA53
0101110xxx
64/32
2E0000–2EFFFF
170000–177FFF
SA54
0101111xxx
64/32
2F0000–2FFFFF
178000–17FFFF
SA55
0110000xxx
64/32
300000–30FFFF
180000–187FFF
SA56
0110001xxx
64/32
310000–31FFFF
188000–18FFFF
SA57
0110010xxx
64/32
320000–32FFFF
190000–197FFF
SA58
0110011xxx
64/32
330000–33FFFF
198000–19FFFF
SA59
0110100xxx
64/32
340000–34FFFF
1A0000–1A7FFF
SA60
0110101xxx
64/32
350000–35FFFF
1A8000–1AFFFF
SA61
0110110xxx
64/32
360000–36FFFF
1B0000–1B7FFF
SA62
0110111xxx
64/32
370000–37FFFF
1B8000–1BFFFF
SA63
0111000xxx
64/32
380000–38FFFF
1C0000–1C7FFF
SA64
0111001xxx
64/32
390000–39FFFF
1C8000–1CFFFF
SA65
0111010xxx
64/32
3A0000–3AFFFF
1D0000–1D7FFF
SA66
0111011xxx
64/32
3B0000–3BFFFF
1D8000–1DFFFF
SA67
0111100xxx
64/32
3C0000–3CFFFF
1E0000–1E7FFF
SA68
0111101xxx
64/32
3D0000–3DFFFF
1E8000–1EFFFF
SA69
0111110xxx
64/32
3E0000–3EFFFF
1F0000–1F7FFF
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
14
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
PPB 26
PPB 27
PPB 28
PPB 29
PPB 30
PPB 31
PPB 32
PPB 33
PPB 34
PPB 35
PPB 36
EN29GL064
SA70
0111111xxx
64/32
3F0000–3FFFFF
1F8000–1FFFFF
SA71
1000000xxx
64/32
400000–40FFFF
200000–207FFF
SA72
1000001xxx
64/32
410000–41FFFF
208000–20FFFF
SA73
1000010xxx
64/32
420000–42FFFF
210000–217FFF
SA74
1000011xxx
64/32
430000–43FFFF
218000–21FFFF
SA75
1000100xxx
64/32
440000–44FFFF
220000–227FFF
SA76
1000101xxx
64/32
450000–45FFFF
228000–22FFFF
SA77
1000110xxx
64/32
460000–46FFFF
230000–237FFF
SA78
1000111xxx
64/32
470000–47FFFF
238000–23FFFF
SA79
1001000xxx
64/32
480000–48FFFF
240000–247FFF
SA80
1001001xxx
64/32
490000–49FFFF
248000–24FFFF
SA81
1001010xxx
64/32
4A0000–4AFFFF
250000–257FFF
SA82
1001011xxx
64/32
4B0000–4BFFFF
258000–25FFFF
SA83
1001100xxx
64/32
4C0000–4CFFFF
260000–267FFF
SA84
1001101xxx
64/32
4D0000–4DFFFF
268000–26FFFF
SA85
1001110xxx
64/32
4E0000–4EFFFF
270000–277FFF
SA86
1001111xxx
64/32
4F0000–4FFFFF
278000–27FFFF
SA87
1010000xxx
64/32
500000–50FFFF
280000–287FFF
SA88
1010001xxx
64/32
510000–51FFFF
288000–28FFFF
SA89
1010010xxx
64/32
520000–52FFFF
290000–297FFF
SA90
1010011xxx
64/32
530000–53FFFF
298000–29FFFF
SA91
1010100xxx
64/32
540000–54FFFF
2A0000–2A7FFF
SA92
1010101xxx
64/32
550000–55FFFF
2A8000–2AFFFF
SA93
1010110xxx
64/32
560000–56FFFF
2B0000–2B7FFF
SA94
1010111xxx
64/32
570000–57FFFF
2B8000–2BFFFF
SA95
1011000xxx
64/32
580000–58FFFF
2C0000–2C7FFF
SA96
1011001xxx
64/32
590000–59FFFF
2C8000–2CFFFF
SA97
1011010xxx
64/32
5A0000–5AFFFF
2D0000–2D7FFF
SA98
1011011xxx
64/32
5B0000–5BFFFF
2D8000–2DFFFF
SA99
1011100xxx
64/32
5C0000–5CFFFF
2E0000–2E7FFF
SA100
1011101xxx
64/32
5D0000–5DFFFF
2E8000–2EFFFF
SA101
1011110xxx
64/32
5E0000–5EFFFF
2F0000–2F7FFF
SA102
1011111xxx
64/32
5F0000–5FFFFF
2F8000–2FFFFF
SA103
1100000xxx
64/32
600000–60FFFF
300000–307FFF
SA104
1100001xxx
64/32
610000–61FFFF
308000–30FFFF
SA105
1100010xxx
64/32
620000–62FFFF
310000–317FFF
SA106
1100011xxx
64/32
630000–63FFFF
318000–31FFFF
SA107
1100100xxx
64/32
640000–64FFFF
320000–327FFF
SA108
1100101xxx
64/32
650000–65FFFF
328000–32FFFF
SA109
1100110xxx
64/32
660000–66FFFF
330000–337FFF
SA110
1100111xxx
64/32
670000–67FFFF
338000–33FFFF
SA111
1101000xxx
64/32
680000–68FFFF
340000–347FFF
SA112
1101001xxx
64/32
690000–69FFFF
348000–34FFFF
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
15
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
PPB 37
PPB 38
PPB 39
PPB 40
PPB 41
EN29GL064
SA113
1101010xxx
64/32
6A0000–6AFFFF
350000–357FFF
SA114
1101011xxx
64/32
6B0000–6BFFFF
358000–35FFFF
SA115
1101100xxx
64/32
6C0000–6CFFFF
360000–367FFF
SA116
1101101xxx
64/32
6D0000–6DFFFF
368000–36FFFF
SA117
1101110xxx
64/32
6E0000–6EFFFF
370000–377FFF
SA118
1101111xxx
64/32
6F0000–6FFFFF
378000–37FFFF
SA119
1110000xxx
64/32
700000–70FFFF
380000–387FFF
SA120
1110001xxx
64/32
710000–71FFFF
388000–38FFFF
SA121
1110010xxx
64/32
720000–72FFFF
390000–397FFF
SA122
1110011xxx
64/32
730000–73FFFF
398000–39FFFF
SA123
1110100xxx
64/32
740000–74FFFF
3A0000–3A7FFF
SA124
1110101xxx
64/32
750000–75FFFF
3A8000–3AFFFF
SA125
1110110xxx
64/32
760000–76FFFF
3B0000–3B7FFF
SA126
1110111xxx
64/32
770000–77FFFF
3B8000–3BFFFF
SA127
1111000xxx
64/32
780000–78FFFF
3C0000–3C7FFF
SA128
1111001xxx
64/32
790000–79FFFF
3C8000–3CFFFF
SA129
1111010xxx
64/32
7A0000–7AFFFF
3D0000–3D7FFF
SA130
1111011xxx
64/32
7B0000–7BFFFF
3D8000–3DFFFF
SA131
1111100xxx
64/32
7C0000–7CFFFF
3E0000–3E7FFF
SA132
1111101xxx
64/32
7D0000–7DFFFF
3E8000–3EFFFF
SA133
1111110xxx
64/32
7E0000–7EFFFF
3F0000–3F7FFF
SA134
1111111xxx
64/32
7F0000–7FFFFF
3F8000–3FFFFF
Table 4. Device OPERATING MODES
64M FLASH USER MODE TABLE
Operation
Read
Write
CE#
L
L
OE#
L
H
WE#
H
L
RESET#
H
H
WP#/ACC
L/H
(Note 1)
A0A21
A IN
A IN
Accelerated
Program
L
H
L
H
V HH
A IN
B
B
B
B
B
B
B
DQ0DQ7
D OUT
D IN
D IN
B
B
B
B
B
B
DQ8-DQ15
BYTE#
BYTE#
= V IL
= V IH
D OUT
DQ8DQ14=H
D IN
igh-Z,
DQ15 =
D IN
A-1
B
B
B
B
B
B
B
B
B
B
CMOS Standby
V cc
X
X
Vcc±0.3V
H
X
High-Z
High-Z
High-Z
Output Disable
Hardware Reset
L
X
H
X
H
X
H
L
L/H
L/H
X
X
High-Z
High-Z
High-Z
High-Z
High-Z
High-Z
B
B
±0.3V
Notes:
1. Addresses are A21:A0 in word mode; A21:A-1 in byte mode.
2. If WP# = VIL, on the outermost sector remains protected. If WP# = VIH, the outermost sector is unprotected. WP# has an
internal pull-up; when unconnected, WP# is at VIH. All sectors are unprotected when shipped from the factory (The Secured
Silicon Sector can be factory protected depending on version ordered.)
3. DIN or DOUT as required by command sequence, data polling, or sector protect algorithm.
Legend
L = Logic Low = VIL, H = Logic High = VIH, VHH = 8.5–9.5V, X = Don’t Care, AIN = Address In, DIN = Data In, DOUT = Data
Out
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
16
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
TABLE 5. Autoselect Codes (Using High Voltage, VID)
64M FLASH MANUFACTURER/DEVICE ID TABLE
Description
Manufacturer
ID: Eon
CE#
L
OE#
L
WE#
H
A21
to
A16
A14
to
A10
A9
X
X
VID
A8
H
L
A7
X
A6
L
A5
to
A4
A3
to
A2
A1
X
X
L
L
Device ID
Cycle 1
Cycle 2
L
L
H
X
X
VID
X
X
L
X
Cycle 3
Sector Group
Protection
Verification
Secured Silicon
Sector Indicator
Bit(DQ7),WP#
protects highest
address sector
Secured Silicon
Sector Indicator
Bit(DQ7),WP#
protects lowest
address sector
A0
DQ8 to DQ15
DQ7 to DQ0
Model
BYTE
#=VIH
BYTE
#=VIL
L
X
X
L
H
22
X
7EH
7Eh
H
H
L
22
X
0Ch
10h
H
H
H
22
X
01h
00h(B)
01h(T)
H/L
T/B
1Ch
7Fh
L
L
H
SA
X
VID
X
X
L
X
L
H
L
X
X
01h(protected)
00h(unprotected)
L
L
H
X
X
VID
X
X
L
X
L
H
H
X
X
9Ah(factory
locked),
1Ah(not factory
locked)
L
L
H
X
X
VID
X
X
L
X
L
H
L
X
X
8Ah(factory
locked),
0Ah(not factory
locked)
Note:
1. A8=H is recommended for Manufacturing ID check. If a manufacturing ID is read with A8=L, the chip will output a configuration
code 7Fh
2. A9 = VID is for HV A9 Autoselect mode only. A9 must be ≤ Vcc (CMOS logic level) for Command Autoselect Mode.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
17
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
USER MODE DEFINITIONS
Word / Byte Configuration
The BYTE# pin controls whether the device data I/O pins operate in the byte or word configuration. If the
BYTE# pin is set at logic ‘1’, the device is in word configuration, DQ0-DQ15 are active and controlled by
CE# and OE#.
If the BYTE# pin is set at logic ‘0’, the device is in byte configuration, and only data I/O pins DQ0-DQ7
are active and controlled by CE# and OE#. The data I/O pins DQ8-DQ14 are tri-stated, and the DQ15
pin is used as an input for the LSB (A-1) address function.
VIO Control
The VIO allows the host system to set the voltage levels that the device generates and tolerates on all
inputs and outputs (address, control, and DQ signals). VIO range is 1.65 to VCC. For example, a VIO of
1.65-3.6 volts allows for I/O at the 1.65 or 3.6 volt levels, driving and receiving signals to and from other
1.65 or 3.6 V devices on the same data bus. Only 48-pin TSOP package does not offer VIO function.
Read
All memories require access time to output array data. In a read operation, data is read from one
memory location at a time. Addresses are presented to the device in random order, and the propagation
delay through the device causes the data on its outputs to arrive with the address on its inputs.
The device defaults to reading array data after device power-up or hardware reset. To read data from
the memory array, the system must first assert a valid address on A21-A0, while driving OE# and CE#
to VIL. WE# must remain at VIH. All addresses are latched on the falling edge of CE#. Data will appear
on DQ15-DQ0 after address access time (tACC), which is equal to the delay from stable addresses to
valid output data.The OE# signal must be driven to VIL. Data is output on DQ15-DQ0 pins after the
access time (tOE) has elapsed from the falling edge of OE#, assuming the tACC access time has been
meet.
Page Read Mode
The device is capable of fast page mode read and is compatible with the page mode Mask ROM read
operation. This mode provides faster read access speed for random locations within a page. The page
size of the device is 8 words/16 bytes. The appropriate page is selected by the higher address bits A21A3. Address bits A2-A0 in word mode (A2 to A-1 in byte mode) determine the specific word within a
page. The microprocessor supplies the specific word location.
The random or initial page access is equal to tACC or tCE and subsequent page read accesses (as long
as the locations specified by the microprocessor falls within that page) is equivalent to tPACC. When
CE# is deasserted and reasserted for a subsequent access, the access time is tACC or tCE. Fast page
mode accesses are obtained by keeping the “read-page addresses” constant and changing the “intraread page” addresses.
Autoselect
The Autoselect mode provides manufacturer ID, Device identification, and sector protection information,
through identifier codes output from the internal register (separate from the memory array) on DQ7-DQ0.
This mode is primarily intended for programming equipment to automatically match a device to be
programmed with its corresponding programming algorithm. The Autoselect codes can also be
accessed in-system.
There are two methods to access autoselect codes. One uses the autoselect command, the other
applies VID on address pin A9.
When using programming equipment, the autoselect mode requires VID (8.5 V to 9.5 V) on address pin
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
18
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
A9.
Address pins must be as shown in Table 4.
• To access Autoselect mode without using high voltage on A9, the host system must issue the
Autoselect command.
• The Autoselect command sequence may be written to an address within a sector that is either in the
read or erase-suspend-read mode.
• The Autoselect command may not be written while the device is actively programming or erasing.
• The system must write the reset command to return to the read mode (or erase-suspend-read mode
if the sector was previously in Erase Suspend).
• It is recommended that A9 apply VID after power-up sequence is completed. In addition, it is
recommended that A9 apply from VID to VIH/VIL before power-down the VCC / VIO.
• When verifying sector protection, the sector address must appear on the appropriate highest order
address bits. The remaining address bits are don't care. When all necessary bits have been set as
required, the programming equipment may then read the corresponding identifier code on DQ15DQ0. The Autoselect codes can also be accessed in-system through the command register.
Program/Erase Operations
These devices are capable of several modes of programming and or erase operations which are
described in detail in the following sections.
During a write operation, the system must drive CE# and WE# to VIL and OE# to VIH when providing
address, command, and data. Addresses are latched on the last falling edge of WE# or CE#, while data
is latched on the 1st rising edge of WE# or CE#.
The Accelerated Program mode allows the host system to send program commands to the Flash device
without first writing unlock cycles within the command sequence.
Note the following:
• When the Embedded Program algorithm is complete, the device returns to the read mode.
• The system can determine the status of the program operation by reading the DQ status bits. Refer
to the Write Operation Status on page 20 for information on these status bits.
• An “0” cannot be programmed back to a “1.” A succeeding read shows that the data is still “0.”
• Only erase operations can convert a “0” to a “1.”
• Any commands written to the device during the Embedded Program/Erase are ignored except the
Suspend commands.
• Secured Silicon Sector, Autoselect, and CFI functions are unavailable when a program operation is
in progress.
• A hardware reset and/or power removal immediately terminates the Program/Erase operation and
the Program/Erase command sequence should be reinitiated once the device has returned to the
read mode to ensure data integrity.
• Programming is allowed in any sequence and across sector boundaries for single word programming
operation.
• Programming to the same word address multiple times without intervening erases is permitted.
Single Word Programming
Single word programming mode is one method of programming the Flash. In this mode, four Flash
command write cycles are used to program an individual Flash address. The data for this programming
operation could be 8 or 16-bits wide.
While the single word programming method is supported by most devices, in general Single Word
Programming is not recommended for devices that support Write Buffer Programming.
When the Embedded Program algorithm is complete, the device then returns to the read mode and
addresses are no longer latched. The system can determine the status of the program operation by
reading the DQ status bits.
• During programming, any command (except the Suspend Program command) is ignored.
• The Secured Silicon Sector, Autoselect, and CFI functions are unavailable when a program
operation is in progress.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
19
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
• A hardware reset immediately terminates the program operation. The program command sequence
should be reinitiated once the device has returned to the read mode, to ensure data integrity.
• Programming to the same address multiple times continuously (for example, “walking” a bit within a
word) is permitted.
Figure 5. Single Word Program
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
20
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Write Buffer Programming
Write Buffer Programming allows the system to write a maximum of 16 words in one programming
operation. This results in a faster effective word programming time than the standard “word”
programming algorithms. The Write Buffer Programming command sequence is initiated by first writing
two unlock cycles. This is followed by a third write cycle containing the Write Buffer Load command
written at the Sector Address in which programming occurs. At this point, the system writes the number
of “word locations minus 1” that are loaded into the page buffer at the Sector Address in which
programming occurs. This tells the device how many write buffer addresses are loaded with data and
therefore when to expect the “Program Buffer to Flash” confirm command. The number of locations to
program cannot exceed the size of the write buffer or the operation aborts. (Number loaded = the
number of locations to program minus 1. For example, if the system programs 6 address locations, then
05h should be written to the device.)
The system then writes the starting address/data combination. This starting address is the first
address/data pair to be programmed, and selects the “write-buffer-page” address. All subsequent
address/data pairs must fall within the elected-write-buffer-page.
The “write-buffer-page” is selected by using the addresses A21–A5.
The “write-buffer-page” addresses must be the same for all address/data pairs loaded into the write
buffer. (This means Write Buffer Programming cannot be performed across multiple “write-bufferpages.” This also means that Write Buffer Programming cannot be performed across multiple sectors. If
the system attempts to load programming data outside of the selected “write-buffer-page”, the operation
ABORTs.)
After writing the Starting Address/Data pair, the system then writes the remaining address/data pairs
into the write buffer.
Note that if a Write Buffer address location is loaded multiple times, the “address/data pair” counter is
decremented for every data load operation. Also, the last data loaded at a location before the “Program
Buffer to Flash” confirm command is the data programmed into the device. It is the software's
responsibility to comprehend ramifications of loading a write-buffer location more than once. The
counter decrements for each data load operation, NOT for each unique write-buffer-address location.
Once the specified number of write buffer locations have been loaded, the system must then write the
“Program Buffer to Flash” command at the Sector Address. Any other address/data write combinations
abort the Write Buffer Programming operation. The Write Operation Status bits should be used while
monitoring the last address location loaded into the write buffer. This eliminates the need to store an
address in memory because the system can load the last address location, issue the program confirm
command at the last loaded address location, and then check the write operation status at that same
address. DQ7, DQ6, DQ5, DQ2, and DQ1 should be monitored to determine the device status during
Write Buffer Programming.
The write-buffer “embedded” programming operation can be suspended using the standard
suspend/resume commands. Upon successful completion of the Write Buffer Programming operation,
the device returns to READ mode.
The Write Buffer Programming Sequence is ABORTED under any of the following conditions:
• Load a value that is greater than the page buffer size during the “Number of Locations to Program”
step.
• Write to an address in a sector different than the one specified during the Write-Buffer-Load
command.
• Write an Address/Data pair to a different write-buffer-page than the one selected by the “Starting
Address” during the “write buffer data loading” stage of the operation.
• Writing anything other than the Program to Buffer Flash Command after the specified number of
“data load” cycles.
The ABORT condition is indicated by DQ1 = 1, DQ7 = DATA# (for the “last address location loaded”),
DQ6 = TOGGLE, DQ5 = 0. This indicates that the Write Buffer Programming Operation was ABORTED.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
21
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
A “Write-to- Buffer-Abort reset” command sequence is required when using the write buffer
Programming features in Unlock Bypass mode. Note that the Secured Silicon sector, autoselect, and
CFI functions are unavailable when a program operation is in progress.
Write buffer programming is allowed in any sequence of memory (or address) locations. These flash
devices are capable of handling multiple write buffer programming operations on the same write buffer
address range without intervening erases.
Use of the write buffer is strongly recommended for programming when multiple words are to be
programmed.
Figure 6. Write Buffer Programming Operation
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
22
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Sector Erase
Sector erase is a six bus cycle operation. The sector erase command sequence is initiated by writing
two un-lock cycles, followed by a set-up command. Two additional unlock write cycles are then followed
by the address of the sector to be erased, and the sector erase command. The Command Definitions
table shows the address and data requirements for the sector erase command sequence.
Once the sector erase operation has begun, only the Sector Erase Suspend command is valid. All other
commands are ignored. If there are several sectors to be erased, Sector Erase Command sequences
must be issued for each sector. That is, only a sector address can be specified for each Sector
Erase command. Users must issue another Sector Erase command for the next sector to be erased
after the previous one is completed.
When the Embedded Erase algorithm is completed, the device returns to reading array data and
addresses are no longer latched. The system can determine the status of the erase operation by using
DQ7, DQ6, or DQ2. Refer to “Write Operation Status” for information on these status bits. Flowchart 4
illustrates the algorithm for the erase operation. Refer to the Erase/Program Operations tables in the
“AC Characteristics” section for parameters, and to the Sector Erase Operations Timing diagram for
timing waveforms.
Figure 7. Sector Erase Operation
START
Write Erase
Command Sequence
Data Poll from
System or Toggle Bit
successfully
completed
No
Data =FFh?
Yes
Erase Done
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
23
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Chip Erase Command Sequence
Chip erase is a six-bus cycle operation as indicated by Table 14-1. These commands invoke the
Embedded Erase algorithm, which does not require the system to preprogram prior to erase. The
Embedded Erase algorithm automatically preprograms and verifies the entire memory to an all zero data
pattern prior to electrical erase. After a successful chip erase, all locations of the chip contain FFFFh.
The system is not required to provide any controls or timings during these operations.
When the Embedded Erase algorithm is complete, that sector returns to the read mode and addresses
are no longer latched. The system can determine the status of the erase operation by using DQ7 or
DQ6/DQ2. Refer to “Write Operation Status” for information on these status bits.
Any commands written during the chip erase operation are ignored. However, note that a hardware
reset immediately terminates the erase operation. If that occurs, the chip erase command sequence
should be reinitiated once that sector has returned to reading array data, to ensure the entire array is
properly erased.
Erase Suspend/Erase Resume Commands
The Erase Suspend command allows the system to interrupt a sector erase operation and then read
data from, or program data to, any sector not selected for erasure. The sector address is required when
writing this command. This command is valid only during the sector erase operation. The Sector Erase
Suspend command is ignored if written during the chip erase operation or Embedded Program algorithm.
Addresses are don’t-cares when writing the Sector Erase Suspend command.
When the Erase Suspend command is written during the sector erase operation, the device requires a
maximum of 20 µs to suspend the erase operation.
After the erase operation has been suspended, the device enters the erase-suspend-read mode. The
system can read data from or program data to any sector not selected for erasure. (The device “erase
suspends” all sectors selected for erasure.) Reading at any address within erase-suspended sectors
produces status information on DQ7-DQ0. The system can use DQ7, or DQ6, and DQ2 together, to
determine if a sector is actively erasing or is erase-suspended.
After an erase-suspended program operation is complete, the device returns to the erase-suspend-read
mode. The system can determine the status of the program operation using write operation status bits,
just as in the standard program operation.
In the erase-suspend-read mode, the system can also issue the Autoselect command sequence. Refer
to Write Buffer Programming on page 15 and the Autoselect on page 12 for details.
To resume the sector erase operation, the system must write the Erase Resume command. The
address of the erase-suspended sector is required when writing this command. Further writes of the
Resume command are ignored. Another Erase Suspend command can be written after the chip has
resumed erasing.
Program Suspend/Program Resume Commands
The Program Suspend command allows the system to interrupt an embedded programming operation
or a “Write to Buffer” programming operation so that data can read from any non-suspended sector.
When the Program Suspend command is written during a programming process, the device halts the
programming operation within 15 µs maximum (5 µs typical) and updates the status bits. Addresses are
“don't-cares” when writing the Program Suspend command.
After the programming operation has been suspended, the system can read array data from any
nonsuspended sector. The Program Suspend command may also be issued during a programming
operation while an erase is suspended. In this case, data may be read from any addresses not within a
sector in Erase Suspend or Program Suspend. If a read is needed from the Secured Silicon Sector area,
then user must use the proper command sequences to enter and exit this region.
The system may also write the Autoselect Command Sequence when the device is in Program Suspend
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
24
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
mode. The device allows reading Autoselect codes in the suspended sectors, since the codes are not
stored in the memory array. When the device exits the Autoselect mode, the device reverts to Program
Suspend mode, and is ready for another valid operation.
After the Program Resume command is written, the device reverts to programming. The system can
determine the status of the program operation using the write operation status bits, just as in the
standard program operation.
The system must write the Program Resume command (address bits are “don't care”) to exit the
Program Suspend mode and continue the programming operation. Further writes of the Program
Resume command are ignored. Another Program Suspend command can be written after the device
has resumed programming.
Accelerated Program
Accelerated single word programming and write buffer programming operations are enabled through the
WP#/ACC pin. This method is faster than the standard program command sequences.
If the system asserts VHH on this input, the device automatically enters the Accelerated Program mode
and uses the higher voltage on the input to reduce the time required for program operations. The
system can then use the Write Buffer Load command sequence provided by the Accelerated Program
mode. Note that if a “Write-to-Buffer-Abort Reset” is required while in Accelerated Program mode, the
full 3-cycle RESET command sequence must be used to reset the device. Removing VHH from the
ACC input, upon completion of the embedded program operation, returns the device to normal operation.
• Sectors must be unlocked prior to raising WP#/ACC to VHH.
• The WP#/ACC pin must not be at VHH for operations other than accelerated programming, or device
damage may result.
• It is recommended that WP#/ACC apply VHH after power-up sequence is completed. In addition, it is
recommended that WP#/ACC apply from VHH to VIH/VIL before powering down VCC/ VIO .
(check VHH VID both have or not)
Write Operation Status
The device provides several bits to determine the status of a program or erase operation. The following
subsections describe the function of DQ1, DQ2, DQ3, DQ5, DQ6, and DQ7.
DQ7: Data# Polling
The Data# Polling bit, DQ7, indicates to the host system whether an Embedded Program or Erase
algorithm is in progress or completed, or whether the device is in Erase Suspend. Data# Polling is valid
after the rising edge of the final WE# pulse in the command sequence. Note that the Data# Polling is
valid only for the last word being programmed in the write-buffer-page during Write Buffer Programming.
Reading Data# Polling status on any word other than the last word to be programmed in the write-bufferpage returns false status information.
During the Embedded Program algorithm, the device outputs on DQ7 the complement of the datum
programmed to DQ7. This DQ7 status also applies to programming during Erase Suspend. When the
Embedded Program algorithm is complete, the device outputs the datum programmed to DQ7. The
system must provide the program address to read valid status information on DQ7. If a program
address falls within a protected sector, Data# polling on DQ7 is active, then that sector returns to the
read mode.
During the Embedded Erase Algorithm, Data# polling produces a “0” on DQ7. When the Embedded
Erase algorithm is complete, or if the device enters the Erase Suspend mode, Data# Polling produces a
“1” on DQ7. The system must provide an address within any of the sectors selected for erasure to read
valid status information on DQ7.
After an erase command sequence is written, if all sectors selected for erasing are protected, Data#
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
25
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Polling on DQ7 is active for approximately 100 µs, then the device returns to the read mode. If not all
selected sectors are protected, the Embedded Erase algorithm erases the unprotected sectors, and
ignores the selected sectors that are protected. However, if the system reads DQ7 at an address within
a protected sector, the status may not be valid.
Just prior to the completion of an Embedded Program or Erase operation, DQ7 may change
asynchronously with DQ6-DQ0 while Output Enable (OE#) is asserted low. That is, the device may
change from providing status information to valid data on DQ7. Depending on when the system samples
the DQ7 output, it may read the status or valid data. Even if the device has completed the program or
erase operation and DQ7 has valid data, the data outputs on DQ6-DQ0 may be still invalid. Valid data
on DQ7-D00 appears on successive read cycles.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
26
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Figure 8. Write Operation Status Flowchart
DQ6: Toggle Bit I
Toggle Bit I on DQ6 indicates whether an Embedded Program or Erase algorithm is in progress or
complete, or whether the device has entered the Erase Suspend mode. Toggle Bit I may be read at any
address, and is valid after the rising edge of the final WE# pulse in the command sequence (prior to the
program or erase operation), and during the sector erase time-out.
During an Embedded Program or Erase algorithm operation, successive read cycles to any address that
is being programmed or erased causes DQ6 to toggle. When the operation is complete, DQ6 stops
toggling.
After an erase command sequence is written, if all sectors selected for erasing are protected, DQ6
toggles for approximately 100 s, then returns to reading array data. If not all selected sectors are
protected, the Embedded Erase algorithm erases the unprotected sectors, and ignores the selected
sectors that are protected.
The system can use DQ6 and DQ2 together to determine whether a sector is actively erasing or is erase
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
27
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
erase 2suspended. When the device is actively erasing (that is, the Embedded Erase algorithm is in
progress), DQ6 toggles. When the device enters the Erase Suspend mode, DQ6 stops toggling.
However, the system must also use DQ2 to determine which sectors are erasing or erase-suspended.
Alternatively, the system can use DQ7.
If a program address falls within a protected sector, DQ6 toggles for approximately 1 s after the
program command sequence is written, then returns to reading array data. DQ6 also toggles during the
erase-suspend-program mode, and stops toggling once the Embedded Program Algorithm is complete.
Toggle Bit I on DQ6 requires either OE# or CE# to be de-asserted and reasserted to show the change in
state.
DQ2: Toggle Bit II
The “Toggle Bit II” on DQ2, when used with DQ6, indicates whether a particular sector is actively
erasing (that is, the Embedded Erase algorithm is in progress), or whether that sector is erasesuspended. Toggle Bit II is valid after the rising edge of the final WE# pulse in the command sequence.
DQ2 toggles when the system reads at addresses within those sectors that have been selected for
erasure. But DQ2 cannot distinguish whether the sector is actively erasing or is erase-suspended. DQ6,
by comparison, indicates whether the device is actively erasing, or is in Erase Suspend, but cannot
distinguish which sectors are selected for erasure. Thus, both status bits are required for sector and
mode information.
Reading Toggle Bits DQ6/DQ2
Whenever the system initially begins reading toggle bit status, it must read DQ7–DQ0 at least twice in a
row to determine whether a toggle bit is toggling. Typically, the system would note and store the value of
the toggle bit after the first read. After the second read, the system would compare the new value of the
toggle bit with the first. If the toggle bit is not toggling, the device has completed the program or erases
operation. The system can read array data on DQ7–DQ0 on the following read cycle. However, if after
the initial two read cycles, the system determines that the toggle bit is still toggling, the system also
should note whether the value of DQ5 is high. If it is, the system should then determine again whether
the toggle bit is toggling, since the toggle bit may have stopped toggling just as DQ5 went high. If the
toggle bit is no longer toggling, the device has successfully completed the program or erases operation.
If it is still toggling, the device did not complete the operation successfully, and the system must write
the reset command to return to reading array data. The remaining scenario is that the system initially
determines that the toggle bit is toggling and DQ5 has not gone high. The system may continue to
monitor the toggle bit and DQ5 through successive read cycles, determining the status as described in
the previous paragraph. Alternatively, it may choose to perform other system tasks. In this case, the
system must start at the beginning of the algorithm when it returns to determine the status of the
operation.
Note
When verifying the status of a write operation (embedded program/erase) of a memory sector, DQ6 and
DQ2 toggle between high and low states in a series of consecutive and contiguous status read cycles. In
order for this toggling behavior to be properly observed, the consecutive status bit reads must not be
interleaved with read accesses to other memory sectors. If it is not possible to temporarily prevent reads
to other memory sectors, then it is recommended to use the DQ7 status bit as the alternative method of
determining the active or inactive status of the write operation.
DQ5: Exceeded Timing Limits
DQ5 indicates whether the program or erase time has exceeded a specified internal pulse count limit.
Under these conditions DQ5 produces a “1,” indicating that the program or erase cycle was not
successfully completed. The device does not output a 1 on DQ5 if the system tries to program a 1 to a
location that was previously programmed to 0. Only an erase operation can change a 0 back to a 1.
Under this condition, the device ignores the bit that was incorrectly instructed to be programmed from a
0 to a 1, while any other bits that were correctly requested to be changed from 1 to 0 are programmed.
Attempting to program a 0 to a 1 is masked during the programming operation. Under valid DQ5
conditions, the system must write the reset command to return to the read mode (or to the erasesuspend-read mode if a sector was previously in the erase-suspend-program mode).
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
28
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
DQ3: Sector Erase Timeout State Indicator
After writing a sector erase command sequence, the output on DQ3 can be checked to determine
whether or not an erase operation has begun. (The sector erase timer does not apply to the chip erase
command.) When sector erase starts, DQ3 switches from “0” to “1”. This device does not support
multiple sector erase (continuous sector erase) command sequences so it is not very meaningful since
it immediately shows as a “1” after the first 30h command. Future devices may support this feature.
DQ1: Write to Buffer Abort
DQ1 indicates whether a Write to Buffer operation was aborted. Under these conditions DQ1 produces
a “1”. The system must issue the “Write to Buffer Abort Reset” command sequence to return the device
to reading array data.
Table 6. Write Operation Status
DQ7
(note 2)
DQ6
DQ5
(note 1)
DQ3
DQ2
(note 2)
DQ1
RY/BY#
Embedded Program Algorithm
DQ7#
Toggle
0
N/A
No
Toggle
0
0
Embedded Erase Algorithm
0
Toggle
0
1
Toggle
N/A
0
Status
Standard
Mode
Program
Suspend
Mode
Erase
Suspend
Mode
Write to
Buffer
Program
Suspend
Read
Erase
Suspend
Read
Program Suspended
Sector
Non-Program
Suspended Sector
Erase Suspended
Sector
Non-Erase
Suspended Sector
Invalid (Not allowed)
1
Data
1
No
Toggle
1
0
N/A
Toggle
N/A
Data
1
0
Erase Suspend Program
(Embedded Program)
DQ7#
Toggle
0
N/A
N/A
N/A
0
Busy(note 3)
Abort(note 4)
DQ7#
DQ7#
Toggle
Toggle
0
0
N/A
N/A
N/A
N/A
0
1
0
0
Notes
1. DQ5 switches to 1 when an Embedded Program, Embedded Erase, or Write-to-Buffer operation has
exceeded the maximum timing limits.
2. DQ7 and DQ2 require a valid address when reading status information. Refer to the appropriate
subsection for further details.
3. The Data# Polling algorithm should be used to monitor the last loaded write-buffer address location.
4. DQ1 switches to 1 when the device has aborted the write-to-buffer operation
Writing Commands/Command Sequences
During a write operation, the system must drive CE# and WE# to VIL and OE# to VIH when providing an
address, command, and data. Addresses are latched on the last falling edge of WE# or CE#, while data
is latched on the 1st rising edge of WE# or CE#. An erase operation can erase one sector or the entire
device. Table 3 indicate the address space that each sector occupies. The device address space is
divided into uniform 32KW/64KB sectors. A sector address is the set of address bits required to uniquely
select a sector. ICC2 in “DC Characteristics” represents the active current specification for the write
mode. “AC Characteristics” contains timing specification tables and timing diagrams for write operations.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
29
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
RY/BY#
The RY/BY# is a dedicated, open-drain output pin that indicates whether an Embedded Algorithm is in
progress or complete. The RY/BY# status is valid after the rising edge of the final WE# pulse in the
command sequence. Since RY/BY# is an open-drain output, several RY/BY# pins can be tied together
in parallel with a pull-up resistor to VCC. This feature allows the host system to detect when data is ready
to be read by simply monitoring the RY/BY# pin, which is a dedicated output and controlled by CE# (not
OE#).
Hardware Reset
The RESET# input provides a hardware method of resetting the device to reading array data. When
RESET# is driven low for at least a period of tRP (RESET# Pulse Width), the device immediately
terminates any operation in progress, tristates all outputs, resets the configuration register, and ignores
all read/write commands for the duration of the RESET# pulse. The device also resets the internal state
machine to reading array data.
To ensure data integrity Program/Erase operations that were interrupted should be reinitiated once the
device is ready to accept another command sequence.
When RESET# is held at VSS, the device draws VCC reset current (ICC5). If RESET# is held at VIL, but
not at VSS, the standby current is greater. RESET# may be tied to the system reset circuitry which
enables the system to read the boot-up firmware from the Flash memory upon a system reset.
Software Reset
Software reset is part of the command set that also returns the device to array read mode and must be
used for the following conditions:
1. To exit Autoselect mode
2. When DQ5 goes high during write status operation that indicates program or erase cycle was not
successfully completed
3. Exit sector lock/unlock operation.
4. To return to erase-suspend-read mode if the device was previously in Erase Suspend mode.
5. After any aborted operations
The following are additional points to consider when using the reset command:
• This command resets the sectors to the read and address bits are ignored.
• Reset commands are ignored during program and erase operations.
• The reset command may be written between the cycles in a program command sequence before
programming begins (prior to the third cycle). This resets the sector to which the system was writing
to the read mode.
• If the program command sequence is written to a sector that is in the Erase Suspend mode, writing
the reset command returns that sector to the erase-suspend-read mode.
• The reset command may be written during an Autoselect command sequence.
• If a sector has entered the Autoselect mode while in the Erase Suspend mode, writing the reset
command returns that sector to the erase-suspend-read mode.
• If DQ1 goes high during a Write Buffer Programming operation, the system must write the “Write to
Buffer Abort Reset” command sequence to RESET the device to reading array data. The standard
RESET command does not work during this condition.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
30
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Advanced Sector Protection/Unprotection
The Advanced Sector Protection/Unprotection feature disables or enables programming or erase
operations in any or all sectors and can be implemented through software and/or hardware methods,
which are independent of each other. This section describes the various methods of protecting data
stored in the memory array. An overview of these methods in shown in Figure 8.
Figure 8a. Advanced Sector Protection/Unprotection for Uniform Sector
!
! '
!% '
#' #
,#&'!
0 1
!
" #$$ " 0 1 ' ! #'
'
! +
&
!#
2
" #$ $
0 1
3& !+# /#
!
&'
! " #$$
)& ' #
'
'
* #
, # +!
*
#
) !#
'
( ,, % ,
! +#
%#
'
"$ +# !$
- '
#'
!. ,#&'!
&
#,
/ &
!
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
31
% &#'
'
(
%'
(
*
+#%
!
!
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Figure 8b. Advanced Sector Protection/Unprotection for Bottom Boot Sector
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
32
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Figure 8c. Advanced Sector Protection/Unprotection for Top Boot Sector
Lock Register
The Lock Register consists of 4 bits. The Secured Silicon Sector Protection Bit is DQ0, Persistent
Protection Mode Lock Bit is DQ1, Persistent Sector Protection OTP bit is DQ3 and DYB Lock Boot Bit is
DQ4. If DQ0 is ‘0’, it means that the Customer Secured Silicon area is locked and if DQ0 is ‘1’, it means
that it is unlocked. When DQ1 is set to ‘0’, the device is used in the Persistent Protection Mode. DQ3 is
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
33
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
programmed in the EON factory. When the device is programmed to disable all PPB erase command,
DQ3 outputs a ‘0’, when the lock register bits are read. Similarly, if the device is programmed to enable
all PPB erase command, DQ3 outputs a ‘1’ when the lock register bits are read. Likewise the DQ4 bit is
also programmed in the EON Factory. DQ4 is the bit which indicates whether Volatile Sector Protection
Bit (DYB) is protected or not after boot-up. When the device is programmed to set all Volatile Sector
Protection Bit protected after power-up, DQ4 outputs a ‘0’ when the lock register bits are read. Similarly,
when the device is programmed to set all Volatile Sector Protection Bit unprotected after power-up, DQ4
outputs a ‘1’. Each of these bits in the lock register are non-volatile. DQ15- DQ5 are reserved and will be
1’s.
Table 7. Lock Register
DQ15-5
DQ4
Reserved DYB Lock Boot Bit
DQ3
PPB One Time
Programmable Bit
0 = protected all 0 = All PPB Erase
DYB after boot-up Command disabled
(default = 1)
1 = unprotected all 1 = All PPB Erase
DYB after boot-up Command enabled
DQ2
DQ1
DQ0
Reserved
Persistent
Protection Mode
Lock Bit
OTP Lock Bit
0 = protected
0 = Persistent
Lock Register
(default = 1) Protection enabled
1 = unprotect
(default = 0)
Lock Register
Notes:
After the Lock Register Bits Command Set Entry command sequence is written, reads and writes
for Sector 0 are disabled, while reads from other sectors are allowed until exiting this mode.
After selecting a sector protection method, each sector can operate in any of the following three states:
1. Constantly locked: The selected sectors are protected and can not be reprogrammed unless PPB
lock bit is cleared via hardware reset, or power cycle.
2. Dynamically locked: The selected sectors are protected and can be altered via software commands.
3. Unlocked: The sectors are unprotected and can be erased and/or programmed.
Persistent Protection Bits
The Persistent Protection Bits are unique and nonvolatile. For uniform sector device, Sector 0~3 and
124~127 have one PPB for each sectors and for Sector 4~123 have one PPB every four sectors. For
bottom boot sector device, Sector 0~123 are 1 PPB per 4 sectors and Sector 124~134 have PPB for
each boot sector. For top boot sector device, Sector 0~10 have PPB for each boot sector and Sector
11~134 are 1 PPB per 4 sectors(refer to Figure 8a, 8b, 8c and Table 3a, 3b, 3c). The PPB has the
same endurances as the Flash memory. Preprogramming and verification prior to erasure are handled
by the device, and therefore do not require system monitoring.
Notes
1. Each PPB is individually programmed and all are erased in parallel.
2. While programming PPB for the four sectors, array data can be read from any other sector, except
Sector 0 (used for Data# Polling) and the sector in which sector PPB is being programmed.
3. Entry command disables reads and writes for the sector selected.
4. Reads within that sector return the PPB status for that sector.
5. All Reads must be performed using the read mode.
6. The specific sector address are written at the same time as the program command.
7. If the PPB Lock Bit is set, the PPB Program or erase command does not execute and times-out
without programming or erasing the PPB.
8. There are no means for individually erasing a specific PPB and no specific sector address is
required for this operation.
9. Exit command must be issued after the execution which resets the device to read mode and reenables reads and writes for Sector 0.
10. The programming state of the PPB for given sectors can be verified by writing a PPB Status Read
Command to the device as described by the flow chart shown in Figure 9.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
34
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Figure 9. PPB Program Algorithm
Note: BA = base address
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
35
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Dynamic Protection Bits
Dynamic Protection Bits are volatile and unique for each sector and can be individually modified. DYBs
only control the protection scheme for unprotected sectors that have their PPBs cleared (erased to “1”).
By issuing the DYB Set or Clear command sequences, the DYBs are set (programmed to “0”) or cleared
(erased to “1”), thus placing each sector in the protected or unprotected state respectively. This feature
allows software to easily protect sectors against inadvertent changes yet does not prevent the easy
removal of protection when changes are needed.
Notes
1. The DYBs can be set (programmed to “0”) or cleared (erased to “1”) as often as needed. When the
parts are first shipped, the PPBs are cleared (erased to “1”) and upon power up or reset, the
DYBs can be set or cleared depending upon the ordering option chosen.
2. If the option to clear the DYBs after power up is chosen, (erased to “1”), then the sectorsmay be
modified depending upon the PPB state of that sector (see Table 8).
3. The sectors would be in the protected state If the option to set the DYBs after power up is chosen
(programmed to “0”).
4. It is possible to have sectors that are persistently locked with sectors that are left in the dynamic
state.
5. The DYB Set or Clear commands for the dynamic sectors signify protected or unprotectedstate of
the sectors respectively. However, if there is a need to change the status of the persistently locked
sectors, a few more steps are required. First, the PPB Lock Bit must be cleared by either putting
the device through a power-cycle, or hardware reset. The PPBs can then be changed to reflect the
desired settings. Setting the PPB Lock Bit once again locks the PPBs, and the device operates
normally again.
6. To achieve the best protection, it is recommended to execute the PPB Lock Bit Set command early
in the boot code and protect the boot code by holding WP#/ACC = VIL. Note that the PPB and DYB
bits have the same function when WP#/ACC = VHH as they do when ACC =VIH.
Persistent Protection Bit Lock Bit
The Persistent Protection Bit Lock Bit is a global volatile bit for all sectors. When set (programmed to
“0”), it locks all PPBs and when cleared (programmed to “1”), allows the PPBs to be changed. There is
only one PPB Lock Bit per device.
Notes
1. No software command sequence unlocks this bit unless the device is in the password protection
mode; only a hardware reset or a power-up clears this bit.
2. The PPB Lock Bit must be set (programmed to “0”) only after all PPBs are configured to the
desired settings.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
36
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Figure 10. Lock Register Program Algorithm
Advanced Sector Protection Software Examples
Table 8. Sector Protection Schemes: DYB, PPB and PPB Lock Bit Combinations
Table 8 contains all possible combinations of the DYB, PPB, and PPB Lock Bit relating to the status of
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
37
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
the sector. In summary, if the PPB Lock Bit is locked (set to “0”), no changes to the PPBs are allowed.
The PPB Lock Bit can only be unlocked (reset to “1”) through a hardware reset or power cycle. See also
Figure 8 for an overview of the Advanced Sector Protection feature.
Hardware Data Protection Methods
The device offers two main types of data protection at the sector level via hardware control:
• When WP#/ACC is at VIL, the either the highest or lowest sector is locked (device specific).
There are additional methods by which intended or accidental erasure of any sectors can be prevented
via hardware means. The following subsections describes these methods:
WP#/ACC Method
The Write Protect feature provides a hardware method of protecting one outermost sector. This function
is provided by the WP#/ACC pin and overrides the previously discussed Sector Protection/Unprotection
method.
If the system asserts VIL on the WP#/ACC pin, the device disables program and erase functions in the
highest or lowest sector independently of whether the sector was protected or unprotected using the
method described in Advanced Sector Protection/Unprotection on page 26.
If the system asserts VIH on the WP#/ACC pin, the device reverts to whether the boot sectors were last
set to be protected or unprotected. That is, sector protection or unprotection for these sectors depends
on whether they were last protected or unprotected.
The WP#/ACC pin must be held stable during a command sequence execution. WP# has an internal
pull-up; when unconnected, WP# is set at VIH.
Note
If WP#/ACC is at VIL when the device is in the standby mode, the maximum input load current is
increased.
Low VCC Write Inhibit
When VCC is less than VLKO, the device does not accept any write cycles. This protects data during
VCC power-up and power-down.
The command register and all internal program/erase circuits are disabled, and the device resets to
reading array data. Subsequent writes are ignored until VCC is greater than VLKO. The system must
provide the proper signals to the control inputs to prevent unintentional writes when VCC is greater than
VLKO.
Write Pulse “Glitch Protection”
Noise pulses of less than 5 ns (typical) on OE#, CE# or WE# do not initiate a write cycle.
Power-Up Write Inhibit
If WE# = CE# = RESET# = VIL and OE# = VIH during power up, the device does not accept commands
on the rising edge of WE#. The internal state machine is automatically reset to the read mode on powerup.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
38
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Power Conservation Modes
Standby Mode
When the system is not reading or writing to the device, it can place the device in the standby mode. In
this mode, current consumption is greatly reduced, and the outputs are placed in the high impedance
state, independent of the OE# input. The device enters the CMOS standby mode when the CE# and
RESET# inputs are both held at VCC ± 0.3 V. The device requires standard access time (tCE) for read
access, before it is ready to read data. If the device is deselected during erasure or programming, the
device draws active current until the operation is completed. ICC4 in “DC Characteristics” represents the
standby current specification
Automatic Sleep Mode
The automatic sleep mode minimizes Flash device energy consumption. The device automatically
enables this mode when addresses remain stable for tACC + 30 ns. The automatic sleep mode is
independent of the CE#, WE#, and OE# control signals. Standard address access timings provide new
data when addresses are changed. While in sleep mode, output data is latched and always available to
the system.
Hardware RESET# Input Operation
The RESET# input provides a hardware method of resetting the device to reading array data. When
RESET# is driven low for at least a period of tRP, the device immediately terminates any operation in
progress, tristates all outputs, and ignores all read/write commands for the duration of the RESET#
pulse. The device also resets the internal state machine to reading array data. The operation that was
interrupted should be reinitiated once the device is ready to accept another command sequence to
ensure data integrity.
When RESET# is held at VSS ± 0.3 V, the device draws ICC reset current (ICC5). If RESET# is held at
VIL but not within VSS ± 0.3 V, the standby current is greater.
RESET# may be tied to the system reset circuitry and thus, a system reset would also reset the Flash
memory, enabling the system to read the boot-up firmware from the Flash memory.
Output Disable (OE#)
When the OE# input is at VIH, output from the device is disabled. The outputs are placed in the high
impedance state. (With the exception of RY/BY#.)
Secured Silicon Sector Flash Memory Region
The Secured Silicon Sector provides an extra Flash memory region that enables permanent part
identification through an Electronic Serial Number (ESN). The Secured Silicon Sector is 128 words in
length and all Secured Silicon reads outside of the 128-word address range returns invalid data. The
Secured Silicon Sector Indicator Bit, DQ7, (at Autoselect address 03h) is used to indicate whether or not
the Secured Silicon Sector is locked when shipped from the factory.
Please note the following general conditions:
• On power-up, or following a hardware reset, the device reverts to sending commands to the normal
address space.
• Reads outside of sector SA0 return memory array data.
• Sector SA0 is remapped from memory array to Secured Silicon Sector array.
• Once the Secured Silicon Sector Entry Command is issued, the Secured Silicon Sector Exit
command must be issued to exit Secured Silicon Sector Mode.
• The Secured Silicon Sector is not accessible when the device is executing an Embedded Program or
Embedded Erase algorithm.
• The ACC function and unlock bypass modes are not available when the Secured Silicon Sector is
enabled.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
39
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Table 9. Secured Silicon Sector Addresses
Factory Locked Secured Silicon Sector
The Factory Locked Secured Silicon Sector is always protected when shipped from the factory and has
the Secured Silicon Sector Indicator Bit (DQ7) permanently set to a “1”. This prevents cloning of a
factory locked part and ensures the security of the ESN and customer code once the product is shipped
to the field.
These devices are available pre-programmed with one of the following:
• A random, 8 Word secure ESN only within the Secured Silicon Sector (at addresses 000000H 000007H)
• Both a random, secure ESN and customer code through the EON programming service.
Customers may opt to have their code programmed through the EON programming services. EON
programs the customer's code, with or without the random ESN. The devices are then shipped from the
EON factory with the Secured Silicon Sector permanently locked. Contact your local representative for
details on using EON programming services.
Customer Lockable Secured Silicon Sector
The Customer Lockable Secured Silicon Sector is always shipped unprotected (DQ7 set to “0”), allowing
customers to utilize that sector in any manner they choose. If the security feature is not required, the
Secured Silicon Sector can be treated as an additional Flash memory space.
Please note the following:
• Once the Secured Silicon Sector area is protected, the Secured Silicon Sector Indicator Bit is
permanently set to “0.”
• The Secured Silicon Sector can be read any number of times, but can be programmed and locked
only once. The Secured Silicon Sector lock must be used with caution as once locked, there is no
procedure available for unlocking the Secured Silicon Sector area and none of the bits in the
Secured Silicon Sector memory space can be modified in any way.
• The accelerated programming (ACC) and unlock bypass functions are not available when the
Secured Silicon Sector is enabled.
• Once the Secured Silicon Sector is locked and verified, the system must write the Exit Secured
Silicon Sector Region command sequence which return the device to the memory array at sector 0.
Secured Silicon Sector Entry/Exit Command Sequences
The system can access the Secured Silicon Sector region by issuing the three-cycle Enter Secured
Silicon Sector command sequence. The device continues to access the Secured Silicon Sector region
until the system issues the four-cycle Exit Secured Silicon Sector command sequence.
The Secured Silicon Sector Entry Command allows the following commands to be executed
• Read customer and factory Secured Silicon areas
• Program the customer Secured Silicon Sector
After the system has written the Enter Secured Silicon Sector command sequence, it may read the
Secured Silicon Sector by using the addresses normally occupied by sector SA0 within the memory
array. This mode of operation continues until the system issues the Exit Secured Silicon Sector
command sequence, or until power is removed from the device.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
40
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
COMMON FLASH INTERFACE (CFI)
The common flash interface (CFI) specification outlines device and host systems software
interrogation handshake, which allows specific vendor-specified software algorithms to be used for
entire families of devices. Software support can then be device-independent, JEDEC ID-independent,
and forward- and backward-compatible for the specified flash device families. Flash vendors can
standardize their existing interfaces for long-term compatibility.
This device enters the CFI Query mode when the system writes the CFI Query command, 98h, to
address 55h in word mode (or address AAh in byte mode), any time the device is ready to read array
data.
The system can read CFI information at the addresses given in Tables 10~13.In word mode, the
upper address bits (A7–MSB) must be all zeros. To terminate reading CFI data, the system must
write the reset command.
The system can also write the CFI query command when the device is in the autoselect mode. The
device enters the CFI query mode and the system can read CFI data at the addresses given in
Tables 10~13. The system must write the reset command to return the device to the autoselect
mode.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
41
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Table 10. CFI Query Identification String
Addresses
(Word Mode)
10h
11h
12h
13h
14h
15h
16h
17h
18h
19h
1Ah
Data
0051h
0052h
0059h
0002h
0000h
0040h
0000h
0000h
0000h
0000h
0000h
Description
Query Unique ASCII string “QRY”
Primary OEM Command Set
Address for Primary Extended Table
Alternate OEM Command set (00h = none exists)
Address for Alternate OEM Extended Table (00h = none exists)
Table 11. System Interface String
Addresses
(Word Mode)
Data
1Bh
0027h
1Ch
0036h
1Dh
1Eh
1Fh
20h
21h
22h
23h
24h
25h
26h
0000h
0000h
0003h
0004h
0009h
0000h
0005h
0005h
0004h
0000h
Description
Vcc Min (write/erase)
DQ7-DQ4: volt, DQ3-DQ0: 100mV
Vcc Max (write/erase)
DQ7-DQ4: volt, DQ3-DQ0: 100mV
Vpp Min voltage (00h = no Vpp pin present)
Vpp Max voltage (00h = no Vpp pin present)
N
Typical timeout per single byte/word write 2 µs
N
Typical timeout for min size buffer write 2 µs (00h = not supported)
N
Typical timeout per individual block erase 2 ms
N
Typical timeout for full chip erase 2 ms (00h = not supported)
N
Max timeout for byte/word write 2 times typical
N
Max timeout for buffer write 2 times typical
N
Max timeout per individual block erase 2 times typical
N
Max timeout for full chip erase 2 times typical (00h = not supported)
Table 12. Device Geometry Definition
Addresses
(Word mode)
27h
28h
29h
2Ah
2Bh
Data
0017h
0002h
0000h
0005h
0000h
2Ch
00xxh
2Dh
2Eh
2Fh
30h
00xxh
0000h
00x0h
000xh
Description
Device Size = 2 bytes. 2**23=8MB=64Mb
Flash Device Interface Description (refer to CFI publication 100);
01h = X16 only; 02h = x8/x16
Max number of byte in multi-byte write = 2N
(00h = not supported)
Number of Erase Block Regions within device (01h = uniform device,
02h = boot device)
Erase Block Region 1 Information
(refer to the CFI specification of CFI publication 100)
EN29GL064 H and L : 007Fh, 0000h, 0000h, 0001h
EN29GL064 B and T : 0007h, 0000h, 0020h, 0000h
31h
32h
33h
34h
00xxh
0000h
0000h
000xh
Erase Block Region 2 Information
(refer to the CFI specification of CFI publication 100)
EN29GL064 H and L : 0000h, 0000h, 0000h, 0000h
EN29GL064 B and T : 007Eh, 0000h, 0000h, 0001h
35h
36h
37h
38h
0000h
0000h
0000h
0000h
Erase Block Region 3 Information
(refer to the CFI specification of CFI publication 100)
N
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
42
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
39h
3Ah
3Bh
3Ch
0000h
0000h
0000h
0000h
EN29GL064
Erase Block Region 4 Information
(refer to the CFI specification of CFI publication 100)
Table 13. Primary Vendor-specific Extended Query
Addresses
(Word Mode)
40h
41h
42h
43h
44h
Data
0050h
0052h
0049h
0031h
0034h
45h
000Ch
46h
0002h
47h
0001h
Sector Protect
0 = Not Supported, X = Minimum number of sectors per group
48h
0000h
Sector Temporary Unprotect
00 = Not Supported, 01 = Supported
49h
0003h
Sector Protect/Unprotect Scheme
00h = High Voltage Sector Protection
01h = High Voltage + In-System Sector Protection
02h = HV + In-System + Software Command Sector Protection
03h = Software Command Sector Protection
4Ah
0000h
4Bh
0000h
4Ch
0002h
4Dh
0085h
4Eh
0095h
4Fh
000xh
50h
0001h
51h
0001h
52h
0008h
53h
000Fh
54h
0009h
55h
56h
0005h
0005h
57h
0000h
Description
Query Unique ASCII string "PRI"
Major version number, ASCII
Minor version number, ASCII
Address Sensitive Unlock (Bits 1-0)
00 = Required, 01 = Not Required
Technology (Bits 5-2) 0001 = 0.18um, 0010 = 0.13um, 0011 = 90nm
Erase Suspend
0 = Not Supported, 1 = To Read Only, 2 = To Read & Write
Simultaneous Operation
00 = Not supported, X = Number of Sectors
Burst Mode Type
00 = Not Supported, 01 = Supported
Page Mode Type
00 = Not Supported, 01 = 4 Word Page, 02 = 8 Word Page
Minimum WP#/ACC (Acceleration) Supply Voltage
00 = Not Supported, DQ7-DQ4: Volts, DQ3=DQ0: 100mV
Maximum WP#/ACC (Acceleration) Supply Voltage
00 = Not Supported, DQ7-DQ4: Volts, DQ3=DQ0: 100mV
Top/Bottom Boot Sector Flag
02 = Bottom Boot Device, 03 = Top Boot Device
04 = Uniform sectors bottom WP# protect
05 = Uniform sectors top WP# protect
Program Suspend
00 = Not Supported, 01 = Supported
Accelerated Program (Unlock Bypass mode)
00 = Not Supported, 01 = Supported
N
Secured Silicon Sector (Customer OTP Area) Size 2 bytes
Hardware Reset Low Time-out during an embedded algorithm to read
N
mode Maximum 2 ns
Hardware Reset Low Time-out not during an embedded algorithm to
N
read mode Maximum 2 ns
N
Erase Suspend Latency Maximum 2 µs
N
Program Suspend Latency Maximum 2 µs
Bank Organization
00 = Data at 4Ah is zero, X = Number of Banks
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
43
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Cycles
Table 14-1. EN29GL064 Command Definitions
Command
Sequence
Bus Cycles
1
st
Cycle
Addr
Data
P
P
Read
1
RA
RD
Reset
1
XXX
F0
Autoselect
Manufacturer
ID
Word
Byte
Device ID
Uniform
Word
Byte
Device ID
Top Boot
Word
Device ID
Bottom Boot
Sector Protect
Verify
Program
Byte
Word
Byte
Word
Byte
Word
Byte
4
4
4
4
4
4
555
AAA
555
AAA
555
AAA
555
AAA
555
AAA
555
AAA
AA
AA
AA
AA
AA
Write to Buffer
6
Program Buffer to Flash
1
SA
29
Write to Buffer Abort Reset
3
555
AA
Chip Erase
Sector Erase
Word
Byte
Word
Byte
6
6
555
AA
555
AAA
555
AAA
AA
AA
AA
Sector Erase Suspend
1
XXX
B0
Sector Erase Resume
1
XXX
30
Word
Byte
Accelerated Program
CFI Query
1
2
55
AA
XX
2
nd
Cycle
Addr
Data
P
P
2AA
555
2AA
555
2AA
555
2AA
555
2AA
555
2AA
555
55
55
55
55
55
55
3
rd
Cycle
Addr
Data
P
P
555
AAA
555
AAA
555
AAA
555
AAA
555
AAA
555
AAA
90
90
90
90
90
55
555
F0
55
55
555
AAA
555
AAA
80
80
th
7F
1C
7F
1C
227E
7E
X0E
X1C
220C
0C
X0F
X1E
2201
01
X01
227E
X0E
2210
X0F
2201
7E
X1C
X0E
X1C
10
2210
10
X1E
X0F
X1E
01
2200
00
PA
PD
WBL
PD
X02
X01
X02
(SA)
X02
(SA)
X04
227E
7E
555
AAA
555
AAA
P
P
P
Addr
AA
AA
2AA
555
2AA
555
55
55
555
AAA
SA
98
A0
PA
PD
Legend
X = Don’t care
RA = Address of the memory to be read.
RD = Data read from location RA during read operation.
PA = Address of the memory location to be programmed. Addresses latch on
the falling edge of the WE# or CE# pulse, whichever happens later.
PD = Data to be programmed at location PA. Data latches on the rising edge
of the WE# or CE# pulse, whichever happens first.
SA = Address of the sector to be verified (in autoselect mode) or erased.
Address bits Amax–A16 uniquely select any sector.
WBL = Write Buffer Location. The address must be within the same write
buffer page as PA.
WC = Word Count is the number of write buffer locations to load minus 1.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
44
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
P
Cycle
Data
00
01
00
01
WC
2AA
6
000
100
000
200
X01
X02
SA
25
th
Cycle
Addr Data
PD
SA
5
Cycle
Addr Data
P
PA
55
555
2AA
555
th
P
A0
2AA
2AA
4
www.eonssi.com
10
30
Preliminary
EN29GL064
Command
Sequence
Lock Register
st
2
nd
Cycle
Addr Data
Cycle
Addr Data
P
P
P
P
3
rd
Cycle
Addr
Data
P
P
3
555
AA
2AA
55
555
40
3
AAA
AA
55
55
AAA
40
2
XXX
A0
XXX
Data
Read
1
00
RD
Command Set Exit
2
XXX
90
XXX
00
3
555
AA
2AA
55
555
C0
AAA
C0
PPB Command
Set Entry
Global
Non-Volatile
Global
1
Byte
Program
Volatile Freeze
Bus Cycles
Word
Command Set
Entry
Word
3
AAA
AA
55
55
PPB Program
2
XXX
A0
SA
00
All PPB Erase
2
XXX
80
00
30
Byte
PPB Status Read
1
SA
RD
PPB Command Set Exit
2
XXX
90
XXX
00
PPB Lock
Command Set
Entry
PPB Lock Set
Word
3
555
AA
2AA
55
555
50
Byte
3
AAA
AA
555
55
AAA
50
XXX
00
2
XXX
A0
PPB Lock Status Read
PPB Lock Command Set
Exit
1
XXX
RD
2
XXX
90
XXX
00
Word
3
555
AA
2AA
55
555
E0
Byte
3
AAA
AA
555
55
AAA
E0
DYB Set
2
XXX
A0
SA
00
DYB Clear
2
XXX
A0
SA
01
DYB Status Read
1
SA
RD
DYB Command Set Exit
2
XXX
90
XXX
00
DYB Command
Set Entry
Volatile
Cycles
Table 14-2. EN29GL064 Command Definitions
4
th
Cycle
Addr Data
P
P
5
th
Cycle
Addr Data
P
P
6
45
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
P
Addr
Legend
X = Don’t care
RD(0) = Read data.
SA = Sector Address. Address bits Amax–A16 uniquely select any sector.
PWD = Password
PWDx = Password word0, word1, word2, and word3.
Data = Lock Register Contents: PD(0) = Secured Silicon Sector Protection Bit,
PD(1) = Persistent Protection Mode Lock Bit, PD(2) = Password Protection
Mode Lock Bit.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
th
P
www.eonssi.com
Cycle
Data
Preliminary
EN29GL064
Table 15. DC Characteristics
(Ta = - 40°C to 85°C; VCC = 2.7-3.6V)
Symbol
Parameter
ILO
Input Leakage Current
A9, OE#, RESET#
Input Load Current
Output Leakage Current
ICC1
VCC Active Read Current
ICC2
VCC Intra-Page Read
Current
ICC3
VCC Active Erase/
Program Current
ICC4
ILI
ILIT
Test Conditions
Min
Typ
Max
Unit
0V≤ VIN ≤ Vcc
±5
µA
VCC = VCC max; VID= 11.5 V
35
µA
0V≤ VOUT ≤ Vcc
±1
µA
5MHz
20
30
mA
10MHz
CE# = VIL , OE# = VIH , VCC =
VCCmax, f = 10 MHz
CE# = VIL , OE# = VIH , VCC =
VCCmax, f = 33 MHz
30
45
mA
1
10
5
15
CE# = VIL , OE# = VIH , VCC = VCCmax
20
30
mA
VCC Standby Current
CE#, RESET# = VCC ± 0.3 V,
OE# = VIH , VCC = VCC max
VIL = Vss + 0.3 V/-0.1V,
1
5.0
µA
ICC5
VCC Reset Current
RESET# = Vss ± 0.3V
1
5.0
µA
ICC6
Automatic Sleep Mode
VIH = Vcc ± 0.3V
VIL = Vss ± 0.3V
1
5.0
µA
CE# = VIL; OE# = VIH ;
VCC = VCC max
mA
VIL
Input Low Voltage
-0.5
VIH
Input High Voltage
0.7 x
VIO
0.3 x
VIO
VIO +
0.3
10.5
11.5
V
10.5
11.5
V
0.15 x
VIO
V
VHH
VID
Acceleration Program
Voltage
Voltage for Autoselect or
Temporary Sector
Unprotect
VOL
Output Low Voltage
IOL = 100
VOH
Output High Voltage
CMOS
IOH = -100
VLKO
Supply voltage (Erase and
Program lock-out)
A
0.85 x
VIO
A
2.3
V
V
V
2.5
V
Notes:
1. BYTE# pin can also be GND ± 0.3V. BYTE# and RESET# pin input buffers are always enabled so that they draw power if not
at full CMOS supply voltages.
2. Maximum ICC specifications are tested with Vcc = Vcc max.
3. Not 100% tested.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
46
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Figure 11. Test Conditions
Table 16. Test Specifications
Test Conditions
-70
Unit
Output Load Capacitance, CL
30
pF
Input Rise and Fall times
5
ns
Input Pulse Levels
Input timing measurement reference
levels
Output timing measurement
reference levels
0.0-VIO
V
0.5 VIO
V
0.5 VIO
V
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
47
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
AC CHARACTERISTICS
Table 17. Read-only Operations Characteristics
Parameter
Symbols
Speed
Test Setup
Description
JEDEC
Standard
tAVAV
tRC
Read Cycle Time
tAVQV
tACC
Address to Output Delay
tELQV
tCE
Chip Enable To Output Delay
tPACC
tGLQV
Unit
-70
Min
70
ns
CE# = VIL
OE#= VIL
Max
70
ns
OE#= VIL
Max
70
ns
Page Access Time
Max
25
ns
tOE
Output Enable to Output Delay
Max
30
ns
tEHQZ
tDF
Chip Enable to Output High Z
Max
20
ns
tGHQZ
tDF
Output Enable to Output High Z
Max
20
ns
tAXQX
tOH
Output Hold Time from
Addresses, CE# or OE#,
whichever occurs first
Min
0
ns
tOEH
Output Enable
Hold Time
Min
0
ns
Min
10
ns
Read
Toggle and
DATA# Polling
Notes: High Z is Not 100% tested.
Figure 12. AC Waveforms for READ Operations
tRC
Addresses
Addresses Stable
tACC
CE#
tDF
tOE
OE#
tOEH
WE#
tCE
tOH
HIGH Z
Outputs
Output Valid
HIGH Z
RESET#
RY/BY#
0V
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
48
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Figure 13. Page Read Operation Timings
Note: Addresses are A2:A-1 for byte mode.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
49
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
AC CHARACTERISTICS
Table 18. Hardware Reset (RESET#)
Parameter
Std
tRP1
tRP2
tRH
tRB1
tRB2
tREADY1
tREADY2
Description
RESET# Pulse Width (During Embedded Algorithms)
RESET# Pulse Width (NOT During Embedded Algorithms)
Reset# High Time Before Read
RY/BY# Recovery Time ( to CE#, OE# go low)
RY/BY# Recovery Time ( to WE# go low)
Reset# Pin Low (During Embedded Algorithms)
to Read or Write
Reset# Pin Low (NOT During Embedded Algorithms)
to Read or Write
Test
Setup
Min
Min
Min
Min
Min
Speed
-70
10
500
50
0
50
Max
20
us
Max
500
ns
Unit
us
ns
ns
ns
ns
Figure 14. AC Waveforms for RESET#
Reset# Timings
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
50
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
AC CHARACTERISTICS
Table 19. Word / Byte Configuration (BYTE#)
Std
Parameter
tBCS
tCBH
tRBH
Speed
-70
0
0
0
Test
Setup
Description
Byte# to CE# switching setup time
CE# to Byte# switching hold time
RY/BY# to Byte# switching hold time
Min
Min
Min
Unit
ns
ns
ns
Figure 15. AC Waveforms for BYTE#
CE#
OE#
Byte#
tCBH
tBCS
Byte# timings for Read Operations
CE#
WE#
Byte#
tRBH
tBCS
RY/BY#
Byte #timings for Write Operations
Note: Switching BYTE# pin not allowed during embedded operations
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
51
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
AC CHARACTERISTICS
Table 20. Write (Erase/Program) Operations
Parameter
Symbols
Speed
Description
Unit
JEDEC
Standard
tAVAV
tWC
Write Cycle Time
Min
70
ns
tAVWL
tAS
Address Setup Time
Min
0
ns
tWLAX
tAH
Address Hold Time
Min
45
ns
tDVWH
tDS
Data Setup Time
Min
30
ns
tWHDX
tDH
Data Hold Time
Min
0
ns
Read
Toggle and
DATA# Polling
Read Recovery Time before
Write (OE# High to WE# Low)
MIn
0
ns
Min
10
ns
Min
0
ns
tOEH
-70
Output Enable
Hold Time
tGHWL
tGHWL
tELWL
tCS
CE# SetupTime
Min
0
ns
tWHEH
tCH
CE# Hold Time
Min
0
ns
tWLWH
tWP
Write Pulse Width
Min
35
ns
tWHDL
tWPH
Write Pulse Width High
Min
20
ns
Write Buffer Program
Operation (Note 2, 3)
Typ
115.2
µs
Typ
8
µs
Max
200
µs
Typ
0.1
s
Max
2
s
tWHWH1
tWHWH1
Programming Operation
(Word AND Byte Mode)
tWHWH2
tWHWH2
Sector Erase Operation
tWHWH3
tWHWH3
Chip Erase Operation
Typ
16
s
tVHH
VHH Rise and Fall Time
Min
250
ns
tVCS
Vcc Setup Time
Min
50
µs
WE# High to RY/BY# Low
Max
70
ns
Recovery Time from RY/BY#
Min
0
ns
t BUSY
B
tRB
Notes: 1. Not 100% tested.
2. See table.23 Erase and Programming Performance for more information.
3. For 1~16 words bytes programmed.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
52
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
AC CHARACTERISTICS
Table 21. Write (Erase/Program) Operations
Alternate CE# Controlled Writes
Parameter
Symbols
Speed
Description
Unit
JEDEC
Standard
tAVAV
tWC
Write Cycle Time
Min
70
ns
tAVEL
tAS
Address Setup Time
Min
0
ns
tELAX
tAH
Address Hold Time
Min
45
ns
tDVEH
tDS
Data Setup Time
Min
30
ns
tEHDX
tDH
Data Hold Time
Min
0
ns
tGHEL
tGHEL
Read Recovery Time before
Write (OE# High to CE# Low)
Min
0
ns
tWLEL
tWS
WE# SetupTime
Min
0
ns
tEHWH
tWH
WE# Hold Time
Min
0
ns
tELEH
tCP
Write Pulse Width
Min
35
ns
tEHEL
tCPH
Write Pulse Width High
Min
20
ns
Write Buffer Program Operation
(Note 2, 3)
Typ
115.2
µs
Typ
8
µs
Max
200
µs
Typ
0.1
s
Max
2
s
tWHWH1
tWHWH2
tWHWH1
tWHWH2
-70
Programming Operation
(Byte AND word mode)
Sector Erase Operation
Notes: 1. Not 100% tested.
2. See table.23 Erase and Programming Performance for more information.
3. For 1~16 words bytes programmed.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
53
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
AC CHARACTERISTICS
Figure 16. AC Waveforms for Chip/Sector Erase Operations Timings
Erase Command Sequence (last 2 cycles)
tAS
tWC
Addresses
0x2AA
Read Status Data (last two cycles)
tAH
SA
VA
VA
0x555 for chip
erase
CE#
tGHW
tCH
OE#
tWP
WE#
tCS
tWP
0x55
Data
tDS
tWHWH2 or tWHWH3
0x30
Status
tBUS
tDH
DOUT
tRB
RY/BY#
VCC
tVCS
Notes:
1. SA=Sector Address (for sector erase), VA=Valid Address for reading status, Dout=true data at read address.
2. Vcc shown only to illustrate tvcs measurement references. It cannot occur as shown during a valid command
sequence.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
54
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Figure 17. Program Operation Timings
Program Command Sequence (last 2 cycles)
tAS
tWC
Addresses
0x555
Program Command Sequence (last 2 cycles)
tAH
PA
PA
PA
CE#
tGHWL
OE#
tCH
tWP
WE#
tWPH
tCS
Data
RY/BY#
PD
OxA0
tDS
tWHWH1
tDH
Status
DOUT
tRB
tBUSY
tVCS
VCC
Notes:
1. PA=Program Address, PD=Program Data, DOUT is the true data at the program address.
2. VCC shown in order to illustrate tVCS measurement references. It cannot occur as shown during a valid
command sequence.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
55
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Figure 18. AC Waveforms for /DATA Polling During Embedded Algorithm
Operations
tRC
Addresses
VA
VA
VA
tACC
tCH
tCE
CE#
tOE
OE#
tOEH
tDF
WE#
tOH
DQ[7]
Complement
DQ[6:0]
Complement
Status
Data
Status Data
True
Valid Data
True
Valid Data
tBUSY
RY/BY#
Notes:
1. VA=Valid Address for reading Data# Polling status data
2. This diagram shows the first status cycle after the command sequence, the last status read cycle and the array data read cycle.
Figure 19. AC Waveforms for Toggle Bit During Embedded Algorithm
Operations
tRC
Addresses
VA
VA
VA
VA
tACC
tCH
tCE
CE#
tOE
OE#
tOEH
WE#
tDF
tOH
DQ6, DQ2
tBUSY
Valid Status
Valid Status
Valid Status
(first read)
(second read)
(stops toggling)
Valid Data
RY/BY#
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
56
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Figure 20. Alternate CE# Controlled Write Operation Timings
0x555 for Program
0x2AA for Erase
PA for Program
SA for Sector Erase
0x555 for Chip Erase
Addresses
VA
tWC
tAS
tAH
WE#
tWH
tGHEL
OE#
tCP
tWS
tCPH
tCWHWH1 / tCWHWH2 / tCWHWH3
CE#
tDS
tBUSY
tDH
Data
Status
0xA0 for Program
0x55 for Erase
DOUT
PD for Program
0x30 for Sector Erase
0x10 for Chip Erase
RY/BY#
tRH
Reset#
Notes:
PA = address of the memory location to be programmed.
PD = data to be programmed at byte address.
VA = Valid Address for reading program or erase status
Dout = array data read at VA
Shown above are the last two cycles of the program or erase command sequence and the last status read cycle
Reset# shown to illustrate tRH measurement references. It cannot occur as shown during a valid command
sequence.
Figure 21. DQ2 vs. DQ6
Enter
Embedded
Erase
WE#
Enter Erase
Suspend
Program
Erase
Suspend
Erase
Enter
Suspend
Read
Erase
Resume
Enter
Suspend
Program
Erase
Suspend
Read
Erase
Erase
Complete
DQ6
DQ2
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
57
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Table 22. Temporary Sector Unprotect
Parameter
Std
tVIDR
VID Rise and Fall Time
RESET# Setup Time for Temporary
Sector Unprotect(Note)
tRSP
Speed Option
-70
Unit
Min
500
ns
Min
4
µs
Description
Notes: Not 100% tested.
Figure 22. Temporary Sector Unprotect Timing Diagram
VID
RESET#
0 or 3 V
0 or 3 V
tVIDR
tVIDR
CE#
WE#
tRSP
RY/BY#
Figure 23. Sector Protect/Unprotect Timing Diagram
VID
RESET#
Vcc
0V
0V
tVIDR
tVIDR
SA,
A6,A1,A0
Data
60h
Valid
Valid
Valid
60h
40h
Status
Sector Protect/Unprotect
Verify
CE#
WE#
>0.4µS
>1µS
Sector Protect: 150 uS
Sector Unprotect: 15 mS
OE#
Notes:
Use standard microprocessor timings for this device for read and write cycles.
For Sector Protect, use A6=0, A1=1, A0=0. For Sector Unprotect, use A6=1, A1=1, A0=0.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
58
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
TABLE 23. ERASE AND PROGRAMMING PERFORMANCE
Typ
Limits
Max
Unit
Sector Erase Time
0.1
2
sec
Chip Erase Time
16
140
sec
Byte Programming Time
8
200
µs
Word Programming Time
8
200
µs
Byte
67.2
201.6
Word
33.6
100.8
Erase/Program Endurance
100K
Parameter
Chip Programming
Time
Comments
Excludes 00h programming prior
to erasure
Excludes system level overhead
sec
Minimum 100K cycles
cycles
Notes:
1. Typical program and erase times assume the following conditions: room temperature, 3V and checkboard
pattern programmed.
2. Maximum program and erase times assume the following conditions: worst case Vcc, 90 C and 100,000 cycles.
Table 24. 48 and 56-PIN TSOP PIN CAPACITANCE @ 25°C, 1.0MHz
Parameter Symbol
Parameter Description
Test Setup
Typ
Max
Unit
CIN
Input Capacitance
VIN = 0
6
7.5
pF
COUT
Output Capacitance
VOUT = 0
8.5
12
pF
CIN2
Control Pin Capacitance
VIN = 0
7.5
9
pF
Note: Test conditions are Temperature = 25°C and f = 1.0 MHz.
Table 25. DATA RETENTION
Parameter Description
Test Conditions
Min
Unit
150°C
10
Years
125°C
20
Years
Data Retention Time
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
59
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
ABSOLUTE MAXIMUM RATINGS
Parameter
Value
Storage Temperature
-65 to +150
Plastic Packages
-65 to +125
Ambient Temperature
With Power Applied
1
C
C
-55 to +125
Output Short Circuit Current
Voltage with
Respect to Ground
Unit
C
200
mA
A9, OE#, RESET#
2
and WP#/ACC
-0.5 to +11.5
V
All other pins 3
-0.5 to Vcc+0.5
V
Vcc
-0.5 to + 4.0
V
Notes:
1.
No more than one output shorted at a time. Duration of the short circuit should not be greater than one second.
2.
Minimum DC input voltage on A9, OE#, RESET# and WP#/ACC pins is –0.5V. During voltage transitions, A9, OE#, RESET# and
WP#/ACC pins may undershoot V ss to –1.0V for periods of up to 50ns and to –2.0V for periods of up to 20ns. See figure below.
Maximum DC input voltage on A9, OE#, and RESET# is 11.5V which may overshoot to 12.5V for periods up to 20ns.
3.
Minimum DC voltage on input or I/O pins is –0.5 V. During voltage transitions, inputs may undershoot V ss to –1.0V for periods of
up to 50ns and to –2.0 V for periods of up to 20ns. See figure below. Maximum DC voltage on output and I/O pins is V cc + 0.5 V.
During voltage transitions, outputs may overshoot to V cc + 1.5 V for periods up to 20ns. See figure below.
4.
Stresses above the values so mentioned above may cause permanent damage to the device. These values are for a stress rating
only and do not imply that the device should be operated at conditions up to or above these values. Exposure of the device to the
maximum rating values for extended periods of time may adversely affect the device reliability.
B
B
B
B
B
B
B
B
RECOMMENDED OPERATING RANGES 1
P
P
Parameter
Value
Ambient Operating Temperature
Industrial Devices
-40 to 85
Operating Supply Voltage
Vcc
1.
Full Voltage Range:
2.7 to 3.6V
Unit
C
V
Recommended Operating Ranges define those limits between which the functionality of the device is guaranteed.
Vcc
+1.5V
V
Maximum Negative Overshoot
Waveform
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
Maximum Positive Overshoot
Waveform
60
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
FIGURE 24. 48L TSOP 12mm x 20mm package outline
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
61
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
FIGURE 25. 56L TSOP 14mm x 20mm package outline
SYMBOL
DIMENSION IN MM
NOR
----1.00
20.00
18.40
14.00
0.50
0.22
0.60
0.15
MIN.
A
--A1
0.05
A2
0.95
D
--D1
--E
--e
--b
0.17
L
0.5
R
0.08
0
4
0
Note : 1. Coplanarity: 0.1 mm
3
0
MAX
1.20
0.15
1.05
--------0.27
0.70
0.20
5
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
0
62
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
FIGURE 26.
64 ball Fortified Ball Grid Array (FBGA), 11 X13 mm, Pitch 1mm package outline
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
63
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Purpose
Eon Silicon Solution Inc. (hereinafter called “Eon”) is going to provide its products’ top marking on
ICs with < cFeon > from January 1st, 2009, and without any change of the part number and the
compositions of the ICs. Eon is still keeping the promise of quality for all the products with the same
as that of Eon delivered before. Please be advised with the change and appreciate your kindly
cooperation and fully support Eon’s product family.
Eon products’ New Top Marking
cFeon Top Marking Example:
cFeon
Part Number: XXXX-XXX
Lot Number: XXXXX
Date Code:
XXXXX
For More Information
Please contact your local sales office for additional information about Eon memory solutions.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
64
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
ORDERING INFORMATION
EN29GL064 H
-
70
T
I
P
PACKAGING CONTENT
P = RoHS compliant
TEMPERATURE RANGE
I = Industrial (-40°C to +85°C)
PACKAGE
T = 48-pin TSOP
Z = 56-pin TSOP
B = 64-Ball Thin Fine Pitch Ball Grid Array (TFBGA)
1.0mm pitch, 11mm x 13mm package
SPEED
70 = 70ns
SECTOR for WRITE PROTECT (WP#/ACC=L)
H = highest address sector protected
L = lowest address sector protected
T = Top boot Sector
B = Bottom boot Sector
BASE PART NUMBER
EN = Eon Silicon Solution Inc.
29GL = FLASH, 3V Page Mode Flash Memory
064 = 64 Megabit (8M x 8 / 4M x 16)
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
65
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com
Preliminary
EN29GL064
Revisions List
Revision No
Description
Date
A
Preliminary
2009/03/20
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
66
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com