FERROXCUBE EI28

FERROXCUBE
DATA SHEET
E28/17/11
EI cores
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
EI cores
E28/17/11
CORES
Effective core parameters of an E / I combination
SYMBOL
PARAMETER
VALUE
28 ± 0.55
handbook, halfpage
UNIT
18.6 min.
7.25
± 0.25
Σ(I/A)
core factor (C1)
0.588
mm −1
Ve
effective volume
4120
mm 3
Ie
effective length
49.2
mm
Ae
effective area
83.7
mm 2
Amin
minimum area
83.7
mm 2
m
mass of E core
≈ 17
g
m
mass of I core
≈ 5.1
g
handbook, halfpage
12.8
± 0.2
10.75 ± 0.2
Ordering information for I cores
GRADE
TYPE NUMBER
3C90
17.3
± 0.25
MFP090
I28/3.5/11-3C90
Dimensions in mm.
Fig.1 E28/17/11 core.
handbook, halfpage
10.75
± 0.2
28 ± 0.55
3.5
± 0.2
MFP091
Dimensions in mm.
Fig.2 I28/3.5/11.
Core halves for use in combination with an I core
AL measured in combination with an I core, clamping force for AL measurements 40 ± 20 N;
AL
(nH)
GRADE
3625 ± 25 %
3C90
AIR GAP
(µm)
µe
≈ 1700
TYPE NUMBER
≈0
E28/17/11-3C90
Properties of core sets under power conditions
B (mT) at
CORE LOSS (W) at
GRADE
H = 250 A/m;
f = 25 kHz;
T = 100 °C
f = 25 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 100 kHz;
ˆ =100 mT;
B
T = 100 °C
f = 400 kHz;
ˆ =50 mT;
B
T = 100 °C
E28/17/11+I28/3.5/11-3C90
≥ 330
≤ 0.5
≤ 0.5
−
2008 Sep 01
499
Ferroxcube
EI cores
E28/17/11
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
500