ETC 103M2

HC103M2
Fast High End Humidity Sensors
for Radiosondes / Registering Balloons
Tec hnical Da ta
160 ± 40 pF
0.55pF /% RH
0...100% RH
-80...120°C (-112...248°F)
< ± 2% RH
1.9 ± 0.25% RH
response time t63 [sec]
Nominal capacitance C0 (at 30°C / 86°F)
Sensitivity
Working range humidity
temperature
Linearity error (0...98% RH)
Hysteresis
Response time RH t63
temperature [°C]
1)
Temperature dependence
Loss tangent
Maximum supply voltage
Maximum DC voltage
Operating frequency
Packaging
tray 101.6x101.6 mm (4x4”)
tape and reel
dC = -0.0019*RH*(T-30°C) [pF]
< 0.05
5V max (UPP)
< 5mV
10...100 kHz, recommended 20kHz
240 sensors
refer to ordering guide
1) more details for t < -20°C on request
The average increase of capacitance over the
working range is 55pF. For the range of
0–98% RH linear approximation is possible, errors
will be lower than < ± 2% RH.
The sensor characteristic is determined by the
following linear formula:
capacitance [pF]
Char acteristics
C(RH) = C0 * [1+HC0 * RH]
with HC0 = 3420 ± 250 ppm /% RH
relative humidity [% RH]
For high accuracy requirements, the sensitivity is determined by the following polynomial:
C(RH) = C0 * [1 + HC0 * RH + K(RH)]
whereby:
V1.2
K(RH) = A1*RH+A2*RH1.5+A3*RH2+A4*RH2.5
A1 = 2.6657E-3
A2 = -9.6134E-4
-4
A3 = 1.1272E
A4 = -4.3E-6
HC103M2
Mounting Instr uctions
1 mm = 0.03937” / 1” = 25.4 mm
HC103M2
Dimensions (mm)
gold plated contact
through
PCB opening
HC103M2
contact area
To allow full access of the air, the humidity sensor should
be positioned over an opening in the printed circuit board
(PCB).
False readings because of humidity assimilation at the
front side of the PCB should be avoided as much as
possible by using gold-plated-through holes.
Assemb ling and Soldering
HC103M2 sensor series are designed for SMD automatic assembling with subsequent reflowsoldering. For more details please refer to mounting instructions.
Recommended SMD equipment:
· Automatic tooling machine with suction pipette
· Optical control for sensor identification
Or dering Guide
Or der Example
HC103M2
(103M2)
tray (240 sensors)
500 sensors per reel
HC
HC103M2
HC103M2TR1
PACKAGING
TYPE
(no code)
(TR0,5)
1000 sensors per reel
(TR1)
2500 sensors per reel
(TR2,5)
10000 sensors per reel
(TR10)
Type:
Packaging:
HC103M2
1000 sensors per
reel