JMK GG-1570-20

GG-1570-20
The GG-1570-20 power converter / Backup Battery is
a nominal 13.8 volt to 13.8 volt dc—dc converter With
a backup battery to supply power during starting etc.
This device is designed for use on trains, buses,
trucks, or other automotive devices where clean regulated electrical power is required.
The input of the converter is protected against polarity
connections. The converter is also protected against
thermal and over voltage input with automatic recovery.
The converter protects against transient up to 300
volts with an energy content of up to 10 joules.
The converter can handle vibration and shock as is
normally encountered in the automotive environment
and storage temperatures of 85o C.
The Battery backup can provide provide 2 amps for
up to 12 minutes and of course lower currents for
longer periods. The curve on page 2 shows the battery output voltage for current drains of 1.5 and 2.0
amps.
A logic signal is available in the event of a power loss.
This UPS is packaged in a small, metal enclosure for
maintenance free operation.
Sheet 1 of 4
Performance Specifications:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Input Voltage range = 10.6—16.2 VDC
Output Voltage = 13.8 VDC
Power output = 300 Watts continuous @13.8 VDC
Ripple < 1% of output
Regulation = +/- 2% Line/Load
DC Isolation (Input/Output, Input/ Chassis, Output
Chassis) = 1000 VDC
Efficiency = 87%
Short circuit protection = automatic recovery
Reverse polarity protected input
2 fused outputs
Battery backup output = 12 Volt
Battery backup engage voltage = 10.6 volt
Battery backup dis-engage voltage = 11 volt
Backup battery shut down time = 6.0 minutes
Capacity = 1.2 amp-Hr
Rapid discharge = 2.4 amp for 6 minutes
Recharge time = 1 hour from full functional discharge to 95 % of full charge.
Battery replacement life = 6-7 years
Physical Specifications:
•
•
•
•
•
•
Size: _______________ 7.0 x 9.0 x 4.5h
Finish: ______________ Black enamel (baked)
Mounting: ___________ Bracket
Net weight: __________ TBD
Marking: ____________ White permanent ink
Orbital Logo: _________ Red paint (MS 485)
Environmental Specifications:
•
•
•
•
•
•
Operating Temp.:-40 to 50o C 2
Storage temp:
-40 to 85oC
Sealing:
Splash proof and Dust proof
Humidity:
0 to 95% non condensing
Shock:
Mil-Std-810, Procedure I,
functional shock for ground
vehicles.
Vibration;
Mil-Std-810, Category 8 for
Equipment installed in
wheeled vehicles.
Note: Picture for ref only; shows 7.0 “ width rather than 9.0”.
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
EUR
JMK Inc Glasgow G13 1DN Scotland UK
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]
PH: 44-(0) 7785310729 FX: 44-(0) 141 589 1884
GG-1570-20
1.00
Sheet 2 of 4
4.500
0.25
Orbital
Transportation Management Systems
PART NO.
SERIAL NO.
TB1
+13.8 VDC OUT
+13.8 VDC OUT RTN
9.576
+12 VDC IN RTN
+12 VDC IN
0.20
4 PLCS
4.50
P1
BUS
ON
20
3.00
20
PWR
ON
1
TB1
F1
F2
9.00
10.08
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
EUR
JMK Ltd Dumbarton G82 2TS Scotland UK
6.50
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]
PH: 44-(0) 1389-751841 FX: 44-(0) 1389-751841
GG-1570-20
Sheet 3 of 4
BATTERY
CHARGER
POWER
CONVERTER/
REGULATOR
12 V IN
BACKUP
BATTERY
CONTROL
BACKUP
BATTERY
SHUTOFF
TIMER
12 V OUT
BACKUP
BATTERY
INTERRUPT
LOGIC
OUT
INTERRUPT
LOGIC
IGNITION
KEEP-ALIVE
TIMER
IGN OUT
IGN IN
5-VOLT
REG
IGNITION
RELAY
NOTES:
Backup Battery Control: Monitors the input voltage and sends a signal to activate the backup battery if the
input voltage falls below 10.6 V.
Backup Battery Shutoff Timer: Disconnects the backup battery after 6 minutes.
Ignition “Keep-Alive” Timer: Forces the “IGN OUT” signal to remain high for at least 8 minutes.
Interrupt Logic: Sets interrupt logic signal “High” if any of the following occurs.
• “12 v in” power is lost.
• “12 v in” power drops below 10.6 v.
• Driver turns off ignition.
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
EUR
JMK Ltd Dumbarton G82 2TS Scotland UK
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]
PH: 44-(0) 1389-751841 FX: 44-(0) 1389-751841
GG-1570-20
Sheet 4 of 4
BATTERY VOLTAGE vs TIME
FORSPECIFIED
DISCHARGE CURRENT
13
BATTERY VOLTAGE
12
1.5 AMPS
11
2.0 AMPS
10
9
8
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
TIME (MINUTES)
TIMING DIAGRAM
1
BACKUP BAT 0
1
INTERRUPT 0
1
V-PWR IN
0
1
V-PWR OUT
0
V-IGN IN
1
0
V-IGN OUT
1
0
T-O
POWER
OFF
T1
POWER-ON
IGN-ON
T2
PWR - ON
IGN - OFF
'NOTE 1"
T6
T3
T4
T5
PWR - OFF
AMDT
PWR - ON PWR - ON
"PWR FAIL" SHUTDOWN "REPAIRED" IGN - ON
"NOTE 2"
"STARTED"
"NOTE 2"
T8
AMDT
SHUTDOWN
COMPLETE
V-IGN OUT
T7
PWR - OFF
IGN - OFF
"NOTE 3"
"NOTE 2"
NOTE (1): ALLOWS AMDT TO POWER DOWN ITSELF AFTER "KEEP ALIVE TIMER EXPIRES.
NOTE (2): UPS TIME FOR SHUTDOWN = (6 MINUTES)