LINKCOM LAL0174-50

LAL0174-50
Broadband Access Transformer
z
z
z
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation
RoHS Compliant
Operating Temperature -40°C to 85°C
Electrical Specifications @25℃
PIN 1-4= 6.0mH ±10% @ 10KHz/0.1V/Ser.
OCL:
PIN 7-10= 6.0mH ±10%
@ 10KHz/0.1V/Ser.
PIN 1-4= 4.5 ohm Max.
D.C.R
PIN 7-10= 4.5 ohm Max.
PRI. – SEC. = 500VAC/60Hz/60Seconds/1mA
Hi-POT :
PRI. – CORE = 500VAC/60Hz/60Seconds/1mA
SEC. – CORE = 500VAC/60Hz/60Seconds/1mA
Turn Ratio:
PIN1-4 : PIN 7-10 = 1±2% :1
Dimensions (Units: mm)
Schematic
B
A
15±1
16.4±0.5
Pri
Sec
1
10
2
7
15±0.5 C
2.8+0.5/-0.3
0.6±0.1
4
3.3±0.25
1
2
3
4
5
11±0.25
10
9
8
7
LAL****
LinkCom R DATE CODE G
6
Mark
1.LAL****----LAL0174
PIN 1
13.2±0.5
TOP VIEW
2. X----PRODUCT LINE
BOTTOM VIEW
PIN 3,5,6,8,9CUT OFF
3. DATE CODE----YYWW
4. G----RoHS