MEANWELL AS-120P-20

AS-120P
120W AC-DC Single Output Desktop
series
Features :
3 pole AC inlet IEC320-C14
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
High power density 5w/in3
Fully enclosed plastic case
Approvals: UL / CUL / TUV / CCC / CB/ CE
No load power consumption<0.5W
Pass energy star level
(CEC) for 12~48V(execpt for 15V)
Meet EISA 2007(Energy Independence and Security Act)
ZCS/ZVS technology to reduce power dissipation
2 years warranty
TUV
Rheinland
Product Safety
SPECIFICATION
MODEL
AS-120P-12
AS-120P-15
AS-120P-20
AS-120P-24
AS-120P-48
AS120P12R7B
AS120P15R7B
AS120P20P1M
AS120P24P1M
AS120P48P1M
Note.2 12V
15V
20V
24V
48V
RATED CURRENT
8.4A
6.7A
6A
5A
2.5A
CURRENT RANGE
0~ 8.4A
0 ~ 6.7A
0 ~ 6A
0 ~ 5A
0 ~ 2.5A
RATED POWER
100W
100W
120W
120W
120W
100mVp-p
200mVp-p
200mVp-p
240mVp-p
ORDER NO.
DC VOLTAGE
OUTPUT
INPUT
RIPPLE & NOISE (max.) Note.3 100mVp-p
VOLTAGE TOLERANCE Note.4 4.0%
4.0%
3.0%
2.0%
2.0%
LINE REGULATION
Note.5
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION
Note.6
3.5%
3.0%
2.5%
2.0%
2.0%
SETUP, RISE TIME
3000ms, 80ms at full load
HOLD UP TIME (Typ.)
50ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
PF 0.95/230VAC
EFFICIENCY (Typ.)
85.5%
AC CURRENT (Typ.)
1.4A/115VAC
INRUSH CURRENT (Typ.)
120A/230VAC
LEAKAGE CURRENT (max.)
<1mA / 240VAC
OVERLOAD
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER TEMPERATURE
OTHERS
CONNECTOR
NOTE
89%
87.5%
14 ~ 16.8V
22.5 ~ 28V
17 ~ 21V
Protection type : Shut down o/p voltage, re-power on to recover
90
15
90%
89%
0.7A/230VAC
27 ~ 33.6V
53.3 ~ 67.2V
(RTH2) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, re-power on to recover
0 ~ + 50
WORKING HUMIDITY
20% ~ 90% RH non-condensing
SAFETY STANDARDS
(Note. 7)
PF 0.98/115VAC at full load
WORKING TEMP.
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
EMC
16ms/115VAC at full load
127 ~ 370VDC
POWER FACTOR (Typ.)
PROTECTION OVER VOLTAGE
SAFETY &
geprUfre
Sicherheit
(Refer to output load derating curve)
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 3AXES 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, CCC GB4943 approved
WITHSTAND VOLTAGE
I/P-O/P:4.25KVDC
I/P-O/P:100M Ohms / 25 / 70% RH
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION Compliance to EN55022(CISPR22) class B, FCC part 15J class B
HARMONIC CURRENT
Compliance to EN61000-3-2,3
EMS IMMUNITY
LIFE
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
Average life expectancy of 6 years (12 hours / day, 70% load, 115VAC)
MTBF
308.9K hrs min.
DIMENSION
PACKING
PLUG
167*67*35mm (L*W*H)
0.52Kg; 30pcs/16.6Kg/1.1CUFT
Standard type R7B,P1M: 2.5 * 5.5
MIL-HDBK-217F (25
)
CABLE
Standard type 120cm of SPT-1, 18Awg*4c for stock ; Other type available by customer requested
* 11mm, center positive for stock ; Other type available by customer requested
1.All parameters are specified at 230VAC input, rated load, 25 70% RH. Ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerence: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 0% to 100% rated load.
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:AS-120P-SPEC 2008-08-25
AS-120P
120W AC-DC Single Output Desktop
Mechanical Specification
Case No.947A
series
Unit:mm
167
35
67
1200 50
2 3
1 4
18AWG 4C
167
35
67
1200 50
11
C"+"
Outside
16AWG 2C
Inside
Plug Assignment
Standard plug(For 20V,24V,48V only)
Standard plug(For 12V,15V only)
11
R7B
PIN NO OUTPUT
2
1
3
4
C"+"
P1M
1,4
+V
2,3
-V
P/N
OUTPUT
CENTER
+
ID 2.5 x OD 5.5
Outside
Derating Curve
Inside
Static Characteristics
Ta=25
100
100
90
80
80
70
50
LOAD (%)
LOAD (%)
60
40
20
0
10
20
30
40
50
60
AMBIENT TEMPERATURE ( )
70
(HORIZONTAL)
60
50
40
90
95
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:AS-120P-SPEC 2008-08-25