MEANWELL PS-05-48

PS-05
5W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range
Low leakage current <0.5mA
Protections: Short circuit/Over load /Over voltage/Over temperature
Cooling by free air convection
100% full load burn-in test
Fix switching frequency at 67KHz
Low cost
High reliability
2 years warranty
SPECIFICATION
MODEL
OUTPUT
INPUT
PS-05-5
PS-05-12
PS-05-15
PS-05-24
DC VOLTAGE
5V
12V
15V
24V
48V
RATED CURRENT
1A
0.45A
0.35A
0.22A
0.11A
CURRENT RANGE
0 ~ 1.2A
0 ~ 0.5A
0 ~ 0.4A
0 ~ 0.25A
0 ~ 0.125A
RATED POWER
5W
5.4W
5.25W
5.28W
5.28W
120mVp-p
120mVp-p
200mVp-p
200mVp-p
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE TOLERANCE Note.3
2.0%
2.0%
2.0%
2.0%
1.0%
LINE REGULATION
1.0%
1.0%
1.0%
0.5%
0.5%
LOAD REGULATION
1.0%
1.0%
1.0%
0.5%
0.5%
SETUP, RISE TIME
1000ms, 20ms
HOLD UP TIME(Typ.)
100ms at full load
VOLTAGE RANGE
85 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
70%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.15A/115VAC
LEAKAGE CURRENT
OVER LOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
(Note 4)
HARMONIC CURRENT
OTHERS
NOTE
PS-05-48
120 ~ 370VDC
75%
75%
76%
COLD START 30A/230VAC
<0.5mA / 240VAC
Above 105% rated output power
Protection type : Hiccup mode, recovery automatically after fault condition is removed
5.75 ~ 6.75V
13.8 ~ 16.2V
17.2 ~ 20.2V
27.6 ~ 32.4V
Tj 140 typically (U1) Detect on main control IC
55.2 ~ 64.8V
Protection type : Hiccup mode, recovery automatically after fault condition is removed
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
EN60950-1 CB Approved by TUV
I/P-O/P:3KVAC
I/P-O/P:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11 Light industry level, criteria A
DIMENSION
75*40*20mm (L*W*H)
0.05Kg; 120pcs/6.25Kg/1CUFT
PACKING
76%
0.07A/230VAC
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:PS-05-SPEC 2006-04-13
PS-05
5W Single Output Switching Power Supply
Mechanical Specification
series
Unit:mm
75
67
To chassis Grounding
32
40
1
2
CN1
3
1
2
CN2
3.5
20
4-
AC Input Connector (CN2) : Molex 5285-03 or equivalent
Assignment
FG
AC/N
AC/L
Pin No.
1
2
3
Mating Housing
Terminal
Molex 5058
or equivalent
Molex 2478
or equivalent
DC Output Connector (CN1) : Molex 5273-02 or equivalent
Pin No.
1
2
Assignment
+V
-V
Mating Housing
Molex 5195
or equivalent
Terminal
Molex 5194
or equivalent
Block Diagram
fosc : 67KHz
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
PWM
CONTROL
FG
DETECTION
CIRCUIT
Output Derating
Static Characteristics
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
60
50
40
-10
-10
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
(HORIZONTAL)
85
90
95
100
105
264
INPUT VOLTAGE (V) 60Hz
File Name:PS-05-SPEC 2006-04-13