MPD LF122DI

LF100DI Series
High Isolation, 1W
Dual Output SMT
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
• 1W Output Power
• Ultra-Miniature SMT Case
• 3,000 VDC Isolation
• 5V, 12V & 24V Inputs
• -40ºC to +85ºC Operation
• 9 Standard Models
• 2.0 MH MTBF Minimum
• Industry Standard Pin-Out
Parameter
Input Voltage Range
Conditions
Min.
Typ.
Max.
5 VDC Input
4.5
5.0
5.5
12 VDC Input
10.8
12.0
13.2
24 VDC Input
21.6
24.0
26.4
Reverse Polarity Input Current
Input Filter
VDC
0.3
A
Capacitor
Output
Parameter
Conditions
Min.
Typ.
Max.
Units
±1.5
±4.0
%
Balanced Loads
±0.1
±1.0
%
For Vin Change of 1%
±1.2
±1.5
%
100
mV P - P
150
mV P - P
5
mv rms
±0.02
%/ºC
Max.
Units
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation (Note 1)
See Model Selection Guide
Ripple & Noise (20 MHz) (Note 2)
Ripple & Noise (20 MHz)
75
Over Line, Load & Temp.
Ripple & Noise (20 MHz)
Output Power Protection
120
Temperature Coefficient
RoHS Compliant
Units
%
±0.01
Output Short Circuit
Momentary (0.5 Sec.)
General
Parameter
Conditions
Isolation Voltage
Min.
60 Seconds
Isolation Resistance
500 VDC
Isolation Capacitance
VDC
10
100 kHz, 1V
Switching Frequency
Typ.
3,000
GΩ
60
100
pF
50
100
150
kHz
Units
Environmental
Min.
Typ.
Max.
Operating Temperature Range
Parameter
Conditions
Ambient
-40
+25
+85
ºC
Operating Temperature Range
Case
-40
+90
ºC
-40
+125
ºC
95
%
Storage Temperature Range
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Cooling
Humidity
Free Air Convection
RH, Non-condensing
Physical
Case Size
0.60 x 0.31 x 0.26 Inches (15.24 x 8.0 x 6.7 mm)
Case Material
Molded Black Plastic (UL94-V0)
Weight
0.07 Oz (2.2g)
Reliability Specifications
Parameter
MTBF
Conditions
Min.
MIL HDBK 217F, 25ºC, Gnd Benign
2.0
Conditions
Min.
Typ.
Max.
Units
MHours
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Typ.
Max.
5 VDC Input
-0.7
9.0
12 VDC Input
-0.7
18.0
24 VDC Input
-0.7
30.0
Units
VDC
1.5 mm From Case For 10 Sec.
300
ºC
All Models
550
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Output
Load
Voltage Current
Current Regulation
Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max)
Current (mA)
Efficiency
(%, Typ)
Fuse Rating
Slow-Blow
(mA)
Nominal
Range
LF101DI
5
4.5 - 5.5
277
30
±5.0
±100.0
±2.0
10
72
500
LF102DI
5
4.5 - 5.5
255
30
±12.0
±42.0
±0.8
7
78
500
LF103DI
5
4.5 - 5.5
258
30
±15.0
±34.0
±0.7
7
79
500
LF111DI
12
10.8 - 13.2
112
12
±5.0
±100.0
±2.0
8
74
200
LF112DI
12
10.8 - 13.2
105
12
±12.0
±42.0
±0.8
5
80
200
LF113DI
12
10.8 - 13.2
104
12
±15.0
±34.0
±0.7
5
81
200
LF121DI
24
21.6 - 26.4
57
7
±5.0
±100.0
±2.0
8
72
100
LF122DI
24
21.6 - 26.4
53
7
±12.0
±42.0
±0.8
5
79
100
LF123DI
24
21.6 - 26.4
53
7
±15.0
±34.0
±0.7
5
80
100
Notes:
1. Load regulation is measured for an output change of 20% to
100%.
2. When measuring output ripple, it is recommended that an external
0.33 µF ceramic capacitor be placed from the +Vout pin to the -Vout
pin. For noise sensitive applications, the use of 0.47 µF capacitors will
reduce the output ripple.
3. Operation at no-load will not damage these units. However, they
may not meet all specifications.
4. The converter should be connected to a low ac-impedance source.
An input source with a highly inductive impedance may affect the
stability of the converter. In applications where the converter output
loading is high and input power is supplied over long lines, it may
be necessary to use a capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0Ω at 100 kHz)
capacitor be mounted close to the converter. For 5V input units a 2.2
µF is recommended, for 12V input units, a 1.0 µF, and for 24V input
units, a 0.47 µF.
5. Dual output units may be connected to provide a 10 VDC, 24 VDC or
30 VDC output. To do this, connect the load across the positive (+Vout)
and negative (-Vout) outputs and float the output common.
6. It is recommended that a fuse be used on the input of a power supply
for protection. See the table above for the correct rating.
Derating Curve
Mechanical Dimensions
Board Layout
Pin Connections
Pin
Description
Pin
Description
1
-Vin
7
NA
2
+Vin
8
+Vout
3
NA
10
NA
5
Common
11
NA
6
-Vout
12
NA
NA = Not available for connection
Capacitive Load
MicroPower Direct
±5V Out
µF Max
±12 & ±15V Out
µF Max
10
2.2
Notes:
• All dimensions are typical in inches (mm)
• Tolerance: Inches x.xx = ±0.01
Millimeters x.x = ±0.25
x.xx = ±0.13
Pin: ±0.002 (±0.05)
• Pin 1 is marked by a “dot” or indentation
on the unit. The curved edge of the case
indicates the Pin 1 side.
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]