NEWHAVEN NHD-C12864AZ-FSY-YBW

 NHD‐C12864AZ‐FSY‐YBW COG (Chip‐On‐Glass) Liquid Crystal Display Module NHD‐ C12864‐ AZ‐ F‐ SY‐ Y‐ B‐ W‐ Newhaven Display 128 x 64 pixels Model Transflective Side Yellow/Green LED Backlight STN‐ Yellow/Green 6:00 view Wide Temp (‐20°C ~ +70°C) RoHS Compliant Newhaven Display International, Inc. 2511 Technology Drive, Suite 101 Elgin IL, 60124 Ph: 847‐844‐8795 Fax: 847‐844‐8796 www.newhavendisplay.com [email protected] [email protected] [1] Document Revision History Revision 0 1 2 Date 9/28/2007 1/31/2008 9/29/2009 Description Initial Release User guide reformat User guide reformat Functions and Features •
•
•
•
•
128 x 64 pixels Built‐in ST7565P controller +3.3V power supply 1/64 duty cycle; 1/9 bias RoHS Compliant [2] Changed by ‐ ‐ BE Mechanical Drawing
NHD-C12864AZ-FSY-YBW
Newhaven Display
Pin Description and Wiring Diagram Pin No. Symbol 1 2 3 4 5 6 7‐14 15 16 17 18 VSS VDD NC /RES /CS A0 VDD SCL SI A K External Connection Power Supply Power Supply ‐
MPU MPU MPU Power Supply MPU MPU Power Supply Power Supply Function Description
Ground
Power Supply for LCD and logic (+3.3V)
No Connect
Operation Active LOW Reset signal
Active LOW Chip Select Signal
Register Select. 0: instruction; 1: data Power Supply for LCD and logic (+3.3V) Serial clock Input
Serial data Input
Power supply for backlight (+5V with on‐board 6.8ohm) Ground for backlight
Recommended LCD connector: 1.0mm Pitch pins. Molex p/n: 52271‐1879 Backlight connector: ‘A’ and ‘K’ pins on the LCD connector Mates with: ‐‐‐ [4] Electrical Characteristics Item Operating Temperature Range Storage Temperature Range Supply Voltage Supply Current Supply for LCD (contrast) “H” Level input “L” Level input “H” Level output “L” Level output Backlight Supply Voltage Backlight Supply Current Symbol TOPR TSTR VDD IDD VDD‐V0 Vih Vil Voh Vol VF ILED Condition
Absolute Max
Absolute Max
Ta=25°C, VDD=5.0V
Ta=25°C Min.
‐20
‐30
2.4
‐
8.3
2.2
0
2.4
‐
Typ.
‐
‐
3.3
‐
8.7
‐
‐
‐
‐
‐
‐
4.2
80
VF=4.2V
Max. +70 +80 3.3 147 9.3 VDD 0.6 ‐ 0.4 ‐ ‐ Unit
⁰C
⁰C
V
uA
V
V
V
V
V
V
mA
Optical Characteristics Item Viewing Angle ‐ Vertical Viewing Angle ‐ Horizontal Contrast Ratio Response Time (rise) Response Time (fall) Symbol θ Φ CR Tr Tf Condition
CR 2 CR 2 Min.
‐60
‐40
‐
‐
‐
Typ.
‐
‐
6
150
150
Max. +35 +40 ‐ 250 250 Unit
⁰ ⁰ ‐ ms
ms
Controller Information Built‐in ST7565P. Download specification at http://www.newhavendisplay.com/app_notes/ST7565.pdf [5] Timing Characteristics [6] Table of Commands
[7] Example Initialization Program '''''''''''''''''''''''''''''''''''''''''''''''''''''''''' Sub Command Reset P3.7 Reset P3.4 For Writecount = 1 To 8 Rotate A , Left , 1 Reset P3.1 P1 = A Set P3.1 Next Writecount Set P3.7 End Sub '''''''''''''''''''''''''''''''''''''''''''''''''''''''''' Sub Write Reset P3.7 Set P3.4 For Writecount = 1 To 8 Rotate A , Left , 1 Reset P3.1 P1 = A Set P3.1 Next Writecount Set P3.7 End Sub '''''''''''''''''''''''''''''''''''''''''''''''''''''''''' Sub Init Waitms 100 A = &HA0 Call Command A = &HAE Call Command A = &HC0 Call Command A = &HA2 Call Command A = &H2F Call Command A = &H26 Call Command A = &H81 Call Command A = &H11 Call Command A = &HAF Call Command End Sub '''''''''''''''''''''''''''''''''''''''''''''''''''''''''' [8] Quality Information Test Item Content of Test High Temperature storage Endurance test applying the high storage temperature for a long time. Endurance test applying the low storage temperature for a long time. Endurance test applying the electric stress (voltage & current) and the high thermal stress for a long time. Endurance test applying the electric stress (voltage & current) and the low thermal stress for a long time. Endurance test applying the electric stress (voltage & current) and the high thermal with high humidity stress for a long time. Endurance test applying the electric stress (voltage & current) during a cycle of low and high thermal stress. Endurance test applying vibration to simulate transportation and use. Low Temperature storage High Temperature Operation Low Temperature Operation High Temperature / Humidity Operation Thermal Shock resistance Vibration test Static electricity test Test Condition Endurance test applying electric static discharge. 2 ‐30⁰C , 48hrs
1,2
+70⁰C 48hrs
2 ‐20⁰C , 48hrs
1,2
+40⁰C , 90% RH , 48hrs 1,2
‐0⁰C,30min ‐> 25⁰C,5min ‐> 50⁰C,30min = 1 cycle 10 cycles 10‐55Hz , 15mm amplitude. 60 sec in each of 3 directions X,Y,Z For 15 minutes VS=800V, RS=1.5kΩ, CS=100pF One time Note 1: No condensation to be observed. Note 2: Conducted after 4 hours of storage at 25⁰C, 0%RH. Note 3: Test performed on product itself, not inside a container. Precautions for using LCDs/LCMs See Precautions at www.newhavendisplay.com/specs/precautions.pdf Warranty Information and Terms & Conditions http://www.newhavendisplay.com/index.php?main_page=terms [9] Note
+80⁰C , 48hrs
3