POWERBOX SM700

LABORATORY
SM 700 Series
6 0 0 - 7 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY
Features
•
•
•
•
•
•
•
Constant voltage and constant current operation
Parallel operation master/slave
EMC standard EN61204-3
Excellent response to load change
CE marked
Optional ethernet, RS232, IEEE 488 programming
Natural convectional cooling
Specifications
OPERATING
INPUT
Input voltage
90-132/185-265VAC
Frequency
48Hz–62Hz
Inrush current
6.5A @ 230Vac, 30A @ 110Vac.
Insulation
Input – Output: 3750V rms (8mm creepage)
Input – Case: 2500V rms
Output – Case: 600VDC
OUTPUT
Output voltage
See table
Output voltage adjustment
0%–100%
Output current
See table
Output current adjustment
0%–100%
Resolution
0.03% voltage and current control with 10 turn
potentiometers.
Overvoltage protection
SM1540-D: 0-17V, SM7020-D: 0-80V,
SM3004-D: 0-350V.
Overload protection
Yes
Short circuit protection
Yes
Temperature coefficient
CV: 5x10-5 per °C, CC: 1x10-4 per °C.
Load regulation
0%–100% load see table.
Line regulation
Line ±10% – see table.
Ripple & Noise
See table.
Stability
Efficiency
87%–89% .
Switching frequency
100kHz
Thermal protection
Yes
Programming
Analogue Programming of voltage and current by
0-5V.
Programming speed
See table
Master/Slave operation
Parallel and series operation with equal current
and voltage sharing. In this way two or more SMunits can together be used as one high power unit.
Voltage and current of the units is controlled by the
master (by potentiometers or by programming).
Series operation up to 600V
Metering
Digital meters standard
Indicators
CV/CC mode, OVP triggered LEDs
MTBF
500,000hrs
BATTERY CHARGING
The CV/CC regulated power supplies are suitable for battery charging.
Ask for the special datasheet “BATTERY CHARGING WITH SM-series POWER
SUPPLIES”. This datasheet contains information about protective measures
against accidental battery reversing.
ENVIRONMENTAL
Operating temperature
-20°C to 50°C
Humidity
95% RH max, non condensing, up to 40 °C.
75% RH max, non condensing, up to 50 °C.
CV: 3x10-4, CC: 1x10-3
Storage temperature
-40°C to 85°C
Output impedance
(0-100kHz)
SM1540: <40mΩ, SM7020: <60mΩ,
SM3004: < 700mΩ.
Cooling
Natural convection
Recovery time
(50%–100% load step): 100µS; 150µS for SM
7020.
Remote sense
2V max. per lead compensation.
STANDARDS AND APPROVALS
Safety standards
EN60950 / EN61010
EMC standards
EN61204-3, EN61000-6-2
EMI standards
EN61000-6-3 (EN55022B)
MECHANICAL
Mounting
464
Bench or 19" rack mounting
LABORATORY
SM 700 Series
6 0 0 - 7 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY
Selection Table
MODEL
NUMBER
OUTPUT
VOLTAGE
(0V TO)
OUTPUT
CURRENT
(0A TO)
SM 1540D
15V
40A
10mV pk-pk
25mA pk-pk
SM 7020D
35V
20A
15mV pk-pk
15mA pk-pk
70V
10A
150V
4A
300V
2A
SM 3004D
RIPPLE & NOISE
CV
CC
PROGRAMMING
SPEED
(0V TO V MAX.)
LOAD REG.
0%–100%
CV
CC
LINE REG.
200-264VAC
CV
CC
18mS
5mV
25mA
5mV
25mA
12mS(0-35V)
5mV
12mA
5mV
12mA
20mV
3mA
20mV
3mA
40mS(0-70V)
50mV pk-pk
3mA pk-pk
14mS(0-150V)
60mS(0-300V)
OPTIONS
Screwdriver adjustment - option P001
Master / slave operation
Battery charging SM7020-D: P021, SM3004-D: P022.
Increased max. output voltage / current - option P069
Enforced secondary isolation 1000V - option P089
Power sink for 2 quadrant operation - option P140 / 141
External ISO AMP for isolated analog programming - ISO AMP Module
External ethernet power supply controller - option PSC ETH EXT
External RS232 power suply controller - option PSC 232 EXT
External IEEE488 power supply controller - PSC 488 EXT
Technical Illustrations
Your dependable power partner – www.powerbox.com.au
465