POWER-ONE PSL

PSL Series Data Sheet
6 to 12 A Switching Regulators
Input voltage up to 144 V DC
Single output of 5.1 to 48 V DC
No input-to-output isolation
Features
•
•
•
•
RoHS lead solder exemption compliant
Efficiency up to 97%
Low input-output differential voltage
No derating over temperature
Model Selection
Output
Vo nom
Io nom
[V DC]
[A]
5.1
10
5.1
11
5.1
12
12
6
12
8
12
9
15
6
15
8
15
9
24
6
24
8
24
9
36
6
36
8
48
6
Input voltage
Vi
[V DC]
8 - 80
8 - 40
7 - 40
18 - 144
15 - 80
15 - 40
22 - 144
19 - 80
19 - 40
31 - 144
29 - 80
29 - 60
44 - 144
42 - 80
58 - 144
APR 05, 2004 revised to JUN 06, 2006
Rated power
Po tot
[W]
51
56.1
61.2
72
96
108
90
120
135
144
192
216
216
288
288
Efficiency
h typ
[%]
79
79
83
89
90
90
90
91
91
94
94
94
96
96
97
Page 1 of 4
Type
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
5A10-7R
5A11-2R
5A12-7R
126-7R
128-7R
129-2R
156-7R
158-7R
159-2R
246-7R
248-7R
249-2R
366-7R
368-7R
486-7R
Options
-9, L, i, P, C, D
D1, A
www.power-one.com
PSL Series Data Sheet
6 to 12 A Switching Regulators
Input
Input voltage
No load input current
refer to selection chart
-50 mA
Output
Efficiency
Output voltage setting accuracy
Output voltage switching noise
Line regulation
Load regulation
Minimum load
Current limitation
Operation in parallel
Vi nom, Io nom
Vi nom, Io nom
IEC/EN 61204, total
Vi min - Vi max, Io nom
Vi nom, 0 - Io nom
not required
rectangular U/I characteristic
by current limitation
up to 97%
±0.6% Vo nom
typ. 0.4%
typ. ±0.3%
typ. 0.3%
0A
typ. 110% Io nom
Protection
Input reverse polarity
Input undervoltage lockout
Input transient protection
Output
Output overvoltage
with external fuse (built-in fuse with option C installed)
typ. 80% Vi min
suppressor diode
no-load, overload and short circuit proof
suppressor diode in each output
typ. 150% Vo nom
Safety
Approvals
Protection degree
Electric strength test voltage
EN 60950, UL 1950, CSA C22.2 No. 950
I/case and O/case
IP 20
500/750/1500 V DC
EMC
Electrostatic discharge
Electromagnetic field
Electr. fast transients/bursts
Surge
Conducted disturbances
Electromagnetic emissions
IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
CISPR 22/EN 55022
Environmental
Operating ambient temperature
Operating case temperature TC
Storage temperature
Operating ambient temperature
Operating case temperature TC
Storage temperature
Damp heat
Vibration, sinusoidal
Shock
Bump
Random vibration
MTBF
APR 05, 2004 revised to JUN 06, 2006
-2, Vi nom, Io nom, convection cooled
-2, Vi nom, Io nom
-2, non operational
-7, Vi nom, Io nom, convection cooled
-7, Vi nom, Io nom
-7, non operational
IEC/EN 60068-2-3
IEC/EN 60068-2-6
IEC/EN 60068-2-27
IEC/EN 60068-2-29
IEC/EN 60068-2-64
MIL-HDBK-217
Page 2 of 4
–10 to 50°C
–10 to 80°C
–25 to 100°C
–25 to 71°C
–25 to 95°C
–40 to 100°C
www.power-one.com
PSL Series Data Sheet
6 to 12 A Switching Regulators
Options
Extended temperature range
–40 - 71°C, ambient, operating
Inhibit, TTL input, output(s) enabled if left open
Output voltage adjustment
0 - 108% Vo nom
Additional internal input filter
Output voltage adjustment
±8% Vo nom
Thyristor crowbar on output
Input or output undervoltage monitoring
Test sockets for check of output voltage
Pin allocation
Pin
2
5
8
11
14
17
20
23
26
29
32
S10007
Electrical determination
Design.
R-input (or inhibit input)
R (i)
Undervoltage monitor (Option D)
D
Output voltage (negative)
Go–
Output voltage (negative)
Go–
Output voltage (positive)
Vo+
Output voltage (positive)
Vo+
Input voltage (negative)
Gi–
Input voltage (negative)
Gi–
Input voltage (positive)
Vi+
Input voltage (positive)
Vi+
Protective ground (leading pin)
APR 05, 2004 revised to JUN 06, 2006
-9
i
R
L
P
C
D/D1
A
Page 3 of 4
32 29 26 23 20 17 14 11 8 5 2
www.power-one.com
PSL Series Data Sheet
6 to 12 A Switching Regulators
Mechanical data
The regulators are designed to be inserted into 19" rack according to IEC60297-3.
Dimensions in mm.
European
Projection
168.5 (6.63")
127 (5")
20 (0.79")
107 (4.21")
100 (3.94")
M3, 4 mm deep
(for mounting screws)
Measuring point of
case temperature TC
173.7 (6.83")
36.5 (1.44")
S09027
Accessories
Isolation pads for easy and safe PCB mounting.
Ring core chokes for ripple and interference reduction.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for
use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems
without the express written consent of the respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may
change depending on the date manufactured. Specifications are subject to change without notice.
APR 05, 2004 revised to JUN 06, 2006
Page 4 of 4
www.power-one.com