POWER-SYSTEMS CBRS-4815-3K

DC-DC Converter UNIT
CBR Series ( 2W-3W REGULATED DC-DC CONVERTER )
FEATURES
z
z
3000VDC ISOLATION
HIGH EFFICIENCY
NO HEATSINK REQUIRED
LOW COST
NO EXTERNAL COMPONENTS
REQUIRED
UP TO 3W REGULATED OUTPUT
POWER
DUAL IN LINE PACKAGE
100% BURNED IN
z
z
LOW NOISE
MTBF > 850,000 HOURS
z
OUTPUT SPECIFICATIONS
z
z
z
z
z
z
z
Voltage Setpoint Accuracy
+/-3% max
Temperature Coefficient
+/-0.03%/ OC
Ripple & Noise (20MHz BW)
Line Regulation
+/-10% max
Input Filter
Pi Network
+/-0.5% max
2
+/-0.5% max
Short Circuit Protection
Current Limit Protection
Short Circuit Restart
z
Input Voltage Range
100mVp-p max
1
Load Regulation
INPUT SPECIFICATIONS
Automatic
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Cooling
z
GENERAL SPECIFICATIONS
Efficiency
60% min
3
Isolation Voltage
Isolation Resistance
-25 OC to +71 OC
Switching Frequency
25 KHz min
-55 OC to +125 OC
Isolation Capacitance
80pF max
Free-Air Convection
MTBF
Weight
ALL SPECIFICATIONS TYPICAL AT NOMINAL
Case Material
LINE,
Case Size
FULL
LOAD
,
AND
3000 VDC min
9
10 ohms min
25
O
C
UNLESS
850,000 Hours
12.0g-14.4g
Non-Conductive Plastic
31.8mm*20.3mm*10.2mm
OTHERWISE NOTED.
1
High Line to Low Line.
2
Load Regulation is for output load current change from 10% to 100%.
3
For 60 seconds
www.Power-Systems.de
Page: 1 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
CBR Series ( 2W-3W REGULATED DC-DC CONVERTER )
z SELECTION GUIDE
2W-3W OUTPUT
MODEL
NUMBER
INPUT
OUTPUT
OUTPUT
VOLTAGE VOLTAGE CURRENT
(VDC)
(VDC)
(mA)
INPUT
CURRENT(mA)
EFF
ISOLATION
FULL
NO
(%)
(VDC)
LOAD
LOAD
CBRS-0505-3K
4.5-5.5
5
400
645
80
62
3000
CBRS-0512-3K
4.5-5.5
12
165
634
80
63
3000
CBRS-0515-3K
4.5-5.5
15
133
634
80
63
3000
CBRD-0512-3K
4.5-5.5
+/-12
+/-83
634
80
63
3000
CBRD-0515-3K
4.5-5.5
+/-15
+/-66
634
80
63
3000
CBRS-1205-3K
10.8-13.2
5
400
264
40
63
3000
CBRS-1212-3K
10.8-13.2
12
165
256
40
65
3000
CBRS-1215-3K
10.8-13.2
15
200
378
45
66
3000
CBRD-1212-3K
10.8-13.2
+/-12
+/-83
256
40
65
3000
CBRD-1215-3K
10.8-13.2
+/-15
+/-100
378
45
66
3000
CBRS-2405-3K
21.6-26.4
5
400
132
20
63
3000
CBRS-2412-3K
21.6-26.4
12
165
128
20
65
3000
CBRS-2415-3K
21.6-26.4
15
200
192
25
65
3000
CBRD-2412-3K
21.6-26.4
+/-12
+/-83
128
20
65
3000
CBRD-2415-3K
21.6-26.4
+/-15
+/-100
192
25
65
3000
CBRS-4805-3K
43.2-52.8
5
400
66
10
63
3000
CBRS-4812-3K
43.2-52.8
12
165
65
10
64
3000
CBRS-4815-3K
43.2-52.8
15
200
97
12
64
3000
CBRD-4812-3K
43.2-52.8
+/-12
+/-83
65
10
64
3000
CBRD-4815-3K
43.2-52.8
+/-15
+/-100
97
12
64
3000
Note: Other input to output voltages may be available. Please contact factory.
www.Power-Systems.de
Page: 2 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
CBR Series ( 2W-3W REGULATED DC-DC CONVERTER )
z SIMPLIFIED SCHEMATIC
SINGLE OUTPUT
+Vin
REGULATOR
DUAL OUTPUT
+Vout
OSCILLATOR
DRIVER
-Vin
REGULATOR
+Vin
OSCILLATOR
DRIVER
-Vout
+Vout
Com.
-Vout
-Vin
REGULATOR
z MECHANICAL DIMENSIONS &
RECOMMENDED FOOTPRINT DETAILS
www.Power-Systems.de
Page: 3 / 5
PIN
SINGLE
DUAL
1&2
+Vin
+Vin
10 & 11
NO PIN
Common
12
-Vout
NO PIN
13
+Vout
-Vout
14
NO PIN
NO PIN
15
NO PIN
+Vout
23 & 24
-Vin
-Vin
Version: 4-Oct-02
DC-DC Converter UNIT
CBR Series ( 2W-3W REGULATED DC-DC CONVERTER )
z TYPICAL APPLICATIONS
SINGLE OUTPUT
INPUT
DUAL OUTPUT
OUTPUT
INPUT
OUTPUT
+Vout
+Vin
+Vin
+Vout
LOAD1
LOAD
DC-DC
CONVERTER
-Vin
Common
DC-DC
CONVERTER
-Vin
-Vout
LOAD2
-Vout
z TYPICAL PERFORMANCE CUREVES
Specifications typical at ta=25 OC,nominal input voltage , rated output current unless otherwise specified.
OUTPUT LOAD vs EFFICIENCY
OUTPUT LOAD vs OUTPUT VOLTAGE
OUTPUT VOLTAGE
CHANGE(%)
EFFICIENCY(%)
80%
60%
SAFE
OPERATING
AREA
40%
20%
0%
0%
20%
40%
60%
80%
10%
5%
0%
-5%
-10%
100%
0%
OUTPUT LOAD(%)
40%
60%
80% 100%
OUTPUT LOAD(%)
TEMPERATURE DERATING
INPUT VOLTAGE vs EFFICIENCY
125%
100%
EFFICIENCY(%)
OUTPUT POWER(%)
20%
100%
75%
50%
25%
80%
60%
40%
20%
0%
0%
-25
0
25
50
70
-10
100
Nom
5
10
INPUT VOLTAGE(%)
TA(degree C)
www.Power-Systems.de
-5
Page: 4 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
CBR Series ( 2W-3W REGULATED DC-DC CONVERTER )
CBR SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS:
No external capacitance is required for operation of the CBR series.
To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm
from DC to 100KHz is required.
External output capacitance is not required for operation, however it is recommended that 10uF
tantalum and 0.1uF ceramic capacitance be selected for reduced system noise.
Additional output capacitance may be added for increased filtering, but should not exceed 220uF.
Negative Outputs:
A negative output voltage may be obtained by connecting the +OUT to circuit ground and
connecting –OUT as the negative output.
FOR MORE INFORMATION CALL:
Power Systems – The Power Solution
Ilsfeld-Auenstein ( Germany ) Dörnet 8
Tel: + 49 / 70 62 / 67 59 – 6
E-mail: [email protected]
Home Page: www.Power-Systems.de
www.Power-Systems.de
Page: 5 / 5
Fax: + 49 / 70 62 / 67 59 -80
Version: 4-Oct-02