RECTRON BAT42

BAT42
SILICON PLANAR SCHOTTKY DIODES
FEATURES
* Fast Switching Device(TRR<4.0nS)
* DO-35 Package (JEDEC)
* Through-Hole Device Type Mounting
* Hermetically Sealed Glass
* Compression Bonded Construction
* All external surfaces are corrosion resistant and leads
are readily solderable
DO-35
.022 (0.56)
DIA.
.018 (0.46)
1.02 (26.0)
MIN.
.165 (4.2)
MAX.
.079 (2.0)
MAX.
DIA.
1.02 (26.0)
MIN.
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
o
MAXIMUM RATINGES ( @ TA = 25 C unless otherwise noted )
UNITS
SYMBOL
BAT42
VR
30
V
IF
200
mAmps
Maximum Peak Forward Current @tp<1s,d<0.5
IFRM
500
mAmps
Surge Forward Current @ tp<10ms
IFSM
4
Amps
Maximum Power Dissipation @ T A =65 OC
PD
200
mW
Junction Temperature
TJ
125
O
TSTG
-65 to + 150
O
RATINGS
Maximum Forward Comtinuous Reverse Voltage
Maximum Forward Comtinuous Current @ T A =25 OC
Storage Temperature Range
C
C
ELECTRICAL CHARACTERISTICS ( @ TA = 25oC unless otherwise noted )
CHARACTERISTICS
Reverse breakdown voltage (IR=100mA)
Reverse voltage leakage current (VR=25V,TJ=25 C)
O
(VR=25V,TJ=100OC)
SYMBOL
MIN.
TYP.
MAX.
UNITS
V(BR)R
30
-
-
V
IR
-
-
100
-
0.40
VF
-
-
0.65
-
1.0
(IF=10mA)
Forward voltage Pulse Tesx tp<300ms,d<2% (IF=50mA)
(IF=200mA)
0.5
mA
V
Diode capacitance (VR=1,f=1MHz)
CD
-
7.0
-
pF
Reveres recovery time (IF=IR=10mA,IRR=1mA,RL=100W)
trr
-
-
5
nS
2006-3
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.