RFHIC RFDR98-61

Cell ÅÆ PCS Converter(DR) RFUR89-60 / RFDR98-61
Product Features
Application
• Integrated Monolithic GaAs Converter Package Module
• High Reliability
• Lower Manufacturing Cost
• Higher Productivity
• Very Low Noise Figure & Low Distortion
• Very Low Phase Noise (Ceramic Resonator used)
• Pb Free / RoHS Standard
• Repeater
• Base Station
Package Type: HY-5A
Description
Converter is a very compact size due to using simple matching circuit board including PLL circuits.
Customers can apply this part to systems.
(Operating Temperature:-30°C~+80°C)
Specifications
PARAMETER
RFUR89-60 (UP)
RFDR98-61 (DOWN)
Input Frequency Range (MHz)
824~849
1750~1780
Output Frequency Range (MHz)
1750~1780
824~849
Local Frequency Range (MHz)
926~931
926~931
Conversion Gain (dB)
6±1
6±1
Gain Flatness @ 30MHz (dB) (Max.)
±1
±1
Noise Figure (Typ.)(dB)
7
10
OIP3 (dBm)
24
24
LO to RF Leakage (dBm)
-10
-15
LO to IF Leakage (dBm)
-20
-20
IF to RF / RF to IF Leakage (dBm)
-20
-20
LO Output Level
4±1
4±1
LO Phase Noise (Typ.)
Step Size : 200KHz
-65dBc/Hz @1KHz
-95dBc/Hz @10KHz
-115dBc/Hz @100KHz
-65dBc/Hz @1KHz
-95dBc/Hz @10KHz
-115dBc/Hz @100KHz
PLL Control (LMX2326)
3 wire
3 wire
Vcc/Idd
5V / 170mA
5V / 170mA
Functional Diagram
Input
Conv.
Output
Amp.
BUFFER
AMP.
Lo-Out
PLL
1
4
▪ Tel : 82-31-250-5011
▪ All specifications may change without notice.
▪ [email protected]
▪ Version 6.1
Cell ÅÆ PCS Converter(DR) RFUR89-60 / RFDR98-61
Pacakage Dimensions (Type: HY-5A)
Recommended Pattern
Pin No.
Function
Pin No.
Function
1
2
3
4
5
6
7
Input
Ground
Ground
Vcc+5V
Ground
Ground
Ref in
14
13
12
11
10
9
8
Output
Ground
Lo_Out
Fo/LD
LE
Data
Clock
RFHIC Corporation (RFHIC) reserves the right to make changes to any products herein or to discontinue any product at any time without notice. RFHIC do not
assume any liability for the suitability of its products for any particular purpose, and disclaims any and all liability, including without limitation consequential or
incidental damages. The product specifications herein expressed have been carefully checked and are assumed to be reliable. However, RFHIC disclaims liability for
inaccuracies and strongly recommends buyers to verify that the information they are using is current before placing purchase orders. RFHIC products are not
intended for use in life support equipment or application where malfunction of the product can be expected to result in personal injury or death. Buyer uses or sells
such products for any such unintended or unauthorized application, buyer shall indemnify, protect and hold RFHIC and its directors, officers, stockholders,
employees, representatives and distributors harmless against any and all claims arising out of such use. RFHIC’s liability under or arising out of damages, claims of
whatsoever kind and nature which RFHIC products could cause shall be limited in amount to the net purchase price of the products sold to buyer by RFHIC.
▪ Tel : 82-31-250-5011
▪ All specifications may change without notice.
▪ [email protected]
▪ Version 6.1