Many thanks for purchasing this ICEPIC3 daughterboard.
The ICEPIC 3 manual is supplied in electronic format on the
CD supplied with the In-Circuit Emulator. Current revisions
of the manual can also be downloaded from the RF
solutions website.
Installation of Daughter Board
1. Installation of a daughter board is a simple push fit onto
the topside of the ICEPIC3 motherboard, connecting
only by the two connectors. It is only possible to fit the
daughter board in a single orientation.
2. Ensure the Target header cables are securely inserted.
Jumper Link Configuration
There are several Jumper Links, which are used to configure your daughter board. These are all fitted to factory
default settings during manufacture.
A jumper link guide is installed along with the ICEPIC III software. This can be accessed from the windows start
menu, Start -> Programs -> ICEPIC III -> ‘Jumper Links.pdf’
Target Board Connectors
The daughterboard target board connectors are for use with the packages given in the table below.
Daughterboard
Connector
Target Board Package
P4
20 Pin SOIC
P8
18 Pin DIP
P3
20 Pin SOIC
P4
18 Pin DIP
I3DB16F84AR1
I3DB18F1320R1
Warning
Extra care is therefore advised when handling the ICEPIC system, in particular the ICEPIC Daughterboards.
Always apply Power to the ICEPIC pod BEFORE the target board and remove power from the ICEPIC after the
target board. Care must be taken to avoid exposing the Target probe cable to any excessive static or reverse
voltage.The Microchip emulation devices (16C01/3, 16CXXME etc) do not contain the same high voltage protection
on their I/O lines as the standard PIC Microcontrollers.
R. F. Solutions Ltd.,
Unit 21, Cliffe Industrial Estate, South Street, Lewes,
E. Sussex, BN8 6JL. England
Tel +44 (0)1273 898 000
Email [email protected]
Fax +44 (0)1273 480 661
http://www.rfsolutions.co.uk
RF Solutions is a member of the Low Power Radio Association
All Trademarks acknowledged and remain the property of the respected owners
Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such information.
Use of R.F.Solutions products as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd.
DS058-1 Dec ’04
©2004 RF Solutions Ltd, www.rfsolutions.co.uk
Tel 01273 898000 Fax 01273 480661
Page 1