RHOMBUS-IND L

CURRENT SENSE INDUCTORS
DESIGNED FOR SWITCHING POWER SUPPLY APPLICATIONS
HOLE THRU CENTER FOR PRIMARY WINDING
FREQUENCY RANGE 20KHZ OR GREATER
1 TURN PRIMARY PEAK SENSE CURRENT 20 AMPS
2500V RMS HIPOT
Electrical Specifications at 25OC
Secondary
Induct. min.
DCR
max.
Terminating
Resistance
( mH )
(Ω)
50
5.0
A
100
L-11003
A
L-11004
(Ω)
Pri. Unipolar
Amp-microsec.
Max. Rating
Pri. Bipolar
Amp-microsec.
Max. Rating
0.70
50
150
300
20.0
1.40
100
300
600
200
80.0
4.70
200
600
1200
A
300
180.0
11.00
300
900
1800
L-11011
B
50CT
5.0
0.70
50
150
300
L-11012
B
100CT
20.0
1.40
100
300
600
L-11013
B
200CT
80.0
4.50
200
600
1200
L-11014
B
300CT
180.0
11.00
300
900
1800
Part
Number
Schematic Style
L-11001
A
L-11002
Secondary
Turns
STYLE "B"
SCHEMATIC
STYLE "A"
SCHEMATIC
1
1
2
3
3
Physical Dimensions
inches (mm)
1) Leads are 20 AWG
2) Lead length is .170 Min.
Specifications are subject to change without notice
Rhombus
Industries Inc.
Transformers & Magnetic Products
I-SENSE - 2/96
2
15801 Chemical Lane
Huntington Beach, California 92649-1595
Phone: (714) 898-0960 • FAX: (714) 896-0971