SENSORTECHNICS HYD3X0G4CXSE

HYD Series
Submersible precision stainless steel pressure transmitters
FEATURES
· 0...0.1 to 0...4 bar,
(0...1 to 0...40 mH2O)
· For corrosive media
· 4...20 mA output
· Field interchangeable
· Intrinsically safe (option)9
MEDIA COMPATIBILITY
Wetted materials:
stainless steel 1.4404 (316L)8, Polyethylene,
Viton (EPDM)
Housing:
protection class IP 68 (according to DIN EN 60529)
respectively NEMA 6P1
ELECTRICAL CONNECTION
SPECIFICATIONS
Maximum ratings
Supply voltage2 (reverse polarity protection)
intrinsically safe version (option)
Temperature limits
Storage
Operating
Compensated
13...40 V
17...28 V
+Vs
-20 to +70°C
-10 to +70°C
0 to +65°C
+13 to 40 V
red
sensor
V
Proof pressure3
0.1 to 0.7 bar
0.7 to 1.5 bar
1.5 to 4.0 bar
-Vs
6 bar
10 bar
15 bar
black
RL
GND
bare
June 2008 / 580
1/4
www.sensortechnics.com
HYD Series
Submersible precision stainless steel pressure transmitters
INDIVIDUAL PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 24 V, tamb = 20°C, RL=550 Ω)
C haracteristics
Operating pressure
Min.
HYD0X1...
HYD0X2...
HYD0X4...
HYD0X7...
HYD1X0...
HYD1X5...
HYD2X0...
HYD3X0...
HYD4X0...
Typ.
0
0
0
0
0
0
0
0
0
Max.
U nit
0.1
0.2
0.4
0.7
1.0
1.5
2
3
4
bar
Zero pressure offset
3.968
4.000
4.032
Full scale span6
15.968
16.000
16.032
Full scale output
mA
20.0
4
Thermal effects (0 to 65°C)
Offset
Span
±0.015
±0.015
%FSS/°C
Non-linearity, hysteresis,
repeatability5
±0.2
%FSS
Long term stability
±0.1
%FSS/year
Response time (10 % to 90 %)
50
ms
Power consumption (IL = 20 mA)
260
mW
LOAD LIMITATION
intrinsically safe version:
R max =
June 2008 / 580
Vs − 13 V
0.02 A
R max =
Vs − 17 V
0.02 A
2/4
www.sensortechnics.com
HYD Series
Submersible precision stainless steel pressure transmitters
ELECTROMAGNETIC CAPABILITY7
Test conditions
Criterion
Radiated, radio frequency electromagnetic
field immunity
(RFI)
EN61000-4-3: Grade 3
10 V/m, 80 MHz to 1000 MHz
80 % AMC (1 kHz)
A
Electrical fast transient / burst immunity
(EFT)
EN61000-4-4: Grade 3
±2 kV
B
Electrostatic discharge immunity test
(ESD)
EN61000-4-2: Grade 4
±8 kV, contact discharge
B
Immunity to conducted disturbances
induced by radio-frequency fields
EN61000-4-6: Grade 3
0,15 to 80 MHz
10 V, 80 % AMC (1 kHz)
A
Specification notes (for all devices):
1. The package is an all-sealed housing. For proper function the gage port is vented to the atmosphere through the connecting
cable. Thus the vent tube of the cable end must have access to the ambient pressure.
2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation formula.
3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
4. Thermal effects tested and guaranteed from 0°C to 65°C relative to 20°C.
5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span.
6. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure.
7. Tests are in accordance with EN61000-6-2, April 99.
8. On special request. Hastelloy© is available.
9. Certificate: ATEX II 1G (CENELEC EEx ia IIC T4).
June 2008 / 580
3/4
www.sensortechnics.com
HYD Series
Submersible precision stainless steel pressure transmitters
Ø50
OUTLINE DRAWING
15
150
mass: typ. 800 g (without cable)
3m
other lengths
on request
dimensions in mm
WIRE CONNECTION
Color
Electrical connection
red
+Vs
black
-Vs
transparent
vent tube1
bare
case/shield
ORDERING INFORMATION
HYD
xxx
G
4
C
x
S
E
Option:
intrinsically safe9
HYD series
submersible
pressure ranges10
0X1: 0 to 0.1 bar
0X2: 0 to 0.2 bar
0X4: 0 to 0.4 bar
0X7: 0 to 0.7 bar
1X0: 0 to 1.0 bar
1X5: 0 to 1.5 bar
2X0:
0 to 2 bar
3X0:
0 to 3 bar
4X0:
0 to 4 bar
cable length in m
(standard 3 m)
cable version
output signal
4: 4 - 20 mA
pressure mode
G: gage pressure
Note 10: Other pressure ranges between 0.1 and 4.0 bar are available on request
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
June 2008 / 580
4/4
www.sensortechnics.com