SONARDYNE 7806

Sonardyne UK (Head Office)
T. +44 (0) 1252 872288
F. +44 (0) 1252 876100
E. [email protected]
www.sonardyne.com
Datasheet
Compatt Mk4 MF Directional (Discontinued)
Description
Key Features
The Computing and Telemeter
Transponder (Compatt) is a
microcomputer controlled subsea
transponder used for acoustic
navigation and positioning. The
Medium Frequency (MF, 18-36 kHz)
system is suited to a wide range of
tasks such as underwater
measurement, remote control and
monitoring.
• Sequential mode operation with 15
individual channel frequencies
• 12 channel receiver for high speed
positional updates
• Allows up to 945 individually
addressable Compatt to be used in
close proximity
• HPR option allows Compatt to be
used with Simrad HPR systems
• Programmable address code
The Type 7806 Mk4 Compatt is one
of the Medium Frequency versions of
Sonardyne’s fourth generation family
of transponders built to complement
the existing range of Long Baseline
products.
The Type 7806 has a SemiDirectional transducer directing a
high source level upwards to
overcome high noise levels on
surface vessels, especially vessels
using thrusters for Dynamic
Positioning. The transducer maintains
a good source level and sensitivity in
the horizontal direction to ensure
reliable inter-Compatt ranging for
array calibration. The Type 7806 is
a direct replacement for the earlier
Type 7805 Compatt, but has
improved acoustic performance
across the whole MF frequency
band.
• Conventional Enable and Disable
commands for normal transponder
operation
• Advanced telemetry facility replies
to all commands with Compatt
address, command executed and
error-checking
• Direct measurement of baselines
between Compatt improves array
calibration accuracy
• Baseline measurement to15 cm
• Measurement of temp. and depth
permits accurate evaluation of seabed sound velocity
• Battery checks and time/date
facility record remaining battery
capacity and time since last charge
• Cycle mode permits up to eight
preset commands to be executed
on receipt of one command
• Auto-disable at 90% of battery
packs usage
Sonardyne UK (Head Office)
T. +44 (0) 1252 872288
F. +44 (0) 1252 876100
E. [email protected]
www.sonardyne.com
Specifications
Compatt Mk4 MF Directional (Discontinued)
Feature
Depth Rating
Operating Frequency
Transducer Beam Shape
Typical Accuracy
Battery Type
Acoustic Output Power
(dB re 1µPa @ 1 metre)
Listening Life only (Enabled)
Listening Life only (Disabled)
Navigation Replies (High Power)
Navigation Replies (low Power)
Data Telemetry (high power)
Data Telemetry (low power)
Acoustic Receiver Threshold
Timing Resolution
Options
Sensor Depth
Temperature
Conductivity
Dual Axis Inclinometer
Battery
Weight in Air
Weight in Water
Type 7806
2,500 or 4,000 Metres
MF (19-36kHz)
Semi-Directional
Better than 15cm (static)
Ni-Cad
Alkaline
(single voltage)
(single voltage)
202dB
202dB
Lithium
(single voltage)
202dB
Lithium
(dual voltage)
199dB
89 days
1071 days
1786 days
2500 days
96 days
1304 days
2174 days
2500 days
0.4 X 10
1.3 X10
1.5 X 10
3.3 X 10
1.5 X 10
5.3 X 10
6.0 X 10
13.4 X 10
10 X 10³
36 X 10³
79 X 10³
90 X 10³
41 X 10³
144 X 10³
317 X 10³
360 X 10³
70-115dB re 1µPa (Programmable)
1.6µs
Strain Gauge pressure transducer ±0.2% (350M, 1350M, 2500M or 5000M
range) or Digiquartz Quartz Crystal Pressure Transducer. (1350M, 2050M or
4100M range ±0.02%)
Platinum Resistance ± 0.1ºC
Change in flux-linkage Sensor ± 0.25ppt
Schaevitz LSOP Inclinometer ± 14.5º range, (Accuracy ± 0.1º, Resolution ± 0.01º)
Lithium, Alkaline or Ni-Cap
External Sensor Monitoring
Acoustic Release End Cap
Remote Sensor Input available
24.1kg (2,500m Version), 26.1kg (4,000 Version)
11.2kg (2,500m Version), 13.2kg (4,000 Version)
Specifications subject to change without notice - 10/2006