TRACOPOWER TOP100-148

AC/DC Power Supplies
TOP 100 Series, 100 Watt
CB
Scheme
Features
◆ 100 W power supply in 2.0”x 4.0“ footprint!
◆ Full load operation up to +50°C with
UL 60950-1
convection cooling
◆ Highest efficiency, 90 % typ.
◆ EMI filter meets EN 55022, level B
◆ Compliance with EN 61000-3-2
◆ Low leakage current
◆ Safety class l and class ll operation
◆ 3-year product warranty
The new TOP-100 Series AC/DC Power Supplies feature the highest power rating
in the industry standard 2.0” x 4.0” (50.8 x 101.6 mm) footprint. They can supply
up to 100 W output power with convection cooling over an industrial operating
temperature range of –25°C to +50°C. This performance could be realized by a state
of the art design providing an extremely high efficiency of >90 % which eliminates
the need for a dedicated power supply cooling fan.
Also see: www.tracopower.com/products/top100_article_e1.pdf
Compliance with global safety and EMC standards qualify these power supplies for
worldwide markets. Approved for Class l and Class ll applications, these switchers
are suitable for industrial and IT systems but also for consumer products. High reliability is provided by use of industrial quality grade components and an excellent
thermal management. This product offers an interesting power supply solution for
many space and cost critical applications in commercial and industrial electronic
equipment.
Models
Order Code
Output Voltage
(Adjustment Range)
Output Current
max.
TOP 100-103
3.3 VDC
(3.3 - 3.5)
20.0 A
TOP 100-105
5.0 VDC
(5.0 - 5.2)
20.0 A
TOP 100-112
12 VDC
(12.0 - 13.0)
8.3 A
TOP 100-115
15 VDC
(15.0 - 16.0)
6.7 A
TOP 100-124
24 VDC
(24.0 - 26.0)
4.2 A
TOP 100-148
48 VDC
(48.0 - 52.0)
2.1 A
http://www.tracopower.com
Page 1 of 4
AC/DC Power Supplies
TOP-100 Series
100 Watt
Input Specifications
Input voltage range 90 – 132 / 187 – 264 VAC autorange
power derating at low input voltage: 50 % at 90 VAC – 0% at 103 VAC
20 % at 187 VAC – 0% at 207 VAC
Input frequency 47 – 63 Hz
Input protection T4 A/250 V internal fuse in both line & neutral
Harmoni limits EN 61000-3-2, class A
Zero load power consumption 3.6 W
Recommended circuit breaker 6 A (characteristic C) or slow blow fuse
Output Specifications
Regulation
– Input and Load variation 1.0 % max.
Ripple and noise (20Mhz Bandwidth) <100 mVp-p
48 VDC model: <200 mVp-p
Overvoltage protection 3.3
5.0
12
15
24
48
VDC
VDC
VDC
VDC
VDC
VDC
model:
model:
model:
model:
model:
model:
5.0 V
6.0 V
16 V
20 V
30 V
60 V
Power back immunity
3.3
5
12
15
24
48
VDC
VDC
VDC
VDC
VDC
VDC
model:
model:
model:
model:
model:
model:
5.0 V (6.0 V for 1 sec)
6.3 V (7.0 V for 1 sec)
16 V (18 V for 1 sec)
20 V (23 V for 1 sec)
35 V (40 V for 1 sec)
63 V (68 V for 1 sec)
Overload protection by current limit at 150 % Iout max.
Short circuit protection foldback (automatic recovery)
Capacitive load 10’000 µF max.
General Specifications
Operating temperature – 25°C to +70°C with derating
Power derating depending on temperature
Convection Cooling
Forced Air Cooling 5 CFM (300 LFM)
80
80
tput Power [W]
100
Output Power [W]
100
60
40
20
0
60
40
20
-25
0
20
40
60
80
0
-25
Ambient Temperature [°C]
For horizontal mounting
0
20
40
60
80
Ambient Temperature [°C]
3.3 VDC model
5 VDC model
other models
Temperature coefficient 0.02 %/K
Reliability, calculated MTBF @ 25°C acc. to IEC 61709 http://www.tracopower.com
3.3 – 12 VDC models: >1.0 Mio h
15 – 48 VDC models: >1.4 Mio h
Page 2 of 4
AC/DC Power Supplies
TOP-100 Series
100 Watt
General Specifications
Humidity (non condensing) 0 – 95 % rel. H max.
Efficiency
– Vin = 115 VAC 89 – 91 %
– Vin = 230 VAC 90 – 92 %
Switching frequency 100 kHz typ. (pulse width modulation)
Hold-up time – Vin = 115 VAC 10 ms typ.
– Vin = 230 VAC 15 ms typ.
Start-up time – Vin = 115 VAC <3.5s
– Vin = 230 VAC <2s
Isolation voltage
– Input / Output 4000 VAC
– Input / Field Ground 2000 VAC
– Output / Field Ground 500 VAC
Isolation resistance (at 500 VDC) 100 Mohm min.
Earth leakage current 250 µA max.
Isolation class class II double isolation
Electromagnetic compatibility – Conducted input RI suppression EN 55022, class B (conductive plane to be
(EMC), emissions connected to safety earth)
– Harmonic current emissions IEC / EN 61000-3-2, class A
Electromagnets compatibility – Electrostatic discharge ESD (EMC), immunity – RF field immunity – Electrical fast transients/burst immunity – Surge
– Conducted RF – Voltage dip IEC / EN 61000-4-2
IEC / EN 61000-4-3
IEC / EN 61000-4-4
IEC / EN 61000-4-5
IEC / EN 61000-4-6
IEC / EN 61000-4-11
Safety approvals and
– CB test certificate certifications
– CSA certificate
– GS certificate for IEC/EN 60950-1
www.tracopower.com/products/top100-cb.pdf
UL 60950-1, CSA 60950-1-03
www.tracopower.com/products/top100-csa.pdf
www.tracopower.com/products/top100-gs.pdf
Environment – Vibration acc. IEC 60068-2-6; 3 axis, sine sweep, 10-55Hz, 1g, 1oct/min
– Shock acc. IEC 60068-2-27 3 axis, 15g half sine, 11msShock
20 G (3 directions each 3 times)
Connection pin connector (Molex)
Weight 140 g (4.9 oz)
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 3 of 4
AC/DC Power Supplies
TOP-100 Series
100 Watt
Dimensions
4.0 (101.6)
2.0 (50.8)
OUT
Field Ground
4x ø 0.157 (4.0)
1.25 (31.8)
J2 1
1.75 (44.5)
1
J1
AC IN
0.14 (3.6)
3.75 (95.3)
6
Dimensions in Inch, () = mm
4x Pillars (not included) for connection to safety earth:
Height: 0.2 min. (5.0), Diam.: 0.25 max. (6.0)
Input
Output
Pin
J1
Pin
J2
1
AC in
1
– Vout
2
AC in
2
– Vout
3
– Vout
4
+ Vout
5
+ Vout
6
+ Vout
J1: Molex Series 41791
mates with Molex crimp terminal: 08-52-0072
and terminal housing: 09-50-3031
J2: Molex Series 41791
mates with Molex crimp terminal: 08-52-0072
and terminal housing: 09-50-3061
Specifications can be changed any time without notice.
Rev. 05/09
Jenatschstrasse 1 · CH-8002 Zurich · Switzerland
Tel. +41 43 311 45 11 · Fax +41 43 311 45 45 · [email protected] · www.tracopower.com
Page 4 of 4